39 results (0,17105 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Aico Plug-in RadioLINK module Ei200MRF

Aico EI1000G SmartLINK Gateway - Mains with Lithium Back-up

Aico EI1000G SmartLINK Gateway - Mains with Lithium Back-up

Aico EI1000G SmartLINK Gateway - Mains with Lithium Back-upThe SmartLINK Gateway is designed for use with the Aico RF devices. It provides a mechanism to transfer information from the RF network to a portal over the GSM network.It is mains powered with a rechargeable battery backup that can provide up to 72hrs of power supply in case of mains failure.Connected devices events are processed by the Gateway as they occur and cover events such asFire AlarmCO level detected High Medium LowButton TestMains Absent FaultHead OKHead RemovedEnd of lifeTo ensure the safety of the data it is encrypted in both directions during transmission using AES128 encryption.In addition for ease of installation the SmartLINK App available on Android iOS provides a step-by-step guide for the installation of the Gateway and the Aico RF devices.All data sent is accessible from a web portal where alerts can be set up to be delivered by email or SMS. Reports can also be run from the web portal to facilitate the management of the Alarms fitted.The data on the portal is securely stored and is only available to the associated client.Key FeaturesEnables remote management of RF AlarmsReceives RF specific data from RF devicesTransmits data over GSM networkNot GSM provider dependentBidirectional data encryptionUnique House Coding featureEasy setup and configurationCompatible with SmartLINK RadioLINKProvides specific data from radio frequency devicesHeart beat every 12 hours which gets sent to the portalTo connect to your smart device and portal you simply scan QR codes on alarm and moduleEasy installation and configurationTransmits data over GSM networkUnique house coding featureData upload 2G GSM network roaming sim card supplied no subscription necessaryFrequency 868MHz band 1 duty cyclePower usage 40mAVoltage 230VBattery back-up Rechargeable batteryProtocol Proprietary RF Protocol using multi-path multi-repeater mesh architectureRF Range 100 metres in free air depending on obstructionsNumber of devices Up to 12 RF devicesIndicator LEDs 3 colour LED blue green and redData requirements Monitoring via Ei1000G gateway download via EiUSB1Operating temperature -10C to 40CHumidity range 15 to 95 relative humidityMaterial PlasticHeight 150mmWidth 145mmDepth 55mm

GBP 350.89
1

Aico RadioLINK Alarm for Deaf 230V with Strobe Vibrating Pad Ei170RF

Aico RadioLINK Alarm for Deaf 230V with Strobe Vibrating Pad Ei170RF

Aico RadioLINK Alarm for Deaf 230V with Strobe Vibrating Pad Ei170RFTheEi170RF is a mains powered with rechargeable battery back up alarm kitfor the deaf and hard of hearing. Thekit contains aXenon strobe lightthat provide and plug in vibrating pillow pad that will activate when the interconnected alarms are triggered to alert theuser tothe danger.TheEi170RF kit is compatible with the3000Multi-Sensor Fire Alarm Ei2110e160e Seriesalarms and 140RC Series smoke and heat alarms along with any interconnected Carbon Monoxide alarms. This kit links into the alarm system usingRadioLINK wireless interconnection technology making it easier to add into a system and causing less disruption to the occupants on installation.An integral Test button is also present on the front of the unit allowing an easy means of testing the strobe vibration pad and the RadioLINK enabled alarms in the system.As with other RadioLINK products the Ei170 Alarm Kit for the Deaf and Hard of Hearing will need to belinked into the alarm system or House Coded. View ourstep by step guide to House Coding here.Technical Specification A strobe and vibrating pillow pad kit designed to give warning of fire to deaf and hard of hearing occupants. For use with30002110e160eand 140RC Series smoke and heat alarms when used with aRadioLINK baseRadioLINK moduleor theSmartLINKmoduleRadioLINK Carbon MonoxideCO alarms. It can also be used with all other RadioLINK devicesancillaries including the 600 Series RadioLINK smoke and heat alarms.Eliminates the need for any cabling between the Ei170 RF and the smoke heat andor CO alarms used in the system.Requires 230V AC 50Hz mains power supply.The unit has a built-in high-intensity Xenon strobe flash rate 0.8Hz with a wide light output angle.Built-in long life sealed lead acid rechargeable battery to provide back-up power in the event of mains failure. Standby capacity 7 days followed by 15 minutes alarm lifespan 5 years in normal use. The battery is connected by plugging it into the socket in the bottom of the battery box.Comprehensive indicating lights on front of the unitPower Constant green to indicate mains is present flashes amber every 4 seconds with mains absent.Alarm red Flashes every second when the unit has been triggered.Fault amber Flashes every 4 seconds if a fault is detected with panelvibration pad. Flashes every 4 seconds if rechargeable back-up battery is depleted or faulty.RF status blue Illuminates when RF signal is being sent flashes in House Code mode to indicate the number of units learned. Flashes every 40 seconds if RadioLINK smoke alarms have a low battery.Mains transformer is mounted in separate and hard-wired to the strobe unit with 4m of low voltage cable. Supplied with 2m of mains cable and pre-wired 13 amp plug with a 3 amp fuse.Integrated Test button on the front of the unit. Pressing this checks strobe and control circuitry and also send out a RadioLINK alarm signal to other units in the system.The vibrating pillow pad is suitable for mounting under mattresses or pillows and produces strong pulsed vibrations suitable for waking sleepers. Supplied with locking plug and 5m of pre-wired cable.Connecting sockets on rear of unit as followsVibration Pad socket Locking socket JST type VHR-2N. Is pulsed when unit is in alarm.Auxiliary sockets Two auxiliary sockets are available on the rear of the unit to allow connection of additional strobes etc. Locking sockets JST type VHR-2N. Each provides 12V200mA when unit is in alarm. Can be used for any of the following Auxiliary strobe Ei178 auxiliary vibration pad Ei174 or for triggering a radio pager.A clock input socket is also available. This is for use will alarm clocks that have a 3.5mm mono jack output and saves the need for multiple vibration pads. An input of 5-12V AC or DC mains isolated will turn on the vibration pad constant vibration pattern but will not activate the strobe or auxiliary sockets.Radio frequency 868MHz band in accordance with RTTE Directive 19995EC this band has been designed for use with security products and only allows a 1 duty cycle so continuous transmission and interference from external sources is extremely remote and would be illegal. Complies with EN300220-2V2.1.1.RF Range The type of building will be the major limiting factor e.g. the number and type of wallsceilings that the radio signal has to pass through. As a guide 30m should be the maximum distance between any of the RadioLINK units in the system.Up to 12 RadioLINK units can be used in one system. For larger systems contact our Technical Department for guidance.

