35 results (0,14068 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

C-Tec QT412RXCA Infrared Radio Transmitter Push for Call Pull for Attack

C-Tec QT645 Quantec PIR Power Interface with Isolating Key Switch

C-Tec QT412RXA Infrared Radio Transmitter Push for Attack Pull for Attack

C-Tec BF560-24 Switch Mode 24v 1.5A EN54-4 Boxed PSU

C-Tec BF562-1 Switch Mode 24v 1.5A EN54-4 Boxed Metal PSU

C-Tec BF562-1 Switch Mode 24v 1.5A EN54-4 Boxed Metal PSU

C-Tec BF562-1 Switch Mode 24v 1.5A EN54-4 Boxed Metal PSUThe BF562-1 is certified to EN54-4A2 by the LPCB and VdS AFNOR pending. It comes with a plastic cover on PSU PCB which guards against touching live parts. Includes a single-pole voltfree changeover relay that switches for any fault condition.Key FeaturesMultiple indicators - supply present general fault fault type aux. equipment faultTwo selectable battery charge currentsBattery fault impedance limits can be optimised to suit load current helps extend battery lifeMains fail simulation modeImproved on-board temperature sensor with optional remote sensorElectronic functions comply with EN50131-6 grades 1-4 for security applicationsBF562-1E caged BF562-1C PCB-only versions availableTYPICAL USESIdeal for poweringbeam detectors auto-dial communicators aspirating smoke detectors auto-open vent systems auxiliary sounder systems or any other device performing a mandatory function of a fire alarm system.PSU CUSTOMISATIONThe BF562-1can be customised to suit your exact requirements using a BF423 configurator PC. Configurable parameters include float voltage temperature compensation battery charge rate mA battery impedance and configurableInputOutput settings. It is important to note changing the PSUs parameters in this way isoutside the scope of EN54-4 and any changes mustbe tested by the responsible person for correctoperation.PSU STATUS LEDlocated on the PSU PCB1 flash Mains Failure.2 flashes Battery Voltage Low.3 flashes Battery Voltage Critical.4 flashes Charger Failure.5 flashes Charger OK Battery is either actively charging or in float charge.6 flashes No Batteries Fitted indicating DIP Switch 4 position.7 flashes Battery Resistance Fault Level set by DIP Switch 2 position.8flashes Output Over Voltage.BATTERY FAULT MONITORINGThe BF562-1 complies with EN54-4A2 and therefore must monitor battery resistance. The fault threshold is directly related to the ability of the battery to deliver the rated current to the load. For example batteries stored uncharged for long periods during shipment andor distribution degrade leading to increased internal resistance. If a degraded battery is fitted a fault will be shown by the PSU as mandated by EN54-4A2.DATA PORTData on the BF562-1s status can be extracted from the PSUsbi-directional data port. The data availableincludes thermistor measurements battery terminal voltage system voltage at load terminals battery charge current load current battery impedanceandASCII text string status messages. Extracting this data requires additional equipment and permissions - contact C-TEC for details.

GBP 155.72
1

C-Tec BF560-12 Switch Mode 12v 2A EN54-4 Boxed PSU

C-Tec BF560-12 Switch Mode 12v 2A EN54-4 Boxed PSU

C-Tec BF560-12 Switch Mode 12v 2A EN54-4 Boxed PSUThe C-Tec BF560-12 12V 2A EN54-4 Switch Mode PSU is ideal for connecting to 12V security STUs to provide BS5839-1 compliant remote monitoring facilities. It is certified to EN54-4A2 by the LPCB VdS AFNOR pending.Key FeaturesMultiple indicators - supply present general fault fault type aux. equipment fault.Two selectable battery charge currents.Battery fault impedance limits can be optimised to suit load current helps extend battery life.Mains fail simulation mode.Improved on-board temperature sensor with optional remote sensor.Ideal for connecting to 12V security STUs to provide BS5839-1 compliant remote monitoring facilities.Electronic functions comply with EN50131-6 grades 1-4 for security applications.BF560-12E Caged BF560-12C PCB-only versions available.Plastic cover on PSU PCB guards against touching live parts.Includes a single-pole voltfree changeover relay that switches for any fault condition.Additional InformationPSU CUSTOMISATIONThe BF560-12can be customised to suit your exact requirements using a BF423 configurator PC. Configurable parameters include float voltage temperature compensation battery charge rate mA battery impedance and configurableInputOutput settings. It is important to note changing the PSUs parameters in this way isoutside the scope of EN54-4 and any changes mustbe tested by the responsible person for correctoperation.12V SECURITY STUUSED PURELY FOR FIRE ALARM SIGNALLINGThe BF560-12 can help combat an area of fire alarm system non-compliance that is often overlooked - their connection to remote monitoring centres via 12V security STUs or autodiallers. Firesystems that require such monitoring are typically connected to 12V security STUs. Unfortunately PSUs used to power these STUs normally only offer 12 hours standby are notconnected to a dedicated mains supply and do not include the features demanded by EN54-4 such as battery impedance monitoring temperature compensated charging CPR compliance etc. TheBF560-12 solves these problems by allowing the use of 12V STUs with a cost-effective EN54-4 compliant PSU thereby facilitating compliance with BS5839-1 or European equivalents. Tofurther assist this application an optional STU mounting plate is available for inside the BF560-12 order code BF360SP.PSU STATUS LEDlocated on the PSU PCB1 flash Mains Failure.2 flashes Battery Voltage Low.3 flashes Battery Voltage Critical.4 flashes Charger Failure.5 flashes Charger OK Battery is either actively charging or in float charge.6 flashes No Batteries Fitted indicating DIP Switch 4 position.7 flashes Battery Resistance Fault Level set by DIP Switch 2 position.8flashes Output Over Voltage.BATTERY FAULT MONITORINGThe BF560-12 complies with EN54-4A2 and therefore must monitor battery resistance. The fault threshold is directly related to the ability of the battery to deliver the rated current to the load. For example batteries stored uncharged for long periods during shipment andor distribution degrade leading to increased internal resistance. If a degraded battery is fitted a fault will be shown by the PSU as mandated by EN54-4A2.EN50131-6 POWER SUPPLIES FOR INTRUSION HOLD UP ALARMS CAPABILITYThe power supply inside the BF560-12 has all the electrical functions required to comply with EN50131-6 Grade 4which includes Grades 3 2 and 1. However the BF560-12s enclosure isnot designed to comply with the standardsrequirements totriggeranalarm if someone tries to force the box open. OEM security companies interested in utilising the BF560-12s PSUPCB inside their own EN50131-6 compliant tamper-resistant enclosures should contact our marketing departmentfor further detailson costs and approvals.DATA PORTData on the BF560-12s status can be extracted from the PSUsbi-directional data port. The data availableincludes thermistor measurements battery terminal voltage system voltage at load terminals battery charge current load current battery impedanceandASCII text string status messages. Extracting this data requires additional equipment and permissions -call C-TEC for details.

