74 results (0,13103 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Apollo SA6700-100APO Intelligent Twin Switch Monitor

Apollo Marine Mini Switch Monitor 55000-775MAR

Apollo SA4700-100APO Intelligent Switch Monitor

Apollo SA4700-300APO Intelligent DIN-Rail Switch Monitor

Apollo Marine DIN-Rail Switch Monitor Plus 55000-772MAR

Apollo XP95 Mini Switch Monitor - 55000-760APO

Apollo Dual Switch Manual Call Point SA5900-011APO

Apollo Integrated Base Sounder - Slow Whoop with Isolator 45681-290APO

Apollo 45681-300APO Integrated Base Sounder - DIN-Tone with Isolator

Apollo 45681-300APO Integrated Base Sounder - DIN-Tone with Isolator

Apollo 45681-300APO Integrated Base Sounder - DIN-Tone with IsolatorThe Integrated Base Sounder comprises of a base sounder with integral mounting base and is for use with Discovery or XP95 ranges. It is designed for indoor use.Electrical DescriptionThe integrated base sounder is line powered and needs no external power supply. It operates at 1728V DC and is polarity-sensitive.Mechanical ConstructionThe integrated base sounder is moulded in polycarbonate and has stainless steel contacts that accept solid or stranded cables of up to 2.5mm.Device AddressingADDRESSING The integrated base sounder responds to its own individual address set with a DIL switch. It also responds both to a group address set by means of a 4-segment DIL switch and to a pulsed-mode synchronisation address which is embedded in the unit. GROUP ADDRESSING It may be desirable in alarm conditions to switch more than one integrated base sounder simultaneously. To enable this sounders may be controlled as a group and given a group address which is common to all sounders in the group. When a device recognises its group address it will process the forward command bits but it will not return any data to the control panel on that ad dress. If it is required to confirm the status of the outputs of devices under group address control it is necessary to interrogate all devices in the group at their individual addresses.CommunicationXP95 Discovery and CoreProtocol compatibleKey FeaturesTwo tonesTwo volume ranges 55-75dBA and 75-91dBAIndividual and group addressingUnique acoustic self-testBuilt-in isolator

GBP 37.24
1

Apollo Discovery White Open-Area Voice Sounder - 58000-020APO

Apollo Intelligent Green Manual Call Point - SA5900-906APO

Apollo Intelligent Green Manual Call Point - SA5900-906APO

Apollo Intelligent Green Manual Call Point - SA5900-906APOThe Intelligent Manual Call Point has been designed for indoor applications and are available in a variety of colours for different applications such as initiating a hazard rather than a fire alarm. The Intelligent Manual Call Point can be used on XP95 Discovery and CoreProtocol systems.A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and CoreProtocol configurable. Once activated the Intelligent Manual Call Point can be reset by inserting the reset key into the front facing LED turning clockwise until a positive click and reset occurs.OperationThe address of each call point is set at the commissioning stage by means of a DIL switch. A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and CoreProtocol configurable. Once activated the Intelligent Manual Call Point can be reset by inserting the reset key into the front facing LED turning clockwise until a positive click and reset occurs.Key FeaturesResettable operating elementEasy access front reset mechanismE-Z fit connector system for installationErgonomic reset key170 viewableLED Continuity link for cable insulation testingSuitable for semi flush or surface mounting

GBP 46.91
1

Apollo Intelligent Blue Manual Call Point - SA5900-905APO

Apollo Intelligent Blue Manual Call Point - SA5900-905APO

Apollo Intelligent Blue Manual Call Point - SA5900-905APOThe Intelligent Manual Call Point has been designed for indoor applications and are available in a variety of colours for different applications such as initiating a hazard rather than a fire alarm. The Intelligent Manual Call Point can be used on XP95 Discovery and CoreProtocol systems.A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and CoreProtocol configurable. Once activated the Intelligent Manual Call Point can be reset by inserting the reset key into the front facing LED turning clockwise until a positive click and reset occurs.OperationThe address of each call point is set at the commissioning stage by means of a DIL switch. A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and CoreProtocol configurable. Once activated the Intelligent Manual Call Point can be reset by inserting the reset key into the front facing LED turning clockwise until a positive click and reset occurs.Key FeaturesResettable operating elementEasy access front reset mechanismE-Z fit connector system for installationErgonomic reset key170 viewableLED Continuity link for cable insulation testingSuitable for semi flush or surface mounting

