19 results (0,14545 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

C-Tec QT609SSS Quantec Stainless Steel Call Point - Button Reset with Sounder Single Gang

C-Tec BF877QAQS 40 Character Alpha Pocket Pager - Vibrate

C-Tec QT608CD Quantec Corridor Display with No Controls

C-Tec QT608CDSS Quantec Stainless Steel Corridor Display with No Controls

C-Tec QT602KSSS Quantec Stainless Steel Call Point - Key Reset with Sounder

C-Tec QT608C Quantec Corridor Display with Controls

C-Tec QT608CSS Quantec Stainless Steel Corridor Display with Controls

C-TEC XFP501ECA XFP 1 Loop 16 Zone Panel C-TEC CAST. Max. 2 x 3.2Ah Batteries

C-TEC XFP501ECA XFP 1 Loop 16 Zone Panel C-TEC CAST. Max. 2 x 3.2Ah Batteries

C-TEC XFP501ECA XFP 1 Loop 16 Zone Panel C-TEC CAST. Max. 2 x 3.2Ah BatteriesC-TECs tried and trusted XFP oneloop 16zoneaddressable fire alarm panel - now available with C-TECs own digital fire alarm system protocol CAST and fully certified to EN54 parts 2 4 and 13.With a powerful 40V 500mA loop driver allowing the connection of up to 255 CAST devices the installation of a cost-effective feature-packed addressable fire alarm system has never been easier.Always thought of the XFP as an entry-level fire panel Think again. Thanks to CASTs multiple type codes high speed data transmission and two speedy soft addressing options automatic via the panel or manually via a handheld programmerdevice tester it is undoubtedly one of the most powerful single loop fire panels around. This and its ability to sit on a network of up to 8 XFP master panels makes it ideal for use in small to medium sized stand-alone applications and larger more sophisticated installations alike.Protocol FeaturesCAST is the worlds most-advanced distributed intelligence fire alarm system protocol. Conceived designed and realised by C-TEC as part of a five-year multi-million pound project it involved the creation of a powerful proprietary communication protocol C-TEC Addressable System Technology CAST and multiple control panels field devices. Now available to purchase.Key Features 255 devices per loop. Autonomous decision-making for faster response times. Multiple type codes. 40V loop drive voltage. Two soft addressing options automatic via the panel or manual via a powerful handheld programmer. Powerful multi-level addressing facilitates easy device addition and swapped device identification. Multiple functionality at a single address integrated devices - due 2021. Volumes tones detector modes can be changed at compatible panels. High-speed data transmission and robust data transfer. Provides geographical location of short and open circuit faults a short circuit isolator is included as standard in every CAST field device. Replace device function. Programmable multi-function status LED. Future seamless integration with other CAST life safety systems reducing energy servicing installation and repair costs. ENVISION Enabled - fully compliant with our new ENVISION Cloud-based Fire IoT Remote Access System Test and Site Management software package. Designed and manufactured in the UK.Panel Features Certifiedto EN54-24 by the Loss Prevention Certification Board LPCB and EN54-13 by Kiwa Telefication. Two independently programmable conventional sounder circuits. Two programmable inputs. A fault output relay and three programmable relay outputs with voltage free changeover contacts. A selection of zone dependencycoincidence functions. A daynight building occupiedunoccupied function. An investigation delay period function. Phased evacuation facility. An alarm counter that records how many times the panel has been in alarm state. Powerful short circuit protected loop drivers. An integral EN54-4A2 switch mode. Adjustable contamination levels. Earth fault monitoring. Combined keypad keyswitch entry to Access Levels 2 and 3. 500 event monitoring. An intuitive Windows based upload-download PC program. Up to eight XFP main panels any variant can be connected onto a two-wire RS485 non-redundantnetwork. Alternatively up to eight XFP repeaters can be connected to any non-networked main panel.Cast Commissioning Services available with this Equipment

