35 results (0,14452 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

C-Tec QT422RX Quantec Mk2 Radio Receiver

C-Tec 24V 5A EN54-4 Switch Mode PSU BF562-5

C-Tec QT602KSSS Quantec Stainless Steel Call Point - Key Reset with Sounder

C-Tec CP414BTV CAST-PRO Smoke Heat Multisensor cw Tone Sounder amp C-3-9.4 White VAD Black Housing

C-Tec CFP708-2 CFP Two Wire 8 Zone AlarmSense Control Panel

C-Tec CFP708-2 CFP Two Wire 8 Zone AlarmSense Control Panel

C-Tec CFP Two Wire 8 Zone AlarmSense Control Panel - CFP708-2C-TECs LPCB certified two-wire CFP AlarmSense fire panel is designed to work with Apollos AlarmSense range of detectors call points sounders and beacons. Most conventional fire systems are designed to work with two pairs of wires per zone one pair for detection devices such as smoke detectors heat detectors and manual call points the other for alarm devices such as bells sounders or strobes. By using different voltage bands for quiescent and alarm states AlarmSense components can be connected to the same pair of supply wires.When powered and controlled by the CFP two-wire fire panel this reliable technology takes all the complexity out of fire alarm system design leading to quicker less expensive and more flexible installation. Indeed research shows an AlarmSense two-wire system can achieve a 20-25 reduction of labour over a standard four wire conventional system. AlarmSense devices are acceptable for BS 5839-1 and BS 5839-6 systems making them particularly useful for fire protection in Houses of Multiple Occupation HMOs.Key FeaturesLPCB certified to EN54 parts 2 and 4Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry to access level 22 4 or 8 AlarmSense zone circuits dependent on model purchasedFour conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSUWide range of engineering functions including zone test coincidence zone delay and non- latching zonesTwo on-board relays Fire and FaultTwo open-collector outputs Remote and ResetClass change and alert inputsInstaller-friendly design accommodates easy first fix and straightforward maintenanceAttractive flush or surface mountable plastic lid and enclosure - no bezel requiredLow quiescent currentMultiple indicatorsEnd of line units included one per zoneAncillary system expansion connections provided for up to eight two-wire repeaters one CFP761 network driver card required per system and optional CFP relay boardsSpace for two x 12V 3.3Ah VRLA batteries

GBP 272.59
1

C-Tec CFP704-2 CFP Two Wire 4 Zone AlarmSense Control Panel

C-Tec CFP704-2 CFP Two Wire 4 Zone AlarmSense Control Panel

C-Tec CFP Two Wire 4 Zone AlarmSense Control Panel - CFP704-2C-TECs LPCB certified two-wire CFP AlarmSense fire panel is designed to work with Apollos AlarmSense range of detectors call points sounders and beacons. Most conventional fire systems are designed to work with two pairs of wires per zone one pair for detection devices such as smoke detectors heat detectors and manual call points the other for alarm devices such as bells sounders or strobes. By using different voltage bands for quiescent and alarm states AlarmSense components can be connected to the same pair of supply wires.When powered and controlled by the CFP two-wire fire panel this reliable technology takes all the complexity out of fire alarm system design leading to quicker less expensive and more flexible installation. Indeed research shows an AlarmSense two-wire system can achieve a 20-25 reduction of labour over a standard four wire conventional system. AlarmSense devices are acceptable for BS 5839-1 and BS 5839-6 systems making them particularly useful for fire protection in Houses of Multiple Occupation HMOs.Key FeaturesLPCB certified to EN54 parts 2 and 4Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry to access level 22 4 or 8 AlarmSense zone circuits dependent on model purchasedFour conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSUWide range of engineering functions including zone test coincidence zone delay and non- latching zonesTwo on-board relays Fire and FaultTwo open-collector outputs Remote and ResetClass change and alert inputsInstaller-friendly design accommodates easy first fix and straightforward maintenanceAttractive flush or surface mountable plastic lid and enclosure - no bezel requiredLow quiescent currentMultiple indicatorsEnd of line units included one per zoneAncillary system expansion connections provided for up to eight two-wire repeaters one CFP761 network driver card required per system and optional CFP relay boardsSpace for two x 12V 3.3Ah VRLA batteries

