383 results (0,14681 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Apollo Series 65 Optical Smoke Detector with Flashing LED and Magnetic Test Switch 55000-315APO

Apollo Series 65 Optical Smoke Detector with Flashing LED and Magnetic Test Switch 55000-315APO

Apollo Series 65 Optical Smoke Detector with Flashing LED and Magnetic Test Switch 55000-315APOThe Series 65 Optical Smoke Detector incorporates a pulsing LED located within the housing of the detector. The external detector moulding is identical to that of the ionisation detector and has an indicator LED which is clear in quiescent state but produces a red light in alarm.OperationThe Series 65 Optical Smoke Detector has a moulded self-extinguishing white polycarbonate case with wind resistant smoke inlets. Nickel-plated stainless-steel wiper contacts connect the detector to the base. Inside the case a printed circuit board has the optical system mounted on one side and the signal processing electronics on the other. The sensing chamber is a black moulding configured as a labyrinth which prevents penetration of ambient light. The labyrinth has a fine gauze insect-resistant cover. The chamber houses an infrared light emitting diode LED and a photo-diode which has an integral visible-light filter as extra protection against ambient light. Every three seconds the LED emits a burst of collimated light modulated at 4kHz. In clear air light from the LED does not fall directly on the diode because the LED is positioned at an obtuse angle to the diode. When smoke enters the chamber a fraction of the collimated light is scattered onto the photo-diode. If the resulting signal from the photo-diode is above a pre-set threshold the LED emits two more bursts of light this time at two-second intervals. If light is scattered onto the photo-diode by both these pulses due to the presence of smoke the detector signals an alarm state by switching the alarm latch on increasing the current drawn from the supply from about 40A to a maximum of 75mA. This fall in the impedance of the detector is recognised by the control panel as an alarm signal. The alarm current also illuminates the detector integral LED. A remote indicator connected between the L1 IN terminal and the R terminal will have a voltage equal to the supply voltage less 1 volt across it and so will illuminate. To ensure correct operation of the detector the control panel must be arranged to supply a maximum of 33 Volts dc and a minimum of 9 Volts dc in normal operation. The supply may fall to 6 Volts dc in alarm conditions if a supply current of at least 10mA is available at this voltage. To ensure effective illumination of the integral LED and any remote indicator the supply to the detector should exceed 12 Volts. To restore the detector to quiescent condition it is necessary to expel any smoke and interrupt the electrical supply to the detector for a minimum of one second.Key FeaturesResponds well to slow-burning smouldering firesWell-suited to bedrooms and escape routesUnaffected by wind or atmospheric pressureFlashing LED and magnet operated test switch option

GBP 19.98
1

Apollo Orbis CR Heat Detector with Flashing LED ORB-HT-11017-APO

Apollo Orbis A1S Heat Detector with Flashing LED ORB-HT-11167-APO

Apollo Orbis BR Heat Detector with Flashing LED ORB-HT-11015-APO

Apollo Orbis A1R Heat Detector with Flashing LED ORB-HT-11013-APO

Apollo Orbis CS Heat Detector with Flashing LED ORB-HT-11018-APO

Apollo Orbis A2S Heat Detector with Flashing LED ORB-HT-11014-APO

Apollo XP95 Zone Monitor Unit with Isolator 55000-845APO

Apollo XPander CS Heat Detector and Mounting Base - XPA-CB-11171-APO

Apollo XPander CS Heat Detector and Mounting Base - XPA-CB-11171-APO

Apollo XPander CS Heat Detector and Mounting Base - XPA-CB-11171-APOThere are two heat detectors in the XPander range designed to suit a wide variety of operating conditions. A static heat detector CS responds only when a fixed temperature has been reached and a Rate-of-Rise Detector A1R which has a fixed upper limit but in addition measures the rate of increase in temperature.Brand InformationXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves. The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface.The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.Key Features WirelessCan be used in applications where smoke detectors are unsuitableIdeal for environments that are dirty or smoky under natural conditionsCS detectors are ideal for use in the environments with rapid temperature fluctuations such as boiler roomsBi-directional monitored radio platformFiveyear battery life using standard AA alkaline batteries

