25 results (0,16336 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Apollo Backplate 45681-233APO

Apollo Detector Ceiling Tile Mounting Box - 45681-309APO

Apollo SA4700-100APO Intelligent Switch Monitor

Apollo SA4700-102APO Intelligent Input Output Unit

Apollo Sounder Ceiling Tile Mounting Box - 45681-310APO

Apollo SA6700-100APO Intelligent Twin Switch Monitor

Apollo Xpander Diversity Loop Interface Unit - XPA-IN-14050-APO

Apollo Xpander Diversity Loop Interface Unit - XPA-IN-14050-APO

Please note The XPA-IN-14050-APO does not support CoreProtocol installations.Apollo Xpander Diversity Loop Interface Unit - XPA-IN-14050-APOThe XPander Diversity Loop Interface Unit can monitor up to 31 XPander devices and report each devices status to an intelligent fire control panel.Brand InformationXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves. The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface.The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.Key FeaturesConnects up to 31 XPander devices to an ApolloAddressable loopTranslates radio signals from XPander detectors to the fire control panelBuilt-in loop isolatorLoop-poweredDiversity aerial design for improved signal integrityThe entire XPander product line has a temporary four-month supply disruption starting from November 2021 with supply expecting to resume in February 2022.

GBP 337.68
1

Apollo SA4700-104APO Intelligent Twin Input Output Unit

Apollo XP95 Intelligent Duct Smoke Detector - 53546-022APO

Apollo Soteria Dimension IR Optical Detector FL5100-600APO

Apollo XP95 Intrinsically Safe Red Manual Call Point MEDC Style 55000-961APO

Apollo Soteria Dimension Specialist IR Optical Detector FL6100-600APO

Apollo Soteria Dimension Specialist IR Optical Detector FL6100-600APO

Apollo Soteria Dimension Specialist IR Optical Detector FL6100-600APOThe Soteria Dimension Specialist Optical Detector contains two daylight filtered photo-diodes and three IR emitters in different positions and angles. Different combinations of these are used to act as smoke sensors and proximity sensors to measure the smoke level at the detector and to detect any physical obstruction or interference of the detector.As this detector is chamberless an IR LED emits light outside the detector. The light is scattered by smoke back towards the detector and registered by a photo-diode.A pair of microprocessors control these sensors setting the sensor timings and using a digital phase-sensitive detection algorithm to reduce noise and the effect of background light. They then provide digital filtering for transient rejection compensation for drift and temperature and ultimately make an alarm decision.Key FeaturesLow profile designUtilises digital CoreProtocol communicationsCompatible with Discovery and XP95 systemsIntegrated switchable isolator as standard8-way DIL switch addressingDrift compensationFasTest for quicker testingTricoloured LED status indicatorComprehensively tested to exceed EN 54-7 and EN 54-17 standardsRuggedized metal face plate which is secured with anti-tamper screwsDesigned and tested to meet the requirements of Ministry of Justice specification STDESPEC038Independently certified to DHF TS001 for anti-ligature use in specialist areas

GBP 366.25
1

Apollo Orbis Non-Latching Optical Smoke Detector ORB-OP-02032-APO

Apollo Orbis Optical Smoke Detector with Flashing LED ORB-OP-12003-APO

Apollo Orbis Optical Smoke Detector with Flashing LED ORB-OP-12003-APO

Apollo Orbis Optical Smoke Detector with Flashing LED ORB-OP-12003-APO OperationApollos Orbis operates on the well-established light scatter principle. The remarkable optical design of the Orbis optical smoke detector allows it to respond to a wide spectrum of fires. The sensing chamber of the Orbis optical smoke detector contains an optical sensor which measures back-scattered light as well as the more usual forward-scattered light. Sensitivity to black smoke is greatly improved.The detector is calibrated so that Orbis is highly reliable in detecting fires but is much less likely to generate false alarms than earlier smoke detectors. The stability of the detectorhigh reliability low false alarm rateis further increased by the use of algorithms to decide when the detector should change to the alarm state. This removes the likelihood of a detector producing an alarm as a result of smoke from smoking materials or from another non-fire source.Brand FeaturesTimeSaver Base designed for fast installationStartUp for fast commissioningFasTest reduces maintenance timeautomatic drift compensation with DirtAlert warning to easily identify dirty detectorsSensAlert which indicates that the detector is not operating properlywide voltage and operating temperature rangesoptical sensor designed for high reliability and reduced false alarm incidencemultisensory smoke detector for detecting fast-burning firesflashing LED option

