11 results (0,16568 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Aico SAB300R 230V Xenon Strobe with Red Lens

Aico SAB300C 230V Xenon Strobe with Clear Lens

Aico Ei1529RC Alarm Control Switch

Aico Ei1529RC Alarm Control Switch

Aico Ei1529RC Alarm Control SwitchThe Ei1529RC is a remote control switch that runs on 230V AC mains power. It is designed for use with 2100 160RC and 140RC series smoke and heat alarms and 260RC series carbon monoxide alarms.It increases the flexibility and user friendliness of the alarms by allows the user to remotely Locate Hugh and Test the alarms in the systemLocate The source of the alarmHush any nuisance alarmsTest the alarm systemMains Check provides warning of a mains failureKey FeaturesInstall as part of the system to get more control over your alarmsMains poweredHard wired interconnectionTest Locate and SilenceCompatible with 3000 Ei2110e Multi-Sensor Fire Alarm 160e Series alarms 140RC Series alarms and hard wired interconnected Carbon Monoxide alarmsCompiles with electrical safety requirements EN61000-6-12007 Et EN61000-6-22005 EMC Directive and EN600652001 A122011 Low voltage directiveCarries the CE mark to indicate conformance to Low Voltage and Electromagnetic Compatibility DirectivesWall mounted for ease of use can be fixed with surface mount box supplied or will fit a standard recessed box not suppliedSuitable for siting at any convenient point in the property. Up to 4 x Ei1529RC switches can be installed in a hardwired system along with a maximum of 16 x 3000 2110e 160e or 140RC Series smoke and heat alarms or 261ENRC Carbon Monoxide alarmsThe unit incorporates 3 switches marked Locate Test and Hush. These provide control features as detailed below and a mains check function as detailed below

GBP 48.71
1

Aico Relay Module with 5A Relay Mounts under 2100 160RC amp 140RC Alarms Ei128R

Aico Relay Module with 5A Relay Mounts under 2100 160RC amp 140RC Alarms Ei128R

Aico Relay Module with 5A Relay Mounts under 2100 160RC 140RC Alarms Ei128RThe Ei128R is a mains powered Relay Module that triggers external devices such as a strobe light or telecare deviceif the alarmsin the propertyactivate.Compatible with the3000Ei2110e Multi-Sensor Fire Alarm160e Seriesalarms and the 140RC SeriesThe Module has additional trunking knock outsto make as easy to install as possibleand is designed to fit underneath the space of easy-fit or RadioLINK base. However a cover is supplied if needed and containsa set of volt-free contacts as standard.The Relay module can beconfigured to give a 230V output or a 24V output using an external 24V supply.Operation of the Ei128ROn receiving a signal from the alarm system the relay contacts will be operated causing a signal to be sent to the device to which it is connected.The Ei128R can be used to switch into a range of devices ranging from indicating lights to magnetic door handles.The module can be switched to give a pulse output or continuous output for different applications.Technical SpecificationThe Relay is designed to operate whilst the alarm system is sounding to signal ancillary devices such as door closers extractors remote sounders etc. When any of the interconnected alarms sound the signal will cause the relay contacts to switch.The Relay is mains powered and operates on receipt of a signal from the interconnect line of a smoke heat or CO alarm. The relay does not operate if mains power is not present.Volt free contacts Normally Open or Normally Closed rated up to 240V AC5 Amps making it suitable for use with a wide range of AC or DC voltages.The Ei128R is designed for siting under one of the smokeheat alarms listed above. However a cover is supplied if installing remotely or with 260 series CO alarms.More than one Relay can be used in a set of interconnected alarms on the condition that no more than 12 units are used in the system 1 x Ei128R counts as one unit.Fitted with a 4 way connector block for ease of wiring.The relay can be set for Continuous or Pulse operation by operation of a manual switch when in Pulse operation mode the relay contacts will automatically switch back to their original state after 5 seconds.Features 3 x 25mm trunking knockouts for surface wiring and centre knockout for recess wiring.Dimensions of unit 135mm diameter x 20mm depth.Weight inclusive of packaging 170g.Manufactured in Ireland.Key FeaturesFor use with the 2100 160RC and 140RC series alarmsVolt free contacts as supplied for multiple useCan be configured to switch a 230V or 24V deviceTrunking knock-outs for easy and neat wiringAdditional connectors for ease of wiringContinuous or pulse operationFits discreetly behind any smoke heat alarm5 Year Guarantee