GBP 226.68
1

C-Tec CFP Two Wire 2 Zone AlarmSense Control Panel - CFP702-2

C-Tec CFP Two Wire 2 Zone AlarmSense Control Panel - CFP702-2

C-Tec CFP Two Wire 2 Zone AlarmSense Control Panel - CFP702-2C-TECs LPCB certified two-wire CFP AlarmSense fire panel is designed to work with Apollos AlarmSense range of detectors call points sounders and beacons. Most conventional fire systems are designed to work with two pairs of wires per zone one pair for detection devices such as smoke detectors heat detectors and manual call points the other for alarm devices such as bells sounders or strobes. By using different voltage bands for quiescent and alarm states AlarmSense components can be connected to the same pair of supply wires.When powered and controlled by the CFP two-wire fire panel this reliable technology takes all the complexity out of fire alarm system design leading to quicker less expensive and more flexible installation. Indeed research shows an AlarmSense two-wire system can achieve a 20-25 reduction of labour over a standard four wire conventional system. AlarmSense devices are acceptable for BS 5839-1 and BS 5839-6 systems making them particularly useful for fire protection in Houses of Multiple Occupation HMOs.Key FeaturesLPCB certified to EN54 parts 2 and 4Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry to access level 22 4 or 8 AlarmSense zone circuits dependent on model purchasedFour conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSUWide range of engineering functions including zone test coincidence zone delay and non- latching zonesTwo on-board relays Fire and FaultTwo open-collector outputs Remote and ResetClass change and alert inputsInstaller-friendly design accommodates easy first fix and straightforward maintenanceAttractive flush or surface mountable plastic lid and enclosure - no bezel requiredLow quiescent currentMultiple indicatorsEnd of line units included one per zoneAncillary system expansion connections provided for up to eight two-wire repeaters one CFP761 network driver card required per system and optional CFP relay boardsSpace for two x 12V 3.3Ah VRLA batteries

GBP 182.66
1

C-Tec CP411VV CAST-PRO CO Fire Smoke Heat Multisensor cw Voice Sounder amp C-3-9.4 White VAD

C-Tec CP411VVR CAST-PRO CO Fire Smoke Heat Multisensor cw Voice Sounder amp O-C-1.9-4 Red VAD

C-Tec CFP708-4 8 Zone Conventional Fire Panel LPCB Approved

C-Tec CFP708-4 8 Zone Conventional Fire Panel LPCB Approved

C-Tec CFP 8 Zone Conventional Fire Panel LPCB Approved - CFP708-4LPCB certified to EN54-24 C-TECs CFP 8 zone conventional fire alarm panel offers an array of user and installer-friendly features at a very competitive price. Supplied in an attractive flush or surface mountable plastic enclosure it includes two detector zones four conventional sounder circuits class change and alert inputs on-board fire and fault relays and combined keypadkey switch entry.A wide range of engineering functions are also provided including selectable zone delays coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided. Optional repeaters relay expansion boards and EN54-13 system compliance devices are also available.Key FeaturesThird-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board LPCB with optional EN54 part 13 compliance from the BSI.Intuitive user-friendly interface with colour-coded buttons and combined keypadkeyswitch entry.Manufactured by C-TEC in the UK.Two detector zone circuits.Four conventional sounder circuitsIntegral 1.5A EN54-4A2 compliant switch mode PSU.Wide range of engineering functions including zone test coincidence zone delay and non-latching zones.Two on-board relays Fire and Fault.Two open-collector outputs Remote and Reset.Class change and alert inputs.Installer-friendly design.Attractive flush or surface mountable plastic lid and enclosure - no bezel required.Low 25mA quiescent current.Multiple indicators.System expansion connections provided for up to eight two-wire repeaters one CFP761 network card required per system optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.Space for two x 12V 3.3Ah VRLA batteries.Fully compatible with C-TECs ActiV range of conventional fire detectors.

GBP 208.82
1

C-Tec QT630 Quantec Dimentia Care Master Controller

C-Tec EP203 3 Zone Automatic Extinguisher Panel LPCB Certified - EP203

C-Tec EP203 3 Zone Automatic Extinguisher Panel LPCB Certified - EP203

C-Tec EP203 3 Zone Automatic Extinguisher Panel LPCB Certified - EP203The EP203 three zone automatic extinguisher panel has been specifically designed for use in areas housing expensive dangerous or irreplaceable items of equipment. Third-party approved by the LPCB to EN 12094-1 the European standard for Fixed Firefighting Systems - Components for Gas Extinguishing Systems and EN54 parts 2 and 4 the panel epitomises quality durability and reliability.Featuring an intuitive 128 x 64 pixel two-colour graphic display that gives clear and concise feedback to the user installer and commissioning engineer the panel also includes six monitored inputs including hold and abort a time stamped log adjustable flood times and volt-free changeover relays for fire local fire 1st stage active 2nd stage active extractor fan and fault.The panel is supplied in an elegantly styled durable enclosure with all of its electronics - apart from its powerful 3A EN54-4 switch mode PSU - mounted on a detachable metal bridge plate for ease of installation. A wide range of ancillaries are also available including remote status units hold-off and abort buttons line terminators and output expansion relay boards.Key FeaturesThird-party LPCB certificated to EN 12094 part 1 and EN54 parts 2 and 4Functions as a standard three zone fire panel with additional circuitry for controlling the release of fire-suppressing gas into protected areasUnique 128 x 64 pixel graphical display facilitates straightforward system programmingAny combination of activated zones can be programmed to automatically start the panels extinguishant release sequenceIncludes a pull-down front-panel manual release button and two keyswitches for accessing the panels functions and toggling between automanual modeThree conventional sounder circuits two x 1st stage one x 2nd stagePowerful 3A EN54-4 compliant switch mode PSULow quiescent current - less than 40mA on mains failWide range of monitored inputs and auxiliary outputs see schematicAbort and hold inputs allow the panels release sequence to be cancelled or suspended at any timeTime-stamped event logRS485 connections for up to eight flush or surface remote status units with their own LCDs manual release and mode automanual switches. Single gang economy status units without an LCD are also available.Extensive range of commissioning and engineering functionsOptional relay expansion boards and single gang abort and hold buttonsIdeal for use in computer rooms telecommunication centres archive storage areas chemical plants generator rooms museums etc..System line terminator included with all panels

