41 results (0,15844 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

C-Tec EP215 Hold Off Abort Switch Single Gang

C-Tec NC887D Conventional Switchable Sounder

C-Tec NC888D Conventional Remote Sounder

C-Tec BF375P Unregulated Door Release PSU on Double Gang Plate

C-Tec FF596 MFP 8 Zone Repeater Panel

C-Tec ZFP220CA ZFP 2 Loop 5A 20LED CAST

C-Tec ZFP1CA ZFP 1 Loop Panel 5A CAST

C-Tec ZFP240CA ZFP 2 Loop Panel 5A 40LED CAST

C-Tec ZFP2CA ZFP 2 Loop Panel 5A Cast

C-Tec ZFP120CA ZFP 1 Loop Panel 5A 20LED CAST

C-Tec ZFP140CA ZFP 1 Loop Panel 5A 40LED CAST

C-Tec BF326RF Fire Alarm Mains Isolator Keyswitch - Red Flush

C-Tec ZFP240PCA ZFP 2 Loop Panel 5A 40LED CAST cw Printer

C-Tec ZFP140PCA ZFP 1 Loop Panel 5A 40LED CAST cw Printer

C-Tec ZFP120PCA ZFP 1 Loop Panel 5A 20LED CAST cw Printer

C-Tec NC894DKB Conventional Isolatable Monitoring Point with Button Reset and Door Contacts

C-Tec ZFP220PCA ZFP 2 Loop Panel 5A 20LED CAST cw Printer

C-Tec QT951 Quantec Addressable Accessible Toilet Alarm Kit

C-Tec QT951 Quantec Addressable Accessible Toilet Alarm Kit

C-Tec QT951 Quantec Addressable Accessible Toilet Alarm KitA cost-effective expansion kit that adds true BS8300 compliant accessible toilet alarm functionality to a Quantec Addressable Call System. Includes a QT607 ceiling pull unit a QT605S reset point cw confidence sounder a Quantec slave overdoor light cw sounder and an NC949 Accessible Toilet Sticker.Key FeaturesAllows people in distress to call for help quickly and easily.Call acknowledgement function provides audible visual feedback inside the WC that help is on the way see Operation section below.Staff can Accept alarm calls at a Quantec display.Multiple kits can be used on one Quantec system.Includes a free MRSA resistant anti-bacterial pull cord pack for a limited period only.Backwards compatible.Must be used in conjunction with at least one Quantec Controller.Operating1. The distressed person raises an alarm by pulling the cord on the QT607 Ceiling Pull Unit.Inside the WC The red reassurance LED on the QT607 Ceiling Pull Unit and the reassurance LED and sounder on the QT605S Reset Point cw Sounder pulse Quantecs standard call sequence 0.5 seconds on and 0.5 seconds off to reassure the user the call has been registered.Outside the WC The Alarm LEDs and sounder on the QT606S Overdoor Light cw Sounder pulse Quantecs standard call sequence 0.5 seconds on 0.5 seconds off and a message appears on all relevant Quantec displays as programmed to let staff know someone is in need of assistance.2. The member of staff responding to the Alarm call presses the Call Accept button on a Quantec DisplayInside the WC The reassurance LED and sounder on the QT605S Reset Point cw Sounder pulse Quantecs Call Acknowledged sequence 0.5 seconds on 3 seconds off redgreen to let the user know help is on the way.3. Once assistance has been provided the Alarm call is cancelled from inside the WC by pressing the RESET button on the QT605S Reset Point cw SounderInside and outside the WC All relevant indicators display messages and sounders are extinguished and the calling device returns to its normal state.If the RESET button on the QT605S is NOT pressed when in the call acknowledged state after a period of 1 to 8 minutes as programmed it generates another AlarmStandard call on the system.

GBP 110.95
1

C-Tec BF326RS Fire Alarm Mains Isolator Keyswitch - Red Surface Includes Back Box

C-Tec BF326RSL Fire Alarm Mains Isolator Keyswitch - Red LED Surface Includes Back Box

C-Tec BF326WF Fire Alarm Mains Isolator Keyswitch White Flush

C-Tec BF320 24V BS 5446-3 Vibrating Pillow Pad

C-Tec BF320 24V BS 5446-3 Vibrating Pillow Pad

C-Tec BF320 24V BS 5446-3 Vibrating Pillow PadCan be used in conjunction with a BF320JP connection plate to warn the hearing impaired of a potential fire alarm or evacuation alert condition. Vibrates and pulses on and off when triggered as per the requirements of BS 5446-3 2015. Designed to be placed under a pillow to supplement the audible andor visual indication alerts provided by a systems sounders andor VADs. Wide10-30V DC voltage range means it can also be connected to many third-party connector plates subject to testing. Includes a 2m connection lead with a locking mini-XLR connector to prevent accidental removal. Includes a 6K8 end-of-line monitoring resistor for fire alarm system use - see instructions for monitoring options on other systems. Supersedes our old BF363 pillow pad.Key FeaturesCan be used in conjunction with aBF320JP connection plateto warnthe hearing impaired of a potential fire alarm or evacuation alert condition.Vibrates and pulses on and off when triggered as per the requirements of BS 5446-3 2015.Designed to be placed under a pillow to supplement the audible andor visual indication alertsprovided by a systems sounders andor VADs.Wide10-30V DC voltagerange means it can also be connected tomanythird-party connector plates subject to testing.Includes a 2m connection lead with a locking mini-XLR connector to prevent accidental removal.Includes a 6K8 end-of-line monitoring resistor for fire alarm system use - see instructions for monitoring options on other systems.Supersedes our old BF363 pillow pad.

GBP 24.16
1