19 results (0,13211 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

C-Tec NC944SS Four Zone Call Controller in Stainless Steel

C-Tec QT601-2 Quantec Controller

C-Tec QT601-2 Quantec Controller

C-Tec QT601-2 Quantec ControllerQuantec is a powerful yet easy to use addressable call system that helps ensure vital communication throughout a building. In environments where efficiency is paramount Quantec delivers helping save staff time minimising disturbance and improving the quality of patient customer or employee care. Whatever the application - be it a call system for a nursing home hospital hotel or leisure centre or a staff protection system for a high dependency unit prison factory shop school or council office - Quantec is the obvious choice.With its flexible call routing multiple call levels a unique data protocol that works down just two wires and a laptop programmable system controller Quantec can be tailored to suit the exact operational needs of any building. For example calls can be routed to different parts of a site at different times of the day and unanswered calls can be set to transfer to other areas after a pre-determined time. As well as a huge range of cost-effective call points ceiling pulls displays monitoring points sounders neck pendants and infrared transmitters the system includes a host of industry-leading features.The controller supplies power to and controls a Quantec Addressable Call System. Monitors all network devices and manages the routing and distribution of all calls. Provides connections for network wiring standby batteries a laptop for system programmingoptionalpagingDECT equipment anoptionalprinter orPC to run Quantecs QT707S Surveyor data management software.Key FeaturesIncludes a library of 40 pre-set 45 custom place names.System setup requires a laptop PC running Quantecs QT707 programming tools.Can be semi-flush mounted using an QT385 bezel or fully-flushed using a BF3593S stainless steel enclosure.System wiring requires one or more QT603 network splitters.Wiring should be made in a spine and limb arrangement using 1.5 to 2.5mm2 TE spines and 4 to 8 core stranded security cable limbs.

GBP 426.65
1

C-Tec NC910F Conventional 10 Zone Flush Master Call Controller

C-Tec NC910F Conventional 10 Zone Flush Master Call Controller

C-Tec NC910F Conventional 10 Zone Flush Master Call ControllerThe NC910FCall Controller is compatible with all 800 Series call points ceiling pulls infrared ceiling receivers monitoring points overdoor lights and remote sounders.Depending on how the Controller is configured and the devices connected to it Standard and Emergency calls can be indicated via its buzzer and zonal LEDs. Two buttons A and B are also provided to allow the user to Reset Mute or Accept standard calls as detailed below.Standard Calls when triggered by a calling device the Controllers internal buzzer sounds continuously and the relevant zone indicators illuminate steady.Pressing the Controllers Reset Button A if enabled cancels all standard calls.Pressing the Controllers Mute Button B if enabled silences the Controllers internal buzzer. However if a new call standard or emergency is triggered anywhere on the system the buzzer will resound.Alternatively instead of muting calls Button B can be configured as a CALL ACCEPT button.Pressing Call Accept sends a slow pulsing acknowledgement signal to overdoor lights and reset points cw sounders provided they are wired as shown on the example wiring diagram below. Should a new call standard or emergency be triggered anywhere on the system any zones in the acknowledgement state will revert to a standard call.Emergency Calls when triggered by a calling device the Controllers internal buzzer pulses and the relevant zone indicators flash. This level of call takes priority over standard calls and cannot be muted accepted or reset at the Controller. An emergency call can only be reset at the device from which it was triggered or via a reset point wired on the same zone.Key FeaturesCompatible with C-TECs entire range of 800 Series field devicesHoused in an attractive flush mounting plastic enclosure measuring just 214mm x 178mmTwo call levels - standard constant tone and emergency intermittent toneOptional mute and call acceptreset buttonsCall Accept functionality allows staff to send an intermittent call acknowledgment signal to calling zones to confirm help is on the way dependent on wiring and field devices usedIncludes a 12V 300mA PSU and 2 volt-free relay contacts which activate on a standard or emergency callInnovative slide-in labelling systemZones can be wired in 4 or 6 core 702 stranded security cableAdditional master controllers and expansion units available for use as repeaters on larger sitesOptional boxed PSUs cw with space for a 12V VRLA battery available for sites where a standby battery facility is required

