28 results (0,17027 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Aico EI650i Optical Smoke Alarm - 10 Year Lithium Battery Powered

Aico EI144E Heat Alarm - 230V with Alkaline Battery Back-up - Easi-fit Base

Aico Ei630iRF RadioLINK Heat Alarm - 10 Year Lithium Battery Powered with AudioLink

Aico EI1000G SmartLINK Gateway - Mains with Lithium Back-up

Aico EI1000G SmartLINK Gateway - Mains with Lithium Back-up

Aico EI1000G SmartLINK Gateway - Mains with Lithium Back-upThe SmartLINK Gateway is designed for use with the Aico RF devices. It provides a mechanism to transfer information from the RF network to a portal over the GSM network.It is mains powered with a rechargeable battery backup that can provide up to 72hrs of power supply in case of mains failure.Connected devices events are processed by the Gateway as they occur and cover events such asFire AlarmCO level detected High Medium LowButton TestMains Absent FaultHead OKHead RemovedEnd of lifeTo ensure the safety of the data it is encrypted in both directions during transmission using AES128 encryption.In addition for ease of installation the SmartLINK App available on Android iOS provides a step-by-step guide for the installation of the Gateway and the Aico RF devices.All data sent is accessible from a web portal where alerts can be set up to be delivered by email or SMS. Reports can also be run from the web portal to facilitate the management of the Alarms fitted.The data on the portal is securely stored and is only available to the associated client.Key FeaturesEnables remote management of RF AlarmsReceives RF specific data from RF devicesTransmits data over GSM networkNot GSM provider dependentBidirectional data encryptionUnique House Coding featureEasy setup and configurationCompatible with SmartLINK RadioLINKProvides specific data from radio frequency devicesHeart beat every 12 hours which gets sent to the portalTo connect to your smart device and portal you simply scan QR codes on alarm and moduleEasy installation and configurationTransmits data over GSM networkUnique house coding featureData upload 2G GSM network roaming sim card supplied no subscription necessaryFrequency 868MHz band 1 duty cyclePower usage 40mAVoltage 230VBattery back-up Rechargeable batteryProtocol Proprietary RF Protocol using multi-path multi-repeater mesh architectureRF Range 100 metres in free air depending on obstructionsNumber of devices Up to 12 RF devicesIndicator LEDs 3 colour LED blue green and redData requirements Monitoring via Ei1000G gateway download via EiUSB1Operating temperature -10C to 40CHumidity range 15 to 95 relative humidityMaterial PlasticHeight 150mmWidth 145mmDepth 55mm

GBP 350.89
1

Aico EI660iRF Multi-Sensor RF Fire Alarm With 10 Year Lithium Cells with AudioLINK amp RadioLINK

Aico Ei116 Anti-Vandal Cage to Fit Ei2110 160RC amp 140RC Series Alarms

Aico RadioLINK Alarm Controller Ei450

Aico RadioLINK Alarm Controller Ei450

Aico RadioLINK Alarm Controller Ei450The Ei450 is used to control all the alarms in a system from one place. We highly recommend fitting a control switch if you have smoke heatand carbon monoxide alarms on the same system as its essential that you can tell which alarm has sounded. From then you can identifywhich danger is present and the action you should take.The Ei450 contains LEDs which clearly display which danger has activated the alarm helping to you take the appropriate action as quickly as possible.Control Switchs increases the flexibility and user friendliness of the alarms by allowing the user to remotely Test Locate and Silencealarms in the systemTestThe alarm systemLocate The alarm that has been activatedSilence Any nuisance alarmsThe Ei450 is powered by a tamper proof sealed in lithium cell giving a completely wire free installation with a 10 year life and connects wirelessly usingRadioLINK interconnection technology so once in place you will need toHouse Codethe switch into the alarm system.Technical SpecificationSupply Voltage 3V Lithium Battery Powered for life.Battery Life 10 years normal operating conditions.Communication 868.499Mhz RadioLINK protocol.Fixing Wall mounting fixtures supplied.Operating Temperature 0C to 40C.Humidity Range 15 to 95 relative humidity.Button functionsTest Test alarms.Locate Identify triggered alarms.Silence Silence alarms.IndicatorsFire Illuminates when fire detected.CO Illuminates when CO detected.EOL illuminates to indicate End of Life.Memory Identifies previously triggered alarms.Diagnostics Walk round test Extended two minute test.Plastic Material UL94HB.Dimensions Product 90mm x 90mm x 30mm.Dimensions Boxed 153mm x 153mm x 40mm.Weight 110g product only 185g boxed.Guarantee 5 years.Approvals CE certified RF EN 300 220-2 EMC EN 301 489-1 EN 301 489-3 EMC.