GBP 17.24
1

Apollo Orbis I.S. Optical Smoke Detector ORB-OP-52027-APO

Apollo Orbis Intrinsically Safe Optical Smoke Detector with Flashing LED ORB-OP-52028-APO

GBP 83.96
1

Apollo FL5100-660APO Soteria Dimension Optical Smoke Detector - Black

Apollo FL5100-660APO Soteria Dimension Optical Smoke Detector - Black

Apollo FL5100-660APO Soteria Dimension Optical Smoke Detector - BlackThe Apollo Soteria Dimension Optical Smoke Detector Black has an innovative design which differs from standard fire detectors having no chamber and being flush mounted. A new optical sensing technology is used to detect smoke particles outside the detector housing. A combination of Infra-Red IR LEDs and photo-diodes identify smoke particles detected just below the detector housing and initiates an alarm.OperationThe Soteria Dimension Optical Detector contains two daylight filtered photo-diodes and three IR emitters in different positions and angles. Different combinations of these are used to act as smoke sensors and proximity sensors to measure the smoke level at the detector in the event of a fire and to detect any physical obstructions.As this detector is chamberless an IR LED emits light outside the detector. The light is scattered by smoke back towards the detector and registered by a photo-diode.A pair of microprocessors control these sensors setting the sensor timings and using a digital phase-sensitive detection algorithm to reduce noise and the effect of background light. They then provide digital filtering for transient rejection compensation for drift and temperature and ultimately make an alarm decision.The mode of operation may be selected at the fire control panel.Key FeaturesFlush mountedUtilises digital CoreProtocol communicationsCompatible with Discovery and XP95 systems not all features may be available when connected to an XP95Discovery panelIntegrated switchable isolator as standard8-way DIL switch addressingDrift compensationFasTest for quicker testingTricoloured LED status indicatorPolycarbonate moulding for colour stability and strengthComprehensively tested to exceed EN 54-7 and EN 54-17 standardsLocking mechanism grub screw

GBP 209.29
1

Apollo 58100-910APO Discovery Manual Call Point Red

Apollo 58100-910APO Discovery Manual Call Point Red

Apollo 58100-910APO Discovery Manual Call Point RedA seven-segment DIL switch enables addressing of each call point at commissioning stage. When operated the manual call point interrupts the polling cycle for a fast response. Bi-coloured LEDs indicate isolate and normal conditions.The Apollo Discovery Manual Call Point has been designed to operate on a loop of intelligent fire detection devices. An alarm is initiated by pressing the resettable element. The manual call point signals to the control and indicating equipment using an interrupt feature within the Apollo digital communication protocol.An alarm status is indicated by a yellow and black bar in the lower section of the resettable element and a red LED. The manual call point can be easily reset from the front using the supplied reset key. It is available in two versions with and without isolator. The manual call point is intended for indoor applications.A red alarm LED is provided on the manual call point. This LED is controlled independently of the manual call point by the fire control panel.Once activated the manual call point can be reset by inserting the reset key into front facing LED turning clockwise until a positive click and reset occurs. An additional pack of 10 reset keys can be purchased Part Number 44251-176. The isolated version of the manual call point incorporates a short circuit isolator which will ensure its operation in the event of a short circuit fault on the loop. Isolator operation is indicated by a yellow LED. For further details of the isolator refer to datasheet PP2090 available on request.This manual call point helps reduce installation time as all the initial installation cabling is wired to a terminal block which fits neatly in the back of the call point.

