344 results (0,26895 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

C-Tec BF375P Unregulated Door Release PSU on Double Gang Plate

C-Tec BF366 Isolatable Relay on a Plate 24v 5A

C-Tec BF366 Isolatable Relay on a Plate 24v 5A

C-Tec BF366 Isolatable Relay on a Plate 24v 5AThe BF366 is a double-pole 24V 5A polarised relay specifically designed for use in 24V fire alarm systems. It includes a key switch isolation facility allowing the relay operation to be temporarily disabled from the fire alarm signal during routine test and maintenance to prevent auto diallers water sprinklers roller shutters etc. from activating.Mountable on a 25mm flush or surface mount back box the relay is trigger able via a control panels open collector output or a standard polarised fire alarm sounder circuit. If connecting to a sounder circuit note that the relay will return to its normal state when the fire condition is cleared or silenced. Check with the approving authority that the proposed arrangement is acceptable prior to installation.Key FeaturesA 24V 5A polarised relay designed for use in 24V fire alarm systemsIncludes a keyswitch isolation facility allowing the relay operation to be temporarily disabled during routine test and maintenance to prevent auto diallers water sprinklers roller shutters etc. from activatingWhen isolated the units Isolated LED will flash and a warning beeper will sound every 8 seconds to ensure devices are not inadvertently left in the isolated stateRelay is triggerable via a control panels open collector output or a standard polarised fire alarm sounder circuit if connecting to a sounder circuit the relay will return to its normal state when the fire condition is cleared or silenced - check with the approving authority that this arrangement is acceptable prior to installationFits on standard UK 25mm flush or surface mount back boxes

GBP 23.32
1

C-Tec BF376 Relay on a Plate 24v 5A Single Gang

C-Tec BF376 Relay on a Plate 24v 5A Single Gang

BF376 Relay on a Plate 24v 5A Single GangThe BF376 is a general purpose double-pole polarised 24V 5A relay designed for use in 24V fire alarm systems. It incorporates a high intensity LED which illuminates red when the relay is active. It may be connected to a suitable control panel relay output or a standard polarised fire alarm sounder circuit to operate door retaining magnets roller shutter doors etc.Please note if connecting to a sounder circuit the relay will return to its normal state when the fire condition is cleared or silenced. Check with the approving authority that the proposed arrangement is acceptable prior to installation. The relay can be mounted on 25mm flush or surface mount back boxes. Mains wiring if used should be provided in accordance with the current edition of the IEE Wiring Regs.16th.Ed.The general requirement for any mains supply to the BF376 is fixed wiring using three core cable not less than 1mm2 fed from an isolating switch fuse spur fused at 5A max. This should be exclusive to the BF376 and its load and be labelled accordingly. As an alternative to a switched fused spur any double pole isolating device with a contact separation of 3mm or greater which is fitted with suitable in-circuit protection devices and meets the appropriate national wiring regulations can be used.Technical InformationActivation current Typically 30mA 24VDCIndicators Red relay activated LEDConnections V -V Supply NC C NO SW1 SW2. Contact rating 24Vdc is 5A resistive 2A inductive Contact rating 240Vac is 5A resistive 2A inductiveProduct dimensions mm 85w x 85h x 27d mm can be mounted onto a standard UK 25mm single gang flush or surface back boxConstruction finish White PVC plate light grey label silver nickel contactsIP Rating IP40Weight 78gOperating temperature -10C to 60CKey FeaturesA general purpose double-pole polarised 24V 5A relay designed for use in 24V fire alarm systemsIncorporates a high intensity LED which illuminates red when the relay is activeCan be connected to a suitable control panel relay output or a standard polarised fire alarm sounder circuit to operate door retaining magnets rollershutter doors etcCan be mounted on 25mm flush or surface mount back boxes

