233 results (0,17031 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Gent VIG-MIM-A3 A3 Zonal and Graphic Mimic

Gent VIG-MIM-A3 A3 Zonal and Graphic Mimic

Gent VIG-MIM-A3 A3 Zonal and Graphic MimicA Vigilon A3 Mimic panel VIG-MIM-A3 must be connected to a loop circuit of a Vigilon fire detection and alarm system. It is used to provide indication of fire events in the system. However it can also be used to provide indication of fault and supervisory events in the system. The panel can be mounted in landscape or portrait orientation. A Customised Mimic holds a pictorial overlay that represents the protected building or an area within.A fire event is indicated by the illumination of appropriate red LEDs behind the overlay to show the location of the fire. A Zonal Mimic provides a traditional zone by zone indication of a fire. Each zone is given a location label to identify the area within a building. The panel illumination defaults to a Zonal Mimic but can be reprogrammed during commissioning to be a Customised Mimic.An array of red lights illuminates individually or in groups. Illuminations may be applied to include custom shapes text and digital clock in small or large size. A site specific welcome message may be configured for display during quiescent conditions that can scroll if it is too long to fit the display area. First or last fire flashing option with in phase or anti phase flash. The panel has its own mains derived power supply with battery for standby power in the event of mains supply failure.Key FeaturesThe panel illumination defaults to a Zonal Mimic but can be programmed during commissioning to be a Customised MimicThe panel has its own mains derived power supply with battery Repeat Panels and Mimics require external power supplyThe panel is supplied with pre-printed and blank high quality UV protected A3 sheets

GBP 2007.71
1

Gent ALD-302 Anti Ligature Base for the S-Quad Sensor Requires S4-700 Base

Gent 19104-52 Din Rail Mounting Polarised Relay for Mounting Inside the Interface

Gent S4T-780-S S4 SELF TEST Heat Sensor and Sounder

Gent S4T-780-S S4 SELF TEST Heat Sensor and Sounder

Gent S4T-780-S S4 SELF TEST Heat Sensor and SounderThe GENT S4T-780-S Self-Test Heat Sensor with Integrated Sounder has a new IP21 external moulding new detector chamber design and a dual microprocessor PCB. This design delivers even better smoke detection and voice storage capacity. In addition the award-winning Self-Test feature allows both the heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Enables discrete functional testing and visual inspection of the fire alarm system by reducing the engineer toolset to just a mobile device phone or tablet. No more impact on building occupiers Tests both the heat and smoke sensors by heating the thermistor and introducing small amounts of smoke into the detection chamber Gently blows the smoke out of the detection chamber and smoke entry points to ensure they are not blocked Flexible testing options allow the engineer to test in different ways single device detection zone loops panels Allows up to 6 devices to be tested at once per loop and any number of loops can be tested simultaneously making the functional testing incredibly fast Device testing is fast enough to allow up to 4 functional tests to be performed per year for the lifespan of the device Eliminates all access issues when detector testing ensuring 100 functional testing is achieved Allows the system to remain active whilst testing as each detector is only offline for 60 seconds and outputs are not generated Any fires detected outside of the devices performing Self-Test will stop the Self-Test process and operate the fire systems Cause Effect Allows the engineer to easily locate the detector using the App and BLE to check the device number label zone description and detector type Allows simple device updates to be performed through the App including the correction of inaccurate device labels and loop mapping The app and BLE handshake verifies that the engineer has been within visual inspection range Optional Inspection prompt LEDs on the device let the engineer know what Self-Test devices need to be visually inspected and will automatically turn off when the visual inspection is complete Engineers can spend more time digitally capturing non-compliance issues and advising how to resolve them. This includes any issues causing false alarms Test Fire LED option in the App allows the fire LED to be tested a pending BS5839-1 testing requirement. This feature can additionally confirm that they are inspecting the correct device The CLSS App allows the engineer to simulate a fire and test the Cause Effect logic The CLSS App also allows the Cause Effect to be triggered through a successful Self-Test operation allowing a witness test to be performed using real smoke

