24 results (0,13595 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

C-Tec AMRHA Handheld Radio Microphone Kit

C-Tec AMRLA Lavalier Radio Microphone Kit

C-Tec PDA5DW 200m2 Wall-Mounting Phased-Shifting Hearing Loop Amplifier

C-Tec PDA11DD 1000m2 Free-Standing Phased-Shifting Hearing Loop Amplifier

C-Tec PDA7DD 500m2 Free-Standing Phased-Shifting Hearing Loop Amplifier

C-Tec PDA11DW 1000m2 Wall-Mounting Phased-Shifting Hearing Loop Amplifier

C-Tec PDA7DW 500m2 Wall-Mounting Phased-Shifting Hearing Loop Amplifier

C-Tec PDA7SW 500m2 Wall-Mounting Hearing Loop Amplifier 7.5A

C-Tec PDA5SW 200m2 Wall-Mounting PDAS Hearing Loop Amplifier 4.75A

C-Tec PDA11SW 1000m2 Wall-Mounting Hearing Loop Amplifier 11A

C-Tec PDA7SD 500m2 Free-Standing Hearing Loop Amplifier 7.5A

C-Tec PDA5SD 200m2 Free-Standing Hearing Loop Amplifier 4.75A

C-Tec PDA11SD 1000m2 Free-Standing Hearing Loop Amplifier 11A

C-Tec FPROK1 FosMeter-Pro Hearing Loop Test Kit

C-Tec FPROK1 FosMeter-Pro Hearing Loop Test Kit

C-Tec FPROK1 FosMeter-Pro Hearing Loop Test KitSigNET recommends all its induction loop systems are tested using a Fosmeter Pro Induction Loop Test Kit FPROK1. Designed to simplify the setup of an induction loop system to the latest version of BS EN 60118-4 Magnetic field strength in audio-frequency induction loops for hearing aid purposes the kit includes an FPRO Fosmeter Pro induction loop tester cw intuitive display and simple to follow test menus a calibrated signal generator cw pre-loaded test tones and a set of headphones.As well as checking the magnetic field strength of an induction loop system it also measures background noise frequency response metal compensation AND allows you to listen to the loop signal. The tester and signal generator are each powered by a 9V PP3 battery and both are supplied in protective canvas carrying cases.Key FeaturesA must-have accessory for all AFILSinstallers and service engineers.Simplifies the setup of an induction loop system to BS EN 60118-4 Magnetic field strength in audio-frequency induction loops for hearing aid purposes.Includes an FPRO Fosmeter Pro induction loop tester cw intuitive display and simple to follow test menus a calibrated FPROSG Signal Generator cw pre-loaded test tones voice and music samples and a set of HEAD1 headphones.Checks the magnetic field strength of an induction loop system and measures background noise frequency responseandmetal compensation.Loop listening circuitry allows subjective listening tests to be carried out using the headphones supplied.Powered from a 9V PP3 battery.Supplied in a protective canvas carrying case.Auto power-off function helps to preserve battery life.

GBP 551.70
1

C-Tec PDA200E AKW1 Hearing Loop Kit for Place of Worship with Fixed Lectern Microphone

C-Tec PDA200E AKW1 Hearing Loop Kit for Place of Worship with Fixed Lectern Microphone

C-Tec PDA200E AKW1 Hearing Loop Kit for Place of Worship with Fixed Lectern MicrophoneHearing loop systems allow hearing impaired people to hear more clearly. Most hearing aids have a T or MT switch which allows them to pick up the electromagnetic field generated by a hearing loop system. The hearing aid converts this signal into a sound suited to its users specific hearing requirements.Any person with a hearing aid positioned within or near the loop can hear the loop signal by switching their hearing aid to the correct position allowing them to participate more effectively in general conversation ordering goods or services listening to public performances etc.Includes a PDA200E hearingloop amplifier AML lectern microphone APJ 3.5mm jack input plate APL line level audio inputplate and 2 x 6m of Belden cable. Ideal for creatinga high-quality hearingloop system for a place of worship.Key FeaturesWall-mountable PDA200E amplifier capable of driving a perimeter loop of up to 200m2.Internal drive level and metal compensation controls.Two balanced unbalanced line level inputs.One microphone input with 12V phantom power for electret microphones.Full compatibility with the Outreach plate audio input extension system.Fully compliant withBS EN 60118-4 when correctly installed.Technical SpecificationInduction Loop Type Wall mounting requires fixed mains wiringCoverage 200m2 approx.Dimensions W 273 x H 200 x D 77mm amplifier only 2.82kgInputs 1 x Microphone 2 x LineOutreachIndicators Input level Power Compression Peak Current 321Controls Metal Compensation Input level loop drivePlease Note the AK range of hearing loop kits dont come with loop cable please use 1mm2 single core cable such as C-Tecs LOOP2W cable.