GBP 85.26
1

Aico EI660i Multi-Sensor Fire Alarm With 10 Year Lithium Cells With AudioLINK

Aico Ei414 RadioLINK FireCO Alarm Interface

Aico Ei414 RadioLINK FireCO Alarm Interface

Aico Ei414 RadioLINK FireCO Alarm InterfaceThe Ei414 Fire CO Alarm Interface provides either a wireless interface via RF or a hard wired interface via a link cable between a RadioLINK Alarm system and a Warden Call Telecare System.The Ei414 decodes RF Fire and or CO signals from the RadioLINK and RadioLINK devices and activates the relevant onboard relays. The relays must be wired to the universal RF transmitters or via a special link cable to the Warden Call Systems. The Warden Call System in turn is programmed to perform the desired function on receipt of these signals.The Ei414 can deliver either a pulse signal or a continuous switched signal via the relays to the universal transmitters. The specific signal type will be determined by the requirement of the OEM universal sensor.The Ei414 contains x3 mains rated relays rated upto 250V AC 5 Amps. The relay contacts operate on mains power or on battery back-up cells in the event of a mains failure.The Ei414 has a key switch with 3 positionsON - Sends a signal from an Aico Alarm but not a ControllerTEST - Sends a signal from an Aico Alarm and ControllerOFF - No signal sent from an Aico Alarm or ControllerThe Ei414 uses RadioLINK multi-repeater multi-path technology to deliver very robust and reliable RF signal coverage. While designed primarily to interface with a Warden Call or similar Telecare system the versatility of the Ei414s electrically isolated contacts means it can be used to switch many other OEM devices.Key FeaturesConnect your Smoke Heat and CO Alarms system to external devices e.g. Warden Call and other Telecare systemsPowered by either mains 240V AC or 10-30V DC external sourceRechargeable lithium cell back-upVolt free contacts outputs NO NC for Alarm Fire CO messages and fault messages3 position key switchClear Indicator LEDsContains for wireless communication with Alarms and DevicesAllows for simple testing of domestic and external systemsConnects wirelessly with all other Aico wireless interconnection productsMains powered with rechargeable lithium cell back upInterfaces with TelecareWarden Call devices Sprinkler systems and many moreUses RadioLINK wireless interconnection technology to connect with domestic alarms and accessories