GBP 141.83
1

Gent S4T-770-S S4 SELF TEST Optical Heat Sensor amp Sounder

Gent S4T-770-S S4 SELF TEST Optical Heat Sensor amp Sounder

Gent S4T-770-S S4 SELF TEST Optical Heat Sensor SounderThe GENT S4T-770-S Self-Test Optical Heat Multisensor with Integrated Sounder has a new IP21 external moulding new detector chamber design and a dual microprocessor PCB. This design delivers even better smoke detection and voice storage capacity. In addition the award-winning Self-Test feature allows both the heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Enables discrete functional testing and visual inspection of the fire alarm system by reducing the engineer toolset to just a mobile device phone or tablet. No more impact on building occupiers Tests both the heat and smoke sensors by heating the thermistor and introducing small amounts of smoke into the detection chamber Gently blows the smoke out of the detection chamber and smoke entry points to ensure they are not blocked Flexible testing options allow the engineer to test in different ways single device detection zone loops panels Allows up to 6 devices to be tested at once per loop and any number of loops can be tested simultaneously making the functional testing incredibly fast Device testing is fast enough to allow up to 4 functional tests to be performed per year for the lifespan of the device Eliminates all access issues when detector testing ensuring 100 functional testing is achieved Allows the system to remain active whilst testing as each detector is only offline for 60 seconds and outputs are not generated Any fires detected outside of the devices performing Self-Test will stop the Self-Test process and operate the fire systems Cause Effect Allows the engineer to easily locate the detector using the App and BLE to check the device number label zone description and detector type Allows simple device updates to be performed through the App including the correction of inaccurate device labels and loop mapping The app and BLE handshake verifies that the engineer has been within visual inspection range Optional Inspection prompt LEDs on the device let the engineer know what Self-Test devices need to be visually inspected and will automatically turn off when the visual inspection is complete Engineers can spend more time digitally capturing non-compliance issues and advising how to resolve them. This includes any issues causing false alarms Test Fire LED option in the App allows the fire LED to be tested a pending BS5839-1 testing requirement. This feature can additionally confirm that they are inspecting the correct device The CLSS App allows the engineer to simulate a fire and test the Cause Effect logic The CLSS App also allows the Cause Effect to be triggered through a successful Self-Test operation allowing a witness test to be performed using real smoke

GBP 134.18
1

Gent S4T-771-S S4 SELF TEST Dual Optical Heat Sensor amp Sounder

Gent S4T-771-S S4 SELF TEST Dual Optical Heat Sensor amp Sounder

Gent S4T-771-S S4 SELF TEST Dual Optical Heat Sensor SounderThe GENT S4T-771-S Self-Test Dual Optical Heat Multisensor with Integrated Sounder has a new IP21 external moulding new detector chamber design and a dual microprocessor PCB. This design delivers even better smoke detection and voice storage capacity. In addition the award-winning Self-Test feature allows both the heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Enables discrete functional testing and visual inspection of the fire alarm system by reducing the engineer toolset to just a mobile device phone or tablet. No more impact on building occupiers Tests both the heat and smoke sensors by heating the thermistor and introducing small amounts of smoke into the detection chamber Gently blows the smoke out of the detection chamber and smoke entry points to ensure they are not blocked Flexible testing options allow the engineer to test in different ways single device detection zone loops panels Allows up to 6 devices to be tested at once per loop and any number of loops can be tested simultaneously making the functional testing incredibly fast Device testing is fast enough to allow up to 4 functional tests to be performed per year for the lifespan of the device Eliminates all access issues when detector testing ensuring 100 functional testing is achieved Allows the system to remain active whilst testing as each detector is only offline for 60 seconds and outputs are not generated Any fires detected outside of the devices performing Self-Test will stop the Self-Test process and operate the fire systems Cause Effect Allows the engineer to easily locate the detector using the App and BLE to check the device number label zone description and detector type Allows simple device updates to be performed through the App including the correction of inaccurate device labels and loop mapping The app and BLE handshake verifies that the engineer has been within visual inspection range Optional Inspection prompt LEDs on the device let the engineer know what Self-Test devices need to be visually inspected and will automatically turn off when the visual inspection is complete Engineers can spend more time digitally capturing non-compliance issues and advising how to resolve them. This includes any issues causing false alarms Test Fire LED option in the App allows the fire LED to be tested a pending BS5839-1 testing requirement. This feature can additionally confirm that they are inspecting the correct device The CLSS App allows the engineer to simulate a fire and test the Cause Effect logic The CLSS App also allows the Cause Effect to be triggered through a successful Self-Test operation allowing a witness test to be performed using real smoke

