719 results (0,14006 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

C-Tec NC803M10 Magnetic Reset Keys Pack of 10

C-Tec QT432S Spare Wrist Straps Pack of 10

C-Tec QT603 Quantec Network Splitter

C-Tec QT603 Quantec Network Splitter

C-Tec QT603 Quantec Network SplitterQuantec utilises a unique data protocol that works down two wires andamaximum of 255 addressable devices can be connected to a Quantec Controller dependent on network topology.Addressable devices require 2 network connections. Slave devices such as slave ceiling pullsandslave overdoor lights connect to Quantec via a master call point master ceiling receiver monitoring point or universal programming device using 2 3 or 4 cores of stranded security cable.Wiring must bemade in a Spine and Limb configuration using one or more QT603 network splitters. This allowsthe use of ordinary unscreened cable which simplifies installation fault-finding and commissioning.Key FeaturesAn essential wiringinstallation aid for C-TECsQuantec Addressable Call System.Helps protect against open and short circuit faults and reduces the risk of volt drop.Includes one input and one output connection for Quantecs Spine wiring typically 1.5-2.5mm TE and sixfused 400mA limb connections for the wiring of individual circuits containing Quantecs fielddevices typically 4 core stranded security cable.At least one QT603 is required perQuantec system the more you use the easier it will beto program and fault-find.Install one QT603 per corridor junction locate at the end of the corridor nearest to the Quantec Controller.Ifthe corridor is longer than 50m install the splitter in the centre of the corridor to reduce wiring runs.Mounts on a standard 25mm UK double gang back box.Power and Fault indicators.Max.60 addressable devices per QT603.

GBP 29.40
1

C-Tec C4403A1R ActiV Class A1R Rate of Rise Heat Detector

C-Tec PDA200E AKW1 Hearing Loop Kit for Place of Worship with Fixed Lectern Microphone

C-Tec PDA200E AKW1 Hearing Loop Kit for Place of Worship with Fixed Lectern Microphone

C-Tec PDA200E AKW1 Hearing Loop Kit for Place of Worship with Fixed Lectern MicrophoneHearing loop systems allow hearing impaired people to hear more clearly. Most hearing aids have a T or MT switch which allows them to pick up the electromagnetic field generated by a hearing loop system. The hearing aid converts this signal into a sound suited to its users specific hearing requirements.Any person with a hearing aid positioned within or near the loop can hear the loop signal by switching their hearing aid to the correct position allowing them to participate more effectively in general conversation ordering goods or services listening to public performances etc.Includes a PDA200E hearingloop amplifier AML lectern microphone APJ 3.5mm jack input plate APL line level audio inputplate and 2 x 6m of Belden cable. Ideal for creatinga high-quality hearingloop system for a place of worship.Key FeaturesWall-mountable PDA200E amplifier capable of driving a perimeter loop of up to 200m2.Internal drive level and metal compensation controls.Two balanced unbalanced line level inputs.One microphone input with 12V phantom power for electret microphones.Full compatibility with the Outreach plate audio input extension system.Fully compliant withBS EN 60118-4 when correctly installed.Technical SpecificationInduction Loop Type Wall mounting requires fixed mains wiringCoverage 200m2 approx.Dimensions W 273 x H 200 x D 77mm amplifier only 2.82kgInputs 1 x Microphone 2 x LineOutreachIndicators Input level Power Compression Peak Current 321Controls Metal Compensation Input level loop drivePlease Note the AK range of hearing loop kits dont come with loop cable please use 1mm2 single core cable such as C-Tecs LOOP2W cable.

GBP 452.76
1

C-Tec PDA200E AKW2H Hearing Loop Kit for Place of Worship with Handheld Radio Microphone 200m2

C-Tec PDA200E AKW2H Hearing Loop Kit for Place of Worship with Handheld Radio Microphone 200m2

