379 results (0,24825 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Apollo Series 65 Standard Base - 45681-200APO

Apollo Series 65 Marine Mounting Base 45681-200MAR

Apollo Series 65 Diode Base 45681-201APO

Apollo Series 65 Diode Base 45681-201APO

Apollo Series 65 Diode Base 45681-201The Series 65 Diode Base is designed for use with conventional systems that have manual call points and detector bases on the same circuit. The base is fitted with a schottky diode on the L1 IN and L1 OUT wiring terminals.This base can only be used with compatible control equipment.OperationAll detectors in the Series 65 range fit into Series 60 standard mounting bases. The bases are of 100mm diameter and have five terminals marked according to their function Line 1 in line 1 out line 2 in and out remote indicator negative earth. Detectors are polarity insensitive so that identification of positive and negative lines is only required if a remote LED is fitted. An earth connection is not required for either safety or correct operation of detectors.The earth terminal is provided for tidy termination of earthed conductors or cable screens and to maintain earth continuity where necessary. Bases have a wide interior diameter for ease of access to cables and terminals and there are two slots for fixing screws at a spacing of 51 to 69mm. Detectors fit into bases one way only and require clockwise rotation without push force to be plugged in.Key FeaturesDetector locking mechanismOne way fitEasy to wireContains an earth connectorContinues to work during unauthorised removal of detectorsBrand FeaturesWide-operating voltage of 933 V DCWide-operating and storage temperature of -20C to 60CCan be used on security systemsElectrically and mechanically compatible with Series 60Proven detection performance

GBP 2.60
1

Apollo Series 65 Standard Relay Base 45681-245APO

Apollo Series 65 Auxiliary Relay Base 45681-246APO

Apollo XP95 Intelligent Mounting Base 45681-210APO

Apollo XP95 Intelligent Mounting Base 45681-210APO

Apollo XP95 Mounting Base - 45681-210APOAll detectors in the Discovery range fit the IntelligentMounting Base. The Mounting Base is a low insertion force base with stainless steel contacts for the detector terminals. XPERT cards are supplied with all bases.Universal address cards known as XPERT cards are supplied with all bases. Consult the coding guide in the installation instructions to determine which pips are to be removed from the card to give the correct address.Lay the card on a flat surface pips down insert a screwdriver into the slot on the reverse of the pip to be removed and give a firm twist. When the card is coded insert it into the slot in the side of the appropriate base making sure that the card locks itself into place. As a detector is inserted into the base the remaining pips operate the address buttons on the detector and the detector electronics reads the address.OperatingAn earth connection is not required for either safety or correct operation of detectors. The ground earth terminal is isolated and is provided for tidy termination of grounded conductors or cable screens and to maintain earth continuity where necessary. All terminals are marked according to their function.Bases have a wide interior diameter for ease of access to cables and terminals and there are two slots for fixing screws. The slots enable two fixing screws to be located at a spacing of 51mm to 69mm. Detectors fit into bases one way only without snagging and require clockwise rotation without push force to be plugged in.Key Features XPERT AddressingOne way fit of detectorLocking feature to prevent unauthorised detector removal

GBP 2.50
1

Apollo Series 65 Relay Base 12v 45681-508APO

Apollo Series 65 Relay Base 12v 45681-508APO

Apollo Series 65 Relay Base 12v 45681-508The Series 65 12V Relay Base is designed for use in both fire and security systems. For fire systems a jumper on the PCB is fitted to a latching position. For security systems the jumper is moved to another position so that the base is non-latching.OperationSeries 65 Relay Bases are primarily intended for use with control units using 4-wire detector supply and alarm initiating circuits. Where local codes allow they may also be used in 2 and 4-wire circuits to provide volt-free control signals to an auxiliary system such as an automatic door closer. They are not suitable for use in systems where it is specified or required that operation of the auxiliary system shall be fail-safe and must not be used with any other type of detector.Mechanical ConstructionThe base is a white self-extinguishing polycarbonate moulding with zero-force nickel-plated steel terminals for attaching the detector. The moulding has an aperture to accept the locking grub screw built into the detector case. All electronic components including the relay are mounted on a PCB which is retained by two screws in the moulding.Product InformationThe Series 65 12V Relay Base is designed for use in both fire and security systems. For fire systems a jumper on the PCB is fitted to a latching position. For security systems the jumper is moved to another position so that the base is non-latching.Key FeaturesDetector locking mechanismOne-way fitEasy to wireContains an earth connectorCan be used in fire and security systems

