26 results (0,14290 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

C-Tec CFP EN54-13 Interface Board BF354

C-Tec CFP EN54-13 Sounder Circuit Fault Monitoring Module BF355

C-Tec NCP-13 Wipe Clean Anti-Bacterial Ceiling Pull Cord Pack

C-Tec BF370S Sycall Red Surface Mounting No Break Fire Call Point

C-Tec BF370SW Sycall Red IP66 Surface Mounting No Break Fire Call Point

C-Tec BF370FR FUL Universal Call Point Red

C-Tec BF370FRW FUL IP67 Universal Call Point Red

C-Tec CFP702-4 2 Zone Conventional Fire Panel LPCB Approved

C-Tec CFP702-4 2 Zone Conventional Fire Panel LPCB Approved

C-Tec CFP 2 Zone Conventional Fire Panel LPCB Approved - CFP702-4LPCB certified to EN54-24 C-TECs CFP 2 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price. Supplied in an attractive flush or surface mountable plastic enclosure it includes two detector zones four conventional sounder circuits class change and alert inputs on-board fire and fault relays and combined keypadkey switch entry.A wide range of engineering functions are also provided including selectable zone delays coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided. Optional repeaters relay expansion boards and EN54-13 system compliance devices are also available.Key FeaturesThird-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board LPCB with optional EN54 part 13 compliance from the BSI.Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry.Manufactured by C-TEC in the UK.Two detector zone circuits.Four conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSU.Wide range of engineering functions including zone test coincidence zone delay and non-latching zones.Two on-board relays Fire and Fault.Two open-collector outputs Remote and Reset.Class change and alert inputs.Installer-friendly design.Attractive flush or surface mountable plastic lid and enclosure - no bezel required.Low 25mA quiescent current.Multiple indicators.System expansion connections provided for up to eight two-wire repeaters one CFP761 network card required per system optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.Space for two x 12V 3.3Ah VRLA batteries.Fully compatible with C-TECs ActiV range of conventional fire detectors.

GBP 130.25
1

C-Tec CFP 4 Zone Conventional Fire Panel LPCB Approved - CFP704-4

C-Tec CFP 4 Zone Conventional Fire Panel LPCB Approved - CFP704-4

C-Tec CFP 4 Zone Conventional Fire Panel LPCB Approved - CFP704-4LPCB certified to EN54-24 C-TECs CFP 4 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price. Supplied in an attractive flush or surface mountable plastic enclosure it includes two detector zones four conventional sounder circuits class change and alert inputs on-board fire and fault relays and combined keypadkey switch entry.A wide range of engineering functions are also provided including selectable zone delays coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided. Optional repeaters relay expansion boards and EN54-13 system compliance devices are also available.Key FeaturesThird-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board LPCB with optional EN54 part 13 compliance from the BSI.Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry.Manufactured by C-TEC in the UK.Two detector zone circuits.Four conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSU.Wide range of engineering functions including zone test coincidence zone delay and non-latching zones.Two on-board relays Fire and Fault.Two open-collector outputs Remote and Reset.Class change and alert inputs.Installer-friendly design.Attractive flush or surface mountable plastic lid and enclosure - no bezel required.Low 25mA quiescent current.Multiple indicators.System expansion connections provided for up to eight two-wire repeaters one CFP761 network card required per system optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.Space for two x 12V 3.3Ah VRLA batteries.Fully compatible with C-TECs ActiV range of conventional fire detectors.

GBP 148.46
1

C-Tec CFP708-4 8 Zone Conventional Fire Panel LPCB Approved

C-Tec CFP708-4 8 Zone Conventional Fire Panel LPCB Approved

C-Tec CFP 8 Zone Conventional Fire Panel LPCB Approved - CFP708-4LPCB certified to EN54-24 C-TECs CFP 8 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price. Supplied in an attractive flush or surface mountable plastic enclosure it includes two detector zones four conventional sounder circuits class change and alert inputs on-board fire and fault relays and combined keypadkey switch entry.A wide range of engineering functions are also provided including selectable zone delays coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided. Optional repeaters relay expansion boards and EN54-13 system compliance devices are also available.Key FeaturesThird-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board LPCB with optional EN54 part 13 compliance from the BSI.Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry.Manufactured by C-TEC in the UK.Two detector zone circuits.Four conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSU.Wide range of engineering functions including zone test coincidence zone delay and non-latching zones.Two on-board relays Fire and Fault.Two open-collector outputs Remote and Reset.Class change and alert inputs.Installer-friendly design.Attractive flush or surface mountable plastic lid and enclosure - no bezel required.Low 25mA quiescent current.Multiple indicators.System expansion connections provided for up to eight two-wire repeaters one CFP761 network card required per system optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.Space for two x 12V 3.3Ah VRLA batteries.Fully compatible with C-TECs ActiV range of conventional fire detectors.

