353 results (0,13489 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Apollo Isolator XP95 and Discovery 55000-720APO

Apollo SA5100-810APO Soteria Tri-Sensor Detector Dual OpticalHeatCO

Apollo Universal Bracket for Beam Detector Heads and Prisms 29600-527

Apollo XPander Optical Smoke Detector and Mounting Base XPA-CB-12034-APO

Apollo XPander Sounder Beacon and A1R Heat Detector XPA-CB-14021-APO

Apollo XPander Sounder Beacon and A1R Heat Detector XPA-CB-14021-APO

Apollo XPander Sounder Beacon and A1R Heat DetectorXPA-CB-14021-APOXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves.The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface. The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.OperationXPander sounders can be wall or ceiling mounted and use a bi-directional monitored radio platform to communicate. They feature 32 selectable tones including the Apollo tone and a self test which causes a fault signal to be sent if the sounders fail to operate. The self-test feature is activated by a DIL Switch. Individual parts may be ordered separately.Key Featuresmodern stylingloop-powered interface operating on 868MHzwireless addresses seen by control panel as normal addressesradio base with wireless circuitry and battery compartmentchamber designed to inhibit dirt penetration and thus reduce false alarmsautomatic drift compensation with DirtAlert warningalgorithms for transient alarm rejectionFasTest reduces time taken to test detectorsremote test facility3-5 years battery life

GBP 372.43
1

Apollo XPander Sounder Beacon and CS Heat Detector XPA-CB-14022-APO

Apollo XPander Sounder Beacon and CS Heat Detector XPA-CB-14022-APO

Apollo XPander Sounder Beacon and CS Heat DetectorXPA-CB-14022-APOXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves.The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface. The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.OperationXPander sounders can be wall or ceiling mounted and use a bi-directional monitored radio platform to communicate. They feature 32 selectable tones including the Apollo tone and a self test which causes a fault signal to be sent if the sounders fail to operate. The self-test feature is activated by a DIL Switch. Individual parts may be ordered separately.Key Featuresmodern stylingloop-powered interface operating on 868MHzwireless addresses seen by control panel as normal addressesradio base with wireless circuitry and battery compartmentchamber designed to inhibit dirt penetration and thus reduce false alarmsautomatic drift compensation with DirtAlert warningalgorithms for transient alarm rejectionFasTest reduces time taken to test detectorsremote test facility3-5 years battery life

GBP 372.43
1

Apollo XPander Sounder Beacon and Optical Smoke Detector XPA-CB-14020-APO

Apollo XPander Sounder Beacon and Optical Smoke Detector XPA-CB-14020-APO

Apollo XPander Sounder Beacon and Optical Smoke DetectorXPA-CB-14020-APOXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. The interface communicates with the detection and alarm signalling devices by means of radio waves. The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface.The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.OperationXPander sounders can be wall or ceiling mounted and use a bi-directional monitored radio platform to communicate. They feature 32 selectable tones including the Apollo tone and a self test which causes a fault signal to be sent if the sounders fail to operate. The self-test feature is activated by a DIL Switch. Individual parts may be ordered separately.Key Featuresmodern stylingloop-powered interface operating on 868MHzwireless addresses seen by control panel as normal addressesradio base with wireless circuitry and battery compartmentchamber designed to inhibit dirt penetration and thus reduce false alarmsautomatic drift compensation with DirtAlert warningalgorithms for transient alarm rejectionFasTest reduces time taken to test detectors remote test facility3-5 years battery life

GBP 370.69
1

Apollo XPander Multisensor Detector and Mounting Base XPA-CB-13032-APO

Apollo XPander A1R Heat Detector and Mounting Base - XPA-CB-11170-APO

Apollo XPander A1R Heat Detector and Mounting Base - XPA-CB-11170-APO

Apollo XPander A1R Heat Detector and Mounting Base - XPA-CB-11170-APOThere are two heat detectors in the XPander range designed to suit a wide variety of operating conditions. A static heat detector CS responds only when a fixed temperature has been reached and a Rate-of-Rise Detector A1R which has a fixed upper limit but in addition measures the rate of increase in temperature.Brand InformationXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves. The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface.The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.Key Features WirelessCan be used in applications where smoke detectors are unsuitableIdeal for environments that are dirty or smoky under natural conditionsCS detectors are ideal for use in the environments with rapid temperature fluctuations such as boiler roomsBi-directional monitored radio platformFiveyear battery life using standard AA alkaline batteries

GBP 188.28
1

Apollo XPander CS Heat Detector and Mounting Base - XPA-CB-11171-APO

Apollo XPander CS Heat Detector and Mounting Base - XPA-CB-11171-APO

Apollo XPander CS Heat Detector and Mounting Base - XPA-CB-11171-APOThere are two heat detectors in the XPander range designed to suit a wide variety of operating conditions. A static heat detector CS responds only when a fixed temperature has been reached and a Rate-of-Rise Detector A1R which has a fixed upper limit but in addition measures the rate of increase in temperature.Brand InformationXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves. The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface.The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.Key Features WirelessCan be used in applications where smoke detectors are unsuitableIdeal for environments that are dirty or smoky under natural conditionsCS detectors are ideal for use in the environments with rapid temperature fluctuations such as boiler roomsBi-directional monitored radio platformFiveyear battery life using standard AA alkaline batteries

GBP 187.36
1

Apollo XPander Sounder Visual Indicator Clear and Optical Smoke Detector XPA-CB-14024-APO

Apollo XPander Sounder Visual Indicator Clear and Optical Smoke Detector XPA-CB-14024-APO