GBP 381.44
1

C-Tec NC910S Conventional 10 Zone Surface Master Call Controller

C-Tec NC910S Conventional 10 Zone Surface Master Call Controller

C-Tec NC910S Conventional 10 Zone Surface Master Call ControllerThe NC910S Call Controller is compatible with all 800 Series call points ceiling pulls infrared ceiling receivers monitoring points overdoor lights and remote sounders.Depending on how the Controller is configured and the devices connected to it Standard and Emergency calls can be indicated via its buzzer and zonal LEDs. Two buttons A and B are also provided to allow the user to Reset Mute or Accept standard calls as detailed below.Standard Calls when triggered by a calling device the Controllers internal buzzer sounds continuously and the relevant zone indicators illuminate steady.Pressing the Controllers Reset Button A if enabled cancels all standard calls.Pressing the Controllers Mute Button B if enabled silences the Controllers internal buzzer. However if a new call standard or emergency is triggered anywhere on the system the buzzer will resound.Alternatively instead of muting calls Button B can be configured as a CALL ACCEPT button.Pressing Call Accept sends a slow pulsing acknowledgement signal to overdoor lights and reset points cw sounders provided they are wired as shown on the example wiring diagram below. Should a new call standard or emergency be triggered anywhere on the system any zones in the acknowledgement state will revert to a standard call.Emergency Calls when triggered by a calling device the Controllers internal buzzer pulses and the relevant zone indicators flash. This level of call takes priority over standard calls and cannot be muted accepted or reset at the Controller. An emergency call can only be reset at the device from which it was triggered or via a reset point wired on the same zone.Key FeaturesCompatible with C-TECs entire range of 800 Series field devicesHoused in an attractive surface mounting plastic enclosure measuring just 214mm x 178mmTwo call levels - standard constant tone and emergency intermittent toneOptional mute and call acceptreset buttonsCall Accept functionality allows staff to send an intermittent call acknowledgment signal to calling zones to confirm help is on the way dependent on wiring and field devices usedIncludes a 12V 300mA PSU and 2 volt-free relay contacts which activate on a standard or emergency callInnovative slide-in labelling systemZones can be wired in 4 or 6 core 702 stranded security cableAdditional master controllers and expansion units available for use as repeaters on larger sitesOptional boxed PSUs cw with space for a 12V VRLA battery available for sites where a standby battery facility is required

GBP 234.98
1

C-Tec NC910F Conventional 10 Zone Flush Master Call Controller

C-Tec NC910F Conventional 10 Zone Flush Master Call Controller

C-Tec NC910F Conventional 10 Zone Flush Master Call ControllerThe NC910FCall Controller is compatible with all 800 Series call points ceiling pulls infrared ceiling receivers monitoring points overdoor lights and remote sounders.Depending on how the Controller is configured and the devices connected to it Standard and Emergency calls can be indicated via its buzzer and zonal LEDs. Two buttons A and B are also provided to allow the user to Reset Mute or Accept standard calls as detailed below.Standard Calls when triggered by a calling device the Controllers internal buzzer sounds continuously and the relevant zone indicators illuminate steady.Pressing the Controllers Reset Button A if enabled cancels all standard calls.Pressing the Controllers Mute Button B if enabled silences the Controllers internal buzzer. However if a new call standard or emergency is triggered anywhere on the system the buzzer will resound.Alternatively instead of muting calls Button B can be configured as a CALL ACCEPT button.Pressing Call Accept sends a slow pulsing acknowledgement signal to overdoor lights and reset points cw sounders provided they are wired as shown on the example wiring diagram below. Should a new call standard or emergency be triggered anywhere on the system any zones in the acknowledgement state will revert to a standard call.Emergency Calls when triggered by a calling device the Controllers internal buzzer pulses and the relevant zone indicators flash. This level of call takes priority over standard calls and cannot be muted accepted or reset at the Controller. An emergency call can only be reset at the device from which it was triggered or via a reset point wired on the same zone.Key FeaturesCompatible with C-TECs entire range of 800 Series field devicesHoused in an attractive flush mounting plastic enclosure measuring just 214mm x 178mmTwo call levels - standard constant tone and emergency intermittent toneOptional mute and call acceptreset buttonsCall Accept functionality allows staff to send an intermittent call acknowledgment signal to calling zones to confirm help is on the way dependent on wiring and field devices usedIncludes a 12V 300mA PSU and 2 volt-free relay contacts which activate on a standard or emergency callInnovative slide-in labelling systemZones can be wired in 4 or 6 core 702 stranded security cableAdditional master controllers and expansion units available for use as repeaters on larger sitesOptional boxed PSUs cw with space for a 12V VRLA battery available for sites where a standby battery facility is required