GBP 156.26
1

Gent S4T-720 S4 SELF TEST Heat Sensor

Gent S4T-720 S4 SELF TEST Heat Sensor

Gent S4T-720 S4 SELF TEST Heat SensorThe GENT S4T-720 Self-Test Heat Sensor has a new IP21 external moulding new detector chamber design and a dual microprocessor PCB. This design delivers even better smoke detection and voice storage capacity. In addition the award-winning Self-Test feature allows both the heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Enables discrete functional testing and visual inspection of the fire alarm system by reducing the engineer toolset to just a mobile device phone or tablet. No more impact on building occupiers Tests both the heat and smoke sensors by heating the thermistor and introducing small amounts of smoke into the detection chamber Gently blows the smoke out of the detection chamber and smoke entry points to ensure they are not blocked Flexible testing options allow the engineer to test in different ways single device detection zone loops panels Allows up to 6 devices to be tested at once per loop and any number of loops can be tested simultaneously making the functional testing incredibly fast Device testing is fast enough to allow up to 4 functional tests to be performed per year for the lifespan of the device Eliminates all access issues when detector testing ensuring 100 functional testing is achieved Allows the system to remain active whilst testing as each detector is only offline for 60 seconds and outputs are not generated Any fires detected outside of the devices performing Self-Test will stop the Self-Test process and operate the fire systems Cause Effect Allows the engineer to easily locate the detector using the App and BLE to check the device number label zone description and detector type Allows simple device updates to be performed through the App including the correction of inaccurate device labels and loop mapping The app and BLE handshake verifies that the engineer has been within visual inspection range Optional Inspection prompt LEDs on the device let the engineer know what Self-Test devices need to be visually inspected and will automatically turn off when the visual inspection is complete Engineers can spend more time digitally capturing non-compliance issues and advising how to resolve them. This includes any issues causing false alarms Test Fire LED option in the App allows the fire LED to be tested a pending BS5839-1 testing requirement. This feature can additionally confirm that they are inspecting the correct device The CLSS App allows the engineer to simulate a fire and test the Cause Effect logic The CLSS App also allows the Cause Effect to be triggered through a successful Self-Test operation allowing a witness test to be performed using real smoke

GBP 100.21
1

Gent S4T-711 S4 SELF TEST Dual Optical Heat Sensor

Gent S4T-711 S4 SELF TEST Dual Optical Heat Sensor

Gent S4T-711 S4 SELF TEST Dual Optical Heat SensorThe S4T-711 Self-Test Dual Optical Heat Multisensor has a new IP21 external moulding new detector chamber design and a dual microprocessor PCB. This design delivers even better smoke detection and voice storage capacity. In addition the award-winning Self-Test feature allows both the heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Enables discrete functional testing and visual inspection of the fire alarm system by reducing the engineer toolset to just a mobile device phone or tablet. No more impact on building occupiers Tests both the heat and smoke sensors by heating the thermistor and introducing small amounts of smoke into the detection chamber Gently blows the smoke out of the detection chamber and smoke entry points to ensure they are not blocked Flexible testing options allow the engineer to test in different ways single device detection zone loops panels Allows up to 6 devices to be tested at once per loop and any number of loops can be tested simultaneously making the functional testing incredibly fast Device testing is fast enough to allow up to 4 functional tests to be performed per year for the lifespan of the device Eliminates all access issues when detector testing ensuring 100 functional testing is achieved Allows the system to remain active whilst testing as each detector is only offline for 60 seconds and outputs are not generated Any fires detected outside of the devices performing Self-Test will stop the Self-Test process and operate the fire systems Cause Effect Allows the engineer to easily locate the detector using the App and BLE to check the device number label zone description and detector type Allows simple device updates to be performed through the App including the correction of inaccurate device labels and loop mapping The app and BLE handshake verifies that the engineer has been within visual inspection range Optional Inspection prompt LEDs on the device let the engineer know what Self-Test devices need to be visually inspected and will automatically turn off when the visual inspection is complete Engineers can spend more time digitally capturing non-compliance issues and advising how to resolve them. This includes any issues causing false alarms Test Fire LED option in the App allows the fire LED to be tested a pending BS5839-1 testing requirement. This feature can additionally confirm that they are inspecting the correct device The CLSS App allows the engineer to simulate a fire and test the Cause Effect logic The CLSS App also allows the Cause Effect to be triggered through a successful Self-Test operation allowing a witness test to be performed using real smoke

