10 results (0,14232 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

C-Tec EVC401PH Roaming Fire Telephone Handset

C-Tec BF560-24 Switch Mode 24v 1.5A EN54-4 Boxed PSU

C-Tec CA739 CAST 4 Way Sounder Controller Extendable To 8 Way ZFP ONLY

C-Tec NC805AS Air Switch

C-Tec QT644 Floor Pressure Mat

C-Tec QT637 Quantec Enuresis General Purpose Interface Socket

C-Tec BF562-1 Switch Mode 24v 1.5A EN54-4 Boxed Metal PSU

C-Tec BF562-1 Switch Mode 24v 1.5A EN54-4 Boxed Metal PSU

C-Tec BF562-1 Switch Mode 24v 1.5A EN54-4 Boxed Metal PSUThe BF562-1 is certified to EN54-4A2 by the LPCB and VdS AFNOR pending. It comes with a plastic cover on PSU PCB which guards against touching live parts. Includes a single-pole voltfree changeover relay that switches for any fault condition.Key FeaturesMultiple indicators - supply present general fault fault type aux. equipment faultTwo selectable battery charge currentsBattery fault impedance limits can be optimised to suit load current helps extend battery lifeMains fail simulation modeImproved on-board temperature sensor with optional remote sensorElectronic functions comply with EN50131-6 grades 1-4 for security applicationsBF562-1E caged BF562-1C PCB-only versions availableTYPICAL USESIdeal for poweringbeam detectors auto-dial communicators aspirating smoke detectors auto-open vent systems auxiliary sounder systems or any other device performing a mandatory function of a fire alarm system.PSU CUSTOMISATIONThe BF562-1can be customised to suit your exact requirements using a BF423 configurator PC. Configurable parameters include float voltage temperature compensation battery charge rate mA battery impedance and configurableInputOutput settings. It is important to note changing the PSUs parameters in this way isoutside the scope of EN54-4 and any changes mustbe tested by the responsible person for correctoperation.PSU STATUS LEDlocated on the PSU PCB1 flash Mains Failure.2 flashes Battery Voltage Low.3 flashes Battery Voltage Critical.4 flashes Charger Failure.5 flashes Charger OK Battery is either actively charging or in float charge.6 flashes No Batteries Fitted indicating DIP Switch 4 position.7 flashes Battery Resistance Fault Level set by DIP Switch 2 position.8flashes Output Over Voltage.BATTERY FAULT MONITORINGThe BF562-1 complies with EN54-4A2 and therefore must monitor battery resistance. The fault threshold is directly related to the ability of the battery to deliver the rated current to the load. For example batteries stored uncharged for long periods during shipment andor distribution degrade leading to increased internal resistance. If a degraded battery is fitted a fault will be shown by the PSU as mandated by EN54-4A2.DATA PORTData on the BF562-1s status can be extracted from the PSUsbi-directional data port. The data availableincludes thermistor measurements battery terminal voltage system voltage at load terminals battery charge current load current battery impedanceandASCII text string status messages. Extracting this data requires additional equipment and permissions - contact C-TEC for details.

GBP 155.72
1

C-Tec CAPROG CAST Handheld Device Programmer Testing Tool

C-Tec CAPROG CAST Handheld Device Programmer Testing Tool

C-Tec CAPROG CAST Handheld Device Programmer Testing ToolCAST is the worlds most-advanced distributed intelligence fire alarm system protocol. Conceived designed and realised by C-TEC as part of a five-year multi-million pound project it involved the creation of a powerful proprietary communication protocol C-TEC Addressable System Technology CAST and multiple control panels field devices.Key FeaturesAn easy-to-use handheld device programmertester for use with C-TECs CAST addressable fire alarm systems.Assigns CAST detectors manual call points sounders VADs and interface units with a User ID in seconds.Allows a CAST devices outputs to be tested by switching on its sounder VAD or relay.Allows CAST input devices to be tested by showing for example when a smoked CAST detector has gone into alarm.Battery powered.Auto shutdown feature helps preserve battery life.Backlit LCD with adjustable contrast control.Includes an integrated base for direct connection to CAST detectors and soundersVADs jack socket also provided for CAST ancillary device programming.255 devices per loopAutonomous decision-making for faster response times.Multiple type codes.40V loop drive voltage.Two soft addressing options automatic via the panel or manual via a powerful handheld programmer.Powerful multi-level addressing facilitates easy device addition and swapped device identification.Multiple functionality at a single address integrated devices - due 2017.Volumes tones detector modes can be changed at compatible panels.High-speed data transmission and robust data transfer.Intrinsically EN54-13 compliant.Provides geographical location of short and open circuit faults a short circuit isolator is included as standard in every CAST field device.Replace device function.Flashing and non-flashing polling LED option.Future seamless integration with other CAST life safety systems reducing energy servicing installation and repair costs.Designed and manufactured in the UK.

