29 results (0,15555 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

C-Tec EP210S Surface Remote Status Unit

C-Tec EP210F Flush Remote Status Unit

C-Tec QT609SSS Quantec Stainless Steel Call Point - Button Reset with Sounder Single Gang

C-Tec QT609KSSS Quantec Stainless Steel Call Point with Key Reset and Sounder Single Gang

C-Tec QT602KSSS Quantec Stainless Steel Call Point - Key Reset with Sounder

C-Tec QT707S Quantec Surveyor Data Management Software

C-Tec CFP760 8 Zone Repeater Panel

C-Tec XFP510-32 XFP Repeater Panel 32 Zone

C-Tec XFP510-32 XFP Repeater Panel 32 Zone

C-Tec XFP510-32 XFP Repeater Panel 32 ZoneCan be used to repeat the functions of an XFP Main panel at remote parts of a site e.g. all potential fire service entrances. Offers all of the functions and controls of an XFP Main panel access levels 1 2 and 3. Includes an on-board fault relay. Requires its own dedicated Mains power and battery back-up supply.A maximum of eight XFP Repeaters can be connected to one non-networked XFP Main panel. Communication between the XFP Main panel and Repeater requires an AFP711 network driver card fitted as standard in all XFP510-32s available as an optional extra on Main XFP 32 Zone panels. Repeater network wired in 1.5 mm2 two-core screened fire resistant cable. Network length must not exceed 500 metres.Key FeaturesCan be used to repeat the functions of an XFP Main panel at remote parts of a site e.g. all potential fire service entrances.Offers all of the functions and controls of an XFP Main panel access levels 1 2 and 3.Includes an on-board fault relay.Requires its own dedicated Mains power and battery back-up supply.A maximum of eight XFP Repeaters can be connected to one non-networked XFP Main panel.Communication between the XFP Main panel and Repeater requires an AFP711 network driver card fitted as standard in all XFP510-32s available as an optional extra on Main XFP 32 Zone panels.Repeater network is non-redundant and wired in 1.5 mm2 two-core screened fire resistant cable. Network length must not exceed 500 metres.

GBP 433.36
1

C-Tec XFP510-16 XFP Repeater Panel 16 Zone

C-Tec XFP510-16 XFP Repeater Panel 16 Zone

C-Tec XFP510-16 XFP Repeater Panel 16 ZoneCan be used to repeat the functions of an XFP Main panel at remote parts of a site e.g. all potential fire service entrances. Offers all of the functions and controls of an XFP Main panel access levels 1 2 and 3. Includes an on-board fault relay. Requires its own dedicated Mains power and battery back-up supply.A maximum of eight XFP Repeaters can be connected to one non-networked XFP Main panel. Communication between the XFP Main panel and Repeater requires a CFP761 network driver card fitted as standard in all XFP510-16s available as an optional extra on Main XFP 16 Zone panels. Repeater network wired in 1.5 mm2 two-core screened fire resistant cable. Network length must not exceed 500 metres.Key FeaturesCan be used to repeat the functions of an XFP Main panel at remote parts of a site e.g. all potential fire service entrances.Offers all of the functions and controls of an XFP Main panel access levels 1 2 and 3.Includes an on-board fault relay.Requires its own dedicated Mains power and battery back-up supply.A maximum of eight XFP Repeaters can be connected to one non-networked XFP Main panel.Communication between the XFP Main panel and Repeater requires a CFP761 network driver card fitted as standard in all XFP510-16s available as an optional extra on Main XFP 16 Zone panels.Repeater network wired in 1.5 mm2 two-core screened fire resistant cable. Network length must not exceed 500 metres.