GBP 121.45
1

Gent S4T-710 S4 SELF TEST Optical Heat Sensor

Gent S4T-710 S4 SELF TEST Optical Heat Sensor

Gent S4T-710 S4 SELF TEST Optical Heat SensorThe GENT S4T-710 Self-Test Optical Heat Multisensor has a new IP21 external moulding new detector chamber design and a dual microprocessor PCB. This design delivers even better smoke detection and voice storage capacity. In addition the award-winning Self-Test feature allows both the heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Tests both the heat and smoke sensors by heating the thermistor and introducing small amounts of smoke into the detection chamber Gently blows the smoke out of the detection chamber and smoke entry points to ensure they are not blocked Flexible testing options allow the engineer to test in different ways single device detection zone loops panels Allows up to 6 devices to be tested at once per loop and any number of loops can be tested simultaneously making the functional testing incredibly fast Device testing is fast enough to allow up to 4 functional tests to be performed per year for the lifespan of the device Eliminates all access issues when detector testing ensuring 100 functional testing is achieved Allows the system to remain active whilst testing as each detector is only offline for 60 seconds and outputs are not generated Any fires detected outside of the devices performing Self-Test will stop the Self-Test process and operate the fire systems Cause Effect Allows the engineer to easily locate the detector using the App and BLE to check the device number label zone description and detector type Allows simple device updates to be performed through the App including the correction of inaccurate device labels and loop mapping The app and BLE handshake verifies that the engineer has been within visual inspection range Optional Inspection prompt LEDs on the device let the engineer know what Self-Test devices need to be visually inspected and will automatically turn off when the visual inspection is complete Engineers can spend more time digitally capturing non-compliance issues and advising how to resolve them. This includes any issues causing false alarms Test Fire LED option in the App allows the fire LED to be tested a pending BS5839-1 testing requirement. This feature can additionally confirm that they are inspecting the correct device The CLSS App allows the engineer to simulate a fire and test the Cause Effect logic The CLSS App also allows the Cause Effect to be triggered through a successful Self-Test operation allowing a witness test to be performed using real smoke

GBP 105.31
1

Gent VIG-NC-V3 Network Card V3

Gent S4-34760 Duct Housing

Gent S4-34760 Duct Housing

Gent S4-34760 Duct HousingIncluding S-Quad Base and 0.6M TubeAn optical smoke sensor specifically designed for use in ventilation ducting. A venturi probe samples the air in the duct for smoke. Detector housing is mounted externally to the duct. This device can trigger the shut-down of an air-conditioning or ventilation plant to prevent the spread of smoke.Unfortunately air ducts do not just guarantee fresh air but in the event of a fi re they can also deliver toxic smoke from the fire source to distant area via the exhaust air system. Therefore air ducts must be monitored.The Gent duct sensor housing offers effective protection which is easy to install and maintain. The Gent duct sensor housing is supplied complete with an S Quad Sensor base and is thus compatible with the full range of S-Quad detectors S4-911 in high sensitivity state is recommended. The housing is mounted on the outside of the air duct. A Venturi pipe 0.6m 1.5m or 2.8m is inserted into the duct and delivers air from the duct through detection chamber and back to the duct. An air fl ow indicator shows whether there is an airflow through the housing.A maintenance hole in the transparent cover allows test spray to be applied without opening the cover. Using the Venturi effect means that a single sampling tube can be used and air velocities of as little as 1 Metre a second can be sensed. A mounting bracket is also available to mount the detector on circular and insulated ducts.The housing can be mounted in any orientation. The arrow shape design can be mounted in any orientation. The arrow shape design of the tough grey abs housing shows the direction of flow thus making installation quick and simple.Key FeaturesDirection of flow indicated by housingSingle sampling tubeCompatible with S-Quad SensorsSampling tubes available in three lengthsMounting bracket availableRemote LED can be installed via S-Quad monitor outputAir Duct uses Venturi processFully integrated into Vigilon loop

