123 results (0,13511 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Haes ESA-1006 1 to 2 Loops Apollo Addressable Panel

Haes ESA-1007 1 to 4 Loops Apollo Addressable Panel

Haes ESA-1002 1 to 4 Loops Argus Addressable Panel

Haes ESA-1001 1 to 2 Loops Argus Addressable Panel

Haes 3.0amp 24vdc EN54 Battery Charger Power Supply Up To 7AH Batteries PSAS-30EN54

Haes 5.0amp 24vdc EN54 Battery Charger Power Supply Up To 38Ah Batteries PSAL-50EN54

Haes 3.0amp 24vdc EN54 Battery Charger Power Supply Up To 18Ah Batteries PSAM-30EN54

Haes 1.5amp 24vdc EN54 Battery Charger Power Supply Up To 7Ah Batteries PSAS-15EN54

Haes 5.0amp 24vdc EN54 Battery Charger Power Supply Up To 18Ah Batteries PSAM-50EN54

Haes Comms Card for Repeater amp Network Connections TPCA05

Haes 24 Zone Excel-32 Conventional Control Panel with Networking XL32-24

Haes 24 Zone Excel-32 Conventional Control Panel with Networking XL32-24

Haes 24 Zone Excel-32 Conventional Control Panel with Networking XL32-24Quality reliability ease of use and feature rich are attributes that are consistent across the entire range of Haes fire alarm control panels. The Haes Excel-32 encompasses all of these attributes to provide the fire alarm engineers panel of choice. For the fire alarm engineer the Excel-32 has been designed to minimise labour costs by providing ample room for tasks such as wiring and changing batteries. Activation is via key switch or access code which means you should always be able to work on the panel and the one man walk tests will help reduce the cost of maintaining the fire alarm system.Simplicity is one of the most important aspects when considering the end user of a fire alarm panel. The colour coded buttons and the 3 step silence functionality gives non-technical people the confidence to correctly manage their fire alarm system. All inputs and outputs are fully programmable and there are options to have delays to the outputs. The programming features of the Excel-32 also include 3 different modes to help reduce false alarms. Local fire authorities are demanding this type of functionality to reduce unwanted callouts from alarm receiving centresAs standard all Excel-32 panels provide four monitored sounder circuits Fire Fault VFCO relays Fire Fault switched negative outputs class change and an alert input. Excel-32 panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Key Features16 - 32 zones3 modes to manage false alarmsApproved to EN54-2 43 year warrantyFour monitored sounder circuitsClass change alert programmable inputsProgrammable relays outputsFire alarm routing outputOne man walk testKey-switch or code entry for activation of controlsFully functional LCD remote display units

GBP 1071.11
1

Haes 32 Zone Excel-32 Conventional Control Panel with Networking XL32-32

Haes 32 Zone Excel-32 Conventional Control Panel with Networking XL32-32

Haes 32 Zone Excel-32 Conventional Control Panel with Networking XL32-32Quality reliability ease of use and feature rich are attributes that are consistent across the entire range of Haes fire alarm control panels. The Haes Excel-32 encompasses all of these attributes to provide the fire alarm engineers panel of choice. For the fire alarm engineer the Excel-32 has been designed to minimise labour costs by providing ample room for tasks such as wiring and changing batteries. Activation is via key switch or access code which means you should always be able to work on the panel and the one man walk tests will help reduce the cost of maintaining the fire alarm system.Simplicity is one of the most important aspects when considering the end user of a fire alarm panel. The colour coded buttons and the 3 step silence functionality gives non-technical people the confidence to correctly manage their fire alarm system. All inputs and outputs are fully programmable and there are options to have delays to the outputs. The programming features of the Excel-32 also include 3 different modes to help reduce false alarms. Local fire authorities are demanding this type of functionality to reduce unwanted callouts from alarm receiving centresAs standard all Excel-32 panels provide four monitored sounder circuits Fire Fault VFCO relays Fire Fault switched negative outputs class change and an alert input. Excel-32 panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Key Features16 - 32 zones3 modes to manage false alarmsApproved to EN54-2 43 year warrantyFour monitored sounder circuitsClass change alert programmable inputsProgrammable relays outputsFire alarm routing outputOne man walk testKey-switch or code entry for activation of controlsFully functional LCD remote display units

