101 results (0,15038 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Global Fire ZEOS-AD-SH Addressable Multisensor Detector with Dipswitch

Global Fire ZEOS-AD-S Addressable Smoke Detector with Dipswitch

Global Fire ZEOS-AD-H Addressable Heat Detector with Dipswitch

Global Fire Equipment ZEOS-AD-HBLK ZEOS Addressable Heat Detector Black

Global Fire Equipment ZEOS-AD-SBLK ZEOS Addressable Smoke Detector Black

Global Fire Equipment ORION-RS232 RS232 Network Communication Card

Global Fire Equipment GFE-SWR-UVIR Sense-Ware UVIR Flame Detector

Global Fire Equipment GFE-SWR-UV Sense-Ware UV Flame Detector

Global Fire Equipment BCM-ORION 28V DC 1A Battery Charger cw Sounder Circuit

Global Fire Orion 4 Zone Conventional Fire Alarm Control Panel

Global Fire Orion 4 Zone Conventional Fire Alarm Control Panel

The ORION conventional control panel range offers a creatively designed and visually pleasing solution for smaller cost-conscious projects demanding simplicity of operation. Versions available include 2 4 and 8 zone panels and two styles of repeater. The outstanding programmable features included in this panel range contradict the facilities commonly availablein this type of panel and include programmable time delay by zone DayNight mode selectable non-latching zones and coincidence detection. Operation is extremely intuitive offering simple control and one-button disablement facilities as well as the one man test mode which provides simple and efficient testing of the system.Advanced configuration solutions include the following a dedicated RS232 communication interface allowing connection of up to 4 remote repeater panels addressable loop interface modules and multiplexed zonal output relays giving one of the most highly advanced levels of system integration and compatibility existing on the market at this level.Key Features2 4 and 8 Zone non-expandable control panelsUp to 32 conventional smoke andor heat detectors per ZoneActive End of Line monitoringProgrammable non-latching ZonesDelay timer programmable onoff per ZoneCoincidence programmable for adjacent ZonesOne man testSupervised auxiliary 24 volt output2 Supervised monitored sounder circuits3 Remote inputs used for activation of Class Change DayNight mode and Reset2 Relay outputs fire and faultFully EN54 part 2 and 4 compliantRepeater outputMultiplexed output for LEDs and additional relay outputs per zone GFE-MPX-RELMultiplexed output for sounders per zone GFE-MPX-SNDRAddressable Loop Interface card GFE-ADLI

GBP 132.25
1

Global Fire Equipment GFE-SWR-IR3 Sense-Ware IR3 Flame Detector

Global Fire Orion 2 Zone Conventional Fire Alarm Control Panel

Global Fire Orion 2 Zone Conventional Fire Alarm Control Panel

Global Fire Orion 2 Zone Conventional Fire Alarm Control PanelThe ORION conventional control panel range offers a creatively designed and visually pleasing solution for smaller cost-conscious projects demanding simplicity of operation. Versions available include 2 4 and 8 zone panels and two styles of repeater. The outstanding programmable features included in this panel range contradict the facilities commonly availablein this type of panel and include programmable time delay by zone DayNight mode selectable non-latching zones and coincidence detection. Operation is extremely intuitive offering simple control and one-button disablement facilities as well as the one man test mode which provides simple and efficient testing of the system.Advanced configuration solutions include the following a dedicated RS232 communication interface allowing connection of up to 4 remote repeater panels addressable loop interface modules and multiplexed zonal output relays giving one of the most highly advanced levels of system integration and compatibility existing on the market at this level.Key Features2 4 and 8 Zone non-expandable control panelsUp to 32 conventional smoke andor heat detectors per ZoneActive End of Line monitoringProgrammable non-latching ZonesDelay timer programmable onoff per ZoneCoincidence programmable for adjacent ZonesOne man testSupervised auxiliary 24 volt output2 Supervised monitored sounder circuits3 Remote inputs used for activation of Class Change DayNight mode and Reset2 Relay outputs fire and faultFully EN54 part 2 and 4 compliantRepeater outputMultiplexed output for LEDs and additional relay outputs per zone GFE-MPX-RELMultiplexed output for sounders per zone GFE-MPX-SNDRAddressable Loop Interface card GFE-ADLI

GBP 111.11
1

Global Fire Orion 8 Zone Conventional Fire Alarm Control Panel

Global Fire Orion 8 Zone Conventional Fire Alarm Control Panel

Global Fire Orion 8 Zone Conventional Fire Alarm Control PanelThe ORION conventional control panel range offers a creatively designed and visually pleasing solution for smaller cost-conscious projects demanding simplicity of operation. Versions available include 2 4 and 8 zone panels and two styles of repeater. The outstanding programmable features included in this panel range contradict the facilities commonly availablein this type of panel and include programmable time delay by zone DayNight mode selectable non-latching zones and coincidence detection. Operation is extremely intuitive offering simple control and one-button disablement facilities as well as the one man test mode which provides simple and efficient testing of the system.Advanced configuration solutions include the following a dedicated RS232 communication interface allowing connection of up to 4 remote repeater panels addressable loop interface modules and multiplexed zonal output relays giving one of the most highly advanced levels of system integration and compatibility existing on the market at this level.Key Features2 4 and 8 Zone non-expandable control panelsUp to 32 conventional smoke andor heat detectors per ZoneActive End of Line monitoringProgrammable non-latching ZonesDelay timer programmable onoff per ZoneCoincidence programmable for adjacent ZonesOne man testSupervised auxiliary 24 volt output2 Supervised monitored sounder circuits3 Remote inputs used for activation of Class Change DayNight mode and Reset2 Relay outputs fire and faultFully EN54 part 2 and 4 compliantRepeater outputMultiplexed output for LEDs and additional relay outputs per zone GFE-MPX-RELMultiplexed output for sounders per zone GFE-MPX-SNDRAddressable Loop Interface card GFE-ADLI

GBP 203.68
1

Global Fire Valkyrie CS Conventional Red Wall Sounder

Global Fire Equipment OWL-6-OFFLINE OWL Graphical Software 6 Panels Offline

Global Fire Valkyrie CSB Conventional Red Wall Mount Sounder Beacon

Global Fire Equipment VALKYRIE-CSWHT Valkyrie Conventional Wall Mount Sounder White

Global Fire Equipment MAMYEL-VAD Manually Addressed Module for Conventional VADs

Global Fire Valkyrie CS IP65 Conventional Red Sounder

Global Fire Equipment OWL-2-5-OFFLINE OWL Graphical Software - 2 -5 Panels Offline

Global Fire Equipment OWL-1-ONLINE OWL Graphical Software - 1 Panel Online

Global Fire Equipment OWL-1-OFFLINE OWL Graphical Software - 1 Panel Offline

Global Fire Equipment OWL-2-5-ONLINE OWL Graphical Software - 2 -5 Panels Online