GBP 252.16
1

Aico EI1025 Temperature Humidity and CO2 Environmental Sensor

Aico EI1020 Temperature and Humidity Environmental Sensor

Aico Ei3018 230v 3000 Series Carbon Monoxide Alarm

Aico Ei3018 230v 3000 Series Carbon Monoxide Alarm

Aico Ei3018 230v 3000 Series Carbon Monoxide AlarmThe Ei3018 is a Carbon Monoxide CO Alarm powered by 230V AC mains power and has built in tamper proof rechargeable lithium cells that act as a battery back up in the event of mains failure. These rechargeable lithium cells are designed to last the life of the CO alarm. The Ei3018 has a high performance proven electrochemical sensor 10 year life to sense CO presence. The sensor is individually calibrated and tested in CO gas to ensure accuracy. In alarm the flash rate of the red LED indicates the level of CO detected.The Ei3018 contains AudioLINK technology which allows you to extract real time data from the alarm directly to a smartphone or tablet via the AudioLINK App. The Ei3018 can operate as a standalone alarm or can be interconnected either by hard-wire or wirelessly using the EI3000MRF module enabling it to communicate with compatible alarms and accessories. Up to 12 devices can be interconnected.The memory feature allows an alarm that has previously activated to be easily identified through the red flashing LED. The alarm is fitted with a large Test Silence button to facilitate frequent testing of the alarm and system. The silence function allows the alarm system to be silenced in the case of a false nuisance alarms and low battery fault beeps. SmartLINK compatible - plug in an Ei3000MRF module for wireless interconnection data extraction and real-time notifications of alarm activations and events via the SmartLINK Gateway and Portal.Key FeaturesSensor Types Electrochemical cell10 year lifeEasi-fit baseAudioLINK data extraction technologyCompatible with other Aico mains powered devicesAdd an Ei3000MRF module for wireless interconnection and data extractionMains powered with 10 year rechargeable lithium cell back-upContains our proven Electrochemical CO sensorSupply Voltage 230V AC 50HzPower Consumption 0.25W standbyBattery Back-up Rechargeable lithium cellsSound Level 85dBA at 3mButton Test Checks sensors electronics and sounderSilence Function Silences alarm for 10 minutesSilence Function Silences fault beeps for 12 hoursAudioLINK EnabledSmartLINK Compatible via the Ei3000MRF ModuleIndicator LEDS Green power. Red pre alarm alarm silence mode memory. Yellow fault eventMemory Records last alarm eventOperating Temperature -10C to 35CHumidity Range 15 to 95 relative humidityPlastic Material UL 94 V0 flame retardantDimensions Product 150mm x 55mmDimensions Boxed 180mm x 155mm x 62mmWeight 310g product only 376g boxedGuarantee 5 years

GBP 89.60
1

Aico Plug-in RadioLINK module Ei200MRF

Aico RadioLINK Switched Input Module Ei408

Aico RadioLINK Switched Input Module Ei408

Aico RadioLINK Switched Input Module Ei408The Ei408 Switched Input Modulehas been designed totriggers the alarmsin a system if anexternal device isactivated such as a sprinkler system.The Ei408 is powered by a tamper proof sealed in lithium cell giving a completely wire free installation with a 10 year life.The unituses RadioLINK to wirelessly interconnect with the rest of the alarm system so once in place you will need toHouse Codethe switch into the alarm system.Operation of the Ei408On receiving a volt-free switched hardwired signal the unit will transmit a RadioLINK alarm signalThe indicator will flash green every 40 seconds to indicate that the lithium cell power supply is healthyIf the Lithium cells are depleted the indicator will flash amber every 10 seconds and the unit needs replacingTechnical SpecificationFor use with 140RC when using anEi168Rc RadioLINK base160ewhen using andEi100MRF RadioLINK module Ei3000 series when using anEI3000MRF SmartLINK moduleor any RadioLINK enabled CO alarms.Eliminates the need for any cabling between the Ei408 and the smoke heat and CO alarms used in the system.Features built-in tamper proof FDK Lithium cells capable of lasting at least 10 years under normal usage. Operating the yellow onoff switch sited on the back of the unit activates the cells. The LED on the front cover will flash red amber green on power up after this it will flash green every 40 seconds to indicate a healthy power supply.Low battery warning signal LED indicator flashes amber every 10 seconds to indicate depleted battery. If this occurs the complete unit should be replaced.The unit has built-in wiring terminals for connection to an external set of volt-free switched contacts. On the contacts closing the Ei408 will send out a RadioLINK alarm signal to trigger all other RadioLINK devices within the system.Radio frequency 868 MHz Band in accordance with RTTE Directive 19995EC this band has been designated for use with security products and only allows a 1 duty cycle so continuous transmission and interference form external sources is extremely remote and would be illegal.Range The type of building will be the major limiting factor e.g. the number and type of wallsceilings that the radio signal has to pass through. As a guide 30m should be the maximum distance between any of the RadioLINK units in the system.Up to 20 RadioLINK units can be used in one system. Range will be the limiting factor.Units are in Factory Code mode when received they will all communicate with each other. They must be House Coded to eliminate the risk of adjacent properties communicating with each other. After House Coding they will only communicate with other RadioLINK units coded at the same time.House Code Operate the House Code switch on all RadioLINK units in the system see the instructions supplied with other RadioLINK units being used. The green LED on the cover of the Ei428 will change to red and flash slowly this indicates that it will receive the unique serial numbers being sent by all other RadioLINK units in House Code. The number of flashes of the LED indicates the number of units in the system The Ei428 will return to normal standby mode automatically after 15 minutes. Pressing the House Code switch again will return it to normal standby immediately.The Ei408 is conformant to EN300220-1 2000-09 RF Performance and EN301489-3 2002-08 EMC.Designed for surface mounting.Ambient Temperature Range 4C to 40C. Humidity Range 0 to 90 relative humidity.Dimensions 90mm x 90mm x 43mm. Weight inclusive of packaging 240g.5 year guarantee.Manufactured in Ireland.Key FeaturesStand alone unit designed for use with RadioLINK bases AccessoriesAccepts a hardwired input e.g. from sprinkler systemVisual RF transmission and power indicatorPowered by built-in Lithium cellsUnique House CodingLow battery power warningRF performance to EN 300220-15 Year Guarantee