GBP 315.26
1

C-Tec QT602SSS Quantec Stainless Steel Call Point - Button Reset with Sounder

C-Tec 24V 5A EN54-4 Switch Mode PSU BF562-5

C-Tec EP203 3 Zone Automatic Extinguisher Panel LPCB Certified - EP203

C-Tec EP203 3 Zone Automatic Extinguisher Panel LPCB Certified - EP203

C-Tec EP203 3 Zone Automatic Extinguisher Panel LPCB Certified - EP203The EP203 three zone automatic extinguisher panel has been specifically designed for use in areas housing expensive dangerous or irreplaceable items of equipment. Third-party approved by the LPCB to EN 12094-1 the European standard for Fixed Firefighting Systems - Components for Gas Extinguishing Systems and EN54 parts 2 and 4 the panel epitomises quality durability and reliability.Featuring an intuitive 128 x 64 pixel two-colour graphic display that gives clear and concise feedback to the user installer and commissioning engineer the panel also includes six monitored inputs including hold and abort a time stamped log adjustable flood times and volt-free changeover relays for fire local fire 1st stage active 2nd stage active extractor fan and fault.The panel is supplied in an elegantly styled durable enclosure with all of its electronics - apart from its powerful 3A EN54-4 switch mode PSU - mounted on a detachable metal bridge plate for ease of installation. A wide range of ancillaries are also available including remote status units hold-off and abort buttons line terminators and output expansion relay boards.Key FeaturesThird-party LPCB certificated to EN 12094 part 1 and EN54 parts 2 and 4Functions as a standard three zone fire panel with additional circuitry for controlling the release of fire-suppressing gas into protected areasUnique 128 x 64 pixel graphical display facilitates straightforward system programmingAny combination of activated zones can be programmed to automatically start the panels extinguishant release sequenceIncludes a pull-down front-panel manual release button and two keyswitches for accessing the panels functions and toggling between automanual modeThree conventional sounder circuits two x 1st stage one x 2nd stagePowerful 3A EN54-4 compliant switch mode PSULow quiescent current - less than 40mA on mains failWide range of monitored inputs and auxiliary outputs see schematicAbort and hold inputs allow the panels release sequence to be cancelled or suspended at any timeTime-stamped event logRS485 connections for up to eight flush or surface remote status units with their own LCDs manual release and mode automanual switches. Single gang economy status units without an LCD are also available.Extensive range of commissioning and engineering functionsOptional relay expansion boards and single gang abort and hold buttonsIdeal for use in computer rooms telecommunication centres archive storage areas chemical plants generator rooms museums etc..System line terminator included with all panels

GBP 399.43
1

C-Tec ENVS4-1 ENVISION FIRE IOT Software Licence 1-4 Panel Network - 1 YEAR

C-Tec ENVS4-1 ENVISION FIRE IOT Software Licence 1-4 Panel Network - 1 YEAR

C-Tec ENVS4-1 ENVISION FIRE IOT Software Licence 1-4 Panel Network - 1 YEARENVISION software licence for use with ENV-HUB 1-4 panel network.About ENVISION softwareENVISION is a Cloud based remote access service test and data management software package from C-TEC.Add an ENVISION IoT Gateway Hub order code ENV-HUB to your C-TEC CAST protocol fire detection and alarm systems to unlock a host of powerful features that are perfect for installers end users duty holders site managers responsible persons and more.Want to check the status of a CAST system from a remote location Not a problem Wherever you are in the world ENVISION allows you to generate powerful site-specific reports that can be scheduled to arrive on your desktop daily weekly or monthly to help demonstrate due diligence via a verifiable audit trail.Want fires faults tests and other system notifications to be sent in real time to a PC tablet or smart phone Job done Theres even a powerful graphics module that allows you to monitor the progress of a fire as it happens on a user- uploaded site map or building plan.Want evidence that a clients weekly BS 5839-1 user tests are being carried out Its all there at the touch of button.ENVISION really comes into its own if youre an installer or a service and maintenance company. Not only does it allow authorised personnel to interrogate a CAST system prior to visiting site to determine if there are any contaminated devices or other issues ENVISIONs iOS and Android compatible Engineer App can save you masses of time and money.Simply download the App enter a sites unique service PIN code and turn a two-man service job into a one-man service job. Not only will the App countdown the number of tests that need performing successful and failed tests will be reported to your device and you will have the option to add comments or upload photos as required for inclusion in future client reports. No longer will you need to invent a complex verification system to prove that a device has been tested thanks to ENVISION all the data you need will be available 247.In an era when failure to carry out your fire safety responsibilities can leave you open to litigation ENVISION not only makes your job easier it provides indisputable evidence that you are carrying out your mandated duties effectively.Key FeaturesValid for 1 yearPlease note The image is for illustrative purposes only.