GBP 113.64
1

C-Tec 24V 3A EN54-4 Switch Mode PSU BF562-3

C-Tec NC805AS Air Switch

C-Tec QT616 Quantec InfraredRadio Fall Sensor

C-Tec CP411T CAST-PRO CO Fire Smoke Heat Multisensor cw Tone Sounder

C-Tec CP414V CAST-PRO Smoke Heat Multisensor cw Voice Sounder

C-Tec CP414TVR CAST-PRO Smoke Heat Multisensor cw Tone Sounder amp O-C-1.9-4 Red VAD

C-Tec CP411TV CAST-PRO CO Fire Smoke Heat Multisensor cw Tone Sounder amp C-3-9.4 White VAD

C-Tec CP414TV CAST-PRO Smoke Heat Multisensor cw Tone Sounder amp C-3-9.4 White VAD

C-Tec CP411TVR CAST-PRO CO Fire Smoke Heat Multisensor cw Tone Sounder amp O-C-1.9-4 Red VAD

C-Tec CP411V CAST-PRO CO Fire Smoke Heat Multisensor cw Voice Sounder

C-Tec CP414VVR CAST-PRO Smoke Heat Multisensor cw Voice Sounder amp O-C-1.9-4 Red VAD

C-Tec CP414VV CAST-PRO Smoke Heat Multisensor cw Voice Sounder amp C-3-9.4 White VAD

C-Tec CFP702-4 2 Zone Conventional Fire Panel LPCB Approved

C-Tec CFP702-4 2 Zone Conventional Fire Panel LPCB Approved

C-Tec CFP 2 Zone Conventional Fire Panel LPCB Approved - CFP702-4LPCB certified to EN54-24 C-TECs CFP 2 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price. Supplied in an attractive flush or surface mountable plastic enclosure it includes two detector zones four conventional sounder circuits class change and alert inputs on-board fire and fault relays and combined keypadkey switch entry.A wide range of engineering functions are also provided including selectable zone delays coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided. Optional repeaters relay expansion boards and EN54-13 system compliance devices are also available.Key FeaturesThird-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board LPCB with optional EN54 part 13 compliance from the BSI.Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry.Manufactured by C-TEC in the UK.Two detector zone circuits.Four conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSU.Wide range of engineering functions including zone test coincidence zone delay and non-latching zones.Two on-board relays Fire and Fault.Two open-collector outputs Remote and Reset.Class change and alert inputs.Installer-friendly design.Attractive flush or surface mountable plastic lid and enclosure - no bezel required.Low 25mA quiescent current.Multiple indicators.System expansion connections provided for up to eight two-wire repeaters one CFP761 network card required per system optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.Space for two x 12V 3.3Ah VRLA batteries.Fully compatible with C-TECs ActiV range of conventional fire detectors.

GBP 130.25
1

C-Tec CFP 4 Zone Conventional Fire Panel LPCB Approved - CFP704-4

C-Tec CFP 4 Zone Conventional Fire Panel LPCB Approved - CFP704-4

C-Tec CFP 4 Zone Conventional Fire Panel LPCB Approved - CFP704-4LPCB certified to EN54-24 C-TECs CFP 4 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price. Supplied in an attractive flush or surface mountable plastic enclosure it includes two detector zones four conventional sounder circuits class change and alert inputs on-board fire and fault relays and combined keypadkey switch entry.A wide range of engineering functions are also provided including selectable zone delays coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided. Optional repeaters relay expansion boards and EN54-13 system compliance devices are also available.Key FeaturesThird-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board LPCB with optional EN54 part 13 compliance from the BSI.Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry.Manufactured by C-TEC in the UK.Two detector zone circuits.Four conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSU.Wide range of engineering functions including zone test coincidence zone delay and non-latching zones.Two on-board relays Fire and Fault.Two open-collector outputs Remote and Reset.Class change and alert inputs.Installer-friendly design.Attractive flush or surface mountable plastic lid and enclosure - no bezel required.Low 25mA quiescent current.Multiple indicators.System expansion connections provided for up to eight two-wire repeaters one CFP761 network card required per system optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.Space for two x 12V 3.3Ah VRLA batteries.Fully compatible with C-TECs ActiV range of conventional fire detectors.

GBP 148.46
1

C-Tec Output Expansion Relay Board EP212