Apollo XPander Sounder Visual Indicator Clear and Optical Smoke Detector XPA-CB-14024-APOThe XPander Sounder and Sounder Base is wireless and designed to be used with XPander detectors and manual call points.OperationXPander sounders can be wall or ceiling mounted and use a bi-directional monitored radio platform to communicate. They feature 32 selectable tones including the Apollo tone and a self-test which causes a fault signal to be sent if the sounders fail to operate. The self-test feature is activated by a DIL Switch.Brand InformationXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves.The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface. The detectors incorporate drift compensation and report any compensation limit occurring.The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.Key FeaturesWirelessBi-directional monitored radio platformChoice of 32 selectable tonesAudible self-test availableOutput is between 92 and 106dbA at 1m dependent on tone setting

GBP 372.43
1

Apollo Series 65 Optical Smoke Detector with Flashing LED and Magnetic Test Switch 55000-315APO

Apollo Series 65 Optical Smoke Detector with Flashing LED and Magnetic Test Switch 55000-315APO

Apollo Series 65 Optical Smoke Detector with Flashing LED and Magnetic Test Switch 55000-315APOThe Series 65 Optical Smoke Detector incorporates a pulsing LED located within the housing of the detector. The external detector moulding is identical to that of the ionisation detector and has an indicator LED which is clear in quiescent state but produces a red light in alarm.OperationThe Series 65 Optical Smoke Detector has a moulded self-extinguishing white polycarbonate case with wind resistant smoke inlets. Nickel-plated stainless-steel wiper contacts connect the detector to the base. Inside the case a printed circuit board has the optical system mounted on one side and the signal processing electronics on the other. The sensing chamber is a black moulding configured as a labyrinth which prevents penetration of ambient light. The labyrinth has a fine gauze insect-resistant cover. The chamber houses an infrared light emitting diode LED and a photo-diode which has an integral visible-light filter as extra protection against ambient light. Every three seconds the LED emits a burst of collimated light modulated at 4kHz. In clear air light from the LED does not fall directly on the diode because the LED is positioned at an obtuse angle to the diode. When smoke enters the chamber a fraction of the collimated light is scattered onto the photo-diode. If the resulting signal from the photo-diode is above a pre-set threshold the LED emits two more bursts of light this time at two-second intervals. If light is scattered onto the photo-diode by both these pulses due to the presence of smoke the detector signals an alarm state by switching the alarm latch on increasing the current drawn from the supply from about 40A to a maximum of 75mA. This fall in the impedance of the detector is recognised by the control panel as an alarm signal. The alarm current also illuminates the detector integral LED. A remote indicator connected between the L1 IN terminal and the R terminal will have a voltage equal to the supply voltage less 1 volt across it and so will illuminate. To ensure correct operation of the detector the control panel must be arranged to supply a maximum of 33 Volts dc and a minimum of 9 Volts dc in normal operation. The supply may fall to 6 Volts dc in alarm conditions if a supply current of at least 10mA is available at this voltage. To ensure effective illumination of the integral LED and any remote indicator the supply to the detector should exceed 12 Volts. To restore the detector to quiescent condition it is necessary to expel any smoke and interrupt the electrical supply to the detector for a minimum of one second.Key FeaturesResponds well to slow-burning smouldering firesWell-suited to bedrooms and escape routesUnaffected by wind or atmospheric pressureFlashing LED and magnet operated test switch option

GBP 19.98
1

Apollo Orbis TimeSaver Base - ORB-MB-00001-APO

Apollo Indoor Intrinsically Safe Manual Call Point 470 ohm - 55100-031APO

Apollo SA4700-302APO Intelligent DIN-Rail Input Output Unit

Apollo Orbis Marine Optical Smoke Detector with Flashing LED ORB-OP-42003-MAR

Apollo Orbis TimeSaver Sav-Wire Base ORB-SW-10005-APO

Apollo SA4700-300APO Intelligent DIN-Rail Switch Monitor

Apollo Orbis Marine Optical Smoke Detector ORB-OP-42001-MAR

Apollo SA4700-103APO Intelligent Mains Switching Input Output Unit

Apollo AlarmSense Sounder Beacon Base 45681-509APO

Apollo Orbis TimeSaver Deep Base - ORB-MB-00019-APO

Apollo AlarmSense Base 45681-244APO

Apollo SA4700-102APO Intelligent Input Output Unit

Apollo AlarmSense Sounder Base 45681-510APO

Apollo AlarmSense Sounder Base 45681-510APO

Apollo AlarmSense Sounder Base 45681-510APOThe AlarmSense Sounder Base can only be used with AlarmSense systems. It is fitted with electronic circuitry to monitor the presence of detectors and signals any unauthorised removal of detector heads. It is supplied with a high or low volume setting and red or white capsare available for stand-alone installation.Brand InformationAlarmSense is a range of conventional fire detection and alarm products designed to be connected to the same pair of supply wires making installation quicker and less expensive.AlarmSense has been developed to make the design and installation of a fire detection and alarm system easier and more economic for small to medium-sized buildings. The range also allows an existing system to be extended or modified if necessary. This flexibility makes AlarmSense an excellent choice for use in HMOs House in Multiple Occupation.As you would expect from Apollo AlarmSense incorporates features that help reduce false alarms and patented technology to ensure the integrity of a system. The range also includes products such as beacons to help meet the requirements of the Disability Discrimination Act DDA.Brand FeaturesFlexibleReliableCost-effectiveCompliant with BS 5839Easy to installEasy to extendKey FeaturesAlarmSense prioritynon priority signal recognitionDetects the removal of a detector head and reports a faultContinues to work during unauthorised removal of detectorsQuick and simple installationProvides audible signal and detection at one pointHigh and low volume ranges

GBP 22.99
1