12.366 results (0,18041 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Nittan EV-HIOP-BCN-SCI High Output Beacon VAD with White Flash and Isolator

Nittan EV-HIOP-SB-SCI High Output Sounder Beacon with White Flash and Isolator

Aritech TS806-03 Smoke and Cordless Heat Detector Tester Test Kit

Aritech TS806-03 Smoke and Cordless Heat Detector Tester Test Kit

Aritech TS806-03 Smoke and Cordless Heat Detector Tester Test KitThe TS806-03 is an economical kit with testing tools in a convenient kit format.The TS806-03 test and service equipment allows the user to rapidly and easily test practically all smoke detectors. Lightweight and rugged materials ensure long life and allow servicing up to heights of 6 m using extension elements. The tools have an integrated design providing a complete solution with the minimum number of components.Included in the TS806-03 is a touch sensitive aerosol dispenser which is on a swing frame. The robust injection-moulded design allows it to withstand the rigours of everyday use. It allows the test gas canister SC008 or SC008CO to be pre-pressed so that only a small upward pressure is needed to release the gas. The transparent cup allows the user to see the illuminated LED of the activated detector. The dispenser and patented diaphragm conserves the aerosol and detector testing is efficient and fast using a minimum amount of test gas.The test aerosol is the result of an extensive two year research programme providing the most efficient and safest way to test both ion and photo smoke detectors. With a minimum impact to health safety and the environment the non-toxic non-flammable particles allow fast response and clearing times and leaves smallest amount of residue. No damage to the detector plastic and components is also ensured.The kit contains1 x Fibre-glass telescopic pole of 4.5 m1 x Universal detector removal tool1 x Aerosol smoke dispenser1 x Cordless heat detector heat unit2 x Battery batons1 x Fast charger1x Protective carrying storage bag

GBP 2099.15
1

System Sensor Agile Wireless Optical Smoke Detector 22051E-RF-26

Aritech ACI420 OSDP Reader Slim Design Mifare Desfire EV123 CSN amp Bluetooth IndoorOutdoor

Aritech ACI421 Osdp Reader Standard Design Mifare Desfire Ev123 CSN amp Bluetooth IndoorOutdoor

Carrier VV600PS1 Seismic Detector For Safe And Vault ANPI

Carrier VV600PS1 Seismic Detector For Safe And Vault ANPI

Carrier VV600PS1 Seismic Detector For Safe And Vault ANPIThe VV600 Plus series seismic detectors are designed to detect attempts to break into vaults safes night deposit boxes automatic teller machines ATMs and other reinforced physical areas such as data storages and filing cabinets. These seismic detectors react to the characteristic vibration patterns of all breaking-and-entering tools such as hammers drills diamond saws hydraulic pressure tools and thermal tools like welding torch and thermal lance. They sense vibrations that occur within a 3-to-14-meter radius of where they are mounted depending on the material and design of the protected object.At the same time the seismic detectors allow for normal human activity around the protected area without the risk of creating unwanted alarms. To achieve this high level of accuracy each detector features three detectors in one. All three channels counting integration and explosion analyse the signal frequencies duration and amplitude in order to differentiate between random environmental disturbances and real intruder attack. The end result is detectors with excellent detection and false alarm immunity.The VV600 Plus series provides two different test functions automatic or manual activated. You can choose between internal test of the detector electronics or by using the test transmitter VT705P do a functional test of the detector and its physical contact to the protected object. A complete range of accessories is provided for all kinds of applications to achieve the highest security.Key FeaturesDetects all known methods of attacksAdvanced signal processing differentiates between ambient noise and real attacksExtremely low current drawTwo options of testingAdjustable sensitivityFull-scale tamper protectionComplete line of accessoriesEasy to install

GBP 189.83
1

Howler PLEXTENDIPOLEHD Prolink Extendipole cw Heat Detector Detector Excludes Sounder And VID

Howler PLEXTENDIPOLEHD Prolink Extendipole cw Heat Detector Detector Excludes Sounder And VID