GBP 279.71
1

Aico EI650iRF RadioLINK Optical Smoke Alarm - 10 Year Lithium Battery Powered - With AudioLink

Aico EI650iRF RadioLINK Optical Smoke Alarm - 10 Year Lithium Battery Powered - With AudioLink

Aico EI650iRF RadioLINK Optical Smoke Alarm - 10 Year Lithium Battery Powered - With AudioLink The Ei650iRF is a battery-powered Optical Smoke Alarm. It is able to wirelessly interconnect with any other RadioLINK RadioLINK and SmartLINK products. Contains an Optical Smoke ChamberThe Ei650iRF RadioLINK Optical Smoke Alarm is best for detecting slow smouldering fires commonly produced by electrical fires or sofas and is less likely to react to cooking smells if fitted in the hallway next to the kitchen.Battery and LifespanThis battery powered alarm contains sealed in tamper-proof lithium battery that will last for the full 10-year life of the alarm. The alarm is not powered until it is twisted on the mounting base thus avoiding battery power consumption during storage and prior to installation.Built-in RadioLINK Wireless Interconnection TechnologyRadioLINK wireless interconnection technology is built-in to this alarm. RadioLINK uses Radio Frequency signals to link alarms together with added functionality. All RadioLINK alarms and devices should be House Coded together upon install.Key FeaturesOptical sensor with dust compensation technologyBuilt-in AudioLINKUses built-in RadioLINK technology to interconnect and for data extractionConnects wirelessly with all other Aico wireless interconnection productsBattery powered with a sealed-in lithium batteryEasy to fit twist on base and multi-fixings with an anti-tamper locking option10-year lifeGrade F1 and compliant with Scottish legislationKitemarked to BS EN 146042005

GBP 94.61
1

Aico EI650i Optical Smoke Alarm - 10 Year Lithium Battery Powered

Aico RadioLINK Panel Interface Ei413

Aico RadioLINK Panel Interface Ei413

Aico RadioLINK Panel Interface Ei413The Ei413 is a RadioLINK Panel Interface Module that provides an interface between RadioLINK alarms and accessories and fire alarmsecurity alarm panels. The module will decode aFire Carbon Monoxide and fault signals from RadioLINK devices and activate the Panel accordingly and will also work the other way activating the domestic alarms if it receives a signal from the Panel.The module is powered either directly from the Panel Systemor from an external source.Operation of the Ei413 RadioLINK Panel Interference ModuleOn receiving a Volt-free switched hardwired signal from the panel the module will transmit a RadioLINK alarm signal to activate the alarms in the systemIf a fire alarm has activated the module will recognise the signal as a fire and switch the relevant contacts to activate the panelIf a Carbon Monoxidealarm has activated the module will recognise the signal as a Carbon Monoxideleak and switch the relevant contacts to activate the panelTechnical SpecificationEliminate the need for any cabling between the Ei413 and the smokeheatCO alarms used in the system.The Ei413 is conformant to EN300220-1 RF Performance in accordance with EN300220-2 and EN301489-1 EMC referencing EN301489-3.The unit is powered from the alarm panel and requires 11 to 30VDC. Unit current rating 15mA Standby 60mA Alarm Max.The unit has three sets Normally Open Normally Closed and Common of built-in wiring contacts for connection to the panel rated at 30V 1 Amp. On the contacts closing the unit will dependent on which set of contacts are connected indicate a fire CO leak or fault to the panel. The unit also has a Normally Open volt-free set of contacts to link from the panel to it so if the panel is activated the unit will transmit a RadioLINK signal to the alarms in the system to activate them they will sound.Radio frequency 868MHz band in accordance with RTTE Directive 19995EC this band has been designed for use with security products and only allows a 1 duty cycle so continuous transmission and interference from external sources is extremely remote and would be illegal.Up to 12 RadioLINK units can be used in one system. Range may be a limiting factor.RF Range The type of building will be the major limiting factor e.g. the number and type of wallsceilings that the radio signal has to pass through. As a guide 30m should be the maximum distance between any of the RadioLINK units in the system.Units are in factory code when received they will communicate with each other. They must be House Coded to eliminate the risk of adjacent properties communicating with each other. After House Coding they will only communicate with other RadioLINK units coded at the same time.House Code Operate the House Code Switch on all RadioLINK units in the system see the instructions supplied with the other RadioLINK units being used. The LED indicator on the front cover of the Ei413 will flash blue slowly this indicates that it is transmitting its unique serial number to all other RadioLINK units in House Code. After a short time the unit will flash to indicate the number of units in the system 2 flashes 2 units 3 flashes 3 units etc.. The Ei413 will return to normal standby mode automatically after 15 minutes. Pressing the House Code Switch again will return it to normal standby immediately.Designed for surface mounting or can be fitted into certain alarm panels provided the casing is not a metallic construction which may restrict RF signals.Dimensions 88mm x 88mm x 28mm.Weight 150g.Ambient Temperature Range 0C to 40C.5 year guarantee.Manufactured in Ireland.