GBP 452.76
1

C-Tec PDA200E AKH1L Hearing Loop Kit for Health and Fitness Club 200m2

C-Tec PDA200E AKH1L Hearing Loop Kit for Health and Fitness Club 200m2

C-Tec PDA200E AKH1L Hearing Loop Kit for Health and Fitness Club 200m2Hearing loop systems allow hearing impaired people to hear more clearly. Most hearing aids have a T or MT switch which allows them to pick up the electromagnetic field generated by a hearing loop system. The hearing aid converts this signal into a sound suited to its users specific hearing requirements.Any person with a hearing aid positioned within or near the loop can hear the loop signal by switching their hearing aid to the correct position allowing them to participate more effectively in general conversation ordering goods or services listening to public performances etc.Includes a PDA200E hearing loop amplifierAMRLA lavalier radio microphone APJ outreach plate APLoutreach plate audio input for CDtape deck and 2 x 6m Belden cable. Ideal for creatinga high-quality hearingloop system for a health and fitness club.Key FeaturesWall-mountable PDA200E amplifier capable of driving a perimeter loop of up to 200m2.Internal drive level and metal compensation controls.Two balanced unbalanced line level inputs.One microphone input with 12V phantom power for electret microphones.Full compatibility with the Outreach plate audio input extension system.Fully compliant withBS EN 60118-4 when correctly installed.AMRLA lavalier radio microphone kit includes receiver transmitter PSU and 4 selectable frequencies.Technical SpecificationInduction Loop Type Wall mounting requires fixed mains wiringCoverage 200m2 approx.Dimensions W 273 x H 200 x D 77mm amplifier only 2.82kgInputs 1 x Microphone 2 x LineOutreachIndicators Input level Power Compression Peak Current 321Controls Metal Compensation Input level loop drivePlease Note the AK range of hearing loop kits dont come with loop cable please use 1mm2 single core cable such as C-Tecs LOOP2W cable.

GBP 1022.15
1

C-Tec PDA5DD 200m2 Free Standing Phase-Array Hearing Loop Amplifier

C-Tec PDA200E AKW2L Hearing Loop Kit for Place of Worship with Levalier Radio Microphone 200m2

C-Tec PDA200E AKW2L Hearing Loop Kit for Place of Worship with Levalier Radio Microphone 200m2

C-Tec PDA200E AKW2L Hearing Loop Kit for Place of Worship with Levalier Radio Microphone 200m2Hearing loop systems allow hearing impaired people to hear more clearly. Most hearing aids have a T or MT switch which allows them to pick up the electromagnetic field generated by a hearing loop system. The hearing aid converts this signal into a sound suited to its users specific hearing requirements.Any person with a hearing aid positioned within or near the loop can hear the loop signal by switching their hearing aid to the correct position allowing them to participate more effectively in general conversation ordering goods or services listening to public performances etc.Includes a PDA200E hearing loop amplifier AMRLA lavalier radio microphone APJ outreach plateAPXM outreach plate for use with existing mics and 2 x 6m Belden cable. Ideal for creatinga high-quality hearingloop system for a place of worship.Key FeaturesWall-mountable PDA200E amplifier capable of driving a perimeter loop of up to 200m2.Internal drive level and metal compensation controls.Two balanced unbalanced line level inputs.One microphone input with 12V phantom power for electret microphones.Full compatibility with the Outreach plate audio input extension system.Fully compliant withBS EN 60118-4 when correctly installed.AMRLA lavalier radio microphone kit includes receiver transmitter PSU and 4 selectable frequencies.Technical SpecificationInduction Loop Type Wall mounting requires fixed mains wiringCoverage 200m2 approx.Dimensions W 273 x H 200 x D 77mm amplifier only 2.82kgInputs 1 x Microphone 2 x LineOutreachIndicators Input level Power Compression Peak Current 321Controls Metal Compensation Input level loop drivePlease Note the AK range of hearing loop kits dont come with loop cable please use 1mm2 single core cable such as C-Tecs LOOP2W cable.