Howler PLEXTENDIPOLEHD Prolink Extendipole cw Heat Detector Detector Excludes Sounder And VIDWhen it comes to the positioning of fire safety equipment it can be a big challenge on some construction sites right We know that hard-wired fire alarm detection is the least expensive option initially however the cost of cables cable-routing and repairing cables damaged by well-meaning site personnel works out extremely costly. On the other hand the more expensive wireless fire alarm detectors though free of cables still need fixing to the ceilings and this is not always an option in listed buildings on finished surfaces or where the detector needs relocating as the project progresses. But Howler is here to helpEnter the Howler ExtendiPoleKey FeaturesFirst developed in response to a clients needs during 2012-13 our latest upgraded design is the result of over five years of extensive research on-site testing and product refinementThe detector is hard-wired to the Howler ProLink radio-link alarm combining the best of both wired and wire-free worldsThe ProLink control panel can pinpoint which unit has been activatedThe height of the ExtendiPole is infinitely variable up to 4 metres giving flexibility of optimal positioningExtension and retraction of the pole is easy and quick allowing for rapid adjustment and relocation as requiredThe ExtendiPole is air-cushioned to prevent pinch hazards and equipment damageTough curly cable keeps itself out of the way preventing damageDetectors are available as either smoke or heat operatedThe ExtendiPole is available as an option on all SafetyHub FirePostsPlease note Additional shipping charges apply to this product.

GBP 452.76
1

Howler PLEXTENDIPOLESD Prolink Extendipole cw Smoke Detector Detector Excludes Sounder And VID

Howler PLEXTENDIPOLESD Prolink Extendipole cw Smoke Detector Detector Excludes Sounder And VID

Howler PLEXTENDIPOLESD Prolink Extendipole cw Smoke Detector Detector Excludes Sounder And VIDWhen it comes to the positioning of fire safety equipment it can be a big challenge on some construction sites right We know that hard-wired fire alarm detection is the least expensive option initially however the cost of cables cable-routing and repairing cables damaged by well-meaning site personnel works out extremely costly. On the other hand the more expensive wireless fire alarm detectors though free of cables still need fixing to the ceilings and this is not always an option in listed buildings on finished surfaces or where the detector needs relocating as the project progresses. But Howler is here to helpEnter the Howler ExtendiPoleKey FeaturesFirst developed in response to a clients needs during 2012-13 our latest upgraded design is the result of over five years of extensive research on-site testing and product refinementThe detector is hard-wired to the Howler ProLink radio-link alarm combining the best of both wired and wire-free worldsThe ProLink control panel can pinpoint which unit has been activatedThe height of the ExtendiPole is infinitely variable up to 4 metres giving flexibility of optimal positioningExtension and retraction of the pole is easy and quick allowing for rapid adjustment and relocation as requiredThe ExtendiPole is air-cushioned to prevent pinch hazards and equipment damageTough curly cable keeps itself out of the way preventing damageDetectors are available as either smoke or heat operatedThe ExtendiPole is available as an option on all SafetyHub FirePostsPlease note Additional shipping charges apply to this product.

GBP 452.76
1

Aritech VV602-PLUS Night Safe and ATM Seismic Detector Programmable

Aritech VV602-PLUS Night Safe and ATM Seismic Detector Programmable

Aritech VV602-PLUS Night Safe and ATM Seismic Detector ProgrammableThe VV602 seismic detector is designed to detect attempts to break into night deposit boxes automatic teller machines ATMs and other reinforced physical areas such as data storages and filing cabinets. This seismic detector reacts to the characteristic vibration patterns of all breaking-and-entering tools such as hammers drills diamond saws hydraulic pressure tools and thermal tools like welding torch and thermal lance.It will sense vibrations that occur within a 3 to 14 meter radius of where it is mounted depending on the material and design of the protected object.At the same time this detector will allow for normal human activity around the protected area without the risk of creating unwanted alarms. To achieve this high level of accuracy the detector features three detectors in one.All three channels counting integration and explosion analyse the signal frequencies duration and amplitude in order to differentiate between random environmental disturbances and real intruder attack. The end result is detectors with excellent detection and false alarm immunity.The VV600 Plus series provides two different test functions automatic or manual activated. You can choose between internal test of the detector electronics or by using the test transmitter VT705P do a functional test of the detector and its physical contact to the protected object. A complete range of accessories is provided for all kinds of applications to achieve the highest security.Key FeaturesDetects all known methods of attacksAdvanced signal processing differentiates between ambient noise and real attacksExtremely low current drawTwo options of testingAdjustable sensitivityFull-scale tamper protectionComplete line of accessoriesEasy to install