GBP 57.14
1

Apollo Discovery Marine Weatherproof Manual Call Point 58200-976MAR

Apollo Discovery Marine Weatherproof Manual Call Point 58200-976MAR

Apollo Discovery Marine Weatherproof Manual Call Point 58200-976MARThe Discovery Marine Manual Call Points has been designed for use in marine and offshore environments and are available in two versions for indoor and outdoor applications. Both versions are available with and without short circuit isolators.An alarm is initiated by pressing the resettable element. The Manual Call Point signals to the Control and Indicating Equipment using an interrupt feature within the Apollo Digital Protocol. An alarm status is indicated by a yellow and black bar in the lower section of the resettable element and a red LED. The Manual Call Point can be easily reset from the front using the supplied reset key.Discovery Marine analogue addressable fire detectors are suitable for larger vessels. The high specification range has been developed to meet the requirements of sophisticated systems. Discovery gives you total reassurance in installations where it is necessary to adapt detection to different operating environments and where protection against unwanted alarms is paramount.OperationThe address of each call point is set at the commissioning stage by means of a seven-segment DIL switch. On the indoor versions the address switch is accessible without removing the call point from the mounting surface. A red alarm LED is provided on the call point. This LED is controlled independently of the call point by the control panel.This Manual Call Point helps reduce installation time as all the initial installation cabling is wired to a terminal block which fits neatly in the back of the call point. Once activated the Discovery Marine Manual Call Point can be reset by inserting the reset key into the front facing LED turning clock wise until a positive click and reset occurs.Key FeaturesApproved for use in the marine environmentFive response modes for environmental adaptationDaynight switching for increased flexibilityDrift compensation for false alarm reductionUser programmability for dataXPERT card addressing for increased security

GBP 153.76
1

Apollo 58100-927APO Discovery Manual Call Point Yellow

Apollo 58100-927APO Discovery Manual Call Point Yellow

Apollo 58100-927APO Discovery Manual Call Point YellowA seven-segment DIL switch enables addressing of each call point at commissioning stage. When operated the manual call point interrupts the polling cycle for a fast response. Bi-coloured LEDs indicate isolate and normal conditions.The Apollo Discovery Manual Call Point has been designed to operate on a loop of intelligent fire detection devices. An alarm is initiated by pressing the resettable element. The manual call point signals to the control and indicating equipment using an interrupt feature within the Apollo digital communication protocol.An alarm status is indicated by a yellow and black bar in the lower section of the resettable element and a red LED. The manual call point can be easily reset from the front using the supplied reset key. It is available in two versions with and without isolator. The manual call point is intended for indoor applications.A red alarm LED is provided on the manual call point. This LED is controlled independently of the manual call point by the fire control panel.Once activated the manual call point can be reset by inserting the reset key into front facing LED turning clockwise until a positive click and reset occurs. An additional pack of 10 reset keys can be purchased Part Number 44251-176. The isolated version of the manual call point incorporates a short circuit isolator which will ensure its operation in the event of a short circuit fault on the loop. Isolator operation is indicated by a yellow LED. For further details of the isolator refer to datasheet PP2090 available on request.This manual call point helps reduce installation time as all the initial installation cabling is wired to a terminal block which fits neatly in the back of the call point.

GBP 70.79
1

Apollo XP95 I.S. Manual Call Point - 55100-940APO

Apollo XP95 I.S. Manual Call Point - 55100-940APO

Apollo XP95 I.S. Manual Call Point - 55100-940APOThe XP95 IS Manual Call Point has been designed to operate on a loop of intelligent fire detection devices and when activated interrupts the polling cycle for a very fast response the intrinsically safe call point not only interrupts the polling cycle to indicate to the control panel that it has been operated but also reports its address and therefore an alarm and its location can be reported in less than 0.2 seconds.The XP95 IS manual call points have the same operating characteristics as the standard versions. They are available in two types of housing and in a number of versions. Designed specifically for use in atmospheres in which explosive mixtures are or may be present certain design considerations must be observed. The standard red IS manual call point is EN54-112001 compliant and has a resettable element. The range uses an IP67 weatherproof polycarbonate housing and is available in colours other than red.Key FeaturesReports an alarm in under 0.2 secondsWaterproof weatherproofIP67Designed for explosive mixture atmosphereOperationThe address of each call point is set at the commissioning stage by means of a seven-segment DIL switch. A red alarm LED is provided on the call point. This LED is controlled independently of the call point by the control panel.This Manual Call Point helps reduce installation time as all the initial installation cabling is wired to a terminal block which fits neatly in the back of the Call Point. Once activated the XP95 IS Manual Call Point can be reset by inserting the test key into the bottom of the unit until the key clicks into position. Remove the test key and push the front cover up until it clicks home