GBP 8.15
1

C-Tec QT951 Quantec Addressable Accessible Toilet Alarm Kit

C-Tec QT951 Quantec Addressable Accessible Toilet Alarm Kit

C-Tec QT951 Quantec Addressable Accessible Toilet Alarm KitA cost-effective expansion kit that adds true BS8300 compliant accessible toilet alarm functionality to a Quantec Addressable Call System. Includes a QT607 ceiling pull unit a QT605S reset point cw confidence sounder a Quantec slave overdoor light cw sounder and an NC949 Accessible Toilet Sticker.Key FeaturesAllows people in distress to call for help quickly and easily.Call acknowledgement function provides audible visual feedback inside the WC that help is on the way see Operation section below.Staff can Accept alarm calls at a Quantec display.Multiple kits can be used on one Quantec system.Includes a free MRSA resistant anti-bacterial pull cord pack for a limited period only.Backwards compatible.Must be used in conjunction with at least one Quantec Controller.Operating1. The distressed person raises an alarm by pulling the cord on the QT607 Ceiling Pull Unit.Inside the WC The red reassurance LED on the QT607 Ceiling Pull Unit and the reassurance LED and sounder on the QT605S Reset Point cw Sounder pulse Quantecs standard call sequence 0.5 seconds on and 0.5 seconds off to reassure the user the call has been registered.Outside the WC The Alarm LEDs and sounder on the QT606S Overdoor Light cw Sounder pulse Quantecs standard call sequence 0.5 seconds on 0.5 seconds off and a message appears on all relevant Quantec displays as programmed to let staff know someone is in need of assistance.2. The member of staff responding to the Alarm call presses the Call Accept button on a Quantec DisplayInside the WC The reassurance LED and sounder on the QT605S Reset Point cw Sounder pulse Quantecs Call Acknowledged sequence 0.5 seconds on 3 seconds off redgreen to let the user know help is on the way.3. Once assistance has been provided the Alarm call is cancelled from inside the WC by pressing the RESET button on the QT605S Reset Point cw SounderInside and outside the WC All relevant indicators display messages and sounders are extinguished and the calling device returns to its normal state.If the RESET button on the QT605S is NOT pressed when in the call acknowledged state after a period of 1 to 8 minutes as programmed it generates another AlarmStandard call on the system.

GBP 110.95
1

C-Tec QT616 Quantec InfraredRadio Fall Sensor

C-Tec BF367 Auxiliary Device Isolator single gang

C-Tec BF367 Auxiliary Device Isolator single gang

BF367 Auxiliary Device Isolator single gangThe BF367 allows a 24V d.c. output from a fire alarm control panel to be remotely isolated to prevent external equipment such as auto diallers roller shutter doors etc from operating. This is a particularly useful function during routine test and maintenance as it safeguards against the inadvertent and potentially hazardous triggering of auxiliary equipment.To aid location the BF367s front label has a white write on panel allowing installers to add their own personalised text such as equipment locations. The unit will fit on 25mm deep flush or surface mount back boxes.Key FeaturesThe BF367 incorporates an isolating key switch and a high intensity amber LEDThe switch circuit has been designed so that if monitoring is used on the 24V d.c. output being controlled a fault condition will show at the fire panel when the BF367s key switch is in the ISOLATED position note that the key can be removed from the key switch in both the ON and ISOLATED positionsThe units amber LED can also be set-up to illuminate when the key switch is in the ISOLATED position provided sufficient voltage is presentAllows a 24 VDC output from a fire alarm control panel to be remotely isolated to prevent autodiallers water sprinklers rollershutters etc. from activatingDesigned so that if monitoring is used on the 24 VDC output being controlled a fault condition will show at the fire panel when the device is IsolatedLabel includes a white write on area allowing installers to add equipment locationsFits on standard UK 25mm flush or surface mount back boxes

GBP 21.18
1

C-Tec BF319 Fire Alarm Control Panel Mains Key Switch

C-Tec NC804DE Conventional Emergency Call Reset Point with Button Reset

C-Tec NC910EF 10 Zone Expansion Unit for NC910F or NC920F

C-Tec NC910ES 10 Zone Expansion Unit for NC910S or NC920S

C-Tec NC920EF 20 Zone Expansion Unit for NC910F or NC920F

C-Tec NC920ES 20 Zone Expansion Unit for NC910S or NC920S

C-Tec NC802DB Conventional Call Point with Button Reset and Remote Socket

C-Tec CA736 EACIE 1 Way Flat Interface - Double Gang

C-Tec NC802DEB-12 Conventional Emergency Call Point with Button Reset and Remote Socket

C-Tec SPE0849000 NC802DB cw QT602E Label

C-Tec NC943B Conventional Single Zone Call Controller