2.367 results (0,14764 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Global Fire Equipment VALKYRIE-ASBLK Valkyrie AS Addressable Wall Sounder - Black

Global Fire Valkyrie ASB Addressable Red Wall Sounder Beacon

Global Fire Valkyrie ASI IP65 Addressable Red Sounder with Isolator

Global Fire Valkyrie ASBI IP65 Addressable Red Sounder Beacon with Isolator

Global Fire VALKYRIE-ASBWHT VALKYRIE Addressable Wall Mount Sounder Beacon White

Global Fire VALKYRIE-ASBBLK VALKYRIE Addressable Wall Mount Sounder Beacon Black

Global Fire Valkyrie ABI IP65 Addressable Red Beacon with Isolator

Global Fire VULCAN2-ABIBLK VULCAN 2 Addressable Base Beacon cw Isolator - Black

Global Fire VULCAN2-ABIBLK VULCAN 2 Addressable Base Beacon cw Isolator - Black

Global Fire VULCAN2-ABIBLK VULCAN 2 Addressable Base Beacon cw Isolator - BlackThe addressable VULCAN 2 A is available as an Addressable Beacon which may be field configured to operate in either SHADOW or AUXILIARY modes. There are also versions available incorporating a loop isolator. Up to 64 VULCAN 2 A Beacon device can be connected to a single Loop depending on Loop Loading. All VULCAN 2 A devices have dip-switch Address setting while Tone and Mode selection is via a jumper. There is also a potentiometer which may be used to adjust the sound level if required. Normally the VULCAN 2 A will be used in conjunction with a detector however a lid is available as an option for the VULCAN 2 A.Shadow Beacon A Shadow Beacon does not have an individual address thus freeing up addresses for more detection devices. Shadow Beacons do not report back to the control panel so their presence on the Loop is not monitored. Auxiliary Beacon When the VULCAN 2 A is configured as an Auxiliary device it shares the same address as the detector with which it is co-located. When operating in this mode the VULCAN 2 A monitors the Address loop for the command from the control Panel to the detector to illuminate its LED. When this command is received the VULCAN 2 A is also activated.If a Fire is confirmed the remaining sounders may be activated using the Evacuate command. This reduces the inconvenience to other guests in the event of a false alarm while at the same time giving early warning to the occupant of the room in the case of an actual Fire event. Pressing Sounder silence at the panel silences all active sounders. The maximum number of Auxiliary Beacons is 63 and they can be allocated between address 1 and 63.

GBP 61.48
1

Global Fire Vulcan 2 ASBI Addressable White Sounder Beacon with Isolator

Global Fire Vulcan 2 ASBI Addressable White Sounder Beacon with Isolator

Global Fire Vulcan 2 ASBI Addressable White Sounder Beacon with IsolatorThe addressable VULCAN 2 A is available as an Addressable SounderBeacon which may be field configured to operate in either SHADOW or AUXILIARY modes. There are also versions available incorporating a loop isolator. Up to 64 VULCAN 2 A SounderBeacon device can be connected to a single Loop depending on Loop Loading. All VULCAN 2 A devices have dip-switch Address setting while Tone and Mode selection is via a jumper. There is also a potentiometer which may be used to adjust the sound level if required. Normally the VULCAN 2 A will be used in conjunction with a detector however a lid is available as an option for the VULCAN 2 A.Shadow SounderBeacon A Shadow SounderBeacon does not have an individual address thus freeing up addresses for more detection devices. Shadow SounderBeacons do not report back to the control panel so their presence on the Loop is not monitored. Auxiliary SounderBeacon When the VULCAN 2 A is configured as an Auxiliary device it shares the same address as the detector with which it is co-located.When operating in this mode the VULCAN 2 A monitors the Address loop for the command from the control Panel to the detector to illuminate its LED. When this command is received the VULCAN 2 A is also activated. If a Fire is confirmed the remaining sounders may be activated using the Evacuate command. This reduces the inconvenience to other guests in the event of a false alarm while at the same time giving early warning to the occupant of the room in the case of an actual Fire event. Pressing Sounder silence at the panel silences all active sounders. The maximum number of Auxiliary SounderBeacons is 63 and they can be allocated between address 1 and 63.

