194 results (0,15414 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Apollo Marine Intelligent Base Mounted IR3 Flame Detector 55000-029MAR

Apollo Marine Intelligent Base Mounted IR3 Flame Detector 55000-029MAR

Apollo Marine Intelligent Base Mounted IR3 Flame Detector 55000-029MARThe Intelligent Base Mounted IR3 Flame Detector is designed to protect all indoor areas even in dirty or smoky conditions where open flaming fires may be expected. The detector has three IR sensors that respond to different IR wavelengths in order to discriminate between flames and spurious sources of radiation.ApplicationThe triple IR flame detector is also fast reacting but is also tolerant of fumes vapours steam dust and mist while being unaffected by the phenomena listed above. It may however be affected by modulated IR radiation. Triple IR flame detectors are used in waste handling colour printing and paper manufacturing.OperationThe detector is sensitive to low-frequency flickering infra-red radiation emitted by flames during combustion. Since it responds to flickering radiation the detector can operate even if the lens is contaminated by a layer of oil dust water-vapour or ice. The detector is set to respond to low-frequency radiation at 1-15Hz 0.75-2.7ym in order to detect all flickering flames including those invisible to the naked eye e.g. those emitted by hydrogen fires.The detector has three IR sensors that respond to different IR wavelengths in order to discriminate between flames and spurious sources of radiation. False alarms due to factors such as flickering sunlight are avoided by a combination of filters and signal processing techniques.Key FeaturesResponds to stationary flames with no flickerSensitive to low-frequency flickering IR radiation emitted by flames during combustionCompact flame detector which fits into Discovery Marine mounting basesLoop-poweredFalse alarms due to factors such as flickering sunlight are avoided by a combination of filters and signal processing techniques

GBP 1177.80
1

Apollo Discovery White Open-Area Voice Sounder Beacon - 58000-040APO

Apollo Discovery White Open-Area Voice Sounder - 58000-020APO

Apollo Marine Intelligent Base Mounted UV Flame Detector 55000-027MAR

Apollo Marine Intelligent Base Mounted UV Flame Detector 55000-027MAR

Apollo Marine Intelligent Base Mounted UV Flame Detector 55000-027MARThe Marine Intelligent Base Mounted UV Flame Detector is designed to protect enclosed indoor areas where open fires may be expected. The detector has a fast-acting response to flames up to 25m away and is equipped with a single UV sensor with a narrow spectral response in order to discriminate between flames and most spurious sources of radiation.ApplicationUV flame detectors are used when detection is required to be unaffected by convection currents draughts or wind. These include engine rooms in ships factories affected by draughts or wind and warehouses. They are fast reacting and respond to a flame more than 25m away. The UV flame detector is affected by arc welding electrical sparks lightning nuclear radiation and UV light sources. For applications where these phenomena are present a UV flame detector should not be used.OperationThe detector is sensitive to ultraviolet radiation emitted by flames during combustion. Since it requires only UV radiation the detector responds even to stationary flames with no flicker like cigarette lighters and blue gas flames.The detector is set to respond to ultraviolet radiation 185260nm emitted by almost all flames including those invisible to the naked eye e.g. hydrogen fires. The detector has a single UV sensor with a narrow spectral response in order to discriminate between flames and most spurious sources of radiation and is designed for internal fully enclosed areas. Caution The detector will also detect electrical discharges from lightning or arc welding.Key FeaturesResponds to stationary flames with no flickerSensitive to UV radiation emitted by flames during combustionCompact flame detector which fits into Discovery Marine baseLoop-powered