GBP 738.02
1

Gent NANO-24 Nano Control Panel

GBP 540.34
1

Gent 805595.10 Wireless Transceiver Interface

Gent 805595.10 Wireless Transceiver Interface

Gent 805595.10 Wireless Transceiver InterfaceThis wireless transponder is designed for wall mounting. The wireless transponder communicates with up to 32 other wireless devices. These can be wireless of various types from intelligent automatic fire detectors or wireless interfaces with manual call points andor alarm signalling devices of the IQ8-family. Using the System IQ8ControlFlexES Control the wireless transponder integrates the intelligent automatic detectors with and without alarm signalling devices manual call point and IQ8Alarm Plus signalling devices in the esserbus esserbus-PLus via the wireless base andor wireless interface.The detector base allows esserbus integration of intelligent automatic detectors as bus devices with individual addressing via the transponder. Up to 10 transponders can be operated on one loop. The transponder can be linked with the loop as well as with a conventional detector zone or it can be operated as a stand-alone unit. Potential-free outputs for common fault and common fire are available. For system 8000 the transponder for RF devices can only be connected by using a potential-free relay to 4 IN2 OUT or 1 IN transponder because it is not compatible with panel 8000 and it cannot be used as a bus device.Key FeaturesRF communication with up to 32 usersmaximum 32 wireless basesmaximum 10 wireless interfaces with IQ8MCP manual call pointsmaximum 10 control groups for wireless interface with IQ8QuadIQ8Alarm Plus alarm signalling devicesesserbus integration of all RF. Devices as individually addressable usersThe RF devices can be assigned in up to 32 detector zonesAlarm and fault transmission in accordance with EN 54-2Connection to esserbus of IQ8Control FlexES Control panels as bus device as well as to a conventional detector zonesStand-alone operationPotential-free outputs for common fault and common fire

GBP 1502.39
1

Gent 14111-99 1102 Round Call Point Glass Pack of 10

Gent S4 Dual Optical Heat Sensor Black Body S4BK-711

Gent S4 Dual Optical Heat Sensor Black Body S4BK-711

Gent S4 Dual Optical Heat Sensor Black Body S4BK-711The S4BK-711 from the Gent range is a S4 Dual Optical Heat Sensor Black Body.The S4BK-711-V Dual Optical Black Heat Sensor with Voice is a Gent Vigilon S-Quad sensor with a unique combination of sensing elements to provide quick intelligent fire decisions. Smoke detection is enhanced using patented dual optical scatter technology. This allows it to be configured to filter specific risks such as steam and dust resulting in significantly reduced false alarms.Voice messages stored on a memory chip in the sensor can be triggered to give clearly understood messages leading to quicker and safer evacuation.A new concept in fire detection a truly intelligent analogue sensor combining exceptional computing power in the sensor as well as the panel to achieve an extremely fast response to a real fire whilst minimising the risk of false alarms.Key FeaturesThe multi-sensor combines heat H carbon monoxide CO optical forward scatter OFS and optical backward scatter OBSThe patented dual angle optical scatter technology allows identification of the particle source filtering potential false alarms due to steam and dustThe gas sensing element CO within the chamber monitors the concentration of carbon monoxide a product of incomplete combustion in some fire types and potentially life threatening. The CO sensor allows rapid fire detection with smouldering fires in areas where smoke detectors could register false alarmsCombined CO gas sensing with dual angle optical and heat allows a higher level of false alarm immunity whilst still improving the detection speed of certain types of fireEach sensor element has sensitivity settings which can be adjusted to suit the environment application and can be programmed for different time periods during the day or nightRepeat fire LED output as standard if monitored input not usedOperational LED blink OnOff optionMonitored Input - which can be Fire Fault or Supervisory

GBP 136.74
1

Gent S4T-711-V-VAD-HPR S4 SELF TEST Dual Optical Heat Sensor amp Voice Sounder amp High Power Red

Gent S4T-711-V-VAD-HPR S4 SELF TEST Dual Optical Heat Sensor amp Voice Sounder amp High Power Red