GBP 252.00
1

C-Tec ENVS64-1 ENVISION FIRE IOT Software Licence 5-64 Panel Network - 1 YEAR

C-Tec ENVS64-1 ENVISION FIRE IOT Software Licence 5-64 Panel Network - 1 YEAR

C-Tec ENVS64-1 ENVISION FIRE IOT Software Licence 5-64 Panel Network - 1 YEARENVISION software licence for use with ENV-HUB 5-64 panel network.About ENVISION softwareENVISION is a Cloud based remote access service test and data management software package from C-TEC.Add an ENVISION IoT Gateway Hub order code ENV-HUB to your C-TEC CAST protocol fire detection and alarm systems to unlock a host of powerful features that are perfect for installers end users duty holders site managers responsible persons and more.Want to check the status of a CAST system from a remote location Not a problem Wherever you are in the world ENVISION allows you to generate powerful site-specific reports that can be scheduled to arrive on your desktop daily weekly or monthly to help demonstrate due diligence via a verifiable audit trail.Want fires faults tests and other system notifications to be sent in real time to a PC tablet or smart phone Job done Theres even a powerful graphics module that allows you to monitor the progress of a fire as it happens on a user- uploaded site map or building plan.Want evidence that a clients weekly BS 5839-1 user tests are being carried out Its all there at the touch of button.ENVISION really comes into its own if youre an installer or a service and maintenance company. Not only does it allow authorised personnel to interrogate a CAST system prior to visiting site to determine if there are any contaminated devices or other issues ENVISIONs iOS and Android compatible Engineer App can save you masses of time and money.Simply download the App enter a sites unique service PIN code and turn a two-man service job into a one-man service job. Not only will the App countdown the number of tests that need performing successful and failed tests will be reported to your device and you will have the option to add comments or upload photos as required for inclusion in future client reports. No longer will you need to invent a complex verification system to prove that a device has been tested thanks to ENVISION all the data you need will be available 247.In an era when failure to carry out your fire safety responsibilities can leave you open to litigation ENVISION not only makes your job easier it provides indisputable evidence that you are carrying out your mandated duties effectively.Key FeaturesValid for 1 yearPlease note The image is for illustrative purposes only.

GBP 347.76
1

C-Tec PDA103C Wall Mounting Counter Hearing Loop Kit 1.2m2

C-Tec PDA103C Wall Mounting Counter Hearing Loop Kit 1.2m2

C-Tec PDA103C Wall Mounting Counter Hearing Loop Kit 1.2m2Hearing loop systems allow hearing impaired people to hear more clearly. Most hearing aids have a T or MT switch which allows them to pick up the electromagnetic field generated by a hearing loop system. The hearing aid converts this signal into a sound suited to its users specific hearing requirements.Any person with a hearing aid positioned within or near the loop can hear the loop signal by switching their hearing aid to the correct position allowing them to participate more effectively in general conversation ordering goods or services listening to public performances etc.The PDA102C is ideal for banks post offices small meetingrooms reception desks ticket booths andany other application requiring restrictedor small area coverage.Key FeaturesIncludes a 3.5mm microphone input foruse with the AMT microphone suppliedand a lineoutreach socket.Adjustable drive control allows theamplifiers output stage to be set-up to suitthe exact characteristics of any room.State-of-the-art audio processor featuresan automatic gain control whichcompensates for poor microphonetechniques and helps suppress loudnoises hisses and clicks.Designed to be free-standing orwall-mounted using the keyholes provided.Technical SpecificationType free-standingwall mountable. Plug top mains lead supplied.Coverage 1.2m2 approx.Mains supply plug top mains lead supplied.Auxiliary inputs 1 x 3.5mm remote mic. Socket 1 x Line Outreach socket.Indicators input level loop current power on.Controls Combined input level loop drive.Product dimension W136 H56 x D178mm amplifier only.Construction finish black metalIP rating IP20Weight 1.25Kg