GBP 9.76
1

Apollo Series 65 Sav-wire Base 45681-206APO

Apollo Series 65 End-of-Line Relay Base 12V - 45681-247APO

Apollo Series 65 End-of-Line Relay Base - 24V 45681-248APO

Apollo AlarmSense Manual Call Point 55400-894APO

Apollo SA5900-928MAR Intelligent Marine Manual Call Point

Apollo SA5900-928MAR Intelligent Marine Manual Call Point

Apollo SA5900-928MAR Intelligent Marine Manual Call PointThe Intelligent Marine Manual Call Point MCP has been designed to operate on a loop of intelligent fire detection devices. An alarm is initiated by pressing the resettable element. The MCP signals to the Fire Control Panel using an interrupt feature within the Apollo Digital Communication Protocol. An alarm status is indicated through the rotation of the resettable element displaying yellow and black indication bars and a solid red LED. The MCP can be easily reset from the front using the supplied reset key. The Intelligent Marine MCP is intended for indoor marine and offshore applications and has a built-in short circuit isolator.OperationThe address of each call point is set at the commissioning stage by means of a DIL switch. A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and CoreProtocol configurable. Once activated the Intelligent Marine Manual Call Point SIL Approved can be reset by inserting the reset key into the front facing LED turning clockwise until a positive click and reset occurs.The Intelligent Marine Manual Call Point incorporates a short circuit isolator which will ensure its operation in the event of a short circuit fault on the loop. Isolator operation is indicated by a solid yellow LED.Key FeaturesResettable element for testingEasy access front reset mechanismA unique ergonomically designedKey for resetting and front cover removal

GBP 53.21
1

Apollo End-to-End Optical Beam Detector 29600-929

Apollo SC2900-001APO Conventional Manual Call Point

Apollo Discovery Red Open-Area Sounder Beacon - 58000-005APO

Apollo 58002-350APO Discovery Base Sounder Visual Indicator White Flash

Apollo 58002-351APO Discovery Base Sounder Visual Indicator Red Flash

Apollo SA7800-870APO Touch Screen Portable Test Set Unit

Apollo SA7800-870APO Touch Screen Portable Test Set Unit

Apollo SA7800-870APO Touch Screen Portable Test Set UnitThe Apollo Test Set is a portable test unit featuring a touch screen display capable of providing several functions in interrogating and controlling all devices connected to the unit either individual devices or compete circuits of analogue addressable devices in the Apollo ranges CoreProtocol Discovery and XP95.How does the product workThe standard view allows devices to be scanned and controlled through the manipulation of the devices output bits. Devices can also be self-tested using the test set and the different functionality modes can also be controlled. The unit may be powered from an AC mains charger unit or from its own internal batteries. The loop or individual address can be connected to the unit using loop connection ports which are located on the top of the device.What problem does this help solveThe device also has the functionality to test the diagnostics and integrity of the loop to find earth faults etc. The device offers fault finding capabilities which allows for time spent on site to be cut down during the commissioning stage of the system installation. The result of this is time reduced on site for the end user which reduces the overall costs of installing Apollo systems.Kit ContainsThe Apollo Test Set UnitA universal chargerTwo red connector cablesTwo black connector cablesTwo yellow connector cablesGreen connector cableXPERT 8 Intelligent Mounting BaseCarry strapQuick Start Guide

GBP 828.46
1

Apollo SA5500-351APO Open-Area Sounder VID Red Body Red Flash

Apollo Discovery amp XP95 Intelligent Manual Call Point SA5900-908APO

Apollo Discovery amp XP95 Intelligent Manual Call Point SA5900-908APO

Apollo Discovery XP95 Intelligent Manual Call Point SA5900-908APOThe Intelligent Manual Call Point has been designed to operate on a loop of intelligent fire detection devices. An alarm is initiated by pressing the resettable element. The manual call point signals to the Control and Indicating Equipment using an interrupt feature within the Apollo Digital Protocol.An alarm status is indicated through the rotation of the resettable element displaying yellow and black indication bars and a solid red LED. The manual call point can be easily reset from the front using the supplied reset key.Key FeaturesResettable operating elementEasy access front reset mechanismE-Z fit connector system for installationErgonomic reset keyEN 54-11 EN 54-17 Certified Red version only170 viewable LEDContinuity link for cable insulation testingSuitable for semi flush or surface mountingOperating PrinciplesThe address of each call point is set at the commissioning stage by means of a DIL switch.A solid red alarm LED is provided on the manual call point. This LED is controlled independently of the call point by the control panel. The LED will flash yellow if there is a fault and flash green when the device is polled. Discovery and CoreProtocol configurable.Once activated the Intelligent Manual Call Point can be reset by inserting the reset key into the front facing LED turning clockwise until a positive click and reset occurs.The Intelligent Manual Call Point incorporates a short circuit isolator which will ensure its operation in the event of a short circuit fault on the loop. Isolator operation is indicated by a solid yellow LED.This manual call point helps reduce installation time as all the initial installation cabling is wired to a removable terminal block which fits neatly in the back of the manual call point.Protocol CompatibilityThe Intelligent Manual Call Point will operate with compatible Apollo control equipment using the digital XP95 Discovery and CoreProtocols.Electrical ConsiderationThe Intelligent Manual Call Point is loop powered and operates at 17-35V DC for all variants.

GBP 35.77
1

Apollo SA5501-351APO Open-Area Sounder VID White Body Red Flash

Apollo SA5501-350APO Open-Area Sounder VID White Body White Flash

Apollo SA5500-350APO Open-Area Sounder VID Red Body White Flash

Apollo Discovery Clear Open-Area Sounder Beacon - 58000-007APO