GBP 992.46
1

C-Tec PDA200E AKW2H Hearing Loop Kit for Place of Worship with Handheld Radio Microphone 200m2

C-Tec PDA200E AKW2H Hearing Loop Kit for Place of Worship with Handheld Radio Microphone 200m2

C-Tec PDA200E AKW2H Hearing Loop Kit for Place of Worship with Handheld Radio Microphone 200m2Hearing loop systems allow hearing impaired people to hear more clearly. Most hearing aids have a T or MT switch which allows them to pick up the electromagnetic field generated by a hearing loop system. The hearing aid converts this signal into a sound suited to its users specific hearing requirements.Any person with a hearing aid positioned within or near the loop can hear the loop signal by switching their hearing aid to the correct position allowing them to participate more effectively in general conversation ordering goods or services listening to public performances etc.Includes a PDA200E hearing loop amplifierAMRHA handheld radio microphone APJ outreach plate APXMoutreach plate for use with existing mics and 2 x 6m of Belden cable. Ideal for creatinga high-quality hearingloop system for aTV or Music lounge.Key FeaturesWall-mountable PDA200E amplifier capable of driving a perimeter loop of up to 200m2.Internal drive level and metal compensation controls.Two balanced unbalanced line level inputs.One microphone input with 12V phantom power for electret microphones.Full compatibility with the Outreach plate audio input extension system.Fully compliant withBS EN 60118-4 when correctly installed.AMRHA handheld radio microphone kit includes receiver transmitter PSU and 4 selectable frequencies.Technical SpecificationInduction Loop Type Wall mounting requires fixed mains wiringCoverage 200m2 approx.Dimensions W 273 x H 200 x D 77mm amplifier only 2.82kgInputs 1 x Microphone 2 x LineOutreachIndicators Input level Power Compression Peak Current 321Controls Metal Compensation Input level loop drivePlease Note the AK range of hearing loop kits dont come with loop cable please use 1mm2 single core cable such as C-Tecs LOOP2W cable.

GBP 992.46
1

C-Tec ECU-8 SigTEL 8 Line Controller

C-Tec ECU-8 SigTEL 8 Line Controller

C-Tec ECU-8 SigTEL 8 Line ControllerFor most people a simple instruction like please leave the building by the nearest available exit can be acted upon quickly and easily. But for wheelchair users the disabled and infirm this isnt always the case. Current Building Regulations recognise this and insist all new non-domestic buildings with more than one storey provide refuge areas relatively safe places where people who cannot easily use fire escapes and evacuation lifts can call for assistance and wait until help arrives.Simple effective two-way communication in these areas is essential firstly to assist rescue teams in determining where assistance is required and secondly to reassure people help is on the way. Communication systems in refuge areas are known as Emergency Voice Communication EVC Systems and SigTEL is suitable for use in all types of EVC application be it a disabled refuge fire telephone or stadium marshalling system. Incredibly easy to use and offering true duplex speech SigTEL meets and exceeds the requirements of standards such as BS 5839 part 9 in all areas and is hugely cost-effective in comparison to other systems on the market.Key FeaturesIdeal for disabled refuge fire telephone and stadium marshalling applications.Allows operators to communicate with up to eightdisabled refuge or fire telephone outstations.Expandable to 16 lines using an ECU-8 expansion unit.Networking facility allows up to four controllers plus any expansion units to be interlinked allowing systems of up to 64 lines to be implemented.Supplied with a backlit LCD and handset.True duplex speech.Unique auto-learn facility allows fast system set up.Can be semi-flush mounted using an AFP385 bezel.Operation can be maintained for 24 hours standby and 3 hours in use using 2 x 12V 7 Ahr batteries.Easily interfaced to NC951 accessible toilet alarms PDA audio-frequency induction loop systems strobes CCTV activation relays etc.