GBP 234.79
1

Apollo XP95 I.S. Intrinsically Safe Manual Call Point - 55200-940APO

Apollo XP95 I.S. Intrinsically Safe Manual Call Point - 55200-940APO

Apollo XP95 I.S. Intrinsically Safe Manual Call Point - 55200-940APOThe XP95 I.S. Manual Call Point has been designed to operate on a loop of intelligent fire detection devices and when activated interrupts the polling cycle for a very fast response. When activated the intrinsically safe call point not only interrupts the polling cycle to indicate to the control panel that it has been operated but also reports its address. Thus an alarm and its location can be reported in less than 0.2 seconds. Full details of the principles of operation and the electrical description are published in the XP95 Engineering Product Guide.XP95 I.S. manual call points have the same operating characteristics as the standard versions. They are available in two types of housing and in a number of versions. Designed specifically for use in atmospheres in which explosive mixtures are or may be present certain design considerations must be observed. The standard red I.S. manual call point is EN54-112001 compliant and has a resettable element. The range uses an IP67 weatherproof polycarbonate housing and is available in colours other than red.OperationThe address of each call point is set at the commissioning stage by means of a seven-segment DIL switch. A red alarm LED is provided on the call point. This LED is controlled independently of the call point by the control panel. This Manual Call Point helps reduce installation time as all the initial installation cabling is wired to a terminal block which fits neatly in the back of the Call Point. Once activated the XP95 IS Manual Call Point can be reset by inserting the test key into the bottom of the unit until the key clicks into position. Remove the test key and push the front cover up until it clicks homeKey FeaturesPlug and Play terminal connections for fast wiringContinuity link for wiring test before commissioningReports an alarm in under 0.2 secondsResettable element

GBP 183.65
1

Apollo Discovery amp XP95 Intelligent Manual Call Point SA5900-908APO

Apollo Discovery amp XP95 Intelligent Manual Call Point SA5900-908APO

Apollo Discovery XP95 Intelligent Manual Call Point SA5900-908APOThe Intelligent Manual Call Point has been designed to operate on a loop of intelligent fire detection devices. An alarm is initiated by pressing the resettable element. The manual call point signals to the Control and Indicating Equipment using an interrupt feature within the Apollo Digital Protocol.An alarm status is indicated through the rotation of the resettable element displaying yellow and black indication bars and a solid red LED. The manual call point can be easily reset from the front using the supplied reset key.Key FeaturesResettable operating elementEasy access front reset mechanismE-Z fit connector system for installationErgonomic reset keyEN 54-11 EN 54-17 Certified Red version only170 viewable LEDContinuity link for cable insulation testingSuitable for semi flush or surface mountingOperating PrinciplesThe address of each call point is set at the commissioning stage by means of a DIL switch.A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and CoreProtocol configurable.Once activated the Intelligent Manual Call Point can be reset by inserting the reset key into the front facing LED turning clockwise until a positive click and reset occurs.The Intelligent Manual Call Point incorporates a short circuit isolator which will ensure its operation in the event of a short circuit fault on the loop. Isolator operation is indicated by a solid yellow LED.This manual call point helps reduce installation time as all the initial installation cabling is wired to a removable terminal block which fits neatly in the back of the manual call point.Protocol CompatibilityThe Intelligent Manual Call Point will operate with compatible Apollo control equipment using the digital XP95 Discovery and CoreProtocols.Electrical ConsiderationThe Intelligent Manual Call Point is loop powered and operates at 17-35V DC for all variants.