GBP 76.93
1

Aico EASI-FITBASE Easi-Fit Base For Use With 140RC and 3000 Series Alarms

Aico RadioLINK Switched Input Module Ei408

Aico RadioLINK Switched Input Module Ei408

Aico RadioLINK Switched Input Module Ei408The Ei408 Switched Input Modulehas been designed totriggers the alarmsin a system if anexternal device isactivated such as a sprinkler system.The Ei408 is powered by a tamper proof sealed in lithium cell giving a completely wire free installation with a 10 year life.The unituses RadioLINK to wirelessly interconnect with the rest of the alarm system so once in place you will need toHouse Codethe switch into the alarm system.Operation of the Ei408On receiving a volt-free switched hardwired signal the unit will transmit a RadioLINK alarm signalThe indicator will flash green every 40 seconds to indicate that the lithium cell power supply is healthyIf the Lithium cells are depleted the indicator will flash amber every 10 seconds and the unit needs replacingTechnical SpecificationFor use with 140RC when using anEi168Rc RadioLINK base160ewhen using andEi100MRF RadioLINK module Ei3000 series when using anEI3000MRF SmartLINK moduleor any RadioLINK enabled CO alarms.Eliminates the need for any cabling between the Ei408 and the smoke heat and CO alarms used in the system.Features built-in tamper proof FDK Lithium cells capable of lasting at least 10 years under normal usage. Operating the yellow onoff switch sited on the back of the unit activates the cells. The LED on the front cover will flash red amber green on power up after this it will flash green every 40 seconds to indicate a healthy power supply.Low battery warning signal LED indicator flashes amber every 10 seconds to indicate depleted battery. If this occurs the complete unit should be replaced.The unit has built-in wiring terminals for connection to an external set of volt-free switched contacts. On the contacts closing the Ei408 will send out a RadioLINK alarm signal to trigger all other RadioLINK devices within the system.Radio frequency 868 MHz Band in accordance with RTTE Directive 19995EC this band has been designated for use with security products and only allows a 1 duty cycle so continuous transmission and interference form external sources is extremely remote and would be illegal.Range The type of building will be the major limiting factor e.g. the number and type of wallsceilings that the radio signal has to pass through. As a guide 30m should be the maximum distance between any of the RadioLINK units in the system.Up to 20 RadioLINK units can be used in one system. Range will be the limiting factor.Units are in Factory Code mode when received they will all communicate with each other. They must be House Coded to eliminate the risk of adjacent properties communicating with each other. After House Coding they will only communicate with other RadioLINK units coded at the same time.House Code Operate the House Code switch on all RadioLINK units in the system see the instructions supplied with other RadioLINK units being used. The green LED on the cover of the Ei428 will change to red and flash slowly this indicates that it will receive the unique serial numbers being sent by all other RadioLINK units in House Code. The number of flashes of the LED indicates the number of units in the system The Ei428 will return to normal standby mode automatically after 15 minutes. Pressing the House Code switch again will return it to normal standby immediately.The Ei408 is conformant to EN300220-1 2000-09 RF Performance and EN301489-3 2002-08 EMC.Designed for surface mounting.Ambient Temperature Range 4C to 40C. Humidity Range 0 to 90 relative humidity.Dimensions 90mm x 90mm x 43mm. Weight inclusive of packaging 240g.5 year guarantee.Manufactured in Ireland.Key FeaturesStand alone unit designed for use with RadioLINK bases AccessoriesAccepts a hardwired input e.g. from sprinkler systemVisual RF transmission and power indicatorPowered by built-in Lithium cellsUnique House CodingLow battery power warningRF performance to EN 300220-15 Year Guarantee

GBP 61.67
1

Aico EI3018EF Eco-Fit Pack - CO Alarm - 230V With 10 Year Rechargeable Lithium Back-up

