280 results (0,13718 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

FireClass FC410MIM Addressable Mini Input Module

Fireclass 516.800.933FC Address Flag Labels Loop C Purple

Fireclass 516.016.237FC ProReact 170 Degree C Indoor Tie Wrap - Pack of 100

Fireclass 516.016.238FC ProReact 170 Degree C IndoorOutdoor Tie Wrap - Stainless Steel - Pack of 100

Fireclass 516.016.236FC ProReact 110 Degree C IndoorOutdoor Cable Tie UV amp Heat Stabilised - Pack of 100

Fireclass DPK6 Duct Probe with 4B-C 4quot Continuity Base

Fireclass DPK6 Duct Probe with 4B-C 4quot Continuity Base

Fireclass DPK6 Duct Probe with 4B-C 4 Continuity BaseThe DPK6 duct probe units have been developed to detect smoke in ventilation ducts and offer significant benefits in terms of performance and installation. For most applications smoke or combustion products are likely to have travelled some distance ageing the smoke prior to reaching the probe unit. It is therefore normally recommended that an optical smoke detector be fitted and this is often a requirement of building regulations. The DPK6 duct probe units use FC460PH Multi Sensor Smoke Detectors.The DPK6 Duct Probe units are not normally mounted directly inside ducts because the airflow only allows the detector to sample air from a small section of the duct and such detectors would rapidly become dirty. Instead ducting is protected by the use of probe units which gather air from a cross section of the duct and pass it through a smoke detector head.The system comprises only one single duct probe tube which improves efficiency and reduces installation time. The DPK6 duct smoke detector housing is designed to comply with the stringent demands of new European standard EN 54-27. The system fulfils all the requirements for safe fire detection with airflow speeds from 15 ms to 20 ms. For the airflow through the adaptor to be representative of the airflow in the ventilation duct the detector should be installed at a place where normally flow meters etc. are sited.Key FeaturesDPK6 for use with FC460PH with built-in 4B-C 4 continuity base.Designed to comply with EN 54-27.One-pipe air sampling system.Patented Cap-up Venturi pipe and duct housing.Test hole on cover.Simple installation.Sensitive flow indicator.Simple service and maintenance.Range of aluminium probe tubes are available for ducts up to 2700 mm.

GBP 134.30
1

Fireclass 557.202.708FC FC410MIM Fixing Kit for FireClass 1.9A7Ah PSUs

Fireclass 590.000.002FC NEO4250E Extension Controller amp 4 Channels Up To 1000W

Fireclass 590.000.004FC NEO8250E Extension Controller amp 8 Channels Up To 8000W

Fireclass 590.000.004FC NEO8250E Extension Controller amp 8 Channels Up To 8000W

Fireclass 590.000.004FC NEO8250E Extension Controller 8 Channels Up To 8000WLDA NEO Extension 8250 is an extension unit for the EN 54-16PAVA system NEO. This extension unit scales the NEO system with 8 more zonesas it includes 8 class D power amplifier channels of 250W at 100V or 70V.Audio is transmitted from the main unit to this extensionunit via a daisy-chain connection by Flexnet and using audio over Ethernet.Therefore it guarantees maximum audio quality and integrity in the signal.The NEO Extension is fully configurable with theNEO-Configurator software included with NEO. It is possible to configureremotely the unit as part of the whole NEO system and create events to performactions in the system triggered by conditions of input level datetimeUDP command a GPIO or button from MPS microphone.Key Features8 class D amplifiers of 250W for 70 or 100V lines8 pre-amp outputs for external PA amplifiers connection.DSP 7-band inputoutput Parametric Equalizer loudness LDAsound enhancer independent volume control per each output channel and audiofilters.Triple Ethernet port for Digital Audio Cobranet remotecontrol and supervision and for escalating the system with NEO-Extensions inredundant daisy-chain mode with Flexnet technology up to 1024 zones.Control for up to 32 attenuators LDA AT6.Integrated frontal loudspeaker for monitoring.12 supervised contact relays for integrationwith Fire Alarm Control Panel.