Gent S4T-711-V-VAD-HPR S4 SELF TEST Dual Optical Heat Sensor Voice Sounder High Power RedThis device has a new IP21 external moulding new detector chamber design anda dual microprocessor PCB. This design delivers even better smoke detection andvoice storage capacity. In addition the award-winning Self-Test feature allows boththe heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Available in a large range of multi-sensorPart-23 VAD and sounder voice options. Enables discrete functional testing andvisual inspection of the fire alarm systemby reducing the engineer toolset to justa mobile device phone or tablet. Nomore impact on building occupiers. Tests both the heat and smokesensors by heating the thermistorand introducing small amounts ofsmoke into the detection chamber. Gently blows the smoke out of thedetection chamber and smoke entrypoints to ensure they are not blocked. Flexible testing options allow the engineerto test in different ways single devicedetection zone loops panels. Allows up to 6 devices to be tested atonce per loop and any number of loopscan be tested simultaneously makingthe functional testing incredibly fast. Device testing is fast enough to allowup to 4 functional tests to be performedper year for the lifespan of the device. Eliminates all access issues whendetector testing ensuring 100functional testing is achieved. Allows the system to remain active whilsttesting as each detector is only offline for60 seconds and outputs are not generated. Any fires detected outside of thedevices performing Self-Test will stopthe Self-Test process and operatethe fire systems Cause Effect. Allows the engineer to easily locatethe detector using the App and BLEto check the device number labelzone description and detector type. Allows simple device updates tobe performed through the Appincluding the correction of inaccuratedevice labels and loop mapping. The app and BLE handshakeverifies that the engineer has beenwithin visual inspection range. Optional Inspection prompt LEDs onthe device let the engineer know whatSelf-Test devices need to be visuallyinspected and will automatically turn offwhen the visual inspection is complete. Engineers can spend more time digitallycapturing non-compliance issues andadvising how to resolve them. Thisincludes any issues causing false alarms. Test Fire LED option in the App allowsthe fire LED to be tested a pendingBS5839-1 testing requirement. Thisfeature can additionally confirm thatthey are inspecting the correct device. The CLSS App allows the engineerto simulate a fire and test theCause Effect logic. The CLSS App also allows theCause Effect to be triggeredthrough a successful Self-Testoperation allowing a witness test tobe performed using real smoke.

GBP 235.25
1

Gent S4T-720-V-VAD-HPR S4 SELF TEST Heat Sensor amp Voice Sounder amp High Power Red VAD

Gent S4T-720-V-VAD-HPR S4 SELF TEST Heat Sensor amp Voice Sounder amp High Power Red VAD

Gent S4T-720-V-VAD-HPR S4 SELF TEST Heat Sensor Voice Sounder High Power Red VADThis device has a new IP21 external moulding new detector chamber design anda dual microprocessor PCB. This design delivers even better smoke detection andvoice storage capacity. In addition the award-winning Self-Test feature allows boththe heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Available in a large range of multi-sensorPart-23 VAD and sounder voice options. Enables discrete functional testing andvisual inspection of the fire alarm systemby reducing the engineer toolset to justa mobile device phone or tablet. Nomore impact on building occupiers. Tests both the heat and smokesensors by heating the thermistorand introducing small amounts ofsmoke into the detection chamber. Gently blows the smoke out of thedetection chamber and smoke entrypoints to ensure they are not blocked. Flexible testing options allow the engineerto test in different ways single devicedetection zone loops panels. Allows up to 6 devices to be tested atonce per loop and any number of loopscan be tested simultaneously makingthe functional testing incredibly fast. Device testing is fast enough to allowup to 4 functional tests to be performedper year for the lifespan of the device. Eliminates all access issues whendetector testing ensuring 100functional testing is achieved. Allows the system to remain active whilsttesting as each detector is only offline for60 seconds and outputs are not generated. Any fires detected outside of thedevices performing Self-Test will stopthe Self-Test process and operatethe fire systems Cause Effect. Allows the engineer to easily locatethe detector using the App and BLEto check the device number labelzone description and detector type. Allows simple device updates tobe performed through the Appincluding the correction of inaccuratedevice labels and loop mapping. The app and BLE handshakeverifies that the engineer has beenwithin visual inspection range. Optional Inspection prompt LEDs onthe device let the engineer know whatSelf-Test devices need to be visuallyinspected and will automatically turn offwhen the visual inspection is complete. Engineers can spend more time digitallycapturing non-compliance issues andadvising how to resolve them. Thisincludes any issues causing false alarms. Test Fire LED option in the App allowsthe fire LED to be tested a pendingBS5839-1 testing requirement. Thisfeature can additionally confirm thatthey are inspecting the correct device. The CLSS App allows the engineerto simulate a fire and test theCause Effect logic. The CLSS App also allows theCause Effect to be triggeredthrough a successful Self-Testoperation allowing a witness test tobe performed using real smoke.