Aico RadioLINK Relay Module with 5A Relay amp Rechargeable Battery Back-up Ei428

Aico RadioLINK Relay Module with 5A Relay amp Rechargeable Battery Back-up Ei428

Aico RadioLINK Relay Module with 5A Relay Rechargeable Battery Back-up Ei428The Ei428 is a mains powered relay module that triggers external devices such as a strobe light or telecare deviceif the alarmsin the propertyactivate.For use with 140RC when using anEi168Rc RadioLINK base160ewhen using andEi100MRF RadioLINK module Ei3000 series when using anEI3000MRF SmartLINK moduleor any RadioLINK enabled CO alarms.The module has additional trunking knock outsto make as easy to install as possibleand is designed to fit underneath the space of easi-fit or RadioLINK base. However a cover Ei128COV is available if needed and containsa set of volt free contacts as standard.The replay module can beconfigured to give a 230V output or a 24V output using an external 24V supplyOperation of Ei428 RadioLINK Relay ModuleOn receiving a RadioLINK signal from one of the alarms in the system the relay contacts will be operated causing a signal to be sent to the system to which it is connectedThe indicator on the cover will show a constant green light when the mains power is connected.Technical SpecificationA relay module with cover to allow flexibility in siting.For use with 140RC when using anEi168Rc RadioLINK base160ewhen using andEi100MRF RadioLINK module Ei3000 series when using anEI3000MRF SmartLINK moduleor any RadioLINK enabled CO alarms.Eliminates the need for any cabling between the Ei428 and the smoke heat and CO alarms used in the system.Requires 230V AC Mains Power Supply Green LED to indicate mains power is present.Features built-in tamper proof Rechargeable Vanadium Pentoxide lithium standby cells capable of lasting at least 10 years and powering the module initially for at least 2 months in the event of mains power failure. The cell manufacturer endorses a minimum 10-year life expectation for the rechargeable cells which are activated by operating the battery switch inside the module.The product is CE marked to indicate conformance to BS EN 600651998 Electrical Safety EN300220-1 V1.3.1 2000-09 RF Performance EN301489 V1.4.1 2002 08 EMC and has been 3rd party tested for electrical safety in accordance with Annex K of BS 5446 Pt.12000.Radio frequency 868 MHz Band in accordance with RTTE Directive 19995EC this band has been designated for use with security products and only allows a 1 duty cycle so continuous transmission and interference form external sources is extremely remote and would be illegal.Range The type of building will be the major limiting factor e.g. the number and type of wallsceilings that the radio signal has to pass through. As a guide 30m should be the maximum distance between any of the RadioLINK units in the system.Up to 20 RadioLINK units can be used in one system. Range will be the limiting factor.Low back-up warning signal LED indicator flashes RED every 10 seconds to indicate that the lithium cells are depleted.Units are in Factory Code mode when received they will all communicate with each other. They must be House Coded to eliminate the risk of adjacent properties communicating with each other. After House Coding they will only communicate with other RadioLINK units coded at the same time.House Code Operate the House Code switch on all RadioLINK units in the system see the instructions supplied with other RadioLINK units being used. The green LED on the cover of the Ei428 will change to red and flash slowly this indicates that it will receive the unique serial numbers being sent by all other RadioLINK units in House Code. The number of flashes of the LED indicates the number of units in the system The Ei428 will return to normal standby mode automatically after 15 minutes. Pressing the House Code switch again will return it to normal standby immediately.Volt free contacts Normally Open or Normally Closed rated up to 240V AC 5 Amps making it suitable for use with a wide range of AC or DC voltages. The relay contacts operate on mains power or on back-up cells in the event of mains failure.A RadioLINK Manual Call Point Ei407 and remote control switches Ei450 Ei412 and Ei411H are also available for use in the system. See separate specification sheets for further information.Features 1 x 25mm trunking for for surface wiring and centre knockout for recess wiring.Ambient Temperature Range 4C to 40C. Humidity Range 0 to 90 relative humidity.Dimensions 140mm diameter x 27mm depth weight inclusive of packaging 220g.5 year guarantee.Manufactured in Ireland.Key FeaturesDesigned for use with all RadioLINK Professional alarms and accessoriesRechargeable Lithium battery back-upVolt-free contacts as supplied for multiple usesCan be configured to switch a 230V or 24V outputTrunking knock-outs for easy and neat wiringContinuous or Pulse operation5 Year Guarantee