GBP 208.82
1

C-Tec BF441CF3 FUL Solista LX 24V Ceiling VAD White Body - Red Flash Shallow Body

C-Tec BF433CF7 FUL Symphoni LX 24V Wall Sounder VAD Red Body - Red Flash

C-Tec CA431AW CA Base Sounder White

C-Tec CA432AW CA O Class Base Sounder VAD - White

C-Tec CA430ADR65 CA Wall Sounder Deep IP5565 Red

C-Tec BF433CF5 FUL ROLP LX 24V W Class Sounder VAD - Red Body - Red Flash

C-Tec BF440CF1 FUL Solista LX 24V Wall VAD Red Body - Red Flash Shallow Base

C-Tec BF440CF1 FUL Solista LX 24V Wall VAD Red Body - Red Flash Shallow Base

C-Tec BF440CF1 FUL Solista LX 24V Wall VAD Red Body - Red Flash Shallow BaseThe Solista LX visual alarm device VAD is an EN54-23 rated fire alarm beacon. Achieved through its unique lens design which distributes light in a highly controlled pattern it achieves the required illumination specific by EN54-23 while drawing a low current consumption.Taking its design principles from the popular Solista Maxi the Solista LX is compact and slim blending in when its not required and standing out when it is. Now in its second generation it features soft-start technology enabling the maximum product loading and protection against overloading and fault.The patented long life LED lens optics used in the LX have been developed specifically for the VAD EN54-23 standard.It uses modern thick-mould injection moulding techniques and innovative cylindrical output to achieve the correct level of illumination while keeping power consumption as low as possible.The 2nd generation of the LX now incorporates soft-start technology. This innovative feature constantly monitors the available voltage to give zero start up surge on the line allowing maximum product loading. It can also detect line overloading and will indicate the fault with a rapid double flash.Key FeaturesCertified to EN54 Parts 23 AFNOR and 13 BSIProvides W-2.4-7.5 coverage switchable to W-2.4-2.5 if required10-25mA alarm current depending on settingAttractive slim designUltra-bright red LEDIdeal for use in bedrooms bathrooms and toilets

GBP 36.13
1

C-TEC XFP501CA XFP 1 loop 32 Zone Panel C-TEC CAST. Max. 2 x 7Ah Batteries

C-TEC XFP501CA XFP 1 loop 32 Zone Panel C-TEC CAST. Max. 2 x 7Ah Batteries

C-TEC XFP501CA XFP 1 loop 32 Zone Panel C-TEC CAST. Max. 2 x 7Ah BatteriesC-TECs tried and trusted XFP oneloop 32 zoneaddressable fire alarm panel - now available with C-TECs own digital fire alarm system protocol CAST and fully certified to EN54 parts 2 4 and 13.With a powerful 40V 450mA loop driver allowing the connection of up to 255 CAST devices the installation of a robust feature-packed addressable fire alarm system has never been easier.Always thought of the XFP as an entry-level fire panel Think again. Thanks to CASTs multiple type codes high speed data transmission and two speedy soft addressing options automatic via the panel or manually via a handheld programmerdevice tester it is undoubtedly one of the most powerful one loop fire panels around. This and its ability to sit on a network of up to 8 XFP master panels makes it ideal for use in small to medium sized stand-alone applications and larger more sophisticated installations alike.Protocol FeaturesCAST is the worlds most-advanced distributed intelligence fire alarm system protocol. Conceived designed and realised by C-TEC as part of a five-year multi-million pound project it involved the creation of a powerful proprietary communication protocol C-TEC Addressable System Technology CAST and multiple control panels field devices.Key Features 255 devices per loop. Autonomous decision-making for faster response times. Multiple type codes. 40V loop drive voltage. Two soft addressing options automatic via the panel or manual via a powerful handheld programmer. Powerful multi-level addressing facilitates easy device addition and swapped device identification. Multiple functionality at a single address integrated devices - due 2021. Volumes tones detector modes can be changed at compatible panels. High-speed data transmission and robust data transfer. Provides geographical location of short and open circuit faults a short circuit isolator is included as standard in every CAST field device. Replace device function. Programmable multi-function status LED. Future seamless integration with other CAST life safety systems reducing energy servicing installation and repair costs. ENVISION Enabled - fully compliant with our new ENVISION Cloud-based Fire IoT Remote Access System Test and Site Management software package. Designed and manufactured in the UK.Panel Features Certifiedto EN54-24 by the Loss Prevention Certification Board LPCB and EN54-13 by Kiwa Telefication. Two independently programmable conventional sounder circuits. Two programmable inputs. A fault output relay and three programmable relay outputs with voltage free changeover contacts. A selection of zone dependencycoincidence functions. A daynight building occupiedunoccupied function. An investigation delay period function. Phased evacuation facility. An alarm counter that records how many times the panel has been in alarm state. Powerful short circuit protected loop drivers. An integral EN54-4A2 switch mode. Adjustable contamination levels. Earth fault monitoring. Combined keypad keyswitch entry to Access Levels 2 and 3. 500 event monitoring. An intuitive Windows based upload-download PC program. Up to eight XFP main panels any variant can be connected onto a two-wire RS485 non-redundantnetwork. Alternatively up to eight XFP repeaters can be connected to any non-networked main panel.Cast Commissioning Services available with this Equipment