GBP 43.28
1

Aico Ei171RF RadioLINK Flashing Strobe with Rechargeable Back-up

Aico Ei171RF RadioLINK Flashing Strobe with Rechargeable Back-up

AicoEi171RFRadioLINK Flashing Strobe with Rechargeable Back-upThe Ei171RF is a RadioLINK alarm accessory that is designed to give warning to the deaf and hard of hearing if their alarm system has activated. It consists of a mains powered strobe light with a rechargeable battery back-up. This strobe has been designed specifically for daytime rooms as a visual indicator with a specially designed lens for wide-angle light output.For protection in a bedroom we recommend the Ei170RF alarm kit as this combines a strobe light and a vibrating pillow pad for extra warning.This Strobe Light is compatible with the 3000 Multi-Sensor Fire Alarm Ei2110e 160e Series alarms and 140RC Series smoke and heat alarms along with any interconnected Carbon Monoxide alarms. This kit links into the alarm system using RadioLINK wireless interconnection technology making it easier to add into a system and causing less disruption to the occupants on installation.As with other RadioLINK products the Ei17iRF Strobe for the Deaf and Hard of Hearing will need to be linked into the alarm system or House Coded.Key FeaturesFor use with 3000 2110e 160e and 140RC Series smoke and heat alarms when used with a RadioLINK base RadioLINK module or a SmartLINK module and RadioLINK Carbon Monoxide CO alarms it can also be used with all other RadioLINK devicesancillariesEliminates the need for any cabling between the Ei170 RF and the smoke heat andor CO alarms used in the systemRequires 230V AC 50Hz mains power supplyBuilt-in high-intensity Xenon strobe flash rate 0.8Hz with a wide light output angleBuilt-in long life sealed lead acid rechargeable batteryMains transformer is mounted in separate and hard-wired to the strobe unit with 4m of low voltage cable. Supplied with 2m of mains cable and pre-wired 13 amp plug with a 3 amp fuseIntegrated Test button on the front of the unit. Pressing this checks strobe and control circuitry and also send out a RadioLINK alarm signal to other units in the systemUp to 12 RadioLINK units can be used in one system. For larger systems contact our Technical Department for guidanceAn optional additional strobe Ei178 is available for providing warning in additional rooms The Ei178 is supplied with 10m of pre-wired cable and plug for connection to one of the auxiliary socketsThe product is CE marked to indicate conformance to directives EMC 89336EEC tested to EN50130-4 Low Voltage 7323EEC tested to EN60065 RTTE 19995EC tested to EN300220-2V2.1.1Designed for wall or surface mountingDimensions Control box 195mm x 125mm x 75mm. Mains adapter 60mm x 50mm x 90mmWeight Control box 770g. Mains adapter 600gAmbient Temperature Range 4C to 40C. Humidity Range 0 to 90 relative humidity5-year guarantee

GBP 245.27
1

Aico MCP401RC 230v Manual Call Point with Rechargeable Back-up

Aico MCP401RC 230v Manual Call Point with Rechargeable Back-up

Aico MCP401RC 230v Manual Call Point with Rechargeable Back-upThe MCP401RC Manual Call Point is an emergency device that when activated triggers all the alarms on the connected system. This Call Point is mains powered and can be hard wired interconnected anywhere into the alarm system.The front plate is made from a non-breaking plastic that means if the call point is used you can simply reset the plate rather than having to replace it.When the Manual Call Point is activated it will trigger all alarms causing them to sound.When the unit is reset using the key provided it will automatically cancel the interconnect signal and the alarms will stop sounding.Key FeaturesA unique Manual Call Point that mimics the feel of breaking glass whilst offering the benefits of a re-settable operating element230V AC mains powered with tamper proof rechargeable Lithium cells designed to last 10 years the life of the unit whilst providing up to 2 months operation in the event of mains failureSuitable for use with 2110e 160e and 140RC Series smoke heat and CO alarms up to a maximum of 20 including the MCP401RCEasily installed via a 3-core connection Live Neutral and interconnect the same as the smoke heat and CO alarms using 0.75mm or 1.00mm cableWhen the front plate is pressed a visible warning flag will appear to indicate it has been activated.Simple key to reset the unit no broken glassSupplied with 35mm deep surface mounting box rest key and all screws and fixingsDimensions 85 x 85 x 60mmWeight inclusive of packaging 230g5 year guarantee