GBP 228.82
1

C-Tec NC920F Conventional 20 Zone Flush Master Call Controller

C-Tec NC920F Conventional 20 Zone Flush Master Call Controller

C-Tec NC920F Conventional 20 Zone Flush Master Call ControllerThe NC920FCall Controller is compatible with all 800 Series call points ceiling pulls infrared ceiling receivers monitoring points overdoor lights and remote sounders.Depending on how the Controller is configured and the devices connected to it Standard and Emergency calls can be indicated via its buzzer and zonal LEDs. Two buttons A and B are also provided to allow the user to Reset Mute or Accept standard calls as detailed below.Standard Calls when triggered by a calling device the Controllers internal buzzer sounds continuously and the relevant zone indicators illuminate steady.Pressing the Controllers Reset Button A if enabled cancels all standard calls.Pressing the Controllers Mute Button B if enabled silences the Controllers internal buzzer. However if a new call standard or emergency is triggered anywhere on the system the buzzer will resound.Alternatively instead of muting calls Button B can be configured as a CALL ACCEPT button.Pressing Call Accept sends a slow pulsing acknowledgement signal to overdoor lights and reset points cw sounders provided they are wired as shown on the example wiring diagram below. Should a new call standard or emergency be triggered anywhere on the system any zones in the acknowledgement state will revert to a standard call.Emergency Calls when triggered by a calling device the Controllers internal buzzer pulses and the relevant zone indicators flash. This level of call takes priority over standard calls and cannot be muted accepted or reset at the Controller. An emergency call can only be reset at the device from which it was triggered or via a reset point wired on the same zone.Key FeaturesCompatible with C-TECs entire range of 800 Series field devicesHoused in an attractive flush mounting plastic enclosure measuring just 214mm x 178mmTwo call levels - standard constant tone and emergency intermittent toneOptional mute and call acceptreset buttonsCall Accept functionality allows staff to send an intermittent call acknowledgment signal to calling zones to confirm help is on the way dependent on wiring and field devices usedIncludes a 12V 300mA PSU and 2 volt-free relay contacts which activate on a standard or emergency callInnovative slide-in labelling systemZones can be wired in 4 or 6 core 702 stranded security cableAdditional master controllers and expansion units available for use as repeaters on larger sitesOptional boxed PSUs cw with space for a 12V VRLA battery available for sites where a standby battery facility is required

GBP 309.20
1

C-Tec NC920S Conventional 20 Zone Surface Master Call Controller

C-Tec NC920S Conventional 20 Zone Surface Master Call Controller

C-Tec NC920S Conventional 20 Zone Surface Master Call ControllerThe NC920S Call Controller is compatible with all 800 Series call points ceiling pulls infrared ceiling receivers monitoring points overdoor lights and remote sounders.Depending on how the Controller is configured and the devices connected to it Standard and Emergency calls can be indicated via its buzzer and zonal LEDs. Two buttons A and B are also provided to allow the user to Reset Mute or Accept standard calls as detailed below.Standard Calls when triggered by a calling device the Controllers internal buzzer sounds continuously and the relevant zone indicators illuminate steady.Pressing the Controllers Reset Button A if enabled cancels all standard calls.Pressing the Controllers Mute Button B if enabled silences the Controllers internal buzzer. However if a new call standard or emergency is triggered anywhere on the system the buzzer will resound.Alternatively instead of muting calls Button B can be configured as a CALL ACCEPT button.Pressing Call Accept sends a slow pulsing acknowledgement signal to overdoor lights and reset points cw sounders provided they are wired as shown on the example wiring diagram below. Should a new call standard or emergency be triggered anywhere on the system any zones in the acknowledgement state will revert to a standard call.Emergency Calls when triggered by a calling device the Controllers internal buzzer pulses and the relevant zone indicators flash. This level of call takes priority over standard calls and cannot be muted accepted or reset at the Controller. An emergency call can only be reset at the device from which it was triggered or via a reset point wired on the same zone.Key FeaturesCompatible with C-TECs entire range of 800 Series field devicesHoused in an attractive surface mounting plastic enclosure measuring just 214mm x 178mmTwo call levels - standard constant tone and emergency intermittent toneOptional mute and call acceptreset buttonsCall Accept functionality allows staff to send an intermittent call acknowledgment signal to calling zones to confirm help is on the way dependent on wiring and field devices usedIncludes a 12V 300mA PSU and 2 volt-free relay contacts which activate on a standard or emergency callInnovative slide-in labelling systemZones can be wired in 4 or 6 core 702 stranded security cableAdditional master controllers and expansion units available for use as repeaters on larger sitesOptional boxed PSUs cw with space for a 12V VRLA battery available for sites where a standby battery facility is required