GBP 189.32
1

C-Tec PL1K1 Portable Hearing Loop Kit with Storage Shelf 1.2m2

C-Tec PL1K1 Portable Hearing Loop Kit with Storage Shelf 1.2m2

C-Tec PL1K1 Portable Hearing Loop Kit with Storage Shelf 1.2m2Hearing loop systems allow hearing impaired people to hear more clearly. Most hearing aids have a T or MT switch which allows them to pick up the electromagnetic field generated by a hearing loop system. The hearing aid converts this signal into a sound suited to its users specific hearing requirements.Any person with a hearing aid positioned within or near the loop can hear the loop signal by switching their hearing aid to the correct position allowing them to participate more effectively in general conversation ordering goods or services listening to public performances etc.The PL1K1 is ideal for restricted person to person contact in areas such as banks post offices small meeting rooms reception desks open plan offices and ticket booths. The units portable lightweight design means the system can be moved easily from location to location.Key FeaturesSimple one button operation.Integral high-performance microphone.Excellent sound quality.Five years expected battery life under normal operatingcharging conditions.Auto shut-off facility user selectable for 10 30 or 60 minutes helps preserve battery life.Connection of the plug-top charger overrides the timer function to ensure the unit remains operational at all times.Unit can be used as normal whilst charging.Technical SpecificationType - PortableCoverage - 1.2m2 approx.Dimensions - W 271 x H 200 x D 77mm amplifier only 2.82kgInputs 2 x Mic one built-in mic. and one 3.5mm remote mic. socket for AMT or AMD micsIndicators - Power on input level charging required charging in progress audio warning of imminent shutdownControls - Onoff button adjust auto-shut off timer

GBP 202.64
1

C-Tec CFP708-4 8 Zone Conventional Fire Panel LPCB Approved

C-Tec CFP708-4 8 Zone Conventional Fire Panel LPCB Approved

C-Tec CFP 8 Zone Conventional Fire Panel LPCB Approved - CFP708-4LPCB certified to EN54-24 C-TECs CFP 8 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price. Supplied in an attractive flush or surface mountable plastic enclosure it includes two detector zones four conventional sounder circuits class change and alert inputs on-board fire and fault relays and combined keypadkey switch entry.A wide range of engineering functions are also provided including selectable zone delays coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided. Optional repeaters relay expansion boards and EN54-13 system compliance devices are also available.Key FeaturesThird-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board LPCB with optional EN54 part 13 compliance from the BSI.Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry.Manufactured by C-TEC in the UK.Two detector zone circuits.Four conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSU.Wide range of engineering functions including zone test coincidence zone delay and non-latching zones.Two on-board relays Fire and Fault.Two open-collector outputs Remote and Reset.Class change and alert inputs.Installer-friendly design.Attractive flush or surface mountable plastic lid and enclosure - no bezel required.Low 25mA quiescent current.Multiple indicators.System expansion connections provided for up to eight two-wire repeaters one CFP761 network card required per system optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.Space for two x 12V 3.3Ah VRLA batteries.Fully compatible with C-TECs ActiV range of conventional fire detectors.