GBP 45.18
1

Aico Relay Module with 5A Relay amp Rechargeable Back-up Ei128RBU

Aico Relay Module with 5A Relay amp Rechargeable Back-up Ei128RBU

Aico Relay Module with 5A Relay Rechargeable Back-up Ei128RBUThe Ei128RBU is a Relay Module that runs on a 230V AC mains power and has built-in tamper-proof Lithium cells that act as a battery back up in the event of mains failure. These rechargeable lithium cells are designed to have a 10-year life and outlast the life of the module itself whilst providing up to 2 months of operation without mains power.The Module has a set of Volt free contacts Normally Open and Normally Closed as standard but can be configured to give a 230V output or a 24V output using an external 24V supply.Any combination of30002110e160e 140RC or 260RC Series alarms can be used up to 12 including the Relay.The Module is designed to fit underneath any smoke or heat alarm. However a cover is supplied if there is a need for siting the unit remotely.The Module has additional trunking knock outs for ease of wiring.The Module can give a Continuous or pulse output. The pulse output will switch back the Relay contacts to their original state after 5 seconds operation.Operation of the Ei128RBUOn receiving a signal form the alarm system the Relay contacts will be operated causing a signal to be sent to the device to which it is connected.The Ei128RBU can be used to switch into a range of devices ranging from warden call systems to panel systems.When modified for a 230V or 24V output they can operate a range of different devices.The Module can be switched to give a pulse output or continuous output for different applications.Technical Specification The Relay is designed to operate whilst the alarm system is sounding to signal devices such as panels warden call systems nurse call systems etc. When any of the interconnected alarms sound the signal will cause the relay contacts to switch.The Relay runs on 230V AC mains power and has built in tamper proof Lithium cells that act as a battery back up in the event of mains failure. These rechargeable Lithium cells are designed to have a 10 year life and outlast the life of the module itself whilst providing up to 2 months of operation without mains power. It operates on receipt of a signal form the interconnect line of a smoke heat or CO alarm.Volt-free contacts Normally Open or Normally Closed rated up to 240V AC 5 Amps making it suitable for use with a wide range of AC or DC voltages.Any combination of 3000 2110e 160e 140RC or 260RC smoke heat or CO alarms can be interconnected to a maximum of 12 units in total 1 x Ei128RBU counts as one unit.The Ei128RBU is designed for siting under one of the smokeheat alarms listed above. However a cover is supplied if installing remotely or with 260 series CO alarms.More than one Relay can be used in a set of interconnected alarms on the condition that no more than 12 units are used in the system 1 x Ei128RBU counts as one unit.Fitted with a 4 way connector block for ease of wiring.The Relay can be set for continuous or pulse operation through a manual switch when in pulse operation mode the Relay contacts will automatically switch back to their original state after 5 seconds.Features 3 x 25mm trunking knockouts for surface wiring and centre knockout for recess wiring.Dimensions of unit 135mm diameter x 20mm depth.Weight inclusive of packaging 265g.Manufactured in Ireland.Key FeaturesFor use with 2100 160RC and 140RC alarmsRechargeable lithium battery back-upVolt free contacts as supplied for multiple useCan be configured to switch a 230V or 24V deviceTrunking knock-outs for easy and neat wiringAdditional connectors for ease of wiringContinuous or pulse operationFits discreetly behind any smoke heat alarm5 Year Guarantee

