83 results (0,14142 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Global Fire VALKYRIE-ASBWHT VALKYRIE Addressable Wall Mount Sounder Beacon White

Global Fire VALKYRIE-ASBBLK VALKYRIE Addressable Wall Mount Sounder Beacon Black

Global Fire Equipment VALKYRIE-ASBLK Valkyrie AS Addressable Wall Sounder - Black

Global Fire Valkyrie ASB Addressable Red Wall Sounder Beacon

Global Fire Valkyrie AS Addressable Red Wall Sounder

Global Fire VALKYRIE-ASWHT VALKYRIE Addressable Wall Mount Sounder White

Global Fire Valkyrie ASI IP65 Addressable Red Sounder with Isolator

Global Fire Valkyrie AB Addressable Red Beacon

Global Fire Valkyrie ABI IP65 Addressable Red Beacon with Isolator

Zeta ZIOU230 Interface Module Loop Powered 5.0A Rating

Zeta ZIOU230 Interface Module Loop Powered 5.0A Rating

Zeta ZIOU230 Interface Module Loop Powered 5.0A RatingThe Mains IO Modules are fully monitored loop powered devices which permit the interfacing of third-party equipment with the Fire Alarm Control panel using normally open dry contact connections.The connection to the input is monitored for fault open or short circuit and Alarm conditions.The interface is used to monitor the contacts of an external system which must be interfaced to the Fire Alarm System for example a Flow Switch in a sprinkler system to indicate if the sprinklers have been activated or extinguishant level monitoring in Gas Extinguishing systems etc.Module is provided with a loop short-circuit isolator and with a voltage free single pole change over mains rated output.The output relay is always powered directly from the detection loop. It is not required to use an external 24V DC power supply. Relay operation is confirmed by an on-board red LED. An 8 way D.I.L switch is provided to configure the modules address.This value can be set in the range 1 to 125. The following programmable functions are available Input Activation Mode Delayed Input Alarm Activation Output Delayed Activation.The Simplicity CO 8 range is designed to detect monitor CO concentrations in places such as warehouses car parks tunnels and enclosed buildings where forklifts cars and delivery trucks can produce deadly amounts of carbon monoxide in high traffic areas Carbon Monoxide can accumulate in these areas and can be a serious safety and health concern.Key FeaturesFast Activation ResponseLoop PoweredFive Status LEDs providedLow Power ConsumptionModule features an integral short-circuit loop isolatorSingle mains rated relay contact