GBP 557.02
1

C-TEC XFP501ECA XFP 1 Loop 16 Zone Panel C-TEC CAST. Max. 2 x 3.2Ah Batteries

C-TEC XFP501ECA XFP 1 Loop 16 Zone Panel C-TEC CAST. Max. 2 x 3.2Ah Batteries

C-TEC XFP501ECA XFP 1 Loop 16 Zone Panel C-TEC CAST. Max. 2 x 3.2Ah BatteriesC-TECs tried and trusted XFP oneloop 16zoneaddressable fire alarm panel - now available with C-TECs own digital fire alarm system protocol CAST and fully certified to EN54 parts 2 4 and 13.With a powerful 40V 500mA loop driver allowing the connection of up to 255 CAST devices the installation of a cost-effective feature-packed addressable fire alarm system has never been easier.Always thought of the XFP as an entry-level fire panel Think again. Thanks to CASTs multiple type codes high speed data transmission and two speedy soft addressing options automatic via the panel or manually via a handheld programmerdevice tester it is undoubtedly one of the most powerful single loop fire panels around. This and its ability to sit on a network of up to 8 XFP master panels makes it ideal for use in small to medium sized stand-alone applications and larger more sophisticated installations alike.Protocol FeaturesCAST is the worlds most-advanced distributed intelligence fire alarm system protocol. Conceived designed and realised by C-TEC as part of a five-year multi-million pound project it involved the creation of a powerful proprietary communication protocol C-TEC Addressable System Technology CAST and multiple control panels field devices. Now available to purchase.Key Features 255 devices per loop. Autonomous decision-making for faster response times. Multiple type codes. 40V loop drive voltage. Two soft addressing options automatic via the panel or manual via a powerful handheld programmer. Powerful multi-level addressing facilitates easy device addition and swapped device identification. Multiple functionality at a single address integrated devices - due 2021. Volumes tones detector modes can be changed at compatible panels. High-speed data transmission and robust data transfer. Provides geographical location of short and open circuit faults a short circuit isolator is included as standard in every CAST field device. Replace device function. Programmable multi-function status LED. Future seamless integration with other CAST life safety systems reducing energy servicing installation and repair costs. ENVISION Enabled - fully compliant with our new ENVISION Cloud-based Fire IoT Remote Access System Test and Site Management software package. Designed and manufactured in the UK.Panel Features Certifiedto EN54-24 by the Loss Prevention Certification Board LPCB and EN54-13 by Kiwa Telefication. Two independently programmable conventional sounder circuits. Two programmable inputs. A fault output relay and three programmable relay outputs with voltage free changeover contacts. A selection of zone dependencycoincidence functions. A daynight building occupiedunoccupied function. An investigation delay period function. Phased evacuation facility. An alarm counter that records how many times the panel has been in alarm state. Powerful short circuit protected loop drivers. An integral EN54-4A2 switch mode. Adjustable contamination levels. Earth fault monitoring. Combined keypad keyswitch entry to Access Levels 2 and 3. 500 event monitoring. An intuitive Windows based upload-download PC program. Up to eight XFP main panels any variant can be connected onto a two-wire RS485 non-redundantnetwork. Alternatively up to eight XFP repeaters can be connected to any non-networked main panel.Cast Commissioning Services available with this Equipment