GBP 46.91
1

Apollo Intelligent White Manual Call Point - SA5900-903APO

Apollo Intelligent White Manual Call Point - SA5900-903APO

Apollo Intelligent White Manual Call Point - SA5900-903APOThe Intelligent Manual Call Point has been designed for indoor applications and are available in a variety of colours for different applications such as initiating a hazard rather than a fire alarm. The Intelligent Manual Call Point can be used on XP95 Discovery and CoreProtocol systems.A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and CoreProtocol configurable. Once activated the Intelligent Manual Call Point can be reset by inserting the reset key into the front facing LED turning clockwise until a positive click and reset occurs.OperationThe address of each call point is set at the commissioning stage by means of a DIL switch. A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and CoreProtocol configurable. Once activated the Intelligent Manual Call Point can be reset by inserting the reset key into the front facing LED turning clockwise until a positive click and reset occurs.Key FeaturesResettable operating elementEasy access front reset mechanismE-Z fit connector system for installationErgonomic reset key170 viewableLED Continuity link for cable insulation testingSuitable for semi flush or surface mounting

GBP 46.91
1

Apollo Intelligent Orange Manual Call Point - SA5900-907APO

Apollo Intelligent Orange Manual Call Point - SA5900-907APO

Apollo Intelligent Orange Manual Call Point - SA5900-907APOThe Intelligent Manual Call Point has been designed for indoor applications and are available in a variety of colours for different applications such as initiating a hazard rather than a fire alarm. The Intelligent Manual Call Point can be used on XP95 Discovery and CoreProtocol systems.A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and CoreProtocol configurable. Once activated the Intelligent Manual Call Point can be reset by inserting the reset key into the front facing LED turning clockwise until a positive click and reset occurs.OperationThe address of each call point is set at the commissioning stage by means of a DIL switch. A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and CoreProtocol configurable. Once activated the Intelligent Manual Call Point can be reset by inserting the reset key into the front facing LED turning clockwise until a positive click and reset occurs.Key FeaturesResettable operating elementEasy access front reset mechanismE-Z fit connector system for installationErgonomic reset key170 viewableLED Continuity link for cable insulation testingSuitable for semi flush or surface mounting

GBP 47.57
1

Apollo Intelligent Yellow Manual Call Point - SA5900-904APO

Apollo Intelligent Yellow Manual Call Point - SA5900-904APO

Apollo Intelligent Yellow Manual Call Point - SA5900-904APOThe Intelligent Manual Call Point has been designed for indoor applications and are available in a variety of colours for different applications such as initiating a hazard rather than a fire alarm. The Intelligent Manual Call Point can be used on XP95 Discovery and CoreProtocol systems.A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and CoreProtocol configurable. Once activated the Intelligent Manual Call Point can be reset by inserting the reset key into the front facing LED turning clockwise until a positive click and reset occurs.OperationThe address of each call point is set at the commissioning stage by means of a DIL switch. A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and CoreProtocol configurable. Once activated the Intelligent Manual Call Point can be reset by inserting the reset key into the front facing LED turning clockwise until a positive click and reset occurs.Key FeaturesResettable operating elementEasy access front reset mechanismE-Z fit connector system for installationErgonomic reset key170 viewableLED Continuity link for cable insulation testingSuitable for semi flush or surface mounting

GBP 46.91
1

Apollo Series 65 Optical Smoke Detector with Flashing LED and Magnetic Test Switch 55000-315APO

Apollo Series 65 Optical Smoke Detector with Flashing LED and Magnetic Test Switch 55000-315APO

