23 results (0,20238 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

C-Tec BF367 Auxiliary Device Isolator single gang

C-Tec BF367 Auxiliary Device Isolator single gang

BF367 Auxiliary Device Isolator single gangThe BF367 allows a 24V d.c. output from a fire alarm control panel to be remotely isolated to prevent external equipment such as auto diallers roller shutter doors etc from operating. This is a particularly useful function during routine test and maintenance as it safeguards against the inadvertent and potentially hazardous triggering of auxiliary equipment.To aid location the BF367s front label has a white write on panel allowing installers to add their own personalised text such as equipment locations. The unit will fit on 25mm deep flush or surface mount back boxes.Key FeaturesThe BF367 incorporates an isolating key switch and a high intensity amber LEDThe switch circuit has been designed so that if monitoring is used on the 24V d.c. output being controlled a fault condition will show at the fire panel when the BF367s key switch is in the ISOLATED position note that the key can be removed from the key switch in both the ON and ISOLATED positionsThe units amber LED can also be set-up to illuminate when the key switch is in the ISOLATED position provided sufficient voltage is presentAllows a 24 VDC output from a fire alarm control panel to be remotely isolated to prevent autodiallers water sprinklers rollershutters etc. from activatingDesigned so that if monitoring is used on the 24 VDC output being controlled a fault condition will show at the fire panel when the device is IsolatedLabel includes a white write on area allowing installers to add equipment locationsFits on standard UK 25mm flush or surface mount back boxes

GBP 21.18
1

C-Tec CA431AW CA Base Sounder White

C-Tec CA432AW CA O Class Base Sounder VAD - White

C-Tec BF340CTSR 24V Loop VID Shallow Base Red

C-Tec NC806C Conventional Overdoor Light

C-Tec NC807C Conventional Ceiling Pull Cord

C-Tec NC894DKB Conventional Isolatable Monitoring Point with Button Reset and Door Contacts

C-Tec NC806CS Conventional Overdoor Light amp Sounder

C-Tec NC809DBBT Conventional Accessible Toilet Reset Point with Sounder

C-Tec BF456CCCW ActiV Conventional Base Sounder VAD C-3-8.5

C-Tec BF456CCCW ActiV Conventional Base Sounder VAD C-3-8.5

C-Tec BF456CCCW ActiV Conventional Base Sounder VAD C-3-8.5The ActiV Base Mount range of conventional sounders and combined sounder visual alarm devices VADs are designed for use with C-TECs range of fire panels and other compatible third-party panels. However compatibility testing with third-party panels is recommended to ensure correct operation. Their purpose is to visually and audibly alert building occupants of a fire alarm.The BF456CCCW base sounder VAD offer low current consumption high sound output high efficiency VADs 31 selectable primary tones with selectable secondary tone set two selectable volume levels and three selectable VAD flash rates. Tones volume levels and VAD flash rates are changed using the bases 8-way DIP switch.All bases can be optionally used as eithera stand-alone base device using a separately available locking white cap BF330CTLIDW red cap BF330CTLIDR ora combined base device and detector detectors are separately available and wired on a separate detection circuit. The base devices are compatible with C-TECs range of ActiV conventional detectors and other compatible third-party suppliers.Key FeaturesThird-party certified to EN54-3 SoundersandEN54-23 VADsProvides C-3-8.5 light distribution min 0.4 lux over a 3 x 8.5m cylindrical areaImpressive 96dBA sound output 1m31 selectable primary andsecondary tone pairs and two volume levels high and lowThree selectable VAD flash rates 0.5Hz 1Hz OFFAlarm Current at 30Vdc 12.2mA 0.5Hz or 19.5mA 1HzAlarm Current at 18Vdc 14.5mA 0.5Hz or 25mA 1HzOptional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone useSupplied with a BF431QCP quick connect plate and detector spur wiresIP21C rated