GBP 98.36
1

Aico EI1020 Temperature and Humidity Environmental Sensor

Aico EI1025 Temperature Humidity and CO2 Environmental Sensor

Aico RadioLINK Manual Call Point Ei407

Aico RadioLINK Manual Call Point Ei407

Aico RadioLINK Manual Call Point Ei407This call point is powered by a tamper proof sealed inlithium cell giving a completely wire free installation with a 10-year life.The front plate is made from a non-breaking plastic that means if the callpoint is used you can simply reset the plate rather than having to replace it.The Ei407 connects wirelessly using RadioLINKinterconnection technology so once in place you will need to House Code theswitch into the alarm system.Operation The indicator will flash green every 40 seconds to indicatethat the battery is healthyThe indicator will flash amber every 9 seconds to indicatethat the batteries are depletedKey FeaturesAllows for remote triggering of an alarm systemNon-breaking re-settable front platesContains 10-year lithium cell for completely wire freeinstallationConnects wirelessly with all other Aico wirelessinterconnection productsTechnical SpecificationFor use with 140RC when using anEi168Rc RadioLINK base160ewhen using andEi100MRF RadioLINK module Ei3000 series when using anEI3000MRF SmartLINK moduleor any RadioLINK enabled CO alarmsEliminates the need for any cabling between the Ei407 and the smoke andor heat alarms within the systemFeatures built-in tamper proof FDK Lithium cells capable of lasting at least 10 years under normal usage. operating the yellow onoff switch sited on the back of the unit activates the cells. The LED on the front cover will flash red amber green on power up after this it will flash green every 40 seconds to indicate a healthy power supply. If the LED flashes amber every 40 seconds this indicates a depleted battery and the complete unit must be replacedThe product is CE marked to indicate conformance to BS EN 600651998 Electrical Safety EN300220-1 V1.3.1 2000-09 RF Performance EN301489 V1.4.1 2002-08 EMC and has been 3rd party tested for electrical safety in accordance with Annex K of BS 5446 Pt 12000Radio frequency 868MHz in accordance with RTTE Directive 19995EC this band has been designated for use with security products and only allows a 1 duty cycle so continuous transmission and interference from external sources is extremely remote and would be illegalUp to 12 RadioLINK units can be used in one system. For larger systems contact our Technical Department for guidance also see section 7Range the type of building will be the major limiting factor e.g. the number and type of wallsceilings that the radio signal has to pass throughLow battery warning signal LED indicator flashes amber every 40 seconds to indicate depleted battery if this occurs the complete unit should be replacedSimply key to rest the unit no broken glassReplacement key MCRSK availableAmbient temperature range 4c to 40c. Humidity range 0 to 90 relative humidityExternal alarm RadioLINK signal operates sounder on any smoke alarm with a RadioLINK in the systemUnits are in factory code when received they will all communicate with each other. They must be House Coded to eliminate the risk of adjacent properties communicating with each other. After house coding they will only communicate with other units coded at the same timeHouse Code Operate the red House Code switch on the back of the unit. At the same time put all other RadioLINK units in the system into House Code see relevant instruction leaflets. The red LED on the front cover will flash rapidly to indicate that it is in House Code. Each RF base will learn the serial numbers of all units in the system any other RadioLINK units. The number of flashes of the amber light on the RF units indicates the number of alarms in the system. All units will return to normal standby mode automatically after 15 minutes. Pressing the House Code switch again will return them to normal standby immediatelyThe Ei407 can be incorporated into a system consisting of any additional RadioLINK componentsDimensions 85mm x 85mm x 57mm deep including mounting boxWeight 240g including packaging5 year guaranteeManufactured in Ireland

GBP 58.33
1

Aico Ei630iRF RadioLINK Heat Alarm - 10 Year Lithium Battery Powered with AudioLink

Aico Ei630i Heat Alarm - 10 Year Lithium Battery Powered

Aico Ei171RF RadioLINK Flashing Strobe with Rechargeable Back-up

Aico Ei171RF RadioLINK Flashing Strobe with Rechargeable Back-up

AicoEi171RFRadioLINK Flashing Strobe with Rechargeable Back-upThe Ei171RF is a RadioLINK alarm accessory that is designed to give warning to the deaf and hard of hearing if their alarm system has activated. It consists of a mains powered strobe light with a rechargeable battery back-up. This strobe has been designed specifically for daytime rooms as a visual indicator with a specially designed lens for wide-angle light output.For protection in a bedroom we recommend the Ei170RF alarm kit as this combines a strobe light and a vibrating pillow pad for extra warning.This Strobe Light is compatible with the 3000 Multi-Sensor Fire Alarm Ei2110e 160e Series alarms and 140RC Series smoke and heat alarms along with any interconnected Carbon Monoxide alarms. This kit links into the alarm system using RadioLINK wireless interconnection technology making it easier to add into a system and causing less disruption to the occupants on installation.As with other RadioLINK products the Ei17iRF Strobe for the Deaf and Hard of Hearing will need to be linked into the alarm system or House Coded.Key FeaturesFor use with 3000 2110e 160e and 140RC Series smoke and heat alarms when used with a RadioLINK base RadioLINK module or a SmartLINK module and RadioLINK Carbon Monoxide CO alarms it can also be used with all other RadioLINK devicesancillariesEliminates the need for any cabling between the Ei170 RF and the smoke heat andor CO alarms used in the systemRequires 230V AC 50Hz mains power supplyBuilt-in high-intensity Xenon strobe flash rate 0.8Hz with a wide light output angleBuilt-in long life sealed lead acid rechargeable batteryMains transformer is mounted in separate and hard-wired to the strobe unit with 4m of low voltage cable. Supplied with 2m of mains cable and pre-wired 13 amp plug with a 3 amp fuseIntegrated Test button on the front of the unit. Pressing this checks strobe and control circuitry and also send out a RadioLINK alarm signal to other units in the systemUp to 12 RadioLINK units can be used in one system. For larger systems contact our Technical Department for guidanceAn optional additional strobe Ei178 is available for providing warning in additional rooms The Ei178 is supplied with 10m of pre-wired cable and plug for connection to one of the auxiliary socketsThe product is CE marked to indicate conformance to directives EMC 89336EEC tested to EN50130-4 Low Voltage 7323EEC tested to EN60065 RTTE 19995EC tested to EN300220-2V2.1.1Designed for wall or surface mountingDimensions Control box 195mm x 125mm x 75mm. Mains adapter 60mm x 50mm x 90mmWeight Control box 770g. Mains adapter 600gAmbient Temperature Range 4C to 40C. Humidity Range 0 to 90 relative humidity5-year guarantee