Apollo Series 65 Optical Smoke Detector with Flashing LED and Magnetic Test Switch 55000-315APOThe Series 65 Optical Smoke Detector incorporates a pulsing LED located within the housing of the detector. The external detector moulding is identical to that of the ionisation detector and has an indicator LED which is clear in quiescent state but produces a red light in alarm.OperationThe Series 65 Optical Smoke Detector has a moulded self-extinguishing white polycarbonate case with wind resistant smoke inlets. Nickel-plated stainless-steel wiper contacts connect the detector to the base. Inside the case a printed circuit board has the optical system mounted on one side and the signal processing electronics on the other. The sensing chamber is a black moulding configured as a labyrinth which prevents penetration of ambient light. The labyrinth has a fine gauze insect-resistant cover. The chamber houses an infrared light emitting diode LED and a photo-diode which has an integral visible-light filter as extra protection against ambient light. Every three seconds the LED emits a burst of collimated light modulated at 4kHz. In clear air light from the LED does not fall directly on the diode because the LED is positioned at an obtuse angle to the diode. When smoke enters the chamber a fraction of the collimated light is scattered onto the photo-diode. If the resulting signal from the photo-diode is above a pre-set threshold the LED emits two more bursts of light this time at two-second intervals. If light is scattered onto the photo-diode by both these pulses due to the presence of smoke the detector signals an alarm state by switching the alarm latch on increasing the current drawn from the supply from about 40A to a maximum of 75mA. This fall in the impedance of the detector is recognised by the control panel as an alarm signal. The alarm current also illuminates the detector integral LED. A remote indicator connected between the L1 IN terminal and the R terminal will have a voltage equal to the supply voltage less 1 volt across it and so will illuminate. To ensure correct operation of the detector the control panel must be arranged to supply a maximum of 33 Volts dc and a minimum of 9 Volts dc in normal operation. The supply may fall to 6 Volts dc in alarm conditions if a supply current of at least 10mA is available at this voltage. To ensure effective illumination of the integral LED and any remote indicator the supply to the detector should exceed 12 Volts. To restore the detector to quiescent condition it is necessary to expel any smoke and interrupt the electrical supply to the detector for a minimum of one second.Key FeaturesResponds well to slow-burning smouldering firesWell-suited to bedrooms and escape routesUnaffected by wind or atmospheric pressureFlashing LED and magnet operated test switch option

GBP 19.98
1

Apollo Discovery White Open-Area Voice Sounder Beacon - 58000-040APO

Apollo Waterproof Addressable Manual Call Point 58200-951APO

Apollo Discovery Marine Weatherproof Manual Call Point 58200-976MAR

Apollo Discovery Marine Weatherproof Manual Call Point 58200-976MAR

Apollo Discovery Marine Weatherproof Manual Call Point 58200-976MARThe Discovery Marine Manual Call Points has been designed for use in marine and offshore environments and are available in two versions for indoor and outdoor applications. Both versions are available with and without short circuit isolators.An alarm is initiated by pressing the resettable element. The Manual Call Point signals to the Control and Indicating Equipment using an interrupt feature within the Apollo Digital Protocol. An alarm status is indicated by a yellow and black bar in the lower section of the resettable element and a red LED. The Manual Call Point can be easily reset from the front using the supplied reset key.Discovery Marine analogue addressable fire detectors are suitable for larger vessels. The high specification range has been developed to meet the requirements of sophisticated systems. Discovery gives you total reassurance in installations where it is necessary to adapt detection to different operating environments and where protection against unwanted alarms is paramount.OperationThe address of each call point is set at the commissioning stage by means of a seven-segment DIL switch. On the indoor versions the address switch is accessible without removing the call point from the mounting surface. A red alarm LED is provided on the call point. This LED is controlled independently of the call point by the control panel.This Manual Call Point helps reduce installation time as all the initial installation cabling is wired to a terminal block which fits neatly in the back of the call point. Once activated the Discovery Marine Manual Call Point can be reset by inserting the reset key into the front facing LED turning clock wise until a positive click and reset occurs.Key FeaturesApproved for use in the marine environmentFive response modes for environmental adaptationDaynight switching for increased flexibilityDrift compensation for false alarm reductionUser programmability for dataXPERT card addressing for increased security