GBP 163.08
1

C-Tec BF560-12 Switch Mode 12v 2A EN54-4 Boxed PSU

C-Tec BF560-12 Switch Mode 12v 2A EN54-4 Boxed PSU

C-Tec BF560-12 Switch Mode 12v 2A EN54-4 Boxed PSUThe C-Tec BF560-12 12V 2A EN54-4 Switch Mode PSU is ideal for connecting to 12V security STUs to provide BS5839-1 compliant remote monitoring facilities. It is certified to EN54-4A2 by the LPCB VdS AFNOR pending.Key FeaturesMultiple indicators - supply present general fault fault type aux. equipment fault.Two selectable battery charge currents.Battery fault impedance limits can be optimised to suit load current helps extend battery life.Mains fail simulation mode.Improved on-board temperature sensor with optional remote sensor.Ideal for connecting to 12V security STUs to provide BS5839-1 compliant remote monitoring facilities.Electronic functions comply with EN50131-6 grades 1-4 for security applications.BF560-12E Caged BF560-12C PCB-only versions available.Plastic cover on PSU PCB guards against touching live parts.Includes a single-pole voltfree changeover relay that switches for any fault condition.Additional InformationPSU CUSTOMISATIONThe BF560-12can be customised to suit your exact requirements using a BF423 configurator PC. Configurable parameters include float voltage temperature compensation battery charge rate mA battery impedance and configurableInputOutput settings. It is important to note changing the PSUs parameters in this way isoutside the scope of EN54-4 and any changes mustbe tested by the responsible person for correctoperation.12V SECURITY STUUSED PURELY FOR FIRE ALARM SIGNALLINGThe BF560-12 can help combat an area of fire alarm system non-compliance that is often overlooked - their connection to remote monitoring centres via 12V security STUs or autodiallers. Firesystems that require such monitoring are typically connected to 12V security STUs. Unfortunately PSUs used to power these STUs normally only offer 12 hours standby are notconnected to a dedicated mains supply and do not include the features demanded by EN54-4 such as battery impedance monitoring temperature compensated charging CPR compliance etc. TheBF560-12 solves these problems by allowing the use of 12V STUs with a cost-effective EN54-4 compliant PSU thereby facilitating compliance with BS5839-1 or European equivalents. Tofurther assist this application an optional STU mounting plate is available for inside the BF560-12 order code BF360SP.PSU STATUS LEDlocated on the PSU PCB1 flash Mains Failure.2 flashes Battery Voltage Low.3 flashes Battery Voltage Critical.4 flashes Charger Failure.5 flashes Charger OK Battery is either actively charging or in float charge.6 flashes No Batteries Fitted indicating DIP Switch 4 position.7 flashes Battery Resistance Fault Level set by DIP Switch 2 position.8flashes Output Over Voltage.BATTERY FAULT MONITORINGThe BF560-12 complies with EN54-4A2 and therefore must monitor battery resistance. The fault threshold is directly related to the ability of the battery to deliver the rated current to the load. For example batteries stored uncharged for long periods during shipment andor distribution degrade leading to increased internal resistance. If a degraded battery is fitted a fault will be shown by the PSU as mandated by EN54-4A2.EN50131-6 POWER SUPPLIES FOR INTRUSION HOLD UP ALARMS CAPABILITYThe power supply inside the BF560-12 has all the electrical functions required to comply with EN50131-6 Grade 4which includes Grades 3 2 and 1. However the BF560-12s enclosure isnot designed to comply with the standardsrequirements totriggeranalarm if someone tries to force the box open. OEM security companies interested in utilising the BF560-12s PSUPCB inside their own EN50131-6 compliant tamper-resistant enclosures should contact our marketing departmentfor further detailson costs and approvals.DATA PORTData on the BF560-12s status can be extracted from the PSUsbi-directional data port. The data availableincludes thermistor measurements battery terminal voltage system voltage at load terminals battery charge current load current battery impedanceandASCII text string status messages. Extracting this data requires additional equipment and permissions -call C-TEC for details.

GBP 113.64
1