GBP 61.67
1

Aico EI3028 Series Heat amp Carbon Monoxide Multi-Sensor Fire Alarm

Aico EI3028 Series Heat amp Carbon Monoxide Multi-Sensor Fire Alarm

Aico EI3028 Series Heat Carbon Monoxide Multi-Sensor Fire AlarmThe Ei3028 is a Multi-Sensor Heat and Carbon Monoxide CO Alarm. It contains our proven fast acting Class A1 Thermistor sensor to detect fire as well as our proven electrochemical CO sensor to detect the presence of toxic levels of CO. This provides protection from both Fire and CO in one alarm. The Ei3028 runs on 230V AC mains power. In the event of mains failure the 10 Year built in tamper-proof rechargeable lithium cells will provide back-up supply and continuous operation.The Ei3028 contains AudioLINK technology which allows you to extract real time data from the alarm directly to a smartphone or tablet via the AudioLINK App. During an alarm Fire or CO indicators will flash on the Alarm to indicate what has been detected. There will also be a different alarm sound depending on what has triggered the alarm. The Ei3028 is fitted with a large Test Silence button to facilitate frequent testing of the alarm and system. The silence function allows the alarm system to be silenced in the case of a false nuisance alarms and low battery fault beeps.The Ei3028 self-tests its sensors battery and internal circuitry every 48 seconds. Any fault condition found will be indicated by a combination of yellow LED flashes andor audible beeps. SmartLINK compatible - plug in an Ei3000MRF module for wireless interconnection data extraction and real-time notifications of alarm activations and events via the SmartLINK Gateway and Portal.Key FeaturesSensor Type Thermistor Electrochemical CO10 year lifeEasi-fit baseHeat or CO indicator on alarm headAudioLINK data extraction technologyCompatible with other Aico mains powered unitsAdd and Ei3000MRF for wireless interconnection and data extractionMains powered with 10 year rechargeable lithium cell back-upContains both a Heat and Electrochemical CO sensor Heat and CO coverage in one alarmSupply Voltage 230V AC 50HzPower Consumption 0.25W standbyBattery Back-up Rechargeable lithium cellsSound Level 85dBA at 3mButton Test Checks sensors electronics LED displays and sounderSilence Function Silences alarm for 10 minutes if alarm is triggered by heat or once for 4 minutes in case of CO event.Silence Function Silences fault beeps for 12 hoursAudioLINK EnabledSmartLINK Compatible via the Ei3000MRF ModuleIndicator LEDS Green power. Red pre-alarm CO only alarm silence mode memory or battery event. Yellow fault eventMemory Records last alarm eventFixing easi-fit base suppliedOperating Temperature -10C to 35CHumidity Range 15 to 95 relative humidityPlastic Material UL 94 V0 flame retardantDimensions Product 150mm x 66mmDimensions Boxed 180mm x 155mm x 72mmWeight 318g product only 384g boxedGuarantee 5 years