GBP 189.40
1

Gent S4T-711-V S4 SELF TEST Dual Optical Heat Sensor amp Voice Sounder

Gent S4T-711-V S4 SELF TEST Dual Optical Heat Sensor amp Voice Sounder

Gent S4T-711-V S4 SELF TEST Dual Optical Heat Sensor Voice SounderThis device has a new IP21 external moulding new detector chamber design anda dual microprocessor PCB. This design delivers even better smoke detection andvoice storage capacity. In addition the award-winning Self-Test feature allows boththe heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Available in a large range of multi-sensorPart-23 VAD and sounder voice options. Enables discrete functional testing andvisual inspection of the fire alarm systemby reducing the engineer toolset to justa mobile device phone or tablet. Nomore impact on building occupiers. Tests both the heat and smokesensors by heating the thermistorand introducing small amounts ofsmoke into the detection chamber. Gently blows the smoke out of thedetection chamber and smoke entrypoints to ensure they are not blocked. Flexible testing options allow the engineerto test in different ways single devicedetection zone loops panels. Allows up to 6 devices to be tested atonce per loop and any number of loopscan be tested simultaneously makingthe functional testing incredibly fast. Device testing is fast enough to allowup to 4 functional tests to be performedper year for the lifespan of the device. Eliminates all access issues whendetector testing ensuring 100functional testing is achieved. Allows the system to remain active whilsttesting as each detector is only offline for60 seconds and outputs are not generated. Any fires detected outside of thedevices performing Self-Test will stopthe Self-Test process and operatethe fire systems Cause Effect. Allows the engineer to easily locatethe detector using the App and BLEto check the device number labelzone description and detector type. Allows simple device updates tobe performed through the Appincluding the correction of inaccuratedevice labels and loop mapping. The app and BLE handshakeverifies that the engineer has beenwithin visual inspection range. Optional Inspection prompt LEDs onthe device let the engineer know whatSelf-Test devices need to be visuallyinspected and will automatically turn offwhen the visual inspection is complete. Engineers can spend more time digitallycapturing non-compliance issues andadvising how to resolve them. Thisincludes any issues causing false alarms. Test Fire LED option in the App allowsthe fire LED to be tested a pendingBS5839-1 testing requirement. Thisfeature can additionally confirm thatthey are inspecting the correct device. The CLSS App allows the engineerto simulate a fire and test theCause Effect logic. The CLSS App also allows theCause Effect to be triggeredthrough a successful Self-Testoperation allowing a witness test tobe performed using real smoke.

GBP 190.24
1

Gent S4TB-711-V-VAD-HPR S4 SELF TEST Black Dual Optical Heat Sensor amp Voice Sounder amp High Power Red VAD - Black

Gent S4TB-711-V-VAD-HPR S4 SELF TEST Black Dual Optical Heat Sensor amp Voice Sounder amp High Power Red VAD - Black

Gent S4TB-711-V-VAD-HPR S4 SELF TEST Black Dual Optical Heat Sensor Voice Sounder High Power Red VAD - BlackThis device has a new IP21 external moulding new detector chamber design anda dual microprocessor PCB. This design delivers even better smoke detection andvoice storage capacity. In addition the award-winning Self-Test feature allows boththe heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Available in a large range of multi-sensorPart-23 VAD and sounder voice options. Enables discrete functional testing andvisual inspection of the fire alarm systemby reducing the engineer toolset to justa mobile device phone or tablet. Nomore impact on building occupiers. Tests both the heat and smokesensors by heating the thermistorand introducing small amounts ofsmoke into the detection chamber. Gently blows the smoke out of thedetection chamber and smoke entrypoints to ensure they are not blocked. Flexible testing options allow the engineerto test in different ways single devicedetection zone loops panels. Allows up to 6 devices to be tested atonce per loop and any number of loopscan be tested simultaneously makingthe functional testing incredibly fast. Device testing is fast enough to allowup to 4 functional tests to be performedper year for the lifespan of the device. Eliminates all access issues whendetector testing ensuring 100functional testing is achieved. Allows the system to remain active whilsttesting as each detector is only offline for60 seconds and outputs are not generated. Any fires detected outside of thedevices performing Self-Test will stopthe Self-Test process and operatethe fire systems Cause Effect. Allows the engineer to easily locatethe detector using the App and BLEto check the device number labelzone description and detector type. Allows simple device updates tobe performed through the Appincluding the correction of inaccuratedevice labels and loop mapping. The app and BLE handshakeverifies that the engineer has beenwithin visual inspection range. Optional Inspection prompt LEDs onthe device let the engineer know whatSelf-Test devices need to be visuallyinspected and will automatically turn offwhen the visual inspection is complete. Engineers can spend more time digitallycapturing non-compliance issues andadvising how to resolve them. Thisincludes any issues causing false alarms. Test Fire LED option in the App allowsthe fire LED to be tested a pendingBS5839-1 testing requirement. Thisfeature can additionally confirm thatthey are inspecting the correct device. The CLSS App allows the engineerto simulate a fire and test theCause Effect logic. The CLSS App also allows theCause Effect to be triggeredthrough a successful Self-Testoperation allowing a witness test tobe performed using real smoke.

