27 results (0,12653 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

C-Tec CAPROG CAST Handheld Device Programmer Testing Tool

C-Tec CAPROG CAST Handheld Device Programmer Testing Tool

C-Tec CAPROG CAST Handheld Device Programmer Testing ToolCAST is the worlds most-advanced distributed intelligence fire alarm system protocol. Conceived designed and realised by C-TEC as part of a five-year multi-million pound project it involved the creation of a powerful proprietary communication protocol C-TEC Addressable System Technology CAST and multiple control panels field devices.Key FeaturesAn easy-to-use handheld device programmertester for use with C-TECs CAST addressable fire alarm systems.Assigns CAST detectors manual call points sounders VADs and interface units with a User ID in seconds.Allows a CAST devices outputs to be tested by switching on its sounder VAD or relay.Allows CAST input devices to be tested by showing for example when a smoked CAST detector has gone into alarm.Battery powered.Auto shutdown feature helps preserve battery life.Backlit LCD with adjustable contrast control.Includes an integrated base for direct connection to CAST detectors and soundersVADs jack socket also provided for CAST ancillary device programming.255 devices per loopAutonomous decision-making for faster response times.Multiple type codes.40V loop drive voltage.Two soft addressing options automatic via the panel or manual via a powerful handheld programmer.Powerful multi-level addressing facilitates easy device addition and swapped device identification.Multiple functionality at a single address integrated devices - due 2017.Volumes tones detector modes can be changed at compatible panels.High-speed data transmission and robust data transfer.Intrinsically EN54-13 compliant.Provides geographical location of short and open circuit faults a short circuit isolator is included as standard in every CAST field device.Replace device function.Flashing and non-flashing polling LED option.Future seamless integration with other CAST life safety systems reducing energy servicing installation and repair costs.Designed and manufactured in the UK.

GBP 163.08
1

C-Tec 24V 3A EN54-4 Switch Mode PSU BF562-3

C-Tec BF433CEASW Wall Sounder VID - Self Testing - White

C-Tec QT616 Quantec InfraredRadio Fall Sensor

C-Tec QT421 Quantec RF Integrity Transmitter

C-Tec NC943B Conventional Single Zone Call Controller

C-Tec BF433CEASR Wall Sounder VID - Self Testing - Red

C-Tec CA739 CAST 4 Way Sounder Controller Extendable To 8 Way ZFP ONLY

C-Tec QT412RXCA Infrared Radio Transmitter Push for Call Pull for Attack

C-Tec QT412RXA Infrared Radio Transmitter Push for Attack Pull for Attack

C-Tec Output Expansion Relay Board EP212

C-Tec CP414TVR CAST-PRO Smoke Heat Multisensor cw Tone Sounder amp O-C-1.9-4 Red VAD

C-Tec CP411TV CAST-PRO CO Fire Smoke Heat Multisensor cw Tone Sounder amp C-3-9.4 White VAD

C-Tec CP414TV CAST-PRO Smoke Heat Multisensor cw Tone Sounder amp C-3-9.4 White VAD

C-Tec CP414V CAST-PRO Smoke Heat Multisensor cw Voice Sounder

C-Tec CP411V CAST-PRO CO Fire Smoke Heat Multisensor cw Voice Sounder

C-Tec CP411TVR CAST-PRO CO Fire Smoke Heat Multisensor cw Tone Sounder amp O-C-1.9-4 Red VAD

C-Tec CP414VV CAST-PRO Smoke Heat Multisensor cw Voice Sounder amp C-3-9.4 White VAD

C-Tec CP414VVR CAST-PRO Smoke Heat Multisensor cw Voice Sounder amp O-C-1.9-4 Red VAD

C-Tec STI-6400GR STI Exit Alarm Stopper- Green

C-Tec STI-6400GR STI Exit Alarm Stopper- Green

C-Tec STI-6400GR STI Exit Alarm Stopper- GreenThe Exit Stopper is a unique and highly effective way toalert you to any unauthorised exits or entries through emergency exit doors. Itcan also serve as an inexpensive security device and help prevent theft. It canbe mounted or installed on almost any type of door including remote placementof the sounder. The highly visible STOP sign discourages unauthorised use ofemergency doors.If the protected door is opened the electronic Exit Stopperemits an ear-piercing alarm for 30 seconds 3 minutes or continuously aspre-set by the user. A key operated override facility will silence the alarmand allow authorised exits. When the door is closed a number of reset optionsare available including an automatic function. A variety of alarm durations andsetup features are available see User Programmable Features chart overleaf.The Exit Stopper is fitted with a 9V PP3 alkaline battery.Key FeaturesPrevent unauthorised exits and entries through emergencyexit doorsCompact design 136mm diameter and 50mm deepHighly visible STOP sign design acts as a deterrentVirtually indestructible polycarbonate cover isUV-stabilisedHighly versatile can be mounted or installed on any type ofdoor including remote placement of sounderCan be installed and protecting doors in minutesStand-alone alarm systemPowered by a 9V PP3 alkaline battery includedIncorporates a 1224 VDC connection40 milliamp 9 VDC trigger outputIn exit alarm mode alarm can be set to sound for 30seconds 3 minutes or indefinitely unless disarmed with key supplied or untilbattery is drainedIn annunciator mode it announces door entry with a set of10 beepsMay be programmed for 15 second entry delay or immediatealarmArming delay allows unit to arm followingauthorised exits

GBP 155.23
1

C-Tec AFP711 XFP Network Communications Card

C-Tec AFP711 XFP Network Communications Card

C-Tec AFP711 XFP Network Communications CardAn optional system expansion device for use with XFP 12 Loop 32 Zone fire panels. Allowsthe connection of up to eight XFP Repeaters or eight XFP Main panels any mix on an RS485 network. One AFP711 card required per networked Main XFP 12 Loop 32 Zone panel note that XFP510-16 and XFP510-32 repeaters include a network driver card as standard.The AFP711 is NOT compatible with XFP Single Loop 16 Zone panels which require a CFP761 card for networking.Key network protocol features when used for interconnecting XFP main panelsCan be used to connect up to 8 XFP main panels any mix over a two-wire RS485 network of up to 1KM in length.Each networked XFP can be programmed to accept Fires Faults and Control actions such as Silence Alarm Sounders and Control Panel Resets from other panels.Each XFP will accept Disablement commands for zones sounders and output sets from other panels.All panels monitored for network wiring faults.Fires and faults on remote panels are displayed on local panels including the point description.CEs can be programmed into local panels dependent on which remote panel is in alarm.The network supports the programming of site data into remote panels from a PC at a local panel.Time and date is common to all panels.All networked main panels require a network communication card.It is not possible to mix XFP main panels and XFP repeaters on the same network.Key network protocol features when used for connecting XFP repeatersCan be used to connect up to 8 XFP repeaters any mix to one XFP main panel.Up to 500m of cable may be fitted to an XFP two-wire repeater network.Each XFP repeater offers all the functions and controls of an XFP main panel.The XFP main panel must have a network communication card fitted.It is not possible to mix XFP main panels and XFP repeaters on the same network.

GBP 114.65
1