GBP 982.80
1

Apollo Marine Intelligent Base Mounted UVIR2 Flame Detector 55000-028MAR

Apollo Marine Intelligent Base Mounted UVIR2 Flame Detector 55000-028MAR

Apollo Marine Intelligent Base Mounted UVIR2 Flame Detector 55000-028MARThe Marine Intelligent Base Mounted UV Dual IR Flame Detector is designed to protect open indoor areas where open flaming fires may be expected. The detector has a UV and dual IR sensors responding to different wavelengths in order to discriminate between flames and spurious sources of radiation. They are used in aircraft hangers generator rooms diesel and gas turbines and paint works.OperationThe detector is sensitive to ultraviolet and low-frequency flickering infra-red radiation emitted by flames during combustion. Since it requires both UV and IR radiation the detector can operate in applications where a basic single UV or single IR detector would be inappropriate. The detector is set to respond to ultraviolet 185 - 260nm and low-frequency flickering infra-red 0.75 - 2.7ym radiation at 1 - 15Hz in order to detect all flickering flames including those invisible to the naked eye e.g. those emitted by hydrogen fires.The detector has one UV and two IR sensors responding to different wavelengths in order to discriminate between flames and spurious sources of radiation. False alarms due to electrical discharges from lightning or arc welding and flickering sunlight are minimised by combining the UVIR signals.Key FeaturesResponds to stationary flames with no flickerSensitive to low-frequency flickering IR radiation emitted by flames during combustion.Compact flame detector which fits into Discovery Marine basesLoop-poweredFalse alarms due to factors such as flickering sunlight are avoided by a combination of filters and signal processing techniques

GBP 1177.80
1

Apollo Waterproof Addressable Manual Call Point 58200-951APO

Apollo Intelligent White Manual Call Point - SA5900-903APO

Apollo Intelligent White Manual Call Point - SA5900-903APO

Apollo Intelligent White Manual Call Point - SA5900-903APOThe Intelligent Manual Call Point has been designed for indoor applications and are available in a variety of colours for different applications such as initiating a hazard rather than a fire alarm. The Intelligent Manual Call Point can be used on XP95 Discovery and CoreProtocol systems.A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and CoreProtocol configurable. Once activated the Intelligent Manual Call Point can be reset by inserting the reset key into the front facing LED turning clockwise until a positive click and reset occurs.OperationThe address of each call point is set at the commissioning stage by means of a DIL switch. A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and CoreProtocol configurable. Once activated the Intelligent Manual Call Point can be reset by inserting the reset key into the front facing LED turning clockwise until a positive click and reset occurs.Key FeaturesResettable operating elementEasy access front reset mechanismE-Z fit connector system for installationErgonomic reset key170 viewableLED Continuity link for cable insulation testingSuitable for semi flush or surface mounting

GBP 46.91
1

Apollo SA5900-928MAR Intelligent Marine Manual Call Point

Apollo SA5900-928MAR Intelligent Marine Manual Call Point

Apollo SA5900-928MAR Intelligent Marine Manual Call PointThe Intelligent Marine Manual Call Point MCP has been designed to operate on a loop of intelligent fire detection devices. An alarm is initiated by pressing the resettable element. The MCP signals to the Fire Control Panel using an interrupt feature within the Apollo Digital Communication Protocol. An alarm status is indicated through the rotation of the resettable element displaying yellow and black indication bars and a solid red LED. The MCP can be easily reset from the front using the supplied reset key. The Intelligent Marine MCP is intended for indoor marine and offshore applications and has a built-in short circuit isolator.OperationThe address of each call point is set at the commissioning stage by means of a DIL switch. A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and CoreProtocol configurable. Once activated the Intelligent Marine Manual Call Point SIL Approved can be reset by inserting the reset key into the front facing LED turning clockwise until a positive click and reset occurs.The Intelligent Marine Manual Call Point incorporates a short circuit isolator which will ensure its operation in the event of a short circuit fault on the loop. Isolator operation is indicated by a solid yellow LED.Key FeaturesResettable element for testingEasy access front reset mechanismA unique ergonomically designedKey for resetting and front cover removal

GBP 53.21
1

Apollo Intelligent Green Manual Call Point - SA5900-906APO

Apollo Intelligent Green Manual Call Point - SA5900-906APO

Apollo Intelligent Green Manual Call Point - SA5900-906APOThe Intelligent Manual Call Point has been designed for indoor applications and are available in a variety of colours for different applications such as initiating a hazard rather than a fire alarm. The Intelligent Manual Call Point can be used on XP95 Discovery and CoreProtocol systems.A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and CoreProtocol configurable. Once activated the Intelligent Manual Call Point can be reset by inserting the reset key into the front facing LED turning clockwise until a positive click and reset occurs.OperationThe address of each call point is set at the commissioning stage by means of a DIL switch. A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and CoreProtocol configurable. Once activated the Intelligent Manual Call Point can be reset by inserting the reset key into the front facing LED turning clockwise until a positive click and reset occurs.Key FeaturesResettable operating elementEasy access front reset mechanismE-Z fit connector system for installationErgonomic reset key170 viewableLED Continuity link for cable insulation testingSuitable for semi flush or surface mounting