GBP 4495.06
1

Fireclass 590.000.003FC NEO4500E Extension Controller amp 4 Channels Up To 2000W

Fireclass 557.202.082FC BACnet UC-8112-ME-T-LX Interface with CBL-F9DPF1x4-BK-100

Fireclass FC506 6 Loop Panel 500 Points

Fireclass FC506 6 Loop Panel 500 Points

Fireclass FC506 6 Loop Panel 500 PointsThe FC506is the newest FireClass addressable solution for a wide range of applications and requirements. Conceived to be extremely easy to install and use the FC506is an out of the box panel which offers thesimplicity of a conventional system and the benefits of the FireClass addressable digital technology. Auto Addressing Intelli-Zone Online Help function USB interface to upload the configuration and the easiness to configure the panel via integrated keypad are only some of the features that allow the installation and configuration of the panels in just a few simple steps.The FC506 auto-addressing panel has 6 in 2 loops that can support up to 500 addressable devices and 32 zones. The split loop technology enables 3 circuits of devices to be connected to one single loop providing greater flexibility andsimplifying the wiring process. Once the loop devices are wired the system can be auto addressed by a single click. The devices are automatically assigned to 32 zones according to the physical loop they are connected to the system is ready to protect the site. If the system configuration needs to be modified and the devices re-addressed or the zones re-programmed the powerful Intelli-Zone feature significantly reduces the configuration time allowing the installer to perform test and programming at once. The configuration software is extremely user friendly and provides a very nice graphic interface that displays all devices connected to the different zones.A battery and wire calculation tool is included in the software to help the installer in sizing up the system. A free graphic maps software based on a multilevel maps tree structure allows a remote real time visualization of any loop zone and point statusand the simple remote user interface with control buttons reset silence evacuate allow users to manage the system from any location in the world. This new FireClass FC506control panel supports up to 500 devices including the double and triple technology detectors and a plenty of modules and sounders benefiting of one of the widest ranges available in the market.Key Features 6 in 2 loopsUp to 800mA current dynamically shared across 3 loop circuitsAuto mapping with Intelli-Zone featureOnline Help functionUSB interface dual role HostDeviceMulti users and multi installers Up to 2 installers 8 usersWalk test function4000 Event LogLoop break locationOn board PSTN communicatorGSMGPRS as external moduleUp to 8 repeaters and up to 7 FC500 Series panel clientsEvent transmission through PSTN and IPAutomatic drift compensationFast and simple system configuration also offlineTransferable user databaseDevice graphic displayedBattery and wiring calculationCustomizable cables databaseVisualization of all the devices assigned to a single zoneRemote real time visualization of control panel loop and zone status and so on.Easy remote user interface with control buttons reset silence evacuateMultilevel map based on a tree structureAccess device data from any pages of the mapConfiguration downloadable to USB memory stickCapability to print zone label sheet for front panel customization

GBP 1073.92
1

Fireclass FC503 3 Loop Panel 250 Points

Fireclass FC503 3 Loop Panel 250 Points

Fireclass FC503 3 Loop Panel 250 PointsThe FC503 is the newest FireClass addressable solution for a wide range of applications and requirements. Conceived to be extremely easy to install and use the FC503 is an out of the box panel which offers the simplicity of a conventional system and the benefits of the FireClass addressable digital technology. Auto Addressing Intelli-Zone Online Help function USB interface to upload the configuration and the easiness to configure the panel via integrated keypad are only some of the features that allow the installation and configuration of the panels in just a few simple steps.The FC503 panel has 3 in 1 loops that can support up to 250 addressable devices and 32 zones. The split loop technology enables 3 circuits of devices to be connected to one single loop providing greater flexibility andsimplifying the wiring process. Once the loop devices are wired the system can be auto addressed by a single click. The devices are automatically assigned to 32 zones according to the physical loop they are connected to the system is ready to protect the site. If the system configuration needs to be modified and the devices re-addressed or the zones re-programmed the powerful Intelli-Zone feature significantly reduces the configuration time allowing the installer to perform test and programming at once. The configuration software is extremely user friendly and provides a very nice graphic interface that displays all devices connected to the different zones.A battery and wire calculation tool is included in the software to help the installer in sizing up the system. A free graphic maps software based on a multilevel maps tree structure allows a remote real time visualization of any loop zone and point statusand the simple remote user interface with control buttons reset silence evacuate allow users to manage the system from any location in the world. This new FireClass FC503 control panel supports up to 250 devices including the double and triple technology detectors and a plenty of modules and sounders benefiting of one of the widest ranges available in the market.Key Features3 in 1 loopsUp to 800mA current dynamically shared across 3 loop circuitsAuto mapping with Intelli-Zone featureOnline Help functionUSB interface dual role HostDeviceMulti users and multi installers Up to 2 installers 8 usersWalk test function4000 Event LogLoop break locationOn board PSTN communicatorGSMGPRS as external moduleUp to 8 repeaters and up to 7 FC500 Series panel clientsEvent transmission through PSTN and IPAutomatic drift compensationFast and simple system configuration also offlineTransferable user databaseDevice graphic displayedBattery and wiring calculationCustomizable cables databaseVisualization of all the devices assigned to a single zoneRemote real time visualization of control panel loop and zone status and so on.Easy remote user interface with control buttons reset silence evacuateMultilevel map based on a tree structureAccess device data from any pages of the mapConfiguration downloadable to USB memory stickCapability to print zone label sheet for front panel customization