GBP 50.70
1

Global Fire VULCAN2-ASBIBLK VULCAN 2 Addressable Base Sounder Beacon cw Isolator - Black

Global Fire VULCAN2-ASBIBLK VULCAN 2 Addressable Base Sounder Beacon cw Isolator - Black

Global Fire VULCAN2-ASBIBLK VULCAN 2 Addressable Base Sounder Beacon cw Isolator - BlackThe addressable VULCAN 2 A is available as an Addressable Beacon which may be field configured to operate in either SHADOW or AUXILIARY modes. There are also versions available incorporating a loop isolator. Up to 64 VULCAN 2 A Beacon device can be connected to a single Loop depending on Loop Loading. All VULCAN 2 A devices have dip-switch Address setting while Tone and Mode selection is via a jumper. There is also a potentiometer which may be used to adjust the sound level if required. Normally the VULCAN 2 A will be used in conjunction with a detector however a lid is available as an option for the VULCAN 2 A.Shadow Beacon A Shadow Beacon does not have an individual address thus freeing up addresses for more detection devices. Shadow Beacons do not report back to the control panel so their presence on the Loop is not monitored. Auxiliary Beacon When the VULCAN 2 A is configured as an Auxiliary device it shares the same address as the detector with which it is co-located. When operating in this mode the VULCAN 2 A monitors the Address loop for the command from the control Panel to the detector to illuminate its LED. When this command is received the VULCAN 2 A is also activated.If a Fire is confirmed the remaining sounders may be activated using the Evacuate command. This reduces the inconvenience to other guests in the event of a false alarm while at the same time giving early warning to the occupant of the room in the case of an actual Fire event. Pressing Sounder silence at the panel silences all active sounders. The maximum number of Auxiliary Beacons is 63 and they can be allocated between address 1 and 63.

GBP 79.55
1

Morley HLS-DOCBOX Document Box Grey

Global Fire VULCAN2-ASIBLK VULCAN 2 Addressable Base Sounder cw Isolator - Black

Global Fire VULCAN2-ASIBLK VULCAN 2 Addressable Base Sounder cw Isolator - Black

Global Fire VULCAN2-ASIBLK VULCAN 2 Addressable Base Sounder cw Isolator - BlackThe addressable VULCAN 2 A is available as an Addressable Sounder Beacon which may be field configured to operate in either SHADOW or AUXILIARY modes.There are also versions available incorporating a loop isolator. Up to 64 VULCAN 2 A Sounder Beacon device can be connected to a single Loop depending on Loop Loading.All VULCAN 2 A devices have dip-switch Address setting while Tone and Mode selection is via a jumper.There is also a potentiometer which may be used to adjust the sound level if required. Normally the VULCAN 2 A will be used in conjunction with a detector however a lid is available as an option for the VULCAN 2 A.Shadow Sounder Beacon A Shadow Sounder Beacon does not have an individual address thus freeing up addresses for more detection devices.Shadow Sounder Beacons do not report back to the control panel so their presence on the Loop is not monitored.Auxiliary Sounder Beacon When the VULCAN 2 A is configured as an Auxiliary device it shares the same address as the detector with which it is co-located. When operating in this mode the VULCAN 2 A monitors the Address loop for the command from the control Panel to the detector to illuminate its LED.When this command is received the VULCAN 2 A is also activated. If a Fire is confirmed the remaining sounders may be activated using the Evacuate command.This reduces the inconvenience to other guests in the event of a false alarm while at the same time giving early warning to the occupant of the room in the case of an actual Fire event.Pressing Sounder silence at the panel silences all active sounders. The maximum number of Auxiliary Sounder Beacons is 63 and they can be allocated between address 1 and 63.

GBP 57.08
1

C-Tec BF357 Document Key Box

C-Tec BF333CTDR 24V Addressable SounderBeacon - Deep Base - Red

Crowcon M07211 Vortex Installation Maintenance and Operating Instruction Manual

Gent S4-34741-03 34740 Parallel Bracket and Base

STI STI-7511A Enclosure with Back Box A and Thumb Lock

STI STI-7511B Enclosure with Back Box B and Thumb Lock

STI STI-7511C Enclosure with Back Box C and Thumb Lock

FireClass FC460PC Multi-Sensor Smoke Heat and Carbon Monoxide Detector