GBP 245.27
1

Aico EI3028 Series Heat amp Carbon Monoxide Multi-Sensor Fire Alarm

Aico EI3028 Series Heat amp Carbon Monoxide Multi-Sensor Fire Alarm

Aico EI3028 Series Heat Carbon Monoxide Multi-Sensor Fire AlarmThe Ei3028 is a Multi-Sensor Heat and Carbon Monoxide CO Alarm. It contains our proven fast acting Class A1 Thermistor sensor to detect fire as well as our proven electrochemical CO sensor to detect the presence of toxic levels of CO. This provides protection from both Fire and CO in one alarm. The Ei3028 runs on 230V AC mains power. In the event of mains failure the 10 Year built in tamper-proof rechargeable lithium cells will provide back-up supply and continuous operation.The Ei3028 contains AudioLINK technology which allows you to extract real time data from the alarm directly to a smartphone or tablet via the AudioLINK App. During an alarm Fire or CO indicators will flash on the Alarm to indicate what has been detected. There will also be a different alarm sound depending on what has triggered the alarm. The Ei3028 is fitted with a large Test Silence button to facilitate frequent testing of the alarm and system. The silence function allows the alarm system to be silenced in the case of a false nuisance alarms and low battery fault beeps.The Ei3028 self-tests its sensors battery and internal circuitry every 48 seconds. Any fault condition found will be indicated by a combination of yellow LED flashes andor audible beeps. SmartLINK compatible - plug in an Ei3000MRF module for wireless interconnection data extraction and real-time notifications of alarm activations and events via the SmartLINK Gateway and Portal.Key FeaturesSensor Type Thermistor Electrochemical CO10 year lifeEasi-fit baseHeat or CO indicator on alarm headAudioLINK data extraction technologyCompatible with other Aico mains powered unitsAdd and Ei3000MRF for wireless interconnection and data extractionMains powered with 10 year rechargeable lithium cell back-upContains both a Heat and Electrochemical CO sensor Heat and CO coverage in one alarmSupply Voltage 230V AC 50HzPower Consumption 0.25W standbyBattery Back-up Rechargeable lithium cellsSound Level 85dBA at 3mButton Test Checks sensors electronics LED displays and sounderSilence Function Silences alarm for 10 minutes if alarm is triggered by heat or once for 4 minutes in case of CO event.Silence Function Silences fault beeps for 12 hoursAudioLINK EnabledSmartLINK Compatible via the Ei3000MRF ModuleIndicator LEDS Green power. Red pre-alarm CO only alarm silence mode memory or battery event. Yellow fault eventMemory Records last alarm eventFixing easi-fit base suppliedOperating Temperature -10C to 35CHumidity Range 15 to 95 relative humidityPlastic Material UL 94 V0 flame retardantDimensions Product 150mm x 66mmDimensions Boxed 180mm x 155mm x 72mmWeight 318g product only 384g boxedGuarantee 5 years

GBP 117.24
1

Aico EI660iRF Multi-Sensor RF Fire Alarm With 10 Year Lithium Cells with AudioLINK amp RadioLINK

Aico Ei3018 230v 3000 Series Carbon Monoxide Alarm

Aico Ei3018 230v 3000 Series Carbon Monoxide Alarm

Aico Ei3018 230v 3000 Series Carbon Monoxide AlarmThe Ei3018 is a Carbon Monoxide CO Alarm powered by 230V AC mains power and has built in tamper proof rechargeable lithium cells that act as a battery back up in the event of mains failure. These rechargeable lithium cells are designed to last the life of the CO alarm. The Ei3018 has a high performance proven electrochemical sensor 10 year life to sense CO presence. The sensor is individually calibrated and tested in CO gas to ensure accuracy. In alarm the flash rate of the red LED indicates the level of CO detected.The Ei3018 contains AudioLINK technology which allows you to extract real time data from the alarm directly to a smartphone or tablet via the AudioLINK App. The Ei3018 can operate as a standalone alarm or can be interconnected either by hard-wire or wirelessly using the EI3000MRF module enabling it to communicate with compatible alarms and accessories. Up to 12 devices can be interconnected.The memory feature allows an alarm that has previously activated to be easily identified through the red flashing LED. The alarm is fitted with a large Test Silence button to facilitate frequent testing of the alarm and system. The silence function allows the alarm system to be silenced in the case of a false nuisance alarms and low battery fault beeps. SmartLINK compatible - plug in an Ei3000MRF module for wireless interconnection data extraction and real-time notifications of alarm activations and events via the SmartLINK Gateway and Portal.Key FeaturesSensor Types Electrochemical cell10 year lifeEasi-fit baseAudioLINK data extraction technologyCompatible with other Aico mains powered devicesAdd an Ei3000MRF module for wireless interconnection and data extractionMains powered with 10 year rechargeable lithium cell back-upContains our proven Electrochemical CO sensorSupply Voltage 230V AC 50HzPower Consumption 0.25W standbyBattery Back-up Rechargeable lithium cellsSound Level 85dBA at 3mButton Test Checks sensors electronics and sounderSilence Function Silences alarm for 10 minutesSilence Function Silences fault beeps for 12 hoursAudioLINK EnabledSmartLINK Compatible via the Ei3000MRF ModuleIndicator LEDS Green power. Red pre alarm alarm silence mode memory. Yellow fault eventMemory Records last alarm eventOperating Temperature -10C to 35CHumidity Range 15 to 95 relative humidityPlastic Material UL 94 V0 flame retardantDimensions Product 150mm x 55mmDimensions Boxed 180mm x 155mm x 62mmWeight 310g product only 376g boxedGuarantee 5 years