GBP 399.43
1

C-Tec Moflash EX Intrinsically Safe Sounder Beacon with Red Lens IS-SB-02-02

C-Tec Moflash EX Intrinsically Safe Sounder Beacon with Amber Lens IS-SB-02-01

C-Tec PDA103C Wall Mounting Counter Hearing Loop Kit 1.2m2

C-Tec PDA103C Wall Mounting Counter Hearing Loop Kit 1.2m2

C-Tec PDA103C Wall Mounting Counter Hearing Loop Kit 1.2m2Hearing loop systems allow hearing impaired people to hear more clearly. Most hearing aids have a T or MT switch which allows them to pick up the electromagnetic field generated by a hearing loop system. The hearing aid converts this signal into a sound suited to its users specific hearing requirements.Any person with a hearing aid positioned within or near the loop can hear the loop signal by switching their hearing aid to the correct position allowing them to participate more effectively in general conversation ordering goods or services listening to public performances etc.The PDA102C is ideal for banks post offices small meetingrooms reception desks ticket booths andany other application requiring restrictedor small area coverage.Key FeaturesIncludes a 3.5mm microphone input foruse with the AMT microphone suppliedand a lineoutreach socket.Adjustable drive control allows theamplifiers output stage to be set-up to suitthe exact characteristics of any room.State-of-the-art audio processor featuresan automatic gain control whichcompensates for poor microphonetechniques and helps suppress loudnoises hisses and clicks.Designed to be free-standing orwall-mounted using the keyholes provided.Technical SpecificationType free-standingwall mountable. Plug top mains lead supplied.Coverage 1.2m2 approx.Mains supply plug top mains lead supplied.Auxiliary inputs 1 x 3.5mm remote mic. Socket 1 x Line Outreach socket.Indicators input level loop current power on.Controls Combined input level loop drive.Product dimension W136 H56 x D178mm amplifier only.Construction finish black metalIP rating IP20Weight 1.25Kg

GBP 189.32
1

C-Tec Moflash EX Intrinsically Safe Sounder Beacon with White Lens IS-SB-02-05

C-Tec Moflash EX Intrinsically Safe Sounder Beacon with White Lens IS-SB-02-05

C-Tec Moflash EX Intrinsically Safe Sounder Beacon with White Lens IS-SB-02-05This LED Beacon has been approved for use in potentially explosive atmospheres for Group I Mining Group II Above Ground applications and incorporates a high Ingress Protected IP66 enclosure.This range is suitable for Fire Security Process Control and general signalling applications. The beacon has a DIP switch that gives the options to change from a 1 Hz 60FPM flash rate to a static constantly on signal.A specially designed time saver base enables quick and easy installation of this unit with no extra cabling to be made to the head of the unit. Connections are made to the base during the initial wiring phase which results in a faster more reliable installation.The beacon head simply twists clicks into the pre-fixed base on commissioning avoiding any additional wiring connections. This unit must be used in conjunction with an approved Zener Barrier or Galvanic Isolator.Key FeaturesApproved by ATEX IECExGroup I MI Ex ia I Ma fGroup II IGD Ex ia IIC T6 Ga Ex ia IIIC T850 C DaZones 0 1 2 20 21 22Conforms to EN 60079-02012 All2013 IEC 60079-02011 EN-60079-112012 IEC 60079-112011Diode Polarised End of line resistor compatibleWhite base version available MOQ applyDustproof WeatherproofPlease note The blue green and white versions are all fitted with clear lenses and it is the internal LEDs which then give the colour when operated.