GBP 1374.36
1

C-Tec ECU-4 SigTEL 4 Line Controller

C-Tec ECU-4 SigTEL 4 Line Controller

C-Tec ECU-4 SigTEL 4 Line ControllerFor most people a simple instruction like please leave the building by the nearest available exit can be acted upon quickly and easily. But for wheelchair users the disabled and infirm this isnt always the case. Current Building Regulations recognise this and insist all new non-domestic buildings with more than one storey provide refuge areas relatively safe places where people who cannot easily use fire escapes and evacuation lifts can call for assistance and wait until help arrives.Simple effective two-way communication in these areas is essential firstly to assist rescue teams in determining where assistance is required and secondly to reassure people help is on the way. Communication systems in refuge areas are known as Emergency Voice Communication EVC Systems and SigTEL is suitable for use in all types of EVC application be it a disabled refuge fire telephone or stadium marshalling system. Incredibly easy to use and offering true duplex speech SigTEL meets and exceeds the requirements of standards such as BS 5839 part 9 in all areas and is hugely cost-effective in comparison to other systems on the market.Key FeaturesIdeal for disabled refuge fire telephone and stadium marshalling applications.Allows operators to communicate with up to four disabled refuge or fire telephone outstations.Expandable to 12 lines using an ECU-8 expansion unit.Networking facility allows up to four controllers plus any expansion units to be interlinked allowing systems of up to 64 lines to be implemented.Supplied with a backlit LCD and handset.True duplex speech.Unique auto-learn facility allows fast system set up.Can be semi-flush mounted using an AFP385 bezel.Operation can be maintained for 24 hours standby and 3 hours in use using 2 x 12V 7 Ahr batteries.Easily interfaced to NC951 accessible toilet alarms PDA audio-frequency induction loop systems strobes CCTV activation relays etc.

GBP 1076.70
1

C-Tec PDA200E AKT1 Hearing Loop Kit for TV Music Lounge 200m2

C-Tec PDA200E AKT1 Hearing Loop Kit for TV Music Lounge 200m2

C-Tec PDA200E AKT1 Hearing Loop Kit for TV Music Lounge 200m2Hearing loop systems allow hearing impaired people to hear more clearly. Most hearing aids have a T or MT switch which allows them to pick up the electromagnetic field generated by a hearing loop system. The hearing aid converts this signal into a sound suited to its users specific hearing requirements.Any person with a hearing aid positioned within or near the loop can hear the loop signal by switching their hearing aid to the correct position allowing them to participate more effectively in general conversation ordering goods or services listening to public performances etc.Includes a PDA200E hearingloop amplifier AMP handheld microphone APS SCART to double phono lead APXM outreach plate APL outreach plate AL5 lead and 2 x 6m Belden cable. Ideal for creatinga high-quality induction loop system for aTV or Music lounge.Key FeaturesWall-mountable PDA200E amplifier capable of driving a perimeter loop of up to 200m2.Internal drive level and metal compensation controls.Two balanced unbalanced line level inputs.One microphone input with 12V phantom power for electret microphones.Full compatibility with the Outreach plate audio input extension system.Fully compliant withBS EN 60118-4 when correctly installed.Loop cable not included-use our LOOP2W1mm2 cable or download our AFILS loop calculator from our Software Apps page formore precise recommendations.Technical SpecificationInduction Loop Type Wall mounting requires fixed mains wiringCoverage 200m2 approx.Dimensions W 273 x H 200 x D 77mm amplifier only 2.82kgInputs 1 x Microphone 2 x LineOutreachIndicators Input level Power Compression Peak Current 321Controls Metal Compensation Input level loop drivePlease Note the AK range of hearing loop kits dont come with loop cable please use 1mm2 single core cable such as C-Tecs LOOP2W cable.