GBP 71.82
1

Aico RadioLINK Panel Interface Ei413

Aico RadioLINK Panel Interface Ei413

Aico RadioLINK Panel Interface Ei413The Ei413 is a RadioLINK Panel Interface Module that provides an interface between RadioLINK alarms and accessories and fire alarmsecurity alarm panels. The module will decode aFire Carbon Monoxide and fault signals from RadioLINK devices and activate the Panel accordingly and will also work the other way activating the domestic alarms if it receives a signal from the Panel.The module is powered either directly from the Panel Systemor from an external source.Operation of the Ei413 RadioLINK Panel Interference ModuleOn receiving a Volt-free switched hardwired signal from the panel the module will transmit a RadioLINK alarm signal to activate the alarms in the systemIf a fire alarm has activated the module will recognise the signal as a fire and switch the relevant contacts to activate the panelIf a Carbon Monoxidealarm has activated the module will recognise the signal as a Carbon Monoxideleak and switch the relevant contacts to activate the panelTechnical SpecificationEliminate the need for any cabling between the Ei413 and the smokeheatCO alarms used in the system.The Ei413 is conformant to EN300220-1 RF Performance in accordance with EN300220-2 and EN301489-1 EMC referencing EN301489-3.The unit is powered from the alarm panel and requires 11 to 30VDC. Unit current rating 15mA Standby 60mA Alarm Max.The unit has three sets Normally Open Normally Closed and Common of built-in wiring contacts for connection to the panel rated at 30V 1 Amp. On the contacts closing the unit will dependent on which set of contacts are connected indicate a fire CO leak or fault to the panel. The unit also has a Normally Open volt-free set of contacts to link from the panel to it so if the panel is activated the unit will transmit a RadioLINK signal to the alarms in the system to activate them they will sound.Radio frequency 868MHz band in accordance with RTTE Directive 19995EC this band has been designed for use with security products and only allows a 1 duty cycle so continuous transmission and interference from external sources is extremely remote and would be illegal.Up to 12 RadioLINK units can be used in one system. Range may be a limiting factor.RF Range The type of building will be the major limiting factor e.g. the number and type of wallsceilings that the radio signal has to pass through. As a guide 30m should be the maximum distance between any of the RadioLINK units in the system.Units are in factory code when received they will communicate with each other. They must be House Coded to eliminate the risk of adjacent properties communicating with each other. After House Coding they will only communicate with other RadioLINK units coded at the same time.House Code Operate the House Code Switch on all RadioLINK units in the system see the instructions supplied with the other RadioLINK units being used. The LED indicator on the front cover of the Ei413 will flash blue slowly this indicates that it is transmitting its unique serial number to all other RadioLINK units in House Code. After a short time the unit will flash to indicate the number of units in the system 2 flashes 2 units 3 flashes 3 units etc.. The Ei413 will return to normal standby mode automatically after 15 minutes. Pressing the House Code Switch again will return it to normal standby immediately.Designed for surface mounting or can be fitted into certain alarm panels provided the casing is not a metallic construction which may restrict RF signals.Dimensions 88mm x 88mm x 28mm.Weight 150g.Ambient Temperature Range 0C to 40C.5 year guarantee.Manufactured in Ireland.

GBP 76.93
1

Aico EI1000G SmartLINK Gateway - Mains with Lithium Back-up

Aico EI1000G SmartLINK Gateway - Mains with Lithium Back-up

Aico EI1000G SmartLINK Gateway - Mains with Lithium Back-upThe SmartLINK Gateway is designed for use with the Aico RF devices. It provides a mechanism to transfer information from the RF network to a portal over the GSM network.It is mains powered with a rechargeable battery backup that can provide up to 72hrs of power supply in case of mains failure.Connected devices events are processed by the Gateway as they occur and cover events such asFire AlarmCO level detected High Medium LowButton TestMains Absent FaultHead OKHead RemovedEnd of lifeTo ensure the safety of the data it is encrypted in both directions during transmission using AES128 encryption.In addition for ease of installation the SmartLINK App available on Android iOS provides a step-by-step guide for the installation of the Gateway and the Aico RF devices.All data sent is accessible from a web portal where alerts can be set up to be delivered by email or SMS. Reports can also be run from the web portal to facilitate the management of the Alarms fitted.The data on the portal is securely stored and is only available to the associated client.Key FeaturesEnables remote management of RF AlarmsReceives RF specific data from RF devicesTransmits data over GSM networkNot GSM provider dependentBidirectional data encryptionUnique House Coding featureEasy setup and configurationCompatible with SmartLINK RadioLINKProvides specific data from radio frequency devicesHeart beat every 12 hours which gets sent to the portalTo connect to your smart device and portal you simply scan QR codes on alarm and moduleEasy installation and configurationTransmits data over GSM networkUnique house coding featureData upload 2G GSM network roaming sim card supplied no subscription necessaryFrequency 868MHz band 1 duty cyclePower usage 40mAVoltage 230VBattery back-up Rechargeable batteryProtocol Proprietary RF Protocol using multi-path multi-repeater mesh architectureRF Range 100 metres in free air depending on obstructionsNumber of devices Up to 12 RF devicesIndicator LEDs 3 colour LED blue green and redData requirements Monitoring via Ei1000G gateway download via EiUSB1Operating temperature -10C to 40CHumidity range 15 to 95 relative humidityMaterial PlasticHeight 150mmWidth 145mmDepth 55mm