GBP 46.91
1

Apollo Intelligent Blue Manual Call Point - SA5900-905APO

Apollo Intelligent Blue Manual Call Point - SA5900-905APO

Apollo Intelligent Blue Manual Call Point - SA5900-905APOThe Intelligent Manual Call Point has been designed for indoor applications and are available in a variety of colours for different applications such as initiating a hazard rather than a fire alarm. The Intelligent Manual Call Point can be used on XP95 Discovery and CoreProtocol systems.A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and CoreProtocol configurable. Once activated the Intelligent Manual Call Point can be reset by inserting the reset key into the front facing LED turning clockwise until a positive click and reset occurs.OperationThe address of each call point is set at the commissioning stage by means of a DIL switch. A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and CoreProtocol configurable. Once activated the Intelligent Manual Call Point can be reset by inserting the reset key into the front facing LED turning clockwise until a positive click and reset occurs.Key FeaturesResettable operating elementEasy access front reset mechanismE-Z fit connector system for installationErgonomic reset key170 viewableLED Continuity link for cable insulation testingSuitable for semi flush or surface mounting

GBP 46.91
1

Apollo Intelligent Orange Manual Call Point - SA5900-907APO

Apollo Intelligent Orange Manual Call Point - SA5900-907APO

Apollo Intelligent Orange Manual Call Point - SA5900-907APOThe Intelligent Manual Call Point has been designed for indoor applications and are available in a variety of colours for different applications such as initiating a hazard rather than a fire alarm. The Intelligent Manual Call Point can be used on XP95 Discovery and CoreProtocol systems.A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and CoreProtocol configurable. Once activated the Intelligent Manual Call Point can be reset by inserting the reset key into the front facing LED turning clockwise until a positive click and reset occurs.OperationThe address of each call point is set at the commissioning stage by means of a DIL switch. A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and CoreProtocol configurable. Once activated the Intelligent Manual Call Point can be reset by inserting the reset key into the front facing LED turning clockwise until a positive click and reset occurs.Key FeaturesResettable operating elementEasy access front reset mechanismE-Z fit connector system for installationErgonomic reset key170 viewableLED Continuity link for cable insulation testingSuitable for semi flush or surface mounting

GBP 47.57
1

Apollo Intelligent Yellow Manual Call Point - SA5900-904APO

Apollo Intelligent Yellow Manual Call Point - SA5900-904APO

Apollo Intelligent Yellow Manual Call Point - SA5900-904APOThe Intelligent Manual Call Point has been designed for indoor applications and are available in a variety of colours for different applications such as initiating a hazard rather than a fire alarm. The Intelligent Manual Call Point can be used on XP95 Discovery and CoreProtocol systems.A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and CoreProtocol configurable. Once activated the Intelligent Manual Call Point can be reset by inserting the reset key into the front facing LED turning clockwise until a positive click and reset occurs.OperationThe address of each call point is set at the commissioning stage by means of a DIL switch. A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and CoreProtocol configurable. Once activated the Intelligent Manual Call Point can be reset by inserting the reset key into the front facing LED turning clockwise until a positive click and reset occurs.Key FeaturesResettable operating elementEasy access front reset mechanismE-Z fit connector system for installationErgonomic reset key170 viewableLED Continuity link for cable insulation testingSuitable for semi flush or surface mounting