GBP 35.77
1

Apollo Orbis Optical Smoke Detector - ORB-OP-12001-APO

Apollo Orbis Optical Smoke Detector - ORB-OP-12001-APO

Apollo Orbis Optical Smoke Detector - ORB-OP-12001-APOThe Orbis Optical Smoke Detector operates on the well-established light scatter principle. The sensing technology used is radically different from previous optical detectors and significantly reduces false alarms. Orbis operates on the well-established light scatter principle. The remarkable optical design of the Orbis optical smoke detector allows it to respond to a wide spectrum of fires. The sensing chamber of the Orbis optical smoke detector contains an optical sensor which measures back-scattered light as well as the more usual forward-scattered light.Sensitivity to black smoke is greatly improved. The detector is calibrated so that Orbis is highly reliable in detecting fires but is much less likely to generate false alarms than earlier smoke detectors. The stability of the detectorhigh reliability low false alarm rateis further increased by the use of algorithms to decide when the detector should change to the alarm state. This removes the likelihood of a detector producing an alarm as a result of smoke from smoking materials or from another non-fire source.Brand InformationOrbis is a range of conventional detectors which has been developed and tested to create advantages for fire engineers and installers as well as owners and users of buildings. Orbis is a range with modern styling and a mounting base that saves installation time. It is electrically compatible with Apollo Series 65 and previous ranges of conventional detector.Orbis is a demonstration of Apollos commitment to the market for high quality conventional detectors for use in small to medium size installations. In developing this range Apollo has put ease of installation and reliability in daily operation at the forefront of considerations. The attractive and compact design means that Orbis will blend in well with all architectural styles.Key FeaturesResponds well to slow burning smouldering firesTransient rejection algorithms reduce false alarmsAutomatic drift compensation with DirtAlert a yellow flashing LED to easily identify dirty detectorsRed flashing LED at StartUp confirms the device is operatingSensAlert yellow flashing LED indicates faulty operationFasTest takes just four seconds to test and confirm detectors are functioning correctlyDustDefy system prevents dust ingress while maintaining airflow

GBP 17.24
1

Apollo Intelligent Auto-Aligning Beam Detector SA7100-100APO

Apollo Intelligent Auto-Aligning Beam Detector SA7100-100APO

Apollo Intelligent Auto-Aligning Beam Detector SA7100-100APOThe Intelligent Auto-Aligning Beam Detector combines a transmitterreceiver in the same detector head with an automatic alignment motor. This combination with integrated addressability allows for quick and simple installation. The Intelligent Auto-Aligning Beam Detector automatically compensates for environmental effects on the beam signal keeping the unit in the best possible working order. This is achieved through the combination of software automatic gain control and motorised realignment of the beam.OperationThe Intelligent Auto-Aligning Beam Detector is a compact detector for detecting smoke in large open areas such as warehouses theatres churches and sports centres. It comprises a ground level loop-powered controller a detector head with an operating range of 8m-50m and a single prism. The operating range of each detector head can be increased up to 100m by using the Extension Kit which comprises of three additional prisms.An additional detector head can be connected to the controller. Each head has a loop address. It also has a built in 20T negative bi-directional short circuit isolator and it is compatible with control panels using CoreProtocol Discovery and XP95 protocol. A built-in laser provides rapid initial alignment and thereafter the detector head will continuously automatically align and compensate for any building movement.The status of each detector can be monitored through the controller which is sited at ground level. The detector head operates both as a transmitter and a receiver. A well-defined IR beam is projected to a prism mounted on the opposite wall which is reflected back to the receiver. In the event of smoke partially obscuring the light an imbalance between the transmitted and received light will occur. The detector will then transmit an alarm value to the control panel.The detector is factory set to a beam obscuration of 35 which is the best setting for most factories and warehouses. The setting can be changed to 25 for offices and clean areas such as theatres or to 50 for hostile areas such as mills or foundries. The detector reports a pre-alarm analogue value 48 at approximately 75 of the alarm threshold. The detector compensates automatically for gradual contamination of the lenses in order to avoid false alarms. The detector is non-latching and resets 30 seconds after an alarm event ceases and in 3 seconds after the removal of a fault.Key FeaturesLoop Powered and compatible with XP95 Discovery and CoreProtocolIncorporates a bi directional short-circuit isolatorAutomatic drift compensationAutomatic resetGround level ControllerAutomatic alignment compensation for building movementLaser assisted alignment for quick installationAllows for 2 detector heads per controllerUp to 100m rangePre-alarm thresholdEN 54-12 and EN 54-17 certified

GBP 599.51
1