GBP 228.82
1

C-Tec NC920F Conventional 20 Zone Flush Master Call Controller

C-Tec NC920F Conventional 20 Zone Flush Master Call Controller

C-Tec NC920F Conventional 20 Zone Flush Master Call ControllerThe NC920FCall Controller is compatible with all 800 Series call points ceiling pulls infrared ceiling receivers monitoring points overdoor lights and remote sounders.Depending on how the Controller is configured and the devices connected to it Standard and Emergency calls can be indicated via its buzzer and zonal LEDs. Two buttons A and B are also provided to allow the user to Reset Mute or Accept standard calls as detailed below.Standard Calls when triggered by a calling device the Controllers internal buzzer sounds continuously and the relevant zone indicators illuminate steady.Pressing the Controllers Reset Button A if enabled cancels all standard calls.Pressing the Controllers Mute Button B if enabled silences the Controllers internal buzzer. However if a new call standard or emergency is triggered anywhere on the system the buzzer will resound.Alternatively instead of muting calls Button B can be configured as a CALL ACCEPT button.Pressing Call Accept sends a slow pulsing acknowledgement signal to overdoor lights and reset points cw sounders provided they are wired as shown on the example wiring diagram below. Should a new call standard or emergency be triggered anywhere on the system any zones in the acknowledgement state will revert to a standard call.Emergency Calls when triggered by a calling device the Controllers internal buzzer pulses and the relevant zone indicators flash. This level of call takes priority over standard calls and cannot be muted accepted or reset at the Controller. An emergency call can only be reset at the device from which it was triggered or via a reset point wired on the same zone.Key FeaturesCompatible with C-TECs entire range of 800 Series field devicesHoused in an attractive flush mounting plastic enclosure measuring just 214mm x 178mmTwo call levels - standard constant tone and emergency intermittent toneOptional mute and call acceptreset buttonsCall Accept functionality allows staff to send an intermittent call acknowledgment signal to calling zones to confirm help is on the way dependent on wiring and field devices usedIncludes a 12V 300mA PSU and 2 volt-free relay contacts which activate on a standard or emergency callInnovative slide-in labelling systemZones can be wired in 4 or 6 core 702 stranded security cableAdditional master controllers and expansion units available for use as repeaters on larger sitesOptional boxed PSUs cw with space for a 12V VRLA battery available for sites where a standby battery facility is required

GBP 309.20
1

C-Tec NC920S Conventional 20 Zone Surface Master Call Controller

C-Tec NC920S Conventional 20 Zone Surface Master Call Controller

C-Tec NC920S Conventional 20 Zone Surface Master Call ControllerThe NC920S Call Controller is compatible with all 800 Series call points ceiling pulls infrared ceiling receivers monitoring points overdoor lights and remote sounders.Depending on how the Controller is configured and the devices connected to it Standard and Emergency calls can be indicated via its buzzer and zonal LEDs. Two buttons A and B are also provided to allow the user to Reset Mute or Accept standard calls as detailed below.Standard Calls when triggered by a calling device the Controllers internal buzzer sounds continuously and the relevant zone indicators illuminate steady.Pressing the Controllers Reset Button A if enabled cancels all standard calls.Pressing the Controllers Mute Button B if enabled silences the Controllers internal buzzer. However if a new call standard or emergency is triggered anywhere on the system the buzzer will resound.Alternatively instead of muting calls Button B can be configured as a CALL ACCEPT button.Pressing Call Accept sends a slow pulsing acknowledgement signal to overdoor lights and reset points cw sounders provided they are wired as shown on the example wiring diagram below. Should a new call standard or emergency be triggered anywhere on the system any zones in the acknowledgement state will revert to a standard call.Emergency Calls when triggered by a calling device the Controllers internal buzzer pulses and the relevant zone indicators flash. This level of call takes priority over standard calls and cannot be muted accepted or reset at the Controller. An emergency call can only be reset at the device from which it was triggered or via a reset point wired on the same zone.Key FeaturesCompatible with C-TECs entire range of 800 Series field devicesHoused in an attractive surface mounting plastic enclosure measuring just 214mm x 178mmTwo call levels - standard constant tone and emergency intermittent toneOptional mute and call acceptreset buttonsCall Accept functionality allows staff to send an intermittent call acknowledgment signal to calling zones to confirm help is on the way dependent on wiring and field devices usedIncludes a 12V 300mA PSU and 2 volt-free relay contacts which activate on a standard or emergency callInnovative slide-in labelling systemZones can be wired in 4 or 6 core 702 stranded security cableAdditional master controllers and expansion units available for use as repeaters on larger sitesOptional boxed PSUs cw with space for a 12V VRLA battery available for sites where a standby battery facility is required

GBP 315.38
1

C-Tec 24V 5A EN54-4 Switch Mode PSU BF562-5

C-Tec CP414BTV CAST-PRO Smoke Heat Multisensor cw Tone Sounder amp C-3-9.4 White VAD Black Housing

C-Tec CP411VVR CAST-PRO CO Fire Smoke Heat Multisensor cw Voice Sounder amp O-C-1.9-4 Red VAD