GBP 722.82
1

Fireclass 557.202.811FC CPU801 Spare CPU

Fireclass 576.440.016FC FC440CAVB Addressable Base Sounder VAD BC

Fireclass 576.440.016FC FC440CAVB Addressable Base Sounder VAD BC

Fireclass 576.440.016FC FC440CAVB Addressable Base Sounder VAD BCThe Visual Alarm Device VAD Sounder Beacons are loop powered units that are driven from an addressable controller panel. They are available in ceiling and outdoor wall mounted variants.The ceiling mounted variants provide a base for fitting a fire detector. Alternatively a blanking cap is fitted.All VAD Sounder Beacons have a built-in two port loop short circuit isolator. Settings for tones volume beacon flash and status monitoring are configurable using the control panel.Selectable flash rates are1Hz one flash every second0.5Hz one flash every two secondsKey FeaturesA compact and unobtrusive sounder solutionShorter Light Pulse for faster responseFC445CAV has an outdoor version with a deep surface back box for use with suitable IP-rated glands and cablingPower and data from the loop. No additional wiring or power supplies requiredBuilt-in line isolator15 selectable tones for FC440CAVBRealistic Conventional Bell Tone4 selectable volumes for FC440CAVB2 selectable flash ratesSelect the tone volume and flash rate using panel configuration softwareMounting orientation CeilingIndoor type AOutdoor type B IndoorWeight g 178Housing colour ClearOperating temperature C -25 to 70Storage temperature C -25 to 70Humidity Up to 95 non-condensingEN54-17 isolator YesEN54-3 sounder YesEN54-23 visual alarm YesVibration shock corrosion EMC Complies with EN54 series requirementsIngress protection rating IP21CFlash colour White

GBP 202.74
1

Fireclass FC501-H Triple Circuit Single Loop Panel with 2.5A PSU

Fireclass FC501-H Triple Circuit Single Loop Panel with 2.5A PSU

Fireclass FC501-H Triple Circuit Single Loop Panel with 2.5A PSUFC501 is the newest FireClass addressable solution for small systems brought to you by Tyco Fire Protection Products. Conceived to be extremely easy to install and use the FC501 is an out of the box panel which offers the simplicity of a conventional system and the benefits of the FireClass addressable digital technology.Auto Addressing Intelli-Zone On line Help function USB interface to upload the configuration and the easiness to configure the panel via integrated keypad are only some of the features that allow the installation and configuration of the FC501 in just a few simple steps.This 3 in 1 loop panel enables 3 circuits of devices to be connected to this single loop panel providing greater flexibility and simplifying the wiring process. Once the loop devices are wired the system can be auto addressed by a single click. The devices are automatically assigned to 3 zones according to the physical loop they are connected to the system is ready to protect the site. If the system configuration needs to be modified and the devices re-addressed or the zonesre-programmed the powerful Intelli-Zone feature significantly reduces the configuration time allowing the installer to perform test and programming at once. The configuration software is extraordinarily user friendly and provides a very nice graphic interface that displays all devices connected to the different zones. A battery and wire calculation tool is included in the software to help the installer in sizing up the system.A free graphic maps software based on a multilevel maps tree structure allows a remote real time visualization of any loop zone and point status and the simple remote user interface with control buttons reset silence evacuate allow users to manage the system from any location in the world. The FireClass FC501 control panel supports a total of 128 devices including the double and triple technology detectors and a plenty of modules and sounders benefiting of one of the widest ranges available in the market.Key Features3 in 1 LoopsUp to 400mA current dynamically shared across 3 loop circuitsTwo versions available 1.5 A or 2.5 A power supplyUp to 128 Addresses 32 ZonesEasy to programmeAuto AddressingAuto mapping with Intelli-Zone featureOut of the BoxOn Line Help functionUSB interface dual role HostDeviceMulti UsersMulti Installers Up to 2 Installers 8 UsersWalk test function4000 Event LogLoop break locationOn board PSTN communicatorOptional IP boardGSMGPRS as external moduleLCD display 160 CharactersUp to 4 repeatersUp to 4 Multifunction interfaces for printer simplified fire brigade panelsEvent transmission via PSTN and IPFront panel controls enabling text and configuration changesDisplays temperature CO level and smoke level at any pointAutomatic drift compensation