C-Tec PDA200E AKW2H Hearing Loop Kit for Place of Worship with Handheld Radio Microphone 200m2Hearing loop systems allow hearing impaired people to hear more clearly. Most hearing aids have a T or MT switch which allows them to pick up the electromagnetic field generated by a hearing loop system. The hearing aid converts this signal into a sound suited to its users specific hearing requirements.Any person with a hearing aid positioned within or near the loop can hear the loop signal by switching their hearing aid to the correct position allowing them to participate more effectively in general conversation ordering goods or services listening to public performances etc.Includes a PDA200E hearing loop amplifierAMRHA handheld radio microphone APJ outreach plate APXMoutreach plate for use with existing mics and 2 x 6m of Belden cable. Ideal for creatinga high-quality hearingloop system for aTV or Music lounge.Key FeaturesWall-mountable PDA200E amplifier capable of driving a perimeter loop of up to 200m2.Internal drive level and metal compensation controls.Two balanced unbalanced line level inputs.One microphone input with 12V phantom power for electret microphones.Full compatibility with the Outreach plate audio input extension system.Fully compliant withBS EN 60118-4 when correctly installed.AMRHA handheld radio microphone kit includes receiver transmitter PSU and 4 selectable frequencies.Technical SpecificationInduction Loop Type Wall mounting requires fixed mains wiringCoverage 200m2 approx.Dimensions W 273 x H 200 x D 77mm amplifier only 2.82kgInputs 1 x Microphone 2 x LineOutreachIndicators Input level Power Compression Peak Current 321Controls Metal Compensation Input level loop drivePlease Note the AK range of hearing loop kits dont come with loop cable please use 1mm2 single core cable such as C-Tecs LOOP2W cable.

GBP 992.46
1

C-Tec PDA200E AKW2L Hearing Loop Kit for Place of Worship with Levalier Radio Microphone 200m2

C-Tec PDA200E AKW2L Hearing Loop Kit for Place of Worship with Levalier Radio Microphone 200m2

C-Tec PDA200E AKW2L Hearing Loop Kit for Place of Worship with Levalier Radio Microphone 200m2Hearing loop systems allow hearing impaired people to hear more clearly. Most hearing aids have a T or MT switch which allows them to pick up the electromagnetic field generated by a hearing loop system. The hearing aid converts this signal into a sound suited to its users specific hearing requirements.Any person with a hearing aid positioned within or near the loop can hear the loop signal by switching their hearing aid to the correct position allowing them to participate more effectively in general conversation ordering goods or services listening to public performances etc.Includes a PDA200E hearing loop amplifier AMRLA lavalier radio microphone APJ outreach plateAPXM outreach plate for use with existing mics and 2 x 6m Belden cable. Ideal for creatinga high-quality hearingloop system for a place of worship.Key FeaturesWall-mountable PDA200E amplifier capable of driving a perimeter loop of up to 200m2.Internal drive level and metal compensation controls.Two balanced unbalanced line level inputs.One microphone input with 12V phantom power for electret microphones.Full compatibility with the Outreach plate audio input extension system.Fully compliant withBS EN 60118-4 when correctly installed.AMRLA lavalier radio microphone kit includes receiver transmitter PSU and 4 selectable frequencies.Technical SpecificationInduction Loop Type Wall mounting requires fixed mains wiringCoverage 200m2 approx.Dimensions W 273 x H 200 x D 77mm amplifier only 2.82kgInputs 1 x Microphone 2 x LineOutreachIndicators Input level Power Compression Peak Current 321Controls Metal Compensation Input level loop drivePlease Note the AK range of hearing loop kits dont come with loop cable please use 1mm2 single core cable such as C-Tecs LOOP2W cable.

GBP 992.46
1

C-Tec QT601-2 Quantec Controller

C-Tec QT601-2 Quantec Controller

C-Tec QT601-2 Quantec ControllerQuantec is a powerful yet easy to use addressable call system that helps ensure vital communication throughout a building. In environments where efficiency is paramount Quantec delivers helping save staff time minimising disturbance and improving the quality of patient customer or employee care. Whatever the application - be it a call system for a nursing home hospital hotel or leisure centre or a staff protection system for a high dependency unit prison factory shop school or council office - Quantec is the obvious choice.With its flexible call routing multiple call levels a unique data protocol that works down just two wires and a laptop programmable system controller Quantec can be tailored to suit the exact operational needs of any building. For example calls can be routed to different parts of a site at different times of the day and unanswered calls can be set to transfer to other areas after a pre-determined time. As well as a huge range of cost-effective call points ceiling pulls displays monitoring points sounders neck pendants and infrared transmitters the system includes a host of industry-leading features.The controller supplies power to and controls a Quantec Addressable Call System. Monitors all network devices and manages the routing and distribution of all calls. Provides connections for network wiring standby batteries a laptop for system programmingoptionalpagingDECT equipment anoptionalprinter orPC to run Quantecs QT707S Surveyor data management software.Key FeaturesIncludes a library of 40 pre-set 45 custom place names.System setup requires a laptop PC running Quantecs QT707 programming tools.Can be semi-flush mounted using an QT385 bezel or fully-flushed using a BF3593S stainless steel enclosure.System wiring requires one or more QT603 network splitters.Wiring should be made in a spine and limb arrangement using 1.5 to 2.5mm2 TE spines and 4 to 8 core stranded security cable limbs.