GBP 117.24
1

Aico SAB300R 230V Xenon Strobe with Red Lens

Aico SAB300C 230V Xenon Strobe with Clear Lens

Aico Ei208 Carbon Monoxide CO Alarm

Aico EI650iRF RadioLINK Optical Smoke Alarm - 10 Year Lithium Battery Powered - With AudioLink

Aico EI650iRF RadioLINK Optical Smoke Alarm - 10 Year Lithium Battery Powered - With AudioLink

Aico EI650iRF RadioLINK Optical Smoke Alarm - 10 Year Lithium Battery Powered - With AudioLink The Ei650iRF is a battery-powered Optical Smoke Alarm. It is able to wirelessly interconnect with any other RadioLINK RadioLINK and SmartLINK products. Contains an Optical Smoke ChamberThe Ei650iRF RadioLINK Optical Smoke Alarm is best for detecting slow smouldering fires commonly produced by electrical fires or sofas and is less likely to react to cooking smells if fitted in the hallway next to the kitchen.Battery and LifespanThis battery powered alarm contains sealed in tamper-proof lithium battery that will last for the full 10-year life of the alarm. The alarm is not powered until it is twisted on the mounting base thus avoiding battery power consumption during storage and prior to installation.Built-in RadioLINK Wireless Interconnection TechnologyRadioLINK wireless interconnection technology is built-in to this alarm. RadioLINK uses Radio Frequency signals to link alarms together with added functionality. All RadioLINK alarms and devices should be House Coded together upon install.Key FeaturesOptical sensor with dust compensation technologyBuilt-in AudioLINKUses built-in RadioLINK technology to interconnect and for data extractionConnects wirelessly with all other Aico wireless interconnection productsBattery powered with a sealed-in lithium batteryEasy to fit twist on base and multi-fixings with an anti-tamper locking option10-year lifeGrade F1 and compliant with Scottish legislationKitemarked to BS EN 146042005