GBP 89.60
1

Aico Ei3016 230v 3000 Series Optical Smoke Alarm

Aico Ei3016 230v 3000 Series Optical Smoke Alarm

Aico Ei3016 230v 3000 Series Optical Smoke AlarmThe Ei3016 Optical Smoke Alarm contains a high-performance optical smoke sensor which is best for detecting slow smoldering fires. In addition the smoke chamber design integrated insect screen and unique automatic dust compensation reduce the risk of false alarms. The Ei3016 runs on 230V AC mains power. In the event of mains failure the 10 Year built in tamper-proof rechargeable lithium cells will provide back-up supply and continuous operation.The Ei3016 contains AudioLINK technology which allows you to extract real time data from the alarm directly to a smartphone or tablet via the AudioLINK App. The Ei3016 self-checks its sensor battery and internal circuitry every 48 seconds. Any fault condition found will be indicated by a combination of yellow LED flashes andor audible beeps. The memory feature allows an alarm that has previously activated to be easily identified through the red flashing LED.The alarm is fitted with a large Test Silence button to facilitate frequent testing of the alarm and system. The silence function allows the alarm system to be silenced in the case of a false nuisance alarms and low battery fault beeps. SmartLINK compatible - plug in an Ei3000MRF module for wireless interconnection data extraction and real-time notifications of alarm activations and events via the SmartLINK Gateway and Portal.Key FeaturesContains a high-performance optical sensorMains powered with 10-year rechargeable Lithium cell back-upCompatible with interconnection and monitoring technologyAudioLINK TM Data extraction technologyDust compensation - unique self-monitoring mechanismEasi-Fit base10 Year lifeSensor Type OpticalSupply Voltage 230V AC 50HzPower Consumption 0.25W standbyBattery Back-up Rechargeable lithium cellsSound Level 85dBA at 3mButton Test Checks sensor electronics and sounderSilence Function Silences alarm for 10 minutesSilence Function Silences fault beeps for 12 hoursAudioLINK EnabledSmartLINK Compatible via the Ei3000MRF ModuleIndicator LEDS Green power. Red alarm silence mode memory. Yellow fault eventMemory Records last alarm eventFixing easi-fit base suppliedOperating Temperature -10C to 40CHumidity Range 15 to 95 relative humidityPlastic Material UL 94 V0 flame retardant

GBP 72.89
1

Aico Relay Module with 5A Relay amp Rechargeable Back-up Ei128RBU

Aico Relay Module with 5A Relay amp Rechargeable Back-up Ei128RBU

Aico Relay Module with 5A Relay Rechargeable Back-up Ei128RBUThe Ei128RBU is a Relay Module that runs on a 230V AC mains power and has built-in tamper-proof Lithium cells that act as a battery back up in the event of mains failure. These rechargeable lithium cells are designed to have a 10-year life and outlast the life of the module itself whilst providing up to 2 months of operation without mains power.The Module has a set of Volt free contacts Normally Open and Normally Closed as standard but can be configured to give a 230V output or a 24V output using an external 24V supply.Any combination of30002110e160e 140RC or 260RC Series alarms can be used up to 12 including the Relay.The Module is designed to fit underneath any smoke or heat alarm. However a cover is supplied if there is a need for siting the unit remotely.The Module has additional trunking knock outs for ease of wiring.The Module can give a Continuous or pulse output. The pulse output will switch back the Relay contacts to their original state after 5 seconds operation.Operation of the Ei128RBUOn receiving a signal form the alarm system the Relay contacts will be operated causing a signal to be sent to the device to which it is connected.The Ei128RBU can be used to switch into a range of devices ranging from warden call systems to panel systems.When modified for a 230V or 24V output they can operate a range of different devices.The Module can be switched to give a pulse output or continuous output for different applications.Technical Specification The Relay is designed to operate whilst the alarm system is sounding to signal devices such as panels warden call systems nurse call systems etc. When any of the interconnected alarms sound the signal will cause the relay contacts to switch.The Relay runs on 230V AC mains power and has built in tamper proof Lithium cells that act as a battery back up in the event of mains failure. These rechargeable Lithium cells are designed to have a 10 year life and outlast the life of the module itself whilst providing up to 2 months of operation without mains power. It operates on receipt of a signal form the interconnect line of a smoke heat or CO alarm.Volt-free contacts Normally Open or Normally Closed rated up to 240V AC 5 Amps making it suitable for use with a wide range of AC or DC voltages.Any combination of 3000 2110e 160e 140RC or 260RC smoke heat or CO alarms can be interconnected to a maximum of 12 units in total 1 x Ei128RBU counts as one unit.The Ei128RBU is designed for siting under one of the smokeheat alarms listed above. However a cover is supplied if installing remotely or with 260 series CO alarms.More than one Relay can be used in a set of interconnected alarms on the condition that no more than 12 units are used in the system 1 x Ei128RBU counts as one unit.Fitted with a 4 way connector block for ease of wiring.The Relay can be set for continuous or pulse operation through a manual switch when in pulse operation mode the Relay contacts will automatically switch back to their original state after 5 seconds.Features 3 x 25mm trunking knockouts for surface wiring and centre knockout for recess wiring.Dimensions of unit 135mm diameter x 20mm depth.Weight inclusive of packaging 265g.Manufactured in Ireland.Key FeaturesFor use with 2100 160RC and 140RC alarmsRechargeable lithium battery back-upVolt free contacts as supplied for multiple useCan be configured to switch a 230V or 24V deviceTrunking knock-outs for easy and neat wiringAdditional connectors for ease of wiringContinuous or pulse operationFits discreetly behind any smoke heat alarm5 Year Guarantee