GBP 46.91
1

Apollo Conventional UV Dual IR Flame Detector 55000-064APO

Apollo Discovery Marine Sounder Visual Indicator Base - 45681-394MAR

Apollo Discovery Marine Manual Call Point 58100-970MAR

Apollo Discovery Marine Weatherproof Manual Call Point 58200-976MAR

Apollo Discovery Marine Weatherproof Manual Call Point 58200-976MAR

Apollo Discovery Marine Weatherproof Manual Call Point 58200-976MARThe Discovery Marine Manual Call Points has been designed for use in marine and offshore environments and are available in two versions for indoor and outdoor applications. Both versions are available with and without short circuit isolators.An alarm is initiated by pressing the resettable element. The Manual Call Point signals to the Control and Indicating Equipment using an interrupt feature within the Apollo Digital Protocol. An alarm status is indicated by a yellow and black bar in the lower section of the resettable element and a red LED. The Manual Call Point can be easily reset from the front using the supplied reset key.Discovery Marine analogue addressable fire detectors are suitable for larger vessels. The high specification range has been developed to meet the requirements of sophisticated systems. Discovery gives you total reassurance in installations where it is necessary to adapt detection to different operating environments and where protection against unwanted alarms is paramount.OperationThe address of each call point is set at the commissioning stage by means of a seven-segment DIL switch. On the indoor versions the address switch is accessible without removing the call point from the mounting surface. A red alarm LED is provided on the call point. This LED is controlled independently of the call point by the control panel.This Manual Call Point helps reduce installation time as all the initial installation cabling is wired to a terminal block which fits neatly in the back of the call point. Once activated the Discovery Marine Manual Call Point can be reset by inserting the reset key into the front facing LED turning clock wise until a positive click and reset occurs.Key FeaturesApproved for use in the marine environmentFive response modes for environmental adaptationDaynight switching for increased flexibilityDrift compensation for false alarm reductionUser programmability for dataXPERT card addressing for increased security

GBP 153.76
1

Apollo 58100-927APO Discovery Manual Call Point Yellow

Apollo 58100-927APO Discovery Manual Call Point Yellow

Apollo 58100-927APO Discovery Manual Call Point YellowA seven-segment DIL switch enables addressing of each call point at commissioning stage. When operated the manual call point interrupts the polling cycle for a fast response. Bi-coloured LEDs indicate isolate and normal conditions.The Apollo Discovery Manual Call Point has been designed to operate on a loop of intelligent fire detection devices. An alarm is initiated by pressing the resettable element. The manual call point signals to the control and indicating equipment using an interrupt feature within the Apollo digital communication protocol.An alarm status is indicated by a yellow and black bar in the lower section of the resettable element and a red LED. The manual call point can be easily reset from the front using the supplied reset key. It is available in two versions with and without isolator. The manual call point is intended for indoor applications.A red alarm LED is provided on the manual call point. This LED is controlled independently of the manual call point by the fire control panel.Once activated the manual call point can be reset by inserting the reset key into front facing LED turning clockwise until a positive click and reset occurs. An additional pack of 10 reset keys can be purchased Part Number 44251-176. The isolated version of the manual call point incorporates a short circuit isolator which will ensure its operation in the event of a short circuit fault on the loop. Isolator operation is indicated by a yellow LED. For further details of the isolator refer to datasheet PP2090 available on request.This manual call point helps reduce installation time as all the initial installation cabling is wired to a terminal block which fits neatly in the back of the call point.

GBP 70.79
1

Apollo 58100-910APO Discovery Manual Call Point Red

Apollo 58100-910APO Discovery Manual Call Point Red

Apollo 58100-910APO Discovery Manual Call Point RedA seven-segment DIL switch enables addressing of each call point at commissioning stage. When operated the manual call point interrupts the polling cycle for a fast response. Bi-coloured LEDs indicate isolate and normal conditions.The Apollo Discovery Manual Call Point has been designed to operate on a loop of intelligent fire detection devices. An alarm is initiated by pressing the resettable element. The manual call point signals to the control and indicating equipment using an interrupt feature within the Apollo digital communication protocol.An alarm status is indicated by a yellow and black bar in the lower section of the resettable element and a red LED. The manual call point can be easily reset from the front using the supplied reset key. It is available in two versions with and without isolator. The manual call point is intended for indoor applications.A red alarm LED is provided on the manual call point. This LED is controlled independently of the manual call point by the fire control panel.Once activated the manual call point can be reset by inserting the reset key into front facing LED turning clockwise until a positive click and reset occurs. An additional pack of 10 reset keys can be purchased Part Number 44251-176. The isolated version of the manual call point incorporates a short circuit isolator which will ensure its operation in the event of a short circuit fault on the loop. Isolator operation is indicated by a yellow LED. For further details of the isolator refer to datasheet PP2090 available on request.This manual call point helps reduce installation time as all the initial installation cabling is wired to a terminal block which fits neatly in the back of the call point.