GBP 843.79
1

C-Tec PDA200E AKM3 Hearing Loop Kit for Professional Meeting Seminar Room 200m2

C-Tec PDA200E AKM3 Hearing Loop Kit for Professional Meeting Seminar Room 200m2

C-Tec PDA200E AKM3 Hearing Loop Kit for Professional Meeting Seminar Room 200m2Hearing loop systems allow hearing impaired people to hear more clearly. Most hearing aids have a T or MT switch which allows them to pick up the electromagnetic field generated by a hearing loop system. The hearing aid converts this signal into a sound suited to its users specific hearing requirements.Any person with a hearing aid positioned within or near the loop can hear the loop signal by switching their hearing aid to the correct position allowing them to participate more effectively in general conversation ordering goods or services listening to public performances etc.Includes a PDA200E hearing loop amplifier PRO45 hanging ambient microphone APXM outreach plate and 6m Belden cable. Ideal for creatinga high-quality induction loop system for a professional meeting or seminar room.Key FeaturesWall-mountable PDA200E amplifier capable of driving a perimeter loop of up to 200m2.Internal drive level and metal compensation controls.Two balanced unbalanced line level inputs.One microphone input with 12V phantom power for electret microphones.Full compatibility with the Outreach plate audio input extension system.Fully compliant withBS EN 60118-4 when correctly installed.Technical SpecificationInduction Loop Type Wall mounting requires fixed mains wiringCoverage 200m2 approx.Dimensions W 273 x H 200 x D 77mm amplifier only 2.82kgInputs 1 x Microphone 2 x LineOutreachIndicators Input level Power Compression Peak Current 321Controls Metal Compensation Input level loop driveAKM3 Meeting room kit PDA200E 200m2 hearing loop amplifier PRO45 hanging ambient microphone APXM XLR mic. Level connector plate 1 x 6m Belden cable Loop Fitted sticker. Loop cable is not included.Please Note the AK range of hearing loop kits dont come with loop cable please use 1mm2 single core cable such as C-Tecs LOOP2W cable.

GBP 834.25
1

C-Tec ECU-8NT SigTEL 8 Line Controller with No Handset

C-Tec ECU-8NT SigTEL 8 Line Controller with No Handset

C-Tec ECU-8NT SigTEL 8 Line Controller with No HandsetFor most people a simple instruction like please leave the building by the nearest available exit can be acted upon quickly and easily. But for wheelchair users the disabled and infirm this isnt always the case. Current Building Regulations recognise this and insist all new non-domestic buildings with more than one storey provide refuge areas relatively safe places where people who cannot easily use fire escapes and evacuation lifts can call for assistance and wait until help arrives.Simple effective two-way communication in these areas is essential firstly to assist rescue teams in determining where assistance is required and secondly to reassure people help is on the way. Communication systems in refuge areas are known as Emergency Voice Communication EVC Systems and SigTEL is suitable for use in all types of EVC application be it a disabled refuge fire telephone or stadium marshalling system. Incredibly easy to use and offering true duplex speech SigTEL meets and exceeds the requirements of standards such as BS 5839 part 9 in all areas and is hugely cost-effective in comparison to other systems on the market.Key FeaturesIdeal for disabled refuge fire telephone and stadium marshalling applications.Does not include a handset - ideal for use on networked SigTEL systems that do not require multiple control points.Can be connected to up to eightdisabled refuge or fire telephone outstations.Expandable to 16 lines using an ECU-8 expansion unit.Networking facility allows up to four controllers plus any expansion units to be interlinked allowing systems of up to 64 lines to be implemented.Supplied with a backlit LCD display.Unique auto-learn facility allows fast system set up.Can be semi-flush mounted using an AFP385 bezel.Operation can be maintained for 24 hours standby and 3 hours in use using 2 x 12V 7 Ahr batteries.Easily interfaced to NC951 accessible toilet alarms PDA audio-frequency induction loop systems strobes CCTV activation relays etc.

GBP 1152.70
1