GBP 208.82
1

C-Tec PL1K3 Portable Hearing Loop Kit with Carry Case 1.2m2

C-Tec PL1K3 Portable Hearing Loop Kit with Carry Case 1.2m2

C-Tec PL1K3 Portable Hearing Loop Kit with Carry Case 1.2m2Hearing loop systems allow hearing impaired people to hear more clearly. Most hearing aids have a T or MT switch which allows them to pick up the electromagnetic field generated by a hearing loop system. The hearing aid converts this signal into a sound suited to its users specific hearing requirements.Any person with a hearing aid positioned within or near the loop can hear the loop signal by switching their hearing aid to the correct position allowing them to participate more effectively in general conversation ordering goods or services listening to public performances etc.The PL1K3 is ideal for restricted person to person contact in areas such as banks post offices small meeting rooms reception desks open plan offices and ticket booths. The unit is supplied in arobustplastic storage case.Key FeaturesPortable lightweight design.Simple one button operation.Integral high-performance microphone.Excellent sound quality.Five years expected battery life under normal operatingcharging conditions.Auto shut-off facility user selectable for 10 30 or 60 minutes helps preserve battery life.Connection of the plug-top charger overrides the timer function to ensure the unit remains operational at all times.Unit can be used as normal whilst charging.Note this version of our portable loop amplifier does not include a wall-mounting storage shelf.Technical InformationType - PortableCoverage - 1.2m2 approx.Dimensions - W 271 x H 200 x D 77mm amplifier only 2.82kgInputs 2 x Mic one built-in mic. and one 3.5mm remote mic. socket for AMT or AMD micsIndicators - Power on input level charging required charging in progress audio warning of imminent shutdownControls - Onoff button adjust auto-shut off timer

GBP 345.96
1

C-Tec CFP708-2 CFP Two Wire 8 Zone AlarmSense Control Panel

C-Tec CFP708-2 CFP Two Wire 8 Zone AlarmSense Control Panel

C-Tec CFP Two Wire 8 Zone AlarmSense Control Panel - CFP708-2C-TECs LPCB certified two-wire CFP AlarmSense fire panel is designed to work with Apollos AlarmSense range of detectors call points sounders and beacons. Most conventional fire systems are designed to work with two pairs of wires per zone one pair for detection devices such as smoke detectors heat detectors and manual call points the other for alarm devices such as bells sounders or strobes. By using different voltage bands for quiescent and alarm states AlarmSense components can be connected to the same pair of supply wires.When powered and controlled by the CFP two-wire fire panel this reliable technology takes all the complexity out of fire alarm system design leading to quicker less expensive and more flexible installation. Indeed research shows an AlarmSense two-wire system can achieve a 20-25 reduction of labour over a standard four wire conventional system. AlarmSense devices are acceptable for BS 5839-1 and BS 5839-6 systems making them particularly useful for fire protection in Houses of Multiple Occupation HMOs.Key FeaturesLPCB certified to EN54 parts 2 and 4Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry to access level 22 4 or 8 AlarmSense zone circuits dependent on model purchasedFour conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSUWide range of engineering functions including zone test coincidence zone delay and non- latching zonesTwo on-board relays Fire and FaultTwo open-collector outputs Remote and ResetClass change and alert inputsInstaller-friendly design accommodates easy first fix and straightforward maintenanceAttractive flush or surface mountable plastic lid and enclosure - no bezel requiredLow quiescent currentMultiple indicatorsEnd of line units included one per zoneAncillary system expansion connections provided for up to eight two-wire repeaters one CFP761 network driver card required per system and optional CFP relay boardsSpace for two x 12V 3.3Ah VRLA batteries