GBP 78.77
1

Global Fire ZEOS-C-S Conventional Photoelectric Smoke Detector

Global Fire ZEOS-C-H Conventional Heat Detector

Global Fire ZEOS-C-SH Conventional Multisensor Detector

Global Fire ZEOS-AD-H Addressable Heat Detector with Dipswitch

Global Fire ZEOS-AD-SH Addressable Multisensor Detector with Dipswitch

Global Fire ZEOS-AD-S Addressable Smoke Detector with Dipswitch

Global Fire Equipment ZEOS-AD-HBLK ZEOS Addressable Heat Detector Black

Global Fire Equipment ZEOS-AD-SBLK ZEOS Addressable Smoke Detector Black

Global Fire Equipment OCTO-PRINTER OCTO Printer Assembly

Global Fire OCTO-4 Loop Control Panel

Global Fire OCTO-4 Loop Control Panel

Global Fire OCTO-4 Loop Control PanelThe OCTO Fire Alarm Control Panel is built on the pedigree of the worldwide known JUNO NET. Now featuring a fully peer-to-peer multi-master networking solution.This new Chameleon Network solution enables extreme resilience in very large distributed systems. On a Chameleon Network system each network NODE has in its internal configuration memory the whole system information i.e. in the unlikely event of a communication loss there is no performance degradation of individual NODE.The network layout is usually configured in a closed loop or having physical multi-paths for communications redundancy which can use either RS422 or Fibre-Optic mediums.It can also use Ethernet interfaces which can use the existing networking infrastructure.A Chameleon Network can accommodate up to 32 NODE. Each OCTO panel can support from 1 to 4 addressable loops giving a total of 128 loops in a single systemNaturally it also supports remote access with our proprietary ODYSSEY Graphics Interface as well as integration with third party Building Management Systems through a Modbus output.The graphic backlit LCD display accommodates any type of custom characters or graphic symbols allowing multi-language support as well as pictorial and customisable elements.Housed in an aluminium back box with a reversible plastic lid it comprises a PSU a Front End Display for visualisation of the CI equipment status a NODE unit with the loop card fitted and networking interfaces if necessary.For each 4 loops there is space for installing up to 12 AH 24V DC Sealed Lead Acid backup batteries more than enough to provide up to 24 H battery supply to the NODE and ZEOS associated devices which boast extremely low current consumption.Take into account that all networked panels share the complete system knowledge. On a multi OCTO networked panels as far as the network architecture is concerned if no human-machine Interface is needed at a specific location instead of using a complete OCTO panel with display built in a simple NODE panel can be used.By having the same 4 Loops available and housed in the same aluminium back box without the Front End Display built in the lid the NODE offers the possibility to extend the system keeping the human interface access only available at specific locations.In addition to this each NODE has provision to communicate with a remote Repeater unit using any of the networking interfaces.The Cause and Effect programming as well as customer specific Configurations can be uploaded to any OCTO panel in the network using the CHAMELEON CONNECTOR software tool. This is done by USB connection. Later the updated panel can broadcast the same configuration to all other Chameleon Network panels.Key Features1 to 4 loops panelUp to 250 devices per loop 125 address limitUp to 95 VULCAN 2 addressable ultra low current base sounders 32 address limitSupports connection to Repeaters via RS422 Fibre-Optic or TCPIPNetworked system up to 128 loopsChameleon Peer-to-Peer Advanced Networking Protocol with up to 32 NODE32 individually programmable sounder addressesSupport of Non-European languages Mandarin Arabic Hindu Urdu Farsi etc.Full Self-Addressable Devices supportBuilt in Fire Fault relays2 conventional alarm outputs individually programmableDetection loops monitored for integrity384 fully programmable multi loop zones512 fully programmable sounder groups512 IO groupsEvent log rolling 10000 entriesRemovable Chassis

GBP 1446.26
1

Global Fire OCTO-2 OCTO 2 Loop Control Panel

Global Fire OCTO-2 OCTO 2 Loop Control Panel

Global Fire OCTO-2 OCTO 2 Loop Control PanelThe OCTO Fire Alarm Control Panel is built on the pedigree of the worldwide known JUNO NET. Now featuring a fully peer-to-peer multi-master networking solution.This new Chameleon Network solution enables extreme resilience in very large distributed systems. On a Chameleon Network system each network NODE has in its internal configuration memory the whole system information i.e. in the unlikely event of a communication loss there is no performance degradation of individual NODE.The network layout is usually configured in a closed loop or having physical multi-paths for communications redundancy which can use either RS422 or Fibre-Optic mediums.It can also use Ethernet interfaces which can use the existing networking infrastructure.A Chameleon Network can accommodate up to 32 NODE. Each OCTO panel can support from 1 to 4 addressable loops giving a total of 128 loops in a single systemNaturally it also supports remote access with our proprietary ODYSSEY Graphics Interface as well as integration with third party Building Management Systems through a Modbus output.The graphic backlit LCD display accommodates any type of custom characters or graphic symbols allowing multi-language support as well as pictorial and customisable elements.Housed in an aluminium back box with a reversible plastic lid it comprises a PSU a Front End Display for visualisation of the CI equipment status a NODE unit with the loop card fitted and networking interfaces if necessary.For each 4 loops there is space for installing up to 12 AH 24V DC Sealed Lead Acid backup batteries more than enough to provide up to 24 H battery supply to the NODE and ZEOS associated devices which boast extremely low current consumption.Take into account that all networked panels share the complete system knowledge. On a multi OCTO networked panels as far as the network architecture is concerned if no human-machine Interface is needed at a specific location instead of using a complete OCTO panel with display built in a simple NODE panel can be used.By having the same 4 Loops available and housed in the same aluminium back box without the Front End Display built in the lid the NODE offers the possibility to extend the system keeping the human interface access only available at specific locations.In addition to this each NODE has provision to communicate with a remote Repeater unit using any of the networking interfaces.The Cause and Effect programming as well as customer specific Configurations can be uploaded to any OCTO panel in the network using the CHAMELEON CONNECTOR software tool. This is done by USB connection. Later the updated panel can broadcast the same configuration to all other Chameleon Network panels.Key Features1 to 4 loops panelUp to 250 devices per loop 125 address limitUp to 95 VULCAN 2 addressable ultra low current base sounders 32 address limitSupports connection to Repeaters via RS422 Fibre-Optic or TCPIPNetworked system up to 128 loopsChameleon Peer-to-Peer Advanced Networking Protocol with up to 32 NODE32 individually programmable sounder addressesSupport of Non-European languages Mandarin Arabic Hindu Urdu Farsi etc.Full Self-Addressable Devices supportBuilt in Fire Fault relays2 conventional alarm outputs individually programmableDetection loops monitored for integrity384 fully programmable multi loop zones512 fully programmable sounder groups512 IO groupsEvent log rolling 10000 entriesRemovable Chassis

