11 results (0,14378 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

C-Tec QT631M Quantec Dimentia Care Room Status Controller with Magnetic Reset

C-Tec QT631K Quantec Dimentia Care Room Status Controller with Key Switch Reset

C-Tec NC944 Four Zone Call Controller with Mute Reset Button

C-Tec NC944 Four Zone Call Controller with Mute Reset Button

C-Tec NC944 Four Zone Call Controller with Mute Reset ButtonThe NC944 Four Zone Call Controller is compatible with all 800 Series call points ceiling pulls infrared ceiling receivers monitoring points overdoor lights and remote sounders.Depending on how the Controller is configured and the devices connected to it Standard and Emergency calls can be indicated via its buzzer and zonal LEDs. Two buttons are also provided to allow the user to Reset or Mute standard calls as detailed below.Standard Calls when triggered by a calling device the Controllers internal buzzer sounds continuously and the relevant zone indicators illuminate steady.Pressing the Controllers Reset Button if enabled cancels all standard calls.Pressing the Controllers Mute Button if enabled silences the Controllers internal buzzer. However if a new call standard or emergency is triggered anywhere on the system the buzzer will resound.Emergency Calls when triggered by a calling device the Controllers internal buzzer pulses and the relevant zone indicators flash. This level of call takes priority over standard calls and cannot be muted accepted or reset at the Controller. An emergency call can only be reset at the device from which it was triggered or via a reset point wired on the same zone.Key FeaturesAn attractively-designed four zone call controller cw mute and reset buttonsFully compatible with C-TECs entire range of 800 Series Call System componentsCapable of indicating standard constant tone and emergency intermittent tone callsRequires a separate NC930 12V 250mA PSUIncludes four zonal alarm LEDs RESET and MUTE buttonsTwo open collector outputs Emergency and Aux OutUp to two NC944s can be connected to one NC930 PSU to create a mini-call system of up to 8 zonesMounts on a standard 25mm UK double gang back box

GBP 75.00
1

C-Tec BF365SC Sounder Isolator Controller

C-Tec BF365SC Sounder Isolator Controller

BF365SC Sounder Isolator ControllerBF365SC Conventional Sounder Controller and its associated BF365IM Isolator Modules are designed to interface to a fire alarm panels conventional sounder circuit. The Modules each of which would typically have a conventional sounder connected to it are wired in a loop arrangement beginning and ending at the controller. The Controller transforms the conventional sounder circuits monitoring and triggering voltages into its own unique control voltages which it uses to trigger the Isolator Modules and monitor the sounder loop wiring.Each Module has smart sensing which means if a wiring fault should occur the Modules nearest to the faulty section of cabling will if needed isolate this section. As the Modules are driven from each direction any loss of cable integrity will have no effect on the functionality of the actual sounders. Having a fault tolerant arrangement such as this means that low cost cabling can be used for the sounder circuit subject to the fire officers approval leading to significant savings in installation.Key FeaturesDesigned to meet requirement 17.9.2c of Dutch standard NEN2575BSI certified to EN54 parts 17 18Easily interfaced to a conventional fire alarm sounder circuitAllows low-cost non-fire resistant sounder circuit cabling to be used when used in conjunction with our BF365IM Isolator Modules subject to fire officer approval.Wiring must be made in a loop arrangement beginning and ending at the controllerIf a wiring fault should occur the Modules nearest to the faulty section of cabling will if needed isolate this section. As the Modules are driven from each direction any loss of cable integrity will have no effect on the functionality of the actual soundersFits on standard UK 25mm flush or surface mount back boxesNot suitable for use in the UK

GBP 77.21
1

C-Tec CA738 CAST 1 Way Sounder Controller

C-Tec NC887D Conventional Switchable Sounder

C-Tec XFP508H Hush Button Hochiki ESP Protocol

C-Tec XFP508H Hush Button Hochiki ESP Protocol

C-Tec XFP508H Hush Button Hochiki ESP ProtocolThe XFP508H Hush Button has been specifically designed to reduce the incidence of false alarms in houses of multiple occupation by providing reliable fully monitored fire detection alarm and silencing facilities inside each individual flat or apartment.It can be looked upon as a miniature loop-powered single zone fire alarm controller that sits and is addressed on an Hochiki ESP analogue loop with the ability to communicate its status back to the host panel. On a typical system one Hush Button is fitted in each dwelling complete with conventional detectors and conventional sounders to provide occupants with a simple means of invoking two types of hushed period.By providing occupants with this level of control over their fire alarm systems it helps reduce false alarms and prevent unnecessary building evacuations system vandalism and the likelihood of a true alarm signal being ignored.Key FeaturesUpgrades the level of protection offered in a flat or apartment from the Grade D minimum mainsbattery smoke alarms to Grade A or BProvides each individual dwelling with a 2 minute silence facility and 15 minute isolate facility to BS 5839 pt 6 clause 12.2Can be operated by building occupants whilst standing at floor levelIncludes a built-in loop isolator conventional sounder circuit conventional detector circuit and three status LEDsFully monitored for open and short circuit faults logging facilities at the host panel give full traceability of any problemsFailsafe operation - a general fire condition at the host panel will override any silencedisolated state at the hush button and immediately turn on its local soundersOperation of a manual call point fitted with a resistor of less than 400 ohm will immediately trigger the host panel a 330 Ohm resistor is suppliedCommon OV line allows sounders and detectors to be wired in three core cable

GBP 74.52
1

C-Tec XFP508X Hush Button Apollo XP95 Discovery Protocol

C-Tec XFP508X Hush Button Apollo XP95 Discovery Protocol

C-Tec XFP508X Hush Button Apollo XP95 Discovery ProtocolThe XFP508X Hush Button has been specifically designed to reduce the incidence of false alarms in houses of multiple occupation by providing reliable fully monitored fire detection alarm and silencing facilities inside each individual flat or apartment.It can be looked upon as a miniature loop-powered single zone fire alarm controller that sits and is addressed on an XP95 Discovery or Xplorer analogue loop with the ability to communicate its status back to the host panel. Typically one Hush Button is fitted in each dwelling complete with conventional detectors and conventional sounders to provide occupants with a simple means of invoking two types of hushed period.By providing occupants with this level of control over their fire alarm systems it helps reduce false alarms and prevent unnecessary building evacuations system vandalism and the likelihood of a true alarm signal being ignored.Key FeaturesUpgrades the level of protection offered in a flat or apartment from the Grade D minimum mainsbattery smoke alarms to Grade A or BProvides each individual dwelling with a 2-minute silence facility and 15 minute isolate facility to BS 5839 pt 6 clause 12.2Can be operated by building occupants whilst standing at floor levelIncludes a built-in loop isolator conventional sounder circuit conventional detector circuit and three status LEDsFully monitored for open and short circuit faults logging facilities at the host panel give full traceability of any problemsFailsafe operation - a general fire condition at the host panel will override any silencedisolated state at the hush button and immediately turn on its local soundersOperation of a manual call point fitted with a resistor of less than 400 ohm will immediately trigger the host panel a 330 Ohm resistor is suppliedCommon OV line allows sounders and detectors to be wired in three core cable

GBP 74.52
1