18 results (0,13593 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

C-Tec CFP760 8 Zone Repeater Panel

C-Tec FF396-2 FP10 10Z Fire Repeater Panel

C-Tec FF596 MFP 8 Zone Repeater Panel

C-Tec ZREP1SCA ZFP Multipath Repeater S CAST

C-Tec XFP510-32 XFP Repeater Panel 32 Zone

C-Tec XFP510-32 XFP Repeater Panel 32 Zone

C-Tec XFP510-32 XFP Repeater Panel 32 ZoneCan be used to repeat the functions of an XFP Main panel at remote parts of a site e.g. all potential fire service entrances. Offers all of the functions and controls of an XFP Main panel access levels 1 2 and 3. Includes an on-board fault relay. Requires its own dedicated Mains power and battery back-up supply.A maximum of eight XFP Repeaters can be connected to one non-networked XFP Main panel. Communication between the XFP Main panel and Repeater requires an AFP711 network driver card fitted as standard in all XFP510-32s available as an optional extra on Main XFP 32 Zone panels. Repeater network wired in 1.5 mm2 two-core screened fire resistant cable. Network length must not exceed 500 metres.Key FeaturesCan be used to repeat the functions of an XFP Main panel at remote parts of a site e.g. all potential fire service entrances.Offers all of the functions and controls of an XFP Main panel access levels 1 2 and 3.Includes an on-board fault relay.Requires its own dedicated Mains power and battery back-up supply.A maximum of eight XFP Repeaters can be connected to one non-networked XFP Main panel.Communication between the XFP Main panel and Repeater requires an AFP711 network driver card fitted as standard in all XFP510-32s available as an optional extra on Main XFP 32 Zone panels.Repeater network is non-redundant and wired in 1.5 mm2 two-core screened fire resistant cable. Network length must not exceed 500 metres.

GBP 433.36
1

C-Tec XFP510-16 XFP Repeater Panel 16 Zone

C-Tec XFP510-16 XFP Repeater Panel 16 Zone

C-Tec XFP510-16 XFP Repeater Panel 16 ZoneCan be used to repeat the functions of an XFP Main panel at remote parts of a site e.g. all potential fire service entrances. Offers all of the functions and controls of an XFP Main panel access levels 1 2 and 3. Includes an on-board fault relay. Requires its own dedicated Mains power and battery back-up supply.A maximum of eight XFP Repeaters can be connected to one non-networked XFP Main panel. Communication between the XFP Main panel and Repeater requires a CFP761 network driver card fitted as standard in all XFP510-16s available as an optional extra on Main XFP 16 Zone panels. Repeater network wired in 1.5 mm2 two-core screened fire resistant cable. Network length must not exceed 500 metres.Key FeaturesCan be used to repeat the functions of an XFP Main panel at remote parts of a site e.g. all potential fire service entrances.Offers all of the functions and controls of an XFP Main panel access levels 1 2 and 3.Includes an on-board fault relay.Requires its own dedicated Mains power and battery back-up supply.A maximum of eight XFP Repeaters can be connected to one non-networked XFP Main panel.Communication between the XFP Main panel and Repeater requires a CFP761 network driver card fitted as standard in all XFP510-16s available as an optional extra on Main XFP 16 Zone panels.Repeater network wired in 1.5 mm2 two-core screened fire resistant cable. Network length must not exceed 500 metres.

GBP 315.26
1

C-Tec ZREP1FCA ZFP Multipath Repeater F CAST

C-Tec CFP Network Driver Card CFP761

C-Tec ZREP1F ZFP Compact Controller Flush Mounted

C-Tec ZREP1S ZFP Compact Controller Surface Mounted ZREP1S

C-Tec AFP711 XFP Network Communications Card

C-Tec AFP711 XFP Network Communications Card

C-Tec AFP711 XFP Network Communications CardAn optional system expansion device for use with XFP 12 Loop 32 Zone fire panels. Allowsthe connection of up to eight XFP Repeaters or eight XFP Main panels any mix on an RS485 network. One AFP711 card required per networked Main XFP 12 Loop 32 Zone panel note that XFP510-16 and XFP510-32 repeaters include a network driver card as standard.The AFP711 is NOT compatible with XFP Single Loop 16 Zone panels which require a CFP761 card for networking.Key network protocol features when used for interconnecting XFP main panelsCan be used to connect up to 8 XFP main panels any mix over a two-wire RS485 network of up to 1KM in length.Each networked XFP can be programmed to accept Fires Faults and Control actions such as Silence Alarm Sounders and Control Panel Resets from other panels.Each XFP will accept Disablement commands for zones sounders and output sets from other panels.All panels monitored for network wiring faults.Fires and faults on remote panels are displayed on local panels including the point description.CEs can be programmed into local panels dependent on which remote panel is in alarm.The network supports the programming of site data into remote panels from a PC at a local panel.Time and date is common to all panels.All networked main panels require a network communication card.It is not possible to mix XFP main panels and XFP repeaters on the same network.Key network protocol features when used for connecting XFP repeatersCan be used to connect up to 8 XFP repeaters any mix to one XFP main panel.Up to 500m of cable may be fitted to an XFP two-wire repeater network.Each XFP repeater offers all the functions and controls of an XFP main panel.The XFP main panel must have a network communication card fitted.It is not possible to mix XFP main panels and XFP repeaters on the same network.

GBP 114.65
1

C-Tec XFP761 XFP Network Card For 16 Zone Panels

C-Tec NC832KE Conventional 30 Zone Surface Emergency Master Panel

C-Tec NC832KE Conventional 30 Zone Surface Emergency Master Panel

C-Tec NC832KE Conventional 30 Zone Surface Emergency Master PanelNC812KE NC822KE and NC832KE indicator panels are fully compatible with all 800 Series call points ceiling pulls infrared ceiling receivers monitoring points overdoor lights and remote sounders.Depending on the devices wired to it Standard and Emergency calls can be indicated via its buzzer and zonal LEDs. An optional Mute button is also provided to allow the user to silence standard calls.Standard Calls when triggered by a calling device the indicator panels internal buzzer sounds continuously and the relevant zone indicators illuminate steady.Pressing the Indicator Panels Mute Button if fitted silences the Panels internal buzzer. However if a new call standard or emergency is triggered anywhere on the system the buzzer will resound.Emergency Calls when triggered by a calling device theIndicator Panels internal buzzer pulses and the relevant zone indicators flash. This level of call takes priority over standard calls and cannot be muted at the Panel. An emergency call can only be reset at the device from which it was triggered or via a reset point wired on the same zone.Key FeaturesFully compatible with C-TECs entire range of 800 Series Call System componentsCapable of indicating standard constant tone and emergency intermittent tone calls10 20 or 30 zonal alarm LEDs dependent on model purchased see below for parts listingOptional mute button2 volt-free relay contactsSurface mountingConnections for optional Repeater panels and sounders to increase call indication levels

GBP 466.69
1