C-Tec CP411VV CAST-PRO CO Fire Smoke Heat Multisensor cw Voice Sounder amp C-3-9.4 White VAD

C-Tec CA737 EACIE 4 Way Flat Interface No PSU In Cabinet Extendable To 8 Way

C-Tec ENVS64-1 ENVISION FIRE IOT Software Licence 5-64 Panel Network - 1 YEAR

C-Tec ENVS64-1 ENVISION FIRE IOT Software Licence 5-64 Panel Network - 1 YEAR

C-Tec ENVS64-1 ENVISION FIRE IOT Software Licence 5-64 Panel Network - 1 YEARENVISION software licence for use with ENV-HUB 5-64 panel network.About ENVISION softwareENVISION is a Cloud based remote access service test and data management software package from C-TEC.Add an ENVISION IoT Gateway Hub order code ENV-HUB to your C-TEC CAST protocol fire detection and alarm systems to unlock a host of powerful features that are perfect for installers end users duty holders site managers responsible persons and more.Want to check the status of a CAST system from a remote location Not a problem Wherever you are in the world ENVISION allows you to generate powerful site-specific reports that can be scheduled to arrive on your desktop daily weekly or monthly to help demonstrate due diligence via a verifiable audit trail.Want fires faults tests and other system notifications to be sent in real time to a PC tablet or smart phone Job done Theres even a powerful graphics module that allows you to monitor the progress of a fire as it happens on a user- uploaded site map or building plan.Want evidence that a clients weekly BS 5839-1 user tests are being carried out Its all there at the touch of button.ENVISION really comes into its own if youre an installer or a service and maintenance company. Not only does it allow authorised personnel to interrogate a CAST system prior to visiting site to determine if there are any contaminated devices or other issues ENVISIONs iOS and Android compatible Engineer App can save you masses of time and money.Simply download the App enter a sites unique service PIN code and turn a two-man service job into a one-man service job. Not only will the App countdown the number of tests that need performing successful and failed tests will be reported to your device and you will have the option to add comments or upload photos as required for inclusion in future client reports. No longer will you need to invent a complex verification system to prove that a device has been tested thanks to ENVISION all the data you need will be available 247.In an era when failure to carry out your fire safety responsibilities can leave you open to litigation ENVISION not only makes your job easier it provides indisputable evidence that you are carrying out your mandated duties effectively.Key FeaturesValid for 1 yearPlease note The image is for illustrative purposes only.

GBP 347.76
1

C-Tec ENVS4-1 ENVISION FIRE IOT Software Licence 1-4 Panel Network - 1 YEAR

C-Tec ENVS4-1 ENVISION FIRE IOT Software Licence 1-4 Panel Network - 1 YEAR

C-Tec ENVS4-1 ENVISION FIRE IOT Software Licence 1-4 Panel Network - 1 YEARENVISION software licence for use with ENV-HUB 1-4 panel network.About ENVISION softwareENVISION is a Cloud based remote access service test and data management software package from C-TEC.Add an ENVISION IoT Gateway Hub order code ENV-HUB to your C-TEC CAST protocol fire detection and alarm systems to unlock a host of powerful features that are perfect for installers end users duty holders site managers responsible persons and more.Want to check the status of a CAST system from a remote location Not a problem Wherever you are in the world ENVISION allows you to generate powerful site-specific reports that can be scheduled to arrive on your desktop daily weekly or monthly to help demonstrate due diligence via a verifiable audit trail.Want fires faults tests and other system notifications to be sent in real time to a PC tablet or smart phone Job done Theres even a powerful graphics module that allows you to monitor the progress of a fire as it happens on a user- uploaded site map or building plan.Want evidence that a clients weekly BS 5839-1 user tests are being carried out Its all there at the touch of button.ENVISION really comes into its own if youre an installer or a service and maintenance company. Not only does it allow authorised personnel to interrogate a CAST system prior to visiting site to determine if there are any contaminated devices or other issues ENVISIONs iOS and Android compatible Engineer App can save you masses of time and money.Simply download the App enter a sites unique service PIN code and turn a two-man service job into a one-man service job. Not only will the App countdown the number of tests that need performing successful and failed tests will be reported to your device and you will have the option to add comments or upload photos as required for inclusion in future client reports. No longer will you need to invent a complex verification system to prove that a device has been tested thanks to ENVISION all the data you need will be available 247.In an era when failure to carry out your fire safety responsibilities can leave you open to litigation ENVISION not only makes your job easier it provides indisputable evidence that you are carrying out your mandated duties effectively.Key FeaturesValid for 1 yearPlease note The image is for illustrative purposes only.

GBP 252.00
1