GBP 501.42
1

Fireclass FC501-L Triple Circuit Single Loop Panel with 1.5A PSU

Fireclass FC501-L Triple Circuit Single Loop Panel with 1.5A PSU

Fireclass FC501-L Triple Circuit Single Loop Panel with 1.5A PSUFC501 is the newest FireClass addressable solution for small systems brought to you by Tyco Fire Protection Products. Conceived to be extremely easy to install and use the FC501 is an out of the box panel which offers the simplicity of a conventional system and the benefits of the FireClass addressable digital technology.Auto Addressing Intelli-Zone On line Help function USB interface to upload the configuration and the easiness to configure the panel via integrated keypad are only some of the features that allow the installation and configuration of the FC501 in just a few simple steps.This 3 in 1 loop panel enables 3 circuits of devices to be connected to this single loop panel providing greater flexibility and simplifying the wiring process. Once the loop devices are wired the system can be auto addressed by a single click. The devices are automatically assigned to 3 zones according to the physical loop they are connected to the system is ready to protect the site. If the system configuration needs to be modified and the devices re-addressed or the zonesre-programmed the powerful Intelli-Zone feature significantly reduces the configuration time allowing the installer to perform test and programming at once. The configuration software is extraordinarily user friendly and provides a very nice graphic interface that displays all devices connected to the different zones. A battery and wire calculation tool is included in the software to help the installer in sizing up the system.A free graphic maps software based on a multilevel maps tree structure allows a remote real time visualization of any loop zone and point status and the simple remote user interface with control buttons reset silence evacuate allow users to manage the system from any location in the world. The FireClass FC501 control panel supports a total of 128 devices including the double and triple technology detectors and a plenty of modules and sounders benefiting of one of the widest ranges available in the market.Key Features3 in 1 LoopsUp to 400mA current dynamically shared across 3 loop circuitsTwo versions available 1.5 A or 2.5 A power supplyUp to 128 Addresses 32 ZonesEasy to programmeAuto AddressingAuto mapping with Intelli-Zone featureOut of the BoxOn Line Help functionUSB interface dual role HostDeviceMulti UsersMulti Installers Up to 2 Installers 8 UsersWalk test function4000 Event LogLoop break locationOn board PSTN communicatorOptional IP boardGSMGPRS as external moduleLCD display 160 CharactersUp to 4 repeatersUp to 4 Multifunction interfaces for printer simplified fire brigade panelsEvent transmission via PSTN and IPFront panel controls enabling text and configuration changesDisplays temperature CO level and smoke level at any pointAutomatic drift compensation