GBP 94.61
1

Aico RadioLINK Alarm for Deaf 230V with Strobe Vibrating Pad Ei170RF

Aico RadioLINK Alarm for Deaf 230V with Strobe Vibrating Pad Ei170RF

Aico RadioLINK Alarm for Deaf 230V with Strobe Vibrating Pad Ei170RFTheEi170RF is a mains powered with rechargeable battery back up alarm kitfor the deaf and hard of hearing. Thekit contains aXenon strobe lightthat provide and plug in vibrating pillow pad that will activate when the interconnected alarms are triggered to alert theuser tothe danger.TheEi170RF kit is compatible with the3000Multi-Sensor Fire Alarm Ei2110e160e Seriesalarms and 140RC Series smoke and heat alarms along with any interconnected Carbon Monoxide alarms. This kit links into the alarm system usingRadioLINK wireless interconnection technology making it easier to add into a system and causing less disruption to the occupants on installation.An integral Test button is also present on the front of the unit allowing an easy means of testing the strobe vibration pad and the RadioLINK enabled alarms in the system.As with other RadioLINK products the Ei170 Alarm Kit for the Deaf and Hard of Hearing will need to belinked into the alarm system or House Coded. View ourstep by step guide to House Coding here.Technical Specification A strobe and vibrating pillow pad kit designed to give warning of fire to deaf and hard of hearing occupants. For use with30002110e160eand 140RC Series smoke and heat alarms when used with aRadioLINK baseRadioLINK moduleor theSmartLINKmoduleRadioLINK Carbon MonoxideCO alarms. It can also be used with all other RadioLINK devicesancillaries including the 600 Series RadioLINK smoke and heat alarms.Eliminates the need for any cabling between the Ei170 RF and the smoke heat andor CO alarms used in the system.Requires 230V AC 50Hz mains power supply.The unit has a built-in high-intensity Xenon strobe flash rate 0.8Hz with a wide light output angle.Built-in long life sealed lead acid rechargeable battery to provide back-up power in the event of mains failure. Standby capacity 7 days followed by 15 minutes alarm lifespan 5 years in normal use. The battery is connected by plugging it into the socket in the bottom of the battery box.Comprehensive indicating lights on front of the unitPower Constant green to indicate mains is present flashes amber every 4 seconds with mains absent.Alarm red Flashes every second when the unit has been triggered.Fault amber Flashes every 4 seconds if a fault is detected with panelvibration pad. Flashes every 4 seconds if rechargeable back-up battery is depleted or faulty.RF status blue Illuminates when RF signal is being sent flashes in House Code mode to indicate the number of units learned. Flashes every 40 seconds if RadioLINK smoke alarms have a low battery.Mains transformer is mounted in separate and hard-wired to the strobe unit with 4m of low voltage cable. Supplied with 2m of mains cable and pre-wired 13 amp plug with a 3 amp fuse.Integrated Test button on the front of the unit. Pressing this checks strobe and control circuitry and also send out a RadioLINK alarm signal to other units in the system.The vibrating pillow pad is suitable for mounting under mattresses or pillows and produces strong pulsed vibrations suitable for waking sleepers. Supplied with locking plug and 5m of pre-wired cable.Connecting sockets on rear of unit as followsVibration Pad socket Locking socket JST type VHR-2N. Is pulsed when unit is in alarm.Auxiliary sockets Two auxiliary sockets are available on the rear of the unit to allow connection of additional strobes etc. Locking sockets JST type VHR-2N. Each provides 12V200mA when unit is in alarm. Can be used for any of the following Auxiliary strobe Ei178 auxiliary vibration pad Ei174 or for triggering a radio pager.A clock input socket is also available. This is for use will alarm clocks that have a 3.5mm mono jack output and saves the need for multiple vibration pads. An input of 5-12V AC or DC mains isolated will turn on the vibration pad constant vibration pattern but will not activate the strobe or auxiliary sockets.Radio frequency 868MHz band in accordance with RTTE Directive 19995EC this band has been designed for use with security products and only allows a 1 duty cycle so continuous transmission and interference from external sources is extremely remote and would be illegal. Complies with EN300220-2V2.1.1.RF Range The type of building will be the major limiting factor e.g. the number and type of wallsceilings that the radio signal has to pass through. As a guide 30m should be the maximum distance between any of the RadioLINK units in the system.Up to 12 RadioLINK units can be used in one system. For larger systems contact our Technical Department for guidance.