GBP 272.59
1

C-Tec CFP704-2 CFP Two Wire 4 Zone AlarmSense Control Panel

C-Tec CFP704-2 CFP Two Wire 4 Zone AlarmSense Control Panel

C-Tec CFP Two Wire 4 Zone AlarmSense Control Panel - CFP704-2C-TECs LPCB certified two-wire CFP AlarmSense fire panel is designed to work with Apollos AlarmSense range of detectors call points sounders and beacons. Most conventional fire systems are designed to work with two pairs of wires per zone one pair for detection devices such as smoke detectors heat detectors and manual call points the other for alarm devices such as bells sounders or strobes. By using different voltage bands for quiescent and alarm states AlarmSense components can be connected to the same pair of supply wires.When powered and controlled by the CFP two-wire fire panel this reliable technology takes all the complexity out of fire alarm system design leading to quicker less expensive and more flexible installation. Indeed research shows an AlarmSense two-wire system can achieve a 20-25 reduction of labour over a standard four wire conventional system. AlarmSense devices are acceptable for BS 5839-1 and BS 5839-6 systems making them particularly useful for fire protection in Houses of Multiple Occupation HMOs.Key FeaturesLPCB certified to EN54 parts 2 and 4Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry to access level 22 4 or 8 AlarmSense zone circuits dependent on model purchasedFour conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSUWide range of engineering functions including zone test coincidence zone delay and non- latching zonesTwo on-board relays Fire and FaultTwo open-collector outputs Remote and ResetClass change and alert inputsInstaller-friendly design accommodates easy first fix and straightforward maintenanceAttractive flush or surface mountable plastic lid and enclosure - no bezel requiredLow quiescent currentMultiple indicatorsEnd of line units included one per zoneAncillary system expansion connections provided for up to eight two-wire repeaters one CFP761 network driver card required per system and optional CFP relay boardsSpace for two x 12V 3.3Ah VRLA batteries

GBP 226.68
1

C-Tec CFP Two Wire 2 Zone AlarmSense Control Panel - CFP702-2

C-Tec CFP Two Wire 2 Zone AlarmSense Control Panel - CFP702-2

C-Tec CFP Two Wire 2 Zone AlarmSense Control Panel - CFP702-2C-TECs LPCB certified two-wire CFP AlarmSense fire panel is designed to work with Apollos AlarmSense range of detectors call points sounders and beacons. Most conventional fire systems are designed to work with two pairs of wires per zone one pair for detection devices such as smoke detectors heat detectors and manual call points the other for alarm devices such as bells sounders or strobes. By using different voltage bands for quiescent and alarm states AlarmSense components can be connected to the same pair of supply wires.When powered and controlled by the CFP two-wire fire panel this reliable technology takes all the complexity out of fire alarm system design leading to quicker less expensive and more flexible installation. Indeed research shows an AlarmSense two-wire system can achieve a 20-25 reduction of labour over a standard four wire conventional system. AlarmSense devices are acceptable for BS 5839-1 and BS 5839-6 systems making them particularly useful for fire protection in Houses of Multiple Occupation HMOs.Key FeaturesLPCB certified to EN54 parts 2 and 4Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry to access level 22 4 or 8 AlarmSense zone circuits dependent on model purchasedFour conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSUWide range of engineering functions including zone test coincidence zone delay and non- latching zonesTwo on-board relays Fire and FaultTwo open-collector outputs Remote and ResetClass change and alert inputsInstaller-friendly design accommodates easy first fix and straightforward maintenanceAttractive flush or surface mountable plastic lid and enclosure - no bezel requiredLow quiescent currentMultiple indicatorsEnd of line units included one per zoneAncillary system expansion connections provided for up to eight two-wire repeaters one CFP761 network driver card required per system and optional CFP relay boardsSpace for two x 12V 3.3Ah VRLA batteries