GBP 350.89
1

Aico RadioLINK Switched Input Module Ei408

Aico RadioLINK Switched Input Module Ei408

Aico RadioLINK Switched Input Module Ei408The Ei408 Switched Input Modulehas been designed totriggers the alarmsin a system if anexternal device isactivated such as a sprinkler system.The Ei408 is powered by a tamper proof sealed in lithium cell giving a completely wire free installation with a 10 year life.The unituses RadioLINK to wirelessly interconnect with the rest of the alarm system so once in place you will need toHouse Codethe switch into the alarm system.Operation of the Ei408On receiving a volt-free switched hardwired signal the unit will transmit a RadioLINK alarm signalThe indicator will flash green every 40 seconds to indicate that the lithium cell power supply is healthyIf the Lithium cells are depleted the indicator will flash amber every 10 seconds and the unit needs replacingTechnical SpecificationFor use with 140RC when using anEi168Rc RadioLINK base160ewhen using andEi100MRF RadioLINK module Ei3000 series when using anEI3000MRF SmartLINK moduleor any RadioLINK enabled CO alarms.Eliminates the need for any cabling between the Ei408 and the smoke heat and CO alarms used in the system.Features built-in tamper proof FDK Lithium cells capable of lasting at least 10 years under normal usage. Operating the yellow onoff switch sited on the back of the unit activates the cells. The LED on the front cover will flash red amber green on power up after this it will flash green every 40 seconds to indicate a healthy power supply.Low battery warning signal LED indicator flashes amber every 10 seconds to indicate depleted battery. If this occurs the complete unit should be replaced.The unit has built-in wiring terminals for connection to an external set of volt-free switched contacts. On the contacts closing the Ei408 will send out a RadioLINK alarm signal to trigger all other RadioLINK devices within the system.Radio frequency 868 MHz Band in accordance with RTTE Directive 19995EC this band has been designated for use with security products and only allows a 1 duty cycle so continuous transmission and interference form external sources is extremely remote and would be illegal.Range The type of building will be the major limiting factor e.g. the number and type of wallsceilings that the radio signal has to pass through. As a guide 30m should be the maximum distance between any of the RadioLINK units in the system.Up to 20 RadioLINK units can be used in one system. Range will be the limiting factor.Units are in Factory Code mode when received they will all communicate with each other. They must be House Coded to eliminate the risk of adjacent properties communicating with each other. After House Coding they will only communicate with other RadioLINK units coded at the same time.House Code Operate the House Code switch on all RadioLINK units in the system see the instructions supplied with other RadioLINK units being used. The green LED on the cover of the Ei428 will change to red and flash slowly this indicates that it will receive the unique serial numbers being sent by all other RadioLINK units in House Code. The number of flashes of the LED indicates the number of units in the system The Ei428 will return to normal standby mode automatically after 15 minutes. Pressing the House Code switch again will return it to normal standby immediately.The Ei408 is conformant to EN300220-1 2000-09 RF Performance and EN301489-3 2002-08 EMC.Designed for surface mounting.Ambient Temperature Range 4C to 40C. Humidity Range 0 to 90 relative humidity.Dimensions 90mm x 90mm x 43mm. Weight inclusive of packaging 240g.5 year guarantee.Manufactured in Ireland.Key FeaturesStand alone unit designed for use with RadioLINK bases AccessoriesAccepts a hardwired input e.g. from sprinkler systemVisual RF transmission and power indicatorPowered by built-in Lithium cellsUnique House CodingLow battery power warningRF performance to EN 300220-15 Year Guarantee