GBP 39.78
1

C-Tec BF432CCCW ActiV Conventional Base Sounder VAD O-R-3-2.5-17

C-Tec BF432CCCW ActiV Conventional Base Sounder VAD O-R-3-2.5-17

C-Tec BF432CCCW ActiV Conventional Base Sounder VAD O-R-3-2.5-17The ActiV Base Mount range of conventional sounders and combined sounder visual alarm devices VADs are designed for use with C-TECs range of fire panels and other compatible third-party panels. However compatibility testing with third-party panels is recommended to ensure correct operation. Their purpose is to visually and audibly alert building occupants of a fire alarm.The bases offer low current consumption high sound output high efficiency VADs 31 selectable primary tones with selectable secondary tone set two selectable volume levels and three selectable VAD flash rates. Tones volume levels and VAD flash rates are changed using the bases 8-way DIP switch.All bases can be optionally used as eithera stand-alone base device using a separately available locking white cap BF330CTLIDW red cap BF330CTLIDR ora combined base device and detector detectors are separately available and wired on a separate detection circuit. The base devices are compatible with C-TECs range of ActiV conventional detectors and other compatible third-party suppliers.Key FeaturesThird-party certified to EN54-3 SoundersandEN54-23 VADsProvides O-R-3-2.5-17 light distributionIdeally suited for use in corridors and other rectangular areasImpressive 96dBA sound output 1m31 selectable primary andsecondary tone pairs and two volume levels high and lowThree selectable VAD flash rates 0.5Hz 1Hz OFFAlarm Current at 30Vdc 12.2mA 0.5Hz or 19.5mA 1HzAlarm Current at 18Vdc 14.5mA 0.5Hz or 25mA 1HzOptional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone useSupplied with a BF431QCP quick connect plate and detector spur wiresIP21C rated

GBP 39.78
1

C-Tec CFP EN54-13 Sounder Circuit Fault Monitoring Module BF355

C-Tec BF458ACXSW Addressable Ceiling VAD

C-Tec BF458ACXSW Addressable Ceiling VAD

C-Tec BF458ACXSW Addressable Ceiling VADThe C-TEC BF458ACXSW is a compact addressable loop-powered wall VAD in white. It provides W-3-3.1 light distribution when wall mounted min 0.4 lux over a 3 x 8m cylindrical area or it can also provide C-3-8 light distribution when ceiling mounted min 0.4 lux over a 2.4 x 3.5m cuboid area. It is compatible with XP95Discovery protocol systems and designed for use with C-TECs XFP and ZFP fire panels.The Compact range of addressable loop powered devices include sounders visual alarm devices VADs and combined sounder VADs. They are designed for indoor use with C-TECs ZFPXFP and other Apollo Discovery compatible fire panels.Their purpose is to visually and audibly alert building occupants of a fire alarm. The devices offer low current consumption high sound output high efficiency VADs seven selectable volume levels 15 selectable tone pairs and built-in short-circuit loop isolators.The sounder and VAD on the combined device can be set to operate independently of each other panel dependent function.All devices are fully compliant with the relevant sections of the fire alarm device standards EN 54-3 Sounders EN 54-23 Visual alarm devices - VADs and EN 54-17 Short-circuit isolators.Key FeaturesThird-party certified to EN54-23 VADs and 17 Isolators by IntertekProvides C-3-8 light distribution when ceiling mounted min 0.4 lux over a 3 x 8m cylindrical areaCan also provide W-3-3.1 light distribution when wall mounted min. 0.4 lux over a 2.4 x 3.5m cuboid areaOnboard short-circuit loop isolator550A quiescent current10mA alarm current 24V DCGroup addressing facility allows multiple devices to be operated simultaneouslyIP21C rated