GBP 182.66
1

C-Tec CL1UK Mini Counter Hearing Loop Kit 1.2m2

C-Tec CL1UK Mini Counter Hearing Loop Kit 1.2m2

C-Tec CL1UK Mini Counter Hearing Loop Kit 1.2m2Hearing loop systems allow hearing impaired people to hear more clearly. Most hearing aids have a T or MT switch which allows them to pick up the electromagnetic field generated by a hearing loop system. The hearing aid converts this signal into a sound suited to its users specific hearing requirements.Any person with a hearing aid positioned within or near the loop can hear the loop signal by switching their hearing aid to the correct position allowing them to participate more effectively in general conversation ordering goods or services listening to public performances etc.The C-Tec SigNET CL1UK mini counter induction loop system kit is the ideal high-quality stand-alone audio frequency induction loop system AFILS for a desk or counter application in a bank post office or ticket booth. The miniature loop amp generates a localised loop field ideal for one-to-one communication. The kit comes complete with loop amp power supply pre-formed counter loop microphone induction loop present sticker.Key FeaturesIdeal for banks post offices small meeting rooms reception desks ticket boothsand any other application requiring restricted or small area coverageGenerates a loop listening field of 4 sq.ft 1.2m2 Kit includes a compact CL1 mini-induction loop amplifier cw UL listed power supply an AMT microphone a TX121 pre-formed counter loop and AFILS available stickerAdjustable drive control level and line controls allows the amplifiers output stage to be set-up to suit the exact characteristics of the applicationMetal compensation control helps combat the frequency response problems caused by metal absorbing the magnetic fieldState-of-the-art audio processor features an automatic gain control which compensates for poor microphone techniques and helps suppress loud noises hisses and clicksDesigned to be free-standing or wall-mounted using the keyholes providedTechnical SpecificationsInduction Loop Type Wall mounting requires fixed mains wiring and a 25mm back boxCoverage 1.2m2 approx.Dimensions W 143 x H 83 x D 32mm 300g amplifier onlyInputs 1 x 3.5mm remote mic. socket 1 x LineOutreach socket max. 3 Outreach plates per ML1Indicators Input level power on loop drive meter.Controls Mic. input level line input level loop driveKit content ML1 amplifier AMT microphone TX2 pre-formed counter loop AFILS fitted sticker.

GBP 245.82
1

C-Tec NC910F Conventional 10 Zone Flush Master Call Controller

C-Tec NC910F Conventional 10 Zone Flush Master Call Controller

C-Tec NC910F Conventional 10 Zone Flush Master Call ControllerThe NC910FCall Controller is compatible with all 800 Series call points ceiling pulls infrared ceiling receivers monitoring points overdoor lights and remote sounders.Depending on how the Controller is configured and the devices connected to it Standard and Emergency calls can be indicated via its buzzer and zonal LEDs. Two buttons A and B are also provided to allow the user to Reset Mute or Accept standard calls as detailed below.Standard Calls when triggered by a calling device the Controllers internal buzzer sounds continuously and the relevant zone indicators illuminate steady.Pressing the Controllers Reset Button A if enabled cancels all standard calls.Pressing the Controllers Mute Button B if enabled silences the Controllers internal buzzer. However if a new call standard or emergency is triggered anywhere on the system the buzzer will resound.Alternatively instead of muting calls Button B can be configured as a CALL ACCEPT button.Pressing Call Accept sends a slow pulsing acknowledgement signal to overdoor lights and reset points cw sounders provided they are wired as shown on the example wiring diagram below. Should a new call standard or emergency be triggered anywhere on the system any zones in the acknowledgement state will revert to a standard call.Emergency Calls when triggered by a calling device the Controllers internal buzzer pulses and the relevant zone indicators flash. This level of call takes priority over standard calls and cannot be muted accepted or reset at the Controller. An emergency call can only be reset at the device from which it was triggered or via a reset point wired on the same zone.Key FeaturesCompatible with C-TECs entire range of 800 Series field devicesHoused in an attractive flush mounting plastic enclosure measuring just 214mm x 178mmTwo call levels - standard constant tone and emergency intermittent toneOptional mute and call acceptreset buttonsCall Accept functionality allows staff to send an intermittent call acknowledgment signal to calling zones to confirm help is on the way dependent on wiring and field devices usedIncludes a 12V 300mA PSU and 2 volt-free relay contacts which activate on a standard or emergency callInnovative slide-in labelling systemZones can be wired in 4 or 6 core 702 stranded security cableAdditional master controllers and expansion units available for use as repeaters on larger sitesOptional boxed PSUs cw with space for a 12V VRLA battery available for sites where a standby battery facility is required

GBP 228.82
1