GBP 319.33
1

Gent S4T-711-VAD-HPR S4 SELF TEST Dual Optical Heat Sensor amp High Power Red VAD

Gent S4T-711-VAD-HPR S4 SELF TEST Dual Optical Heat Sensor amp High Power Red VAD

Gent S4T-711-VAD-HPR S4 SELF TEST Dual Optical Heat Sensor High Power Red VADThis device has a new IP21 external moulding new detector chamber design anda dual microprocessor PCB. This design delivers even better smoke detection andvoice storage capacity. In addition the award-winning Self-Test feature allows boththe heat and optical sensors within the device to be tested using the CLSS app.The Self-Test patented design performs real sensor tests by heating the heat sensing thermistor and generating real aerosol smoke to test the optical sensor. The small fan within the device gently blows the aerosol from the detection chamber through the detectors smoke entry points into the room. This method simulates a more realistic fire test than many traditional testing methods ensuring that the smoke entry points are not blocked and able to detect a real fire.Each device also incorporates Bluetooth Low Energy BLE. When activated BLE acts like a beacon in each detector that can be automatically detected by a mobile device using the CLSS app. This has many helpful features such as finding a device automatically ensuring the device details are correct and proving that an engineer has been within the visual inspection range.Key Features Available in a large range of multi-sensorPart-23 VAD and sounder voice options. Enables discrete functional testing andvisual inspection of the fire alarm systemby reducing the engineer toolset to justa mobile device phone or tablet. Nomore impact on building occupiers. Tests both the heat and smokesensors by heating the thermistorand introducing small amounts ofsmoke into the detection chamber. Gently blows the smoke out of thedetection chamber and smoke entrypoints to ensure they are not blocked. Flexible testing options allow the engineerto test in different ways single devicedetection zone loops panels. Allows up to 6 devices to be tested atonce per loop and any number of loopscan be tested simultaneously makingthe functional testing incredibly fast. Device testing is fast enough to allowup to 4 functional tests to be performedper year for the lifespan of the device. Eliminates all access issues whendetector testing ensuring 100functional testing is achieved. Allows the system to remain active whilsttesting as each detector is only offline for60 seconds and outputs are not generated. Any fires detected outside of thedevices performing Self-Test will stopthe Self-Test process and operatethe fire systems Cause Effect. Allows the engineer to easily locatethe detector using the App and BLEto check the device number labelzone description and detector type. Allows simple device updates tobe performed through the Appincluding the correction of inaccuratedevice labels and loop mapping. The app and BLE handshakeverifies that the engineer has beenwithin visual inspection range. Optional Inspection prompt LEDs onthe device let the engineer know whatSelf-Test devices need to be visuallyinspected and will automatically turn offwhen the visual inspection is complete. Engineers can spend more time digitallycapturing non-compliance issues andadvising how to resolve them. Thisincludes any issues causing false alarms. Test Fire LED option in the App allowsthe fire LED to be tested a pendingBS5839-1 testing requirement. Thisfeature can additionally confirm thatthey are inspecting the correct device. The CLSS App allows the engineerto simulate a fire and test theCause Effect logic. The CLSS App also allows theCause Effect to be triggeredthrough a successful Self-Testoperation allowing a witness test tobe performed using real smoke.

GBP 192.79
1

Gent S4-34845 Manual Call Point with Protective Cover amp Resettable Element