GBP 71.82
1

Aico RadioLINK Alarm Controller Ei450

Aico RadioLINK Alarm Controller Ei450

Aico RadioLINK Alarm Controller Ei450The Ei450 is used to control all the alarms in a system from one place. We highly recommend fitting a control switch if you have smoke heatand carbon monoxide alarms on the same system as its essential that you can tell which alarm has sounded. From then you can identifywhich danger is present and the action you should take.The Ei450 contains LEDs which clearly display which danger has activated the alarm helping to you take the appropriate action as quickly as possible.Control Switchs increases the flexibility and user friendliness of the alarms by allowing the user to remotely Test Locate and Silencealarms in the systemTestThe alarm systemLocate The alarm that has been activatedSilence Any nuisance alarmsThe Ei450 is powered by a tamper proof sealed in lithium cell giving a completely wire free installation with a 10 year life and connects wirelessly usingRadioLINK interconnection technology so once in place you will need toHouse Codethe switch into the alarm system.Technical SpecificationSupply Voltage 3V Lithium Battery Powered for life.Battery Life 10 years normal operating conditions.Communication 868.499Mhz RadioLINK protocol.Fixing Wall mounting fixtures supplied.Operating Temperature 0C to 40C.Humidity Range 15 to 95 relative humidity.Button functionsTest Test alarms.Locate Identify triggered alarms.Silence Silence alarms.IndicatorsFire Illuminates when fire detected.CO Illuminates when CO detected.EOL illuminates to indicate End of Life.Memory Identifies previously triggered alarms.Diagnostics Walk round test Extended two minute test.Plastic Material UL94HB.Dimensions Product 90mm x 90mm x 30mm.Dimensions Boxed 153mm x 153mm x 40mm.Weight 110g product only 185g boxed.Guarantee 5 years.Approvals CE certified RF EN 300 220-2 EMC EN 301 489-1 EN 301 489-3 EMC.

GBP 85.26
1

Aico EI660i Multi-Sensor Fire Alarm With 10 Year Lithium Cells With AudioLINK

Aico Ei3024 230v 3000 Series Optical and Heat Multi-Sensor Fire Alarm

Aico Ei3024 230v 3000 Series Optical and Heat Multi-Sensor Fire Alarm

Aico Ei3024 230v 3000 Series Optical and Heat Multi-Sensor Fire AlarmThe Ei3024 Multi-Sensor Fire Alarm contains both Optical and Heat sensors to provide total fire coverage. Intelligent software allows it to detect all fire types TF1 to TF6 TF8 surpassing traditional single sensor Alarms. In addition the chamber design integrated insect screen and unique dust compensation algorithm reduce the risk of false alarms. The Ei3024 runs on 230V AC mains power. In the event of mains failure the 10 Year built in tamper-proof rechargeable lithium cells will provide back-up supply and continuous operation.The Ei3024 contains AudioLINK technology which allows you to extract real time data from the alarm directly to a smartphone or tablet via the AudioLINK App. The memory feature allows an alarm that has previously activated to be easily identified through the red flashing LED. The Ei3024 self tests its sensors battery and internal circuitry every 48 seconds. Any fault condition found will be indicated by a combination of yellow LED flashes andor audible beeps.The Ei3024 is fitted with a large central Test Silence button to facilitate frequent testing of the alarm and system. The silence function allows the alarm system to be silenced in the case of a false nuisance alarm and low battery fault beeps. SmartLINK compatible - plug in an Ei3000MRF module for wireless interconnection data extraction and real-time notifications of alarm activations and events via the SmartLINK Gateway and Portal.Key FeaturesSensor Types Optical Thermistor10 year lifeEasi-fit baseDust compensation unique self-monitoring mechanismAudioLINK data extraction technologyCompatible with other Aico mains powered unitsAdd an Ei3000MRF module for wireless interconnection and data extractionMains powered with 10 year rechargeable lithium cell back-upContains both an Optical and Heat sensor for a total fire responseSupply Voltage 230V AC 50HzPower Consumption 0.25W standbyBattery Back-up Rechargeable lithium cellsSound Level 85dBA at 3mButton Test Checks sensors electronics and sounderSilence Function Silences alarm for 10 minutesSilence Function Silences fault beeps for 12 hoursAudioLINK EnabledSmartLINK Compatible via the Ei3000MRF ModuleIndicator LEDS Green power. Red alarm silence mode memory. Yellow fault eventMemory Records last alarm eventFixing easi-fit base suppliedOperating Temperature -10C to 40CHumidity Range 15 to 95 relative humidityPlastic Material UL 94 V0 flame retardantDimensions Product 150mm x 66mmDimensions Boxed 180mm x 155mm x 70mmWeight 346g product only 412g boxedGuarantee 5 years

GBP 95.08
1