GBP 279.71
1

Aico RadioLINK Carbon Monoxide Smoke Alarm Ei208WRF

Aico Ei1529RC Alarm Control Switch

Aico Ei1529RC Alarm Control Switch

Aico Ei1529RC Alarm Control SwitchThe Ei1529RC is a remote control switch that runs on 230V AC mains power. It is designed for use with 2100 160RC and 140RC series smoke and heat alarms and 260RC series carbon monoxide alarms.It increases the flexibility and user friendliness of the alarms by allows the user to remotely Locate Hugh and Test the alarms in the systemLocate The source of the alarmHush any nuisance alarmsTest the alarm systemMains Check provides warning of a mains failureKey FeaturesInstall as part of the system to get more control over your alarmsMains poweredHard wired interconnectionTest Locate and SilenceCompatible with 3000 Ei2110e Multi-Sensor Fire Alarm 160e Series alarms 140RC Series alarms and hard wired interconnected Carbon Monoxide alarmsCompiles with electrical safety requirements EN61000-6-12007 Et EN61000-6-22005 EMC Directive and EN600652001 A122011 Low voltage directiveCarries the CE mark to indicate conformance to Low Voltage and Electromagnetic Compatibility DirectivesWall mounted for ease of use can be fixed with surface mount box supplied or will fit a standard recessed box not suppliedSuitable for siting at any convenient point in the property. Up to 4 x Ei1529RC switches can be installed in a hardwired system along with a maximum of 16 x 3000 2110e 160e or 140RC Series smoke and heat alarms or 261ENRC Carbon Monoxide alarmsThe unit incorporates 3 switches marked Locate Test and Hush. These provide control features as detailed below and a mains check function as detailed below

GBP 48.71
1

Aico Ei3016 230v 3000 Series Optical Smoke Alarm

Aico Ei3016 230v 3000 Series Optical Smoke Alarm

Aico Ei3016 230v 3000 Series Optical Smoke AlarmThe Ei3016 Optical Smoke Alarm contains a high-performance optical smoke sensor which is best for detecting slow smoldering fires. In addition the smoke chamber design integrated insect screen and unique automatic dust compensation reduce the risk of false alarms. The Ei3016 runs on 230V AC mains power. In the event of mains failure the 10 Year built in tamper-proof rechargeable lithium cells will provide back-up supply and continuous operation.The Ei3016 contains AudioLINK technology which allows you to extract real time data from the alarm directly to a smartphone or tablet via the AudioLINK App. The Ei3016 self-checks its sensor battery and internal circuitry every 48 seconds. Any fault condition found will be indicated by a combination of yellow LED flashes andor audible beeps. The memory feature allows an alarm that has previously activated to be easily identified through the red flashing LED.The alarm is fitted with a large Test Silence button to facilitate frequent testing of the alarm and system. The silence function allows the alarm system to be silenced in the case of a false nuisance alarms and low battery fault beeps. SmartLINK compatible - plug in an Ei3000MRF module for wireless interconnection data extraction and real-time notifications of alarm activations and events via the SmartLINK Gateway and Portal.Key FeaturesContains a high-performance optical sensorMains powered with 10-year rechargeable Lithium cell back-upCompatible with interconnection and monitoring technologyAudioLINK TM Data extraction technologyDust compensation - unique self-monitoring mechanismEasi-Fit base10 Year lifeSensor Type OpticalSupply Voltage 230V AC 50HzPower Consumption 0.25W standbyBattery Back-up Rechargeable lithium cellsSound Level 85dBA at 3mButton Test Checks sensor electronics and sounderSilence Function Silences alarm for 10 minutesSilence Function Silences fault beeps for 12 hoursAudioLINK EnabledSmartLINK Compatible via the Ei3000MRF ModuleIndicator LEDS Green power. Red alarm silence mode memory. Yellow fault eventMemory Records last alarm eventFixing easi-fit base suppliedOperating Temperature -10C to 40CHumidity Range 15 to 95 relative humidityPlastic Material UL 94 V0 flame retardant