GBP 61.67
1

Aico RadioLINK Relay Module with 5A Relay amp Rechargeable Battery Back-up Ei428

Aico RadioLINK Relay Module with 5A Relay amp Rechargeable Battery Back-up Ei428

Aico RadioLINK Relay Module with 5A Relay Rechargeable Battery Back-up Ei428The Ei428 is a mains powered relay module that triggers external devices such as a strobe light or telecare deviceif the alarmsin the propertyactivate.For use with 140RC when using anEi168Rc RadioLINK base160ewhen using andEi100MRF RadioLINK module Ei3000 series when using anEI3000MRF SmartLINK moduleor any RadioLINK enabled CO alarms.The module has additional trunking knock outsto make as easy to install as possibleand is designed to fit underneath the space of easi-fit or RadioLINK base. However a cover Ei128COV is available if needed and containsa set of volt free contacts as standard.The replay module can beconfigured to give a 230V output or a 24V output using an external 24V supplyOperation of Ei428 RadioLINK Relay ModuleOn receiving a RadioLINK signal from one of the alarms in the system the relay contacts will be operated causing a signal to be sent to the system to which it is connectedThe indicator on the cover will show a constant green light when the mains power is connected.Technical SpecificationA relay module with cover to allow flexibility in siting.For use with 140RC when using anEi168Rc RadioLINK base160ewhen using andEi100MRF RadioLINK module Ei3000 series when using anEI3000MRF SmartLINK moduleor any RadioLINK enabled CO alarms.Eliminates the need for any cabling between the Ei428 and the smoke heat and CO alarms used in the system.Requires 230V AC Mains Power Supply Green LED to indicate mains power is present.Features built-in tamper proof Rechargeable Vanadium Pentoxide lithium standby cells capable of lasting at least 10 years and powering the module initially for at least 2 months in the event of mains power failure. The cell manufacturer endorses a minimum 10-year life expectation for the rechargeable cells which are activated by operating the battery switch inside the module.The product is CE marked to indicate conformance to BS EN 600651998 Electrical Safety EN300220-1 V1.3.1 2000-09 RF Performance EN301489 V1.4.1 2002 08 EMC and has been 3rd party tested for electrical safety in accordance with Annex K of BS 5446 Pt.12000.Radio frequency 868 MHz Band in accordance with RTTE Directive 19995EC this band has been designated for use with security products and only allows a 1 duty cycle so continuous transmission and interference form external sources is extremely remote and would be illegal.Range The type of building will be the major limiting factor e.g. the number and type of wallsceilings that the radio signal has to pass through. As a guide 30m should be the maximum distance between any of the RadioLINK units in the system.Up to 20 RadioLINK units can be used in one system. Range will be the limiting factor.Low back-up warning signal LED indicator flashes RED every 10 seconds to indicate that the lithium cells are depleted.Units are in Factory Code mode when received they will all communicate with each other. They must be House Coded to eliminate the risk of adjacent properties communicating with each other. After House Coding they will only communicate with other RadioLINK units coded at the same time.House Code Operate the House Code switch on all RadioLINK units in the system see the instructions supplied with other RadioLINK units being used. The green LED on the cover of the Ei428 will change to red and flash slowly this indicates that it will receive the unique serial numbers being sent by all other RadioLINK units in House Code. The number of flashes of the LED indicates the number of units in the system The Ei428 will return to normal standby mode automatically after 15 minutes. Pressing the House Code switch again will return it to normal standby immediately.Volt free contacts Normally Open or Normally Closed rated up to 240V AC 5 Amps making it suitable for use with a wide range of AC or DC voltages. The relay contacts operate on mains power or on back-up cells in the event of mains failure.A RadioLINK Manual Call Point Ei407 and remote control switches Ei450 Ei412 and Ei411H are also available for use in the system. See separate specification sheets for further information.Features 1 x 25mm trunking for for surface wiring and centre knockout for recess wiring.Ambient Temperature Range 4C to 40C. Humidity Range 0 to 90 relative humidity.Dimensions 140mm diameter x 27mm depth weight inclusive of packaging 220g.5 year guarantee.Manufactured in Ireland.Key FeaturesDesigned for use with all RadioLINK Professional alarms and accessoriesRechargeable Lithium battery back-upVolt-free contacts as supplied for multiple usesCan be configured to switch a 230V or 24V outputTrunking knock-outs for easy and neat wiringContinuous or Pulse operation5 Year Guarantee

GBP 98.36
1