GBP 187.36
1

Apollo XPander A1R Heat Detector and Mounting Base - XPA-CB-11170-APO

Apollo XPander A1R Heat Detector and Mounting Base - XPA-CB-11170-APO

Apollo XPander A1R Heat Detector and Mounting Base - XPA-CB-11170-APOThere are two heat detectors in the XPander range designed to suit a wide variety of operating conditions. A static heat detector CS responds only when a fixed temperature has been reached and a Rate-of-Rise Detector A1R which has a fixed upper limit but in addition measures the rate of increase in temperature.Brand InformationXPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves. The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface.The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.Key Features WirelessCan be used in applications where smoke detectors are unsuitableIdeal for environments that are dirty or smoky under natural conditionsCS detectors are ideal for use in the environments with rapid temperature fluctuations such as boiler roomsBi-directional monitored radio platformFiveyear battery life using standard AA alkaline batteries

GBP 188.28
1

Apollo XPander A1R Heat Detector XPA-HT-11170-APO

Apollo XPander A1R Heat Detector XPA-HT-11170-APO

Apollo XPander A1R Heat Detector XPA-HT-11170-APOThere are two heat detectors in the XPander range designed to suit a wide variety of operating conditions. A Static Heat Detector CS which responds only when a fixed temperature has been reached and a Rate-of-Rise Detector A1R which has a fixed upper limit but in addition measures the rate of increase in temperature.OperationHeat detectors have an open-web casing which allows air to flow freely across a thermistor which measures the air temperature every 2 seconds. A microprocessor stores the temperatures and compares them with pre-set values to determine whether a fixed upper limitthe alarm levelhas been reached. In the case of rate-of-rise detectors the microprocessor uses algorithms to determine how fast the temperature is increasing. Static heat detectors respond only when a fixed temperature has been reached. Rate-of-rise detectors have a fixed upper limit but they also measure the rate of increase in temperature. A fire might thus be detected at an earlier stage than with a static detector so that a rate-of-rise detector is to be preferred to a static heat detector unless sharp increases in temperature are part of the normal environment in the area protected by the heat detector.Key FeaturesWireless Can be used in applications where smoke detectors are unsuitableIdeal for environments that are dirty or smoky under normal conditionsCS detectors are ideal for use in environments with rapid temperature fluctuations such as boiler rooms Bi-directional monitored radio platformFive-year battery life using standard AA alkaline batteries

GBP 69.42
1

Apollo Marine Orbis CR Heat Detector - ORB-HT-41005-MAR

Apollo Marine Orbis A2S Heat Detector - ORB-HT-41002-MAR

Apollo Marine Orbis A1R Heat Detector - ORB-HT-41001-MAR

Apollo Marine Orbis BR Heat Detector - ORB-HT-41003-MAR

Apollo RW1000-460APO REACH Heat Detector Black Body

Apollo Orbis BS Heat Detector with Flashing LED ORB-HT-11016-APO

Apollo Orbis BS Heat Detector with Flashing LED ORB-HT-11016-APO

Apollo Orbis BS Heat Detector with Flashing LED ORB-HT-11016-APO OperationApollos Orbis heat detectors have an open-web casing which allows air to flow freely across a thermistor which measures the air temperature every 2 seconds. A microprocessor stores the temperatures and compares them with pre-set values to determine whether a fixed upper limitthe alarm levelhas been reached. In the case of rate-of-rise detectors the microprocessor uses algorithms to determine how fast the temperature is increasing. Static heat detectors respond only when a fixed temperature has been reached. Rate-of-rise detectors also have a fixed upper limit but they also measure the rate of increase in temperature. A fire might thus be detected at an earlier stage than with a static detector so that a rate-of-rise detector is to be preferred to a static heat detector unless sharp increases of heat are part of the normal environment in the area protected by the heat detector.Brand FeaturesTimeSaver Base designed for fast installationStartUp for fast commissioningFasTest reduces maintenance timeautomatic drift compensation with DirtAlert warning to easily identify dirty detectorsSensAlert which indicates that the detector is not operating properlywide voltage and operating temperature rangesoptical sensor designed for high reliability and reduced false alarm incidencemultisensory smoke detector for detecting fast-burning firesflashing LED option