GBP 72.89
1

Aico RadioLINK Relay Module with 5A Relay amp Rechargeable Battery Back-up Ei428

Aico RadioLINK Relay Module with 5A Relay amp Rechargeable Battery Back-up Ei428

Aico RadioLINK Relay Module with 5A Relay Rechargeable Battery Back-up Ei428The Ei428 is a mains powered relay module that triggers external devices such as a strobe light or telecare deviceif the alarmsin the propertyactivate.For use with 140RC when using anEi168Rc RadioLINK base160ewhen using andEi100MRF RadioLINK module Ei3000 series when using anEI3000MRF SmartLINK moduleor any RadioLINK enabled CO alarms.The module has additional trunking knock outsto make as easy to install as possibleand is designed to fit underneath the space of easi-fit or RadioLINK base. However a cover Ei128COV is available if needed and containsa set of volt free contacts as standard.The replay module can beconfigured to give a 230V output or a 24V output using an external 24V supplyOperation of Ei428 RadioLINK Relay ModuleOn receiving a RadioLINK signal from one of the alarms in the system the relay contacts will be operated causing a signal to be sent to the system to which it is connectedThe indicator on the cover will show a constant green light when the mains power is connected.Technical SpecificationA relay module with cover to allow flexibility in siting.For use with 140RC when using anEi168Rc RadioLINK base160ewhen using andEi100MRF RadioLINK module Ei3000 series when using anEI3000MRF SmartLINK moduleor any RadioLINK enabled CO alarms.Eliminates the need for any cabling between the Ei428 and the smoke heat and CO alarms used in the system.Requires 230V AC Mains Power Supply Green LED to indicate mains power is present.Features built-in tamper proof Rechargeable Vanadium Pentoxide lithium standby cells capable of lasting at least 10 years and powering the module initially for at least 2 months in the event of mains power failure. The cell manufacturer endorses a minimum 10-year life expectation for the rechargeable cells which are activated by operating the battery switch inside the module.The product is CE marked to indicate conformance to BS EN 600651998 Electrical Safety EN300220-1 V1.3.1 2000-09 RF Performance EN301489 V1.4.1 2002 08 EMC and has been 3rd party tested for electrical safety in accordance with Annex K of BS 5446 Pt.12000.Radio frequency 868 MHz Band in accordance with RTTE Directive 19995EC this band has been designated for use with security products and only allows a 1 duty cycle so continuous transmission and interference form external sources is extremely remote and would be illegal.Range The type of building will be the major limiting factor e.g. the number and type of wallsceilings that the radio signal has to pass through. As a guide 30m should be the maximum distance between any of the RadioLINK units in the system.Up to 20 RadioLINK units can be used in one system. Range will be the limiting factor.Low back-up warning signal LED indicator flashes RED every 10 seconds to indicate that the lithium cells are depleted.Units are in Factory Code mode when received they will all communicate with each other. They must be House Coded to eliminate the risk of adjacent properties communicating with each other. After House Coding they will only communicate with other RadioLINK units coded at the same time.House Code Operate the House Code switch on all RadioLINK units in the system see the instructions supplied with other RadioLINK units being used. The green LED on the cover of the Ei428 will change to red and flash slowly this indicates that it will receive the unique serial numbers being sent by all other RadioLINK units in House Code. The number of flashes of the LED indicates the number of units in the system The Ei428 will return to normal standby mode automatically after 15 minutes. Pressing the House Code switch again will return it to normal standby immediately.Volt free contacts Normally Open or Normally Closed rated up to 240V AC 5 Amps making it suitable for use with a wide range of AC or DC voltages. The relay contacts operate on mains power or on back-up cells in the event of mains failure.A RadioLINK Manual Call Point Ei407 and remote control switches Ei450 Ei412 and Ei411H are also available for use in the system. See separate specification sheets for further information.Features 1 x 25mm trunking for for surface wiring and centre knockout for recess wiring.Ambient Temperature Range 4C to 40C. Humidity Range 0 to 90 relative humidity.Dimensions 140mm diameter x 27mm depth weight inclusive of packaging 220g.5 year guarantee.Manufactured in Ireland.Key FeaturesDesigned for use with all RadioLINK Professional alarms and accessoriesRechargeable Lithium battery back-upVolt-free contacts as supplied for multiple usesCan be configured to switch a 230V or 24V outputTrunking knock-outs for easy and neat wiringContinuous or Pulse operation5 Year Guarantee

GBP 98.36
1