GBP 143.44
1

Aritech VV600-PLUS Vault And Safe Seismic Detector - Programmable

Aritech VV600-PLUS Vault And Safe Seismic Detector - Programmable

Aritech VV600-PLUS Vault And Safe Seismic Detector - ProgrammableThe VV 600 Plus series seismic detectors are designed to detectattempts to break into vaults safes night deposit boxes automaticteller machines ATMs and other reinforced physical areas such asdata storages and filing cabinets. These seismic detectors react to thecharacteristic vibration patterns of all breaking-and-entering tools suchas hammers drills diamond saws hydraulic pressure tools andthermal tools like welding torch and thermal lance. They sensevibrations that occur within a 3 to 14 meter radius of where they aremounted depending on the material and design of the protectedobject.Excellent false alarm immunityAt the same time the seismic detectors allow for normal human activityaround the protected area without the risk of creating unwantedalarms. To achieve this high level of accuracy each detector featuresthree detectors in one. All three channels counting integration andexplosion analyse the signal frequencies duration and amplitude inorder to differentiate between random environmental disturbances andreal intruder attack. The end result is detectors with excellent detectionand false alarm immunity.Testing accessoriesThe VV 600 Plus series provides two different test functions automaticor manual activated. You can choose between internal test of thedetector electronics or by using the test transmitter VT705P do afunctional test of the detector and its physical contact to the protectedobject. A complete range of accessories is provided for all kinds ofapplications to achieve the highest security.Key FeaturesDetects all known methods of attacksAdvanced signal processing differentiates between ambient noise andreal attacksExtremely low current drawTwo options of testingAdjustable sensitivity 5 steps of approx. 6 dB eachFull-scale tamper protectionComplete line of accessoriesEasy to installTest output screw no. 4 for measuring ambient noise level

GBP 135.13
1

Aritech ACI420-PIN-W Mifare Card Reader EV1 23 With Pin Keypad Slim Design BLE Wiegand

System Sensor 22051E-RF-26 Agile Photo Detector

Aritech ACI421-PIN OSDP Reader With Keypad Standard Design Mifare Desfire Ev123 CSN amp Bluetooth IndoorOutdoor

Aritech ACI420-PIN OSDP Reader With Keypad Slim Design Mifare Desfire Ev123 CSN amp Bluetooth IndoorOutdoor

Carrier FE371-N Magnetic Lock 5400N - MegaLED And Relay

Carrier FE323-N Magnetic Lock 2430N - MegaLED And Relay

Notifier M721E Analogue Addressable Dual Input Monitor and Single Output Relay Module

Notifier M721E Analogue Addressable Dual Input Monitor and Single Output Relay Module

Notifier M721E Analogue Addressable Dual Input Monitor and Single Output Relay ModuleThe M721E is designed for use with any Notifier protocol fire alarm control panel.Comes complete with end of line resistors plug-in screw connections direct decade address entry and tri-colour LEDs complete with Isolator.The newly designed platform of M700 family of InputOutput modules completes the NFXI line of wired spot detectors with unaltered family feeling and undisputed continuity.The new M700 look and feel combine maximum reliability with top-end functionality all enriched by a cutting-edge modern design.Single and multi-way models are available within the renewed mechanical package reducing both the cost of installation and the mounting space required.Their unique mechanical design allows each module to be mounted in either a common wall box on a DIN rail or its dedicated enclosure. The DIN rail mounting option is possible thanks to smart DIN brackets directly built-in the enclosure. Irrespective of the mounting methods chosen the address switch is always visible and accessible for selection.Each module has built-in short circuit protection for the communications loop however to increase application flexibility the isolators can be selecteddeselected on an individual module basis.To help technicians in the maintenance and fault-finding process light pipes have been enlarged to increase visibility even in the most challenging space constrained application. Both the status LED and the rotary switch selection can be viewed on the two sides without having to remove the cover of the surface mounting box.The multi-colour status LED provide diagnostic information regarding the status of each individual inputoutput. For ease of installation testing and maintenance modules have been equipped with quick connectors. The renovated aesthetics offers data finely engraved on the enclosures surface by laser for lifetime durability and resistance to degradation.