GBP 381.44
1

C-TEC XFP502CA XFP 2 loop 32 Zone Panel C-TEC CAST. Max. 2 x 7Ah batteries

C-TEC XFP502CA XFP 2 loop 32 Zone Panel C-TEC CAST. Max. 2 x 7Ah batteries

C-TEC XFP502CA XFP 2 loop 32 Zone Panel C-TEC CAST. Max. 2 x 7Ah batteriesC-TECs tried and trusted XFP two loop 32 zoneaddressable fire alarm panel - now available with C-TECs own digital fire alarm system protocol CAST and fully certified to EN54 parts 2 4 13.With two powerful 40V 450mA loop drivers allowing the connection of up to 255 CAST devices per loop the installation of a robust feature-packed addressable fire alarm system has never been easier.Always thought of the XFP as an entry-level fire panel Think again. Thanks to CASTs multiple type codes high speed data transmission and two speedy soft addressing options automatic via the panel or manually via a handheld programmerdevice tester it is undoubtedly one of the most powerful two loop fire panels around. This and its ability to sit on a network of up to 8 XFP master panels makes it ideal for use in small to medium sized stand-alone applications and larger more sophisticated installations alike.Protocol FeaturesCAST is the worlds most-advanced distributed intelligence fire alarm system protocol. Conceived designed and realised by C-TEC as part of a five-year multi-million pound project it involved the creation of a powerful proprietary communication protocol C-TEC Addressable System Technology CAST and multiple control panels field devices. Key features include 255 devices per loop. Autonomous decision-making for faster response times. Multiple type codes. 40V loop drive voltage. Two soft addressing options automatic via the panel or manual via a powerful handheld programmer. Powerful multi-level addressing facilitates easy device addition and swapped device identification. Multiple functionality at a single address integrated devices - due 2021. Volumes tones detector modes can be changed at compatible panels. High-speed data transmission and robust data transfer. Provides geographical location of short and open circuit faults a short circuit isolator is included as standard in every CAST field device. Replace device function. Programmable multi-function status LED. Future seamless integration with other CAST life safety systems reducing energy servicing installation and repair costs. ENVISION Enabled - fully compliant with our new ENVISION Cloud-based Fire IoT Remote Access System Test and Site Management software package. Designed and manufactured in the UK.Panel Features Certifiedto EN54-24 by the Loss Prevention Certification Board LPCB and EN54-13 by Kiwa Telefication. Two independently programmable conventional sounder circuits. Two programmable inputs. A fault output relay and three programmable relay outputs with voltage free changeover contacts. A selection of zone dependencycoincidence functions. A daynight building occupiedunoccupied function. An investigation delay period function. Phased evacuation facility. An alarm counter that records how many times the panel has been in alarm state. Powerful short circuit protected loop drivers. An integral EN54-4A2 switch mode. Adjustable contamination levels. Earth fault monitoring. Combined keypad keyswitch entry to Access Levels 2 and 3. 500 event monitoring. An intuitive Windows based upload-download PC program. Up to eight XFP main panels any variant can be connected onto a two-wire RS485 non-redundantnetwork. Alternatively up to eight XFP repeaters can be connected to any non-networked main panel.Cast Commissioning Services available with this Equipment

GBP 701.32
1

C-Tec CAPROG CAST Handheld Device Programmer Testing Tool

C-Tec CAPROG CAST Handheld Device Programmer Testing Tool

C-Tec CAPROG CAST Handheld Device Programmer Testing ToolCAST is the worlds most-advanced distributed intelligence fire alarm system protocol. Conceived designed and realised by C-TEC as part of a five-year multi-million pound project it involved the creation of a powerful proprietary communication protocol C-TEC Addressable System Technology CAST and multiple control panels field devices.Key FeaturesAn easy-to-use handheld device programmertester for use with C-TECs CAST addressable fire alarm systems.Assigns CAST detectors manual call points sounders VADs and interface units with a User ID in seconds.Allows a CAST devices outputs to be tested by switching on its sounder VAD or relay.Allows CAST input devices to be tested by showing for example when a smoked CAST detector has gone into alarm.Battery powered.Auto shutdown feature helps preserve battery life.Backlit LCD with adjustable contrast control.Includes an integrated base for direct connection to CAST detectors and soundersVADs jack socket also provided for CAST ancillary device programming.255 devices per loopAutonomous decision-making for faster response times.Multiple type codes.40V loop drive voltage.Two soft addressing options automatic via the panel or manual via a powerful handheld programmer.Powerful multi-level addressing facilitates easy device addition and swapped device identification.Multiple functionality at a single address integrated devices - due 2017.Volumes tones detector modes can be changed at compatible panels.High-speed data transmission and robust data transfer.Intrinsically EN54-13 compliant.Provides geographical location of short and open circuit faults a short circuit isolator is included as standard in every CAST field device.Replace device function.Flashing and non-flashing polling LED option.Future seamless integration with other CAST life safety systems reducing energy servicing installation and repair costs.Designed and manufactured in the UK.

GBP 163.08
1