GBP 57.14
1

Apollo XP95 Intelligent Heater Base 45681-219APO

Apollo Intelligent Base Mounted Triple IR Flame Detector 55000-024APO

Apollo Discovery amp XP95 Intelligent Manual Call Point SA5900-908APO

Apollo Discovery amp XP95 Intelligent Manual Call Point SA5900-908APO

Apollo Discovery XP95 Intelligent Manual Call Point SA5900-908APOThe Intelligent Manual Call Point has been designed to operate on a loop of intelligent fire detection devices. An alarm is initiated by pressing the resettable element. The manual call point signals to the Control and Indicating Equipment using an interrupt feature within the Apollo Digital Protocol.An alarm status is indicated through the rotation of the resettable element displaying yellow and black indication bars and a solid red LED. The manual call point can be easily reset from the front using the supplied reset key.Key FeaturesResettable operating elementEasy access front reset mechanismE-Z fit connector system for installationErgonomic reset keyEN 54-11 EN 54-17 Certified Red version only170 viewable LEDContinuity link for cable insulation testingSuitable for semi flush or surface mountingOperating PrinciplesThe address of each call point is set at the commissioning stage by means of a DIL switch.A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and CoreProtocol configurable.Once activated the Intelligent Manual Call Point can be reset by inserting the reset key into the front facing LED turning clockwise until a positive click and reset occurs.The Intelligent Manual Call Point incorporates a short circuit isolator which will ensure its operation in the event of a short circuit fault on the loop. Isolator operation is indicated by a solid yellow LED.This manual call point helps reduce installation time as all the initial installation cabling is wired to a removable terminal block which fits neatly in the back of the manual call point.Protocol CompatibilityThe Intelligent Manual Call Point will operate with compatible Apollo control equipment using the digital XP95 Discovery and CoreProtocols.Electrical ConsiderationThe Intelligent Manual Call Point is loop powered and operates at 17-35V DC for all variants.

GBP 35.77
1

Apollo Series 65 Base Mounted UV Flame Detector - 55000-025APO

Apollo Marine Series 65 Mounted UV Flame Detector 55000-026MAR

Apollo Discovery Weatherproof Yellow Manual Call Point with Isolator 58100-953APO

Apollo XP95 Manual Call Point with Isolator - 55100-908APO

Apollo XP95 Manual Call Point with Isolator - 55100-908APO

Apollo XP95 Manual Call Point with Isolator - 55100-908APOThe XP95 range of analogue addressable fire detectors uses tried and trusted technology to give the best performance and has unique features that benefit the installer and the end user. It is suitable for medium-to-large applications with simple installation requirements. As it operates using digital communication XP95 has a high immunity from corruption and is therefore often preferred in a large system where life safety is critical. XP95 products are frequently used in commercial industrial financial government ITtelecoms and healthcare applications.The new Apollo XP95 EN54-112001 compliant Manual Call Point MCP is based on the KAC conventional MCP range. It is electronically and mechanically backward compatible with previous Apollo call points based on KACs World Series product. The address of each call point is set at the commissioning stage by means of a seven-segment DIL switch.A single bi-coloured alarm LED is provided on the call point. This LED is controlled independently of the call point by the control panel. The red LED is lit when the call point has been activated. An amberyellow LED indicates a fault. Call points can be remotely tested from the panel by transmission of a single bit in the communications protocol. Call points respond by providing a value of 64 which corresponds to the alarm value.The choice of detector from the XP95 range follows well established principles of system design. The optimum detector type will depend on the type of fire riskfire load and the type of environment in which the detector is sited.Key FeaturesA seven-segment DIL switch enables the addressing of each call point at commissioning stageWhen operated the manual call point interrupts the polling cycle for a fast responseBi-coloured LEDs indicate isolate and normal conditions

GBP 51.37
1