GBP 222.01
1

C-Tec Moflash EX Intrinsically Safe Sounder Beacon with Green Lens IS-SB-02-04

C-Tec Moflash EX Intrinsically Safe Sounder Beacon with Green Lens IS-SB-02-04

C-Tec Moflash EX Intrinsically Safe Sounder Beacon with Green Lens IS-SB-02-04This LED Beacon has been approved for use in potentially explosive atmospheres for Group I Mining Group II Above Ground applications and incorporates a high Ingress Protected IP66 enclosure.This range is suitable for Fire Security Process Control and general signalling applications. The beacon has a DIP switch that gives the options to change from a 1 Hz 60FPM flash rate to a static constantly on signal.A specially designed time saver base enables quick and easy installation of this unit with no extra cabling to be made to the head of the unit. Connections are made to the base during the initial wiring phase which results in a faster more reliable installation.The beacon head simply twists clicks into the pre-fixed base on commissioning avoiding any additional wiring connections. This unit must be used in conjunction with an approved Zener Barrier or Galvanic Isolator.Key FeaturesApproved by ATEX IECExGroup I MI Ex ia I Ma fGroup II IGD Ex ia IIC T6 Ga Ex ia IIIC T850 C DaZones 0 1 2 20 21 22Conforms to EN 60079-02012 All2013 IEC 60079-02011 EN-60079-112012 IEC 60079-112011Diode Polarised End of line resistor compatibleWhite base version available MOQ applyDustproof WeatherproofPlease note The blue green and white versions are all fitted with clear lenses and it is the internal LEDs which then give the colour when operated.

GBP 222.01
1

C-Tec DL50K Domestic Hearing Loop Amplifier Kit 50m2

C-Tec DL50K Domestic Hearing Loop Amplifier Kit 50m2

C-Tec DL50K Domestic Hearing Loop Amplifier Kit 50m2Hearing loop systems allow hearing impaired people to hear more clearly. Most hearing aids have a T or MT switch which allows them to pick up the electromagnetic field generated by a hearing loop system. The hearing aid converts this signal into a sound suited to its users specific hearing requirements.Any person with a hearing aid positioned within or near the loop can hear the loop signal by switching their hearing aid to the correct position allowing them to participate more effectively in general conversation ordering goods or services listening to public performances etc.Free-standing ideal for bedrooms living rooms TV lounges studies and other domestic applications. Includes a DL50 amplifier plug top power supply loop cable SCART to double phono lead AMT microphone and AFILS fitted sticker.Key FeaturesSimple to adjust and tamper-resistant drive level tone and microphone priority controlsInput peak output current signal present and power on LEDs.Alert tone input for doorbells fire alarms security systems etc.Meets and exceeds the requirements of BS7594 and EN60118-4 when correctly installed.Technical SpecificationType free standing plug top mains lead supplied.Coverage 50m2 approx. To EN60118-4 or 50m2 to BS7594 1993Dimensions W185 x H40 x D85mm amplifier only.Inputs 2 x 3.5mm microphone sockets 1 x dual phono line socket 1 x alert.Indicators Input level loop current meter power on.Controls Input level loop drive tone microphone priority.Kit contents DL50 amplifier plug-top power supply 16m of loop cable SCART-to-double-phono lead AMT microphone AFILS fitted sticker.

GBP 210.59
1

C-Tec PL1K1 Portable Hearing Loop Kit with Storage Shelf 1.2m2

C-Tec PL1K1 Portable Hearing Loop Kit with Storage Shelf 1.2m2

C-Tec PL1K1 Portable Hearing Loop Kit with Storage Shelf 1.2m2Hearing loop systems allow hearing impaired people to hear more clearly. Most hearing aids have a T or MT switch which allows them to pick up the electromagnetic field generated by a hearing loop system. The hearing aid converts this signal into a sound suited to its users specific hearing requirements.Any person with a hearing aid positioned within or near the loop can hear the loop signal by switching their hearing aid to the correct position allowing them to participate more effectively in general conversation ordering goods or services listening to public performances etc.The PL1K1 is ideal for restricted person to person contact in areas such as banks post offices small meeting rooms reception desks open plan offices and ticket booths. The units portable lightweight design means the system can be moved easily from location to location.Key FeaturesSimple one button operation.Integral high-performance microphone.Excellent sound quality.Five years expected battery life under normal operatingcharging conditions.Auto shut-off facility user selectable for 10 30 or 60 minutes helps preserve battery life.Connection of the plug-top charger overrides the timer function to ensure the unit remains operational at all times.Unit can be used as normal whilst charging.Technical SpecificationType - PortableCoverage - 1.2m2 approx.Dimensions - W 271 x H 200 x D 77mm amplifier only 2.82kgInputs 2 x Mic one built-in mic. and one 3.5mm remote mic. socket for AMT or AMD micsIndicators - Power on input level charging required charging in progress audio warning of imminent shutdownControls - Onoff button adjust auto-shut off timer

GBP 202.64
1