GBP 479.87
1

Fireclass FC501-HK Triple Circuit Single Loop Panel with Icons and 2.5A PSU

Fireclass FC501-HK Triple Circuit Single Loop Panel with Icons and 2.5A PSU

Fireclass FC501-HK Triple Circuit Single Loop Panel with Icons and 2.5A PSUFC501 is the newest FireClass addressable solution for small systems brought to you by Tyco Fire Protection Products. Conceived to be extremely easy to install and use the FC501 is an out of the box panel which offers the simplicity of a conventional system and the benefits of the FireClass addressable digital technology.Auto Addressing Intelli-Zone On line Help function USB interface to upload the configuration and the easiness to configure the panel via integrated keypad are only some of the features that allow the installation and configuration of the FC501 in just a few simple steps.This 3 in 1 loop panel enables 3 circuits of devices to be connected to this single loop panel providing greater flexibility and simplifying the wiring process. Once the loop devices are wired the system can be auto addressed by a single click. The devices are automatically assigned to 3 zones according to the physical loop they are connected to the system is ready to protect the site. If the system configuration needs to be modified and the devices re-addressed or the zonesre-programmed the powerful Intelli-Zone feature significantly reduces the configuration time allowing the installer to perform test and programming at once. The configuration software is extraordinarily user friendly and provides a very nice graphic interface that displays all devices connected to the different zones. A battery and wire calculation tool is included in the software to help the installer in sizing up the system.A free graphic maps software based on a multilevel maps tree structure allows a remote real time visualization of any loop zone and point status and the simple remote user interface with control buttons reset silence evacuate allow users to manage the system from any location in the world. The FireClass FC501 control panel supports a total of 128 devices including the double and triple technology detectors and a plenty of modules and sounders benefiting of one of the widest ranges available in the market.Key Features3 in 1 LoopsUp to 400mA current dynamically shared across 3 loop circuitsTwo versions available 1.5 A or 2.5 A power supplyUp to 128 Addresses 32 ZonesEasy to programmeAuto AddressingAuto mapping with Intelli-Zone featureOut of the BoxOn Line Help functionUSB interface dual role HostDeviceMulti UsersMulti Installers Up to 2 Installers 8 UsersWalk test function4000 Event LogLoop break locationOn board PSTN communicatorOptional IP boardGSMGPRS as external moduleLCD display 160 CharactersUp to 4 repeatersUp to 4 Multifunction interfaces for printer simplified fire brigade panelsEvent transmission via PSTN and IPFront panel controls enabling text and configuration changesDisplays temperature CO level and smoke level at any pointAutomatic drift compensation

GBP 531.17
1

Fireclass 576.440.017FC FC445CAV Addressable Wall Sounder VAD BC

Fireclass 576.440.017FC FC445CAV Addressable Wall Sounder VAD BC

Fireclass 576.440.017FC FC445CAV Addressable Wall Sounder VAD BCThe 576.440.017FC is a FC445CAV Addressable Wall Sounder VAD BC.This model is compatible with FC510 and FC520 panels and should be used only with those panels. The panel display will show device type of the previous FC410LPBS and FC430LPBSB.The Visual Alarm Device VAD Sounder Beacons are loop powered units that are driven from an addressable controller panel. They are available in ceiling and outdoor wall mounted variants.The ceiling mounted variants provide a base for fitting a fire detector. Alternatively a blanking cap is fitted.All VAD Sounder Beacons have a built-in two port loop short circuit isolator. Settings for tones volume beacon flash and status monitoring are configurable using the control panel.Selectable flash rates are1Hz one flash every second0.5Hz one flash every two secondsKey FeaturesA compact and unobtrusive sounder solutionShorter Light Pulse for faster responseFC445CAV is outdoor versions with a deep surface back box for use with suitable IP-rated glands and cablingPower and data from the loop. No additional wiring or power supplies requiredBuilt-in line isolator16 selectable tones for FC445CAVRealistic Conventional Bell Tone2 selectable volumes for FC445CAV2 selectable flash ratesSelect the tone volume and flash rate using panel configuration softwareCoverage volume code Open ClassDevices per loop Up to 44Flash rate 0.5 1 HzDimensions WxHxD mm 105x153x 97 with I.P. BackBoxSound output 1m Up to 100dBABody colour RedFlash colour WhiteIP code IP55Approvals EN54-3 23 17Housing material PC-ABSOperating temperature C -25 to 70Storage temperature C -25 to 70Humidity Up to 95 non-condensingPressure Sounder SPL output quoted for 1000 mBarEN54-17 isolator YesEN54-3 sounder YesEN54-23 visual alarm YesBeacon intensity settings 1Vibration shock corrosion EMC Complies with EN54 series requirementsBeacon flash rates 0.5 and 1 Hz

GBP 251.53
1