GBP 153.76
1

Apollo Loop-Powered Amber Visual Indicator - 55000-879APO

Apollo Loop-Powered Clear Visual Indicator 55000-878APO

Apollo Discovery Marine Sounder Visual Indicator Base - 45681-394MAR

Apollo Weatherproof Red Multi-Tone Open-Area Sounder Visual Indicator without Isolator 55000-296APO

Apollo Weatherproof Red Multi-Tone Open-Area Sounder Visual Indicator without Isolator 55000-296APO

Please note This product is currently on an extended leadtime and will be available from June 2024. Pleasecontact usfor further information.Apollo Weatherproof Red Multi-Tone Open-Area Sounder Visual Indicator without Isolator 55000-296APOThe Weatherproof Multi-Tone Open-Area Sounder Visual Indicator is designed for use in outdoor open areas and can be connected to any Discovery or XP95 system. The sounder visual indicator complements Apollos intelligent and integrated base sounders as well as the Multi-Tone Open-Area Sounder.The Multi-tone Open-Area Alarm Devices responds to their own individual address set with a DIL switch. They can also respond to a Group Address which allows multiple sounders to be controlled simultaneously. A group address may be any spare address between 112 and 126 and is selected by means of a 4 segment DIL switch.An Alarm Device under group address control must have an individual address between 1 and 111 otherwise a fault value of 4 is transmitted. Alarm Devices not using the group address facility may be addressed at any address 1126.The Weatherproof Multi-Tone Open-Area Sounder Visual Indicator is designed for use in outdoor open areas and can be connected to any Discovery or XP95 system. The sounder visual indicator complements Apollos intelligent and integrated base sounders as well as the Multi-Tone Open-Area Sounder.Key FeaturesChoice of tones on standard device Apollo Slow Whoop and DINIP66 ratedTwo Volume settings 92dBA and 100dBASynchronisation of alert and evacuate tonesIndividual and group addressing

GBP 174.34
1

Apollo Integrated Base Sounder without Isolator 45681-278APO

Apollo XP95 Beacon Base with Isolator - 45681-333APO

Apollo XP95 Beacon Base with Isolator - 45681-333APO

Apollo XP95 Beacon Base with Isolator - 45681-333APOThe Visual Indicator Base is a loop-powered visual indicator combined with a standard Intelligent Mounting Base. It is used to signal a fire alarm in enclosed areas. The visual indicator base can be used with either a detector fitted or with a cap as a stand-alone alarm device. The base is loop powered so needs no external power supply. It operates at 1728V DC and is polarity-sensitive.Device AddressingThe Base responds to its own individual address set with a DIL switch. It also responds to a group address set by means of a 4-segment DIL switch and to a synchronisation address which is embedded in the unit. Addresses 1 to 111 are used exclusively for individual addresses addresses 112 to 126 are used for group addressing while the synchronisation address to which all units respond is 0. Any Beacon Base on a loop may be freely assigned to a group. The address for any group must be chosen from the range 112126.Addresses 112126 may be used as individual addresses but only if the 4-segment DIL switch is not used ie group addressing is disabled. If the 4-segment DIL switch were set to any number other than the default 127 a pre-set analogue value of 4 would be transmitted to indicate a fault. The Base is normally polled by its individual address. It responds as described below. It is recommended that the synchronisation address 0 be sent by the control panel at regular intervals to align the internal clock of all sounders. The result is that the beacons are synchronised with each other when activated.Key FeaturesVisual indicator flash rate of once per secondSynchronisation of visual indicator flashIndividual and group addressingUnique visual indicator self-testLoop-poweredBuilt-in Isolator

GBP 35.83
1