GBP 15.80
1

Apollo Orbis I.S. A1R Heat Detector with Flashing LED ORB-HT-51146-APO

Apollo Orbis I.S. A1R Heat Detector with Flashing LED ORB-HT-51146-APO

Apollo Orbis I.S. A1R Heat Detector with Flashing LED ORB-HT-51146-APOThe Orbis IS Heat Detector monitors temperature by using a single thermistor network which provides a voltage output proportional to the external air temperature. The Orbis IS range incorporates seven heat detector classes to suit a wide range of operating conditions.OperationOrbis I.S. heat detectors have an open-web casing which allows air to flow freely across a thermistor which measures the air temperature every 2 seconds. A microprocessor stores the temperature and compares them with per-set values to determine whether a fixed upper limit - the alarm limit - has been reached. In the case of rate-of-rise detectors the microprocessor uses algorithms to determine how fast the temperature is increasing.Static heat detectors respond only when a fixed temperature has been reached. Rate-of-rise detectors have a fixed upper limit but they also measure the rate of increase in temperature. A fire might thus be detected at an earlier stage then with a static detector so that a rate-of-rise detector is to be preferred to a static heat detector unless sharp increases of heat are part of the normal environment in the area protected by the heat detector.Key FeaturesCan be used for applications where smoke detectors are unsuitableIdeal for environments that are dirty or smoky under normal conditionsReduced incidences of false alarmsIncreased reliability of detection

GBP 77.36
1

Apollo Orbis Marine CR Heat Detector with Flashing LED ORB-HT-41017-MAR

Apollo Orbis Marine CS Heat Detector with Flashing LED ORB-HT-41018-MAR

Apollo Marine CS Orbis Heat Detector - ORB-HT-41006-MAR

Apollo Marine CS Orbis Heat Detector - ORB-HT-41006-MAR

Apollo Marine CS Orbis Heat Detector - ORB-HT-41006-MARThe Orbis Marine Heat Detector uses a single thermistor to sense the air temperature around the detector. There are twelve heat detectors in the Orbis Marine range designed to suit a wide variety of operating conditions.OperationOrbis heat detectors have an open-web casing which allows air to flow freely across a thermistor which measures the air temperature every 2 seconds. A microprocessor stores the temperatures and compares them with pre-set values to determine whether a fixed upper limit the alarm level has been reached. In the case of rate-of-rise detectors the microprocessor uses algorithms to determine how fast the temperature is increasing.Static heat detectors respond only when a fixed temperature has been reached. Rate-of-rise detectors also have a fixed upper limit but they also measure the rate of increase in temperature. A fire might thus be detected at an earlier stage than with a static detector so that a rate-of-rise detector is to be preferred to a static heat detector unless sharp increases of heat are part of the normal environment in the area protected by the heat detector.Key FeaturesCan be used for applications where smoke detectors are unsuitableIdeal for environments that are dirty or smoky under normal conditionsApproved for use in marine environmentsModern low-profile designTimeSaver Base for fast installationTransient rejection for false alarm reductionHigh humidity tolerance at up to 98RHWide operating temperature -40C to 70C

GBP 20.99
1

Apollo Marine DIN-Rail Zone Monitor 55000-773MAR

Apollo RW1000-400APO Reach Optical Heat Detector

Apollo Marine Orbis BS Heat Detector - ORB-HT-41004-MAR

Apollo XP95 DIN-RAIL Zone Monitor with Isolator - 55000-812APO