GBP 315.38
1

C-Tec NC910S Conventional 10 Zone Surface Master Call Controller

C-Tec NC910S Conventional 10 Zone Surface Master Call Controller

C-Tec NC910S Conventional 10 Zone Surface Master Call ControllerThe NC910S Call Controller is compatible with all 800 Series call points ceiling pulls infrared ceiling receivers monitoring points overdoor lights and remote sounders.Depending on how the Controller is configured and the devices connected to it Standard and Emergency calls can be indicated via its buzzer and zonal LEDs. Two buttons A and B are also provided to allow the user to Reset Mute or Accept standard calls as detailed below.Standard Calls when triggered by a calling device the Controllers internal buzzer sounds continuously and the relevant zone indicators illuminate steady.Pressing the Controllers Reset Button A if enabled cancels all standard calls.Pressing the Controllers Mute Button B if enabled silences the Controllers internal buzzer. However if a new call standard or emergency is triggered anywhere on the system the buzzer will resound.Alternatively instead of muting calls Button B can be configured as a CALL ACCEPT button.Pressing Call Accept sends a slow pulsing acknowledgement signal to overdoor lights and reset points cw sounders provided they are wired as shown on the example wiring diagram below. Should a new call standard or emergency be triggered anywhere on the system any zones in the acknowledgement state will revert to a standard call.Emergency Calls when triggered by a calling device the Controllers internal buzzer pulses and the relevant zone indicators flash. This level of call takes priority over standard calls and cannot be muted accepted or reset at the Controller. An emergency call can only be reset at the device from which it was triggered or via a reset point wired on the same zone.Key FeaturesCompatible with C-TECs entire range of 800 Series field devicesHoused in an attractive surface mounting plastic enclosure measuring just 214mm x 178mmTwo call levels - standard constant tone and emergency intermittent toneOptional mute and call acceptreset buttonsCall Accept functionality allows staff to send an intermittent call acknowledgment signal to calling zones to confirm help is on the way dependent on wiring and field devices usedIncludes a 12V 300mA PSU and 2 volt-free relay contacts which activate on a standard or emergency callInnovative slide-in labelling systemZones can be wired in 4 or 6 core 702 stranded security cableAdditional master controllers and expansion units available for use as repeaters on larger sitesOptional boxed PSUs cw with space for a 12V VRLA battery available for sites where a standby battery facility is required

GBP 234.98
1

C-Tec QT630 Quantec Dimentia Care Master Controller

C-Tec NC910EF 10 Zone Expansion Unit for NC910F or NC920F

C-Tec NC920EF 20 Zone Expansion Unit for NC910F or NC920F

C-Tec NC920ES 20 Zone Expansion Unit for NC910S or NC920S

C-Tec NC910ES 10 Zone Expansion Unit for NC910S or NC920S

C-Tec EVC301RLK Type A Red Key Lockable Telephone Outstation with Handset

C-Tec HAK1 HUSH-ACTIV BS 5839-6 Grade C Stand-Alone Domestic Fire Alarm Kit

C-Tec EVC302GF Type B Green Handsfree EVC Flush Outstation

C-Tec EVC302GS Type B Green Handsfree EVC Surface Outstation

C-Tec EVC302F Type B Stainless Steel Handsfree EVC Flush Outstation

C-Tec EVC302S Type B Stainless Steel Handsfree EVC Surface Outstation

C-Tec NC951SS Conventional Stainless-Steel Emergency Assistance Alarm Kit