GBP 1157.02
1

Global Fire Equipment OCTO-4BLK 4 Loop Control Panel - Anthracite

Global Fire Equipment OCTO-4BLK 4 Loop Control Panel - Anthracite

Global Fire Equipment OCTO-4BLK 4 Loop Control Panel - AnthraciteThe OCTO Fire Alarm Control Panel is built on the pedigree of the worldwide known JUNO NET. Now featuring a fully peer-to-peer multi-master networking solution.This new Chameleon Network solution enables extreme resilience in very large distributed systems. On a Chameleon Network system each network NODE has in its internal configuration memory the whole system information i.e. in the unlikely event of a communication loss there is no performance degradation of individual NODE.The network layout is usually configured in a closed loop or having physical multi-paths for communications redundancy which can use either RS422 or Fibre-Optic mediums.It can also use Ethernet interfaces which can use the existing networking infrastructure.A Chameleon Network can accommodate up to 32 NODE. Each OCTO panel can support from 1 to 4 addressable loops giving a total of 128 loops in a single systemNaturally it also supports remote access with our proprietary ODYSSEY Graphics Interface as well as integration with third party Building Management Systems through a Modbus output.The graphic backlit LCD display accommodates any type of custom characters or graphic symbols allowing multi-language support as well as pictorial and customisable elements.Housed in an aluminium back box with a reversible plastic lid it comprises a PSU a Front End Display for visualisation of the CI equipment status a NODE unit with the loop card fitted and networking interfaces if necessary.For each 4 loops there is space for installing up to 12 AH 24V DC Sealed Lead Acid backup batteries more than enough to provide up to 24 H battery supply to the NODE and ZEOS associated devices which boast extremely low current consumption.Take into account that all networked panels share the complete system knowledge. On a multi OCTO networked panels as far as the network architecture is concerned if no human-machine Interface is needed at a specific location instead of using a complete OCTO panel with display built in a simple NODE panel can be used.By having the same 4 Loops available and housed in the same aluminium back box without the Front End Display built in the lid the NODE offers the possibility to extend the system keeping the human interface access only available at specific locations.In addition to this each NODE has provision to communicate with a remote Repeater unit using any of the networking interfaces.The Cause and Effect programming as well as customer specific Configurations can be uploaded to any OCTO panel in the network using the CHAMELEON CONNECTOR software tool. This is done by USB connection. Later the updated panel can broadcast the same configuration to all other Chameleon Network panels.Key Features1 to 4 loops panelUp to 250 devices per loop 125 address limitUp to 95 VULCAN 2 addressable ultra low current base sounders 32 address limitSupports connection to Repeaters via RS422 Fibre-Optic or TCPIPNetworked system up to 128 loopsChameleon Peer-to-Peer Advanced Networking Protocol with up to 32 NODE32 individually programmable sounder addressesSupport of Non-European languages Mandarin Arabic Hindu Urdu Farsi etc.Full Self-Addressable Devices supportBuilt in Fire Fault relays2 conventional alarm outputs individually programmableDetection loops monitored for integrity384 fully programmable multi loop zones512 fully programmable sounder groups512 IO groupsEvent log rolling 10000 entriesRemovable ChassisBlack version

GBP 1518.88
1