GBP 43.06
1

C-Tec STI-6930G STI Call Point Stopper - Green - Flush

C-Tec STI-6931G STI Call Point Stopper - Green - Surface

C-Tec BF440CF1 FUL Solista LX 24V Wall VAD Red Body - Red Flash Shallow Base

C-Tec BF440CF1 FUL Solista LX 24V Wall VAD Red Body - Red Flash Shallow Base

C-Tec BF440CF1 FUL Solista LX 24V Wall VAD Red Body - Red Flash Shallow BaseThe Solista LX visual alarm device VAD is an EN54-23 rated fire alarm beacon. Achieved through its unique lens design which distributes light in a highly controlled pattern it achieves the required illumination specific by EN54-23 while drawing a low current consumption.Taking its design principles from the popular Solista Maxi the Solista LX is compact and slim blending in when its not required and standing out when it is. Now in its second generation it features soft-start technology enabling the maximum product loading and protection against overloading and fault.The patented long life LED lens optics used in the LX have been developed specifically for the VAD EN54-23 standard.It uses modern thick-mould injection moulding techniques and innovative cylindrical output to achieve the correct level of illumination while keeping power consumption as low as possible.The 2nd generation of the LX now incorporates soft-start technology. This innovative feature constantly monitors the available voltage to give zero start up surge on the line allowing maximum product loading. It can also detect line overloading and will indicate the fault with a rapid double flash.Key FeaturesCertified to EN54 Parts 23 AFNOR and 13 BSIProvides W-2.4-7.5 coverage switchable to W-2.4-2.5 if required10-25mA alarm current depending on settingAttractive slim designUltra-bright red LEDIdeal for use in bedrooms bathrooms and toilets

GBP 36.13
1

C-Tec QT603 Quantec Network Splitter

C-Tec QT603 Quantec Network Splitter

C-Tec QT603 Quantec Network SplitterQuantec utilises a unique data protocol that works down two wires andamaximum of 255 addressable devices can be connected to a Quantec Controller dependent on network topology.Addressable devices require 2 network connections. Slave devices such as slave ceiling pullsandslave overdoor lights connect to Quantec via a master call point master ceiling receiver monitoring point or universal programming device using 2 3 or 4 cores of stranded security cable.Wiring must bemade in a Spine and Limb configuration using one or more QT603 network splitters. This allowsthe use of ordinary unscreened cable which simplifies installation fault-finding and commissioning.Key FeaturesAn essential wiringinstallation aid for C-TECsQuantec Addressable Call System.Helps protect against open and short circuit faults and reduces the risk of volt drop.Includes one input and one output connection for Quantecs Spine wiring typically 1.5-2.5mm TE and sixfused 400mA limb connections for the wiring of individual circuits containing Quantecs fielddevices typically 4 core stranded security cable.At least one QT603 is required perQuantec system the more you use the easier it will beto program and fault-find.Install one QT603 per corridor junction locate at the end of the corridor nearest to the Quantec Controller.Ifthe corridor is longer than 50m install the splitter in the centre of the corridor to reduce wiring runs.Mounts on a standard 25mm UK double gang back box.Power and Fault indicators.Max.60 addressable devices per QT603.

GBP 29.40
1

C-Tec BF460ACXW Addressable Base VAD C-3-8

C-Tec BF460ACXW Addressable Base VAD C-3-8

C-Tec BF460ACXW Addressable Base VAD C-3-8The C-Tec BF460ACXW is an addressable VAD beacon base which is ideal for use with the Apollo protocol range of C-Tec XFP and ZFP fire alarm control panels.The Base Mount range of addressable loop-powered bases includes sounders visual alarm devices VADs and combined sounder VADs. They are designed for use with C-TECs ZFPXFP panels and other Apollo Discovery compatible fire panels.Their purpose is to visually and audibly alert building occupants of a fire alarm.All bases can be optionally used as eithera stand-alone base using a separately available locking white cap BF330CTLIDW red cap BF330CTLIDR ora combined base and Apollo detector Apollo detectors are separately available.The bases offer low current consumption high sound output high efficiency VADs seven selectable volume levels 15 selectable tone pairs and built-in short-circuit loop isolators. The combined sounder and VAD on the BF432ACXW and BF456ACXW bases can be set to operate independently of each other panel dependent function.All bases excluding BF432ACXW and BF459ACXW are fully certified with all relevant sections of the fire alarm device standards EN 54-3 Sounders EN 54-23 Visual alarm devices - VADs and EN 54-17 Short-circuit isolators.Key FeaturesProvides C-3-8 light distribution min 0.4 lux over a 3 x 8m cylindrical areaSupplied with a BF431QCP quick connect plate and detector spur wiresOnboard short-circuit loop isolator550A quiescent current10mA alarm current 24V DCGroup addressing facility allows multiple devices to be operated simultaneouslyOptional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone useIP21C rated

GBP 33.95
1