GBP 426.65
1

C-TEC BF375PEK Double Gang Automatic Door Release System

C-TEC BF375PEK Double Gang Automatic Door Release System

C-TEC BF375PEK Double Gang Automatic Door Release SystemAn ancillary function of many fire alarm systems is the automatic closure of fire doors in the event of a fire. On larger systems however it is not always practical to globally shut all of a buildings fire doors particularly if the fire is consigned to a distant secure area. With this in mind in addition to demanding the installation of a standard fire alarm system an increasing number of specifications are also calling for independent self-contained door release systems sited locally to each set of fire doors. C-TECs BF375PEK is one such system.The system includes a compact 24V 250mA double gang power supply featuring an on-board detector circuit two optical smoke detectors and bases and one electromagnetic door retainer. In normal conditions the power supply energizes the door retainer to hold the fire door open. On each side of the door a smoke detector is installed.Should one or more of the detectors go into alarm the door will close. For added protection depending on how the system is wired the door will also close if one or both of the smoke detectors is removed from its base if there is an open or short circuit if the mains fails if the power supplys on-board manual release button is pressed or if an optional external manual release button is activated Although only one electromagnetic door retainer is supplied with the BF375PEK additional magnets can be connected. In most instances however only two magnets will be required to handle one setpair of fire doors.The Kit Includes1 No. C-Tec BF375PE Double Gang 24V 250mA Door Release PSU2 No. Apollo 55000-317 Conventional Optical Smoke Detectors Bases1 No. 24V DC Wall Mounted Door Detent Keeper Plate1 No. NCP-10 Flush Backbox

GBP 144.16
1

C-Tec CA408 CA Detector Base

C-Tec C4408 ActiV Standard Non-Diode Base

C-Tec PDA103I Intercom AFILS IP65 Surface

C-Tec CA408B CA Detector Base Black

C-Tec BF365SC Sounder Isolator Controller

C-Tec BF365SC Sounder Isolator Controller

BF365SC Sounder Isolator ControllerBF365SC Conventional Sounder Controller and its associated BF365IM Isolator Modules are designed to interface to a fire alarm panels conventional sounder circuit. The Modules each of which would typically have a conventional sounder connected to it are wired in a loop arrangement beginning and ending at the controller. The Controller transforms the conventional sounder circuits monitoring and triggering voltages into its own unique control voltages which it uses to trigger the Isolator Modules and monitor the sounder loop wiring.Each Module has smart sensing which means if a wiring fault should occur the Modules nearest to the faulty section of cabling will if needed isolate this section. As the Modules are driven from each direction any loss of cable integrity will have no effect on the functionality of the actual sounders. Having a fault tolerant arrangement such as this means that low cost cabling can be used for the sounder circuit subject to the fire officers approval leading to significant savings in installation.Key FeaturesDesigned to meet requirement 17.9.2c of Dutch standard NEN2575BSI certified to EN54 parts 17 18Easily interfaced to a conventional fire alarm sounder circuitAllows low-cost non-fire resistant sounder circuit cabling to be used when used in conjunction with our BF365IM Isolator Modules subject to fire officer approval.Wiring must be made in a loop arrangement beginning and ending at the controllerIf a wiring fault should occur the Modules nearest to the faulty section of cabling will if needed isolate this section. As the Modules are driven from each direction any loss of cable integrity will have no effect on the functionality of the actual soundersFits on standard UK 25mm flush or surface mount back boxesNot suitable for use in the UK

GBP 77.21
1