GBP 150.07
1

Aritech ATS1180M Secure MF Ev1 Slim Design

System Sensor 22051EI-26 Photoelectric Optical Smoke Sensor with Isolator

System Sensor 22051E-26 Photoelectric Optical Smoke Sensor

Gent S4T-780-S S4 SELF TEST Heat Sensor and Sounder

Gent S4T-780-S S4 SELF TEST Heat Sensor and Sounder

Gent S4T-780-S S4 SELF TEST Heat Sensor and SounderThe GENT S4T-780-S Self-Test Heat Sensor with Integrated Sounder has a new IP21 external moulding new detector chamber design and a dual microprocessor PCB. This design delivers even better smoke detection and voice storage capacity. In addition the award-winning Self-Test feature allows both the heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Enables discrete functional testing and visual inspection of the fire alarm system by reducing the engineer toolset to just a mobile device phone or tablet. No more impact on building occupiers Tests both the heat and smoke sensors by heating the thermistor and introducing small amounts of smoke into the detection chamber Gently blows the smoke out of the detection chamber and smoke entry points to ensure they are not blocked Flexible testing options allow the engineer to test in different ways single device detection zone loops panels Allows up to 6 devices to be tested at once per loop and any number of loops can be tested simultaneously making the functional testing incredibly fast Device testing is fast enough to allow up to 4 functional tests to be performed per year for the lifespan of the device Eliminates all access issues when detector testing ensuring 100 functional testing is achieved Allows the system to remain active whilst testing as each detector is only offline for 60 seconds and outputs are not generated Any fires detected outside of the devices performing Self-Test will stop the Self-Test process and operate the fire systems Cause Effect Allows the engineer to easily locate the detector using the App and BLE to check the device number label zone description and detector type Allows simple device updates to be performed through the App including the correction of inaccurate device labels and loop mapping The app and BLE handshake verifies that the engineer has been within visual inspection range Optional Inspection prompt LEDs on the device let the engineer know what Self-Test devices need to be visually inspected and will automatically turn off when the visual inspection is complete Engineers can spend more time digitally capturing non-compliance issues and advising how to resolve them. This includes any issues causing false alarms Test Fire LED option in the App allows the fire LED to be tested a pending BS5839-1 testing requirement. This feature can additionally confirm that they are inspecting the correct device The CLSS App allows the engineer to simulate a fire and test the Cause Effect logic The CLSS App also allows the Cause Effect to be triggered through a successful Self-Test operation allowing a witness test to be performed using real smoke

GBP 141.83
1

Ziton Conventional Fire and Extinguishing Panel EN12094 3 Zone ZP1-X3E-03

Ziton Conventional Fire and Extinguishing Panel EN12094 3 Zone ZP1-X3E-03

Ziton Conventional Fire and Extinguishing Panel EN12094 3 Zone ZP1-X3-03ZP1 fire control panels offer state of the art architecture in configurations that deliver an uncomplicated solution for small to mid-sized conventional applications. They feature an attractive contemporary design that fits with any decor. The gently curved door front offers a distinctive flair. Operator controls are inset in a striking blue lexan. With support for multiple lines of conventional detectors and accessories these quick-to-configure systems offer versatility that benefits building owners and installationmaintenance companies alike.The ZP1-X3 is a conventional fire alarm and extinguishing control panel. It is supplied in local language with 3 fire zones that support up to 32 devices per zone. These zones may be configured for extinguishing in single zone or double zone configuration in any combination of zones. In addition the panel offers supervised outputs for first stage notification second stage notification as well as optical warning indicators and actuator activation. Standard relay outputs are provided for EN54 compliance and system status notification as well as multiple inputs for system control.The panels support 2 types of auxiliary relay boards one with 4 standard relays and one with 4 supervised relays. With these boards the panel outputs may be expanded with up to 16 additional outputs.The ZP1-X3E supports class A redundant ring and B standard bus networking with up to 32 nodes including conventional and addressable panels and repeaters via an optional network interface. This allows full remote control and inputs to and from other nodes in the system providing superior flexibility in system organisation and planning.Key FeaturesModern elegant designEasy removable parts for quick and easy installationNormal head-out supervision support per zoneThree detection zones Single zone double zone or any combination of zones configurable for release6 Pre-configured relays and 8 supervised inputs for extinguishing controlConfigurable fire routing sounder extinguishing reset and door monitoring delaysConfigurable Hold Mode type-A or type-B Sounders configurable for pulsing or continuous operationExtinguishing agent flow confirmationContinuous or resettable 24 VDC auxiliary suppliesAuxiliary standard supervised relay output supportDefault support for special functions such as - EN54 compliant user access levels - Basic Advanced level configuration - mixed zones - front panel diagnostics with test disable control - one-man walk testRedundant networking to ZP1 conventional and ZP2 addressable nodesIntrinsically safe and EN54-13 zone support

GBP 376.19
1