GBP 1322.57
1

Haes 16 Zone Excel-32 Conventional Control Panel with Networking XL32-16

Haes 16 Zone Excel-32 Conventional Control Panel with Networking XL32-16

Haes 16 Zone Excel-32 Conventional Control Panel with Networking XL32-16Quality reliability ease of use and feature rich are attributes that are consistent across the entire range of Haes fire alarm control panels. The Haes Excel-32 encompasses all of these attributes to provide the fire alarm engineers panel of choice. For the fire alarm engineer the Excel-32 has been designed to minimise labour costs by providing ample room for tasks such as wiring and changing batteries. Activation is via key switch or access code which means you should always be able to work on the panel and the one man walk tests will help reduce the cost of maintaining the fire alarm system.Simplicity is one of the most important aspects when considering the end user of a fire alarm panel. The colour coded buttons and the 3 step silence functionality gives non-technical people the confidence to correctly manage their fire alarm system. All inputs and outputs are fully programmable and there are options to have delays to the outputs. The programming features of the Excel-32 also include 3 different modes to help reduce false alarms. Local fire authorities are demanding this type of functionality to reduce unwanted callouts from alarm receiving centresAs standard all Excel-32 panels provide four monitored sounder circuits Fire Fault VFCO relays Fire Fault switched negative outputs class change and an alert input. Excel-32 panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Key Features16 - 32 zones3 modes to manage false alarmsApproved to EN54-2 43 year warrantyFour monitored sounder circuitsClass change alert programmable inputsProgrammable relays outputsFire alarm routing outputOne man walk testKey-switch or code entry for activation of controlsFully functional LCD remote display units

GBP 819.72
1

Haes Eclipse 4 Zone Conventional Twin Wire Control Panel ECL-4

Haes Eclipse 4 Zone Conventional Twin Wire Control Panel ECL-4

Haes Eclipse 4 Zone Conventional Twin Wire Control Panel ECL-4Quality reliability ease of use and feature rich are attributes that are consistent across the entire range of Haes fire alarm control panels. As the entry level panel from Haes the Eclipse encompasses all of these attributes to provide a panel that meets a variety of needs. For the fire alarm engineer the Eclipse has been designed to minimise labour costs. There is ample room for wiring changing batteries and clear indication. Activation is via key switch or access code which means you should always be able to work on the panel and the one man walk tests will help reduce the cost of maintaining the fire alarm system.Simplicity was one of the most important aspects when considering the end user of a fire alarm panel. The colour coded buttons and the 3 step silence functionality gives non-technical people the confidence to correctly manage their fire alarm system. The Eclipse is the only entry level panel on the market that will reduce false alarms. The Eclipse can be programmed so that it requires a secondary confirmation before sending the panel into alarm. Fire and Rescue services are looking to this type of functionality to allow them to respond to Alarm Receiving Centres.Two or four fire zone circuits are provided plus two monitored sounder circuits. Fire Fault VFCO relays Fire Fault switched negative outputs class change and an alert input are also included. The fire zone outputs can be set as Twin Wire by DIL switch selection. In Twin Wire configuration special detector bases and call points must be used. Eclipse panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Key Features2 or 4 zoneFalse alarm management modeTwin Wire selection by DIL switchApproved to EN54-2 4Smart design easy to install commission serviceClass change inputs pulsing inputsFire fault relays2 monitored sounder circuitsOne man walk testKey-switch or code entry for activation of controlsNon latching zone for interfacingFault diagnostics mode

GBP 223.67
1

Haes 2 Zone Excel-EN Conventional Twin Wire Control Panel with Networking XLEN-2

Haes 2 Zone Excel-EN Conventional Twin Wire Control Panel with Networking XLEN-2

Haes 2 Zone Excel-EN Conventional Twin Wire Control Panel with Networking XLEN-2Quality reliability ease of use and feature rich are attributes that are consistent across the entire range of Haes fire alarm control panels. The Haes Excel-EN encompasses all of these attributes to provide the fire alarm engineers panel of choice. The Excel-EN combines the benefits of addressable panels with the simplicity of conventional panels for the fire alarm engineer the Excel-EN has been designed to minimise labour costs by providing ample room for tasks such as wiring and changing batteries.Activation is via key switch or access code which means you should always be able to work on the panel and the one man walk tests will help reduce the cost of maintaining the fire alarm system. Simplicity is one of the most important aspects when considering the end user of a fire alarm panel. The colour coded buttons and the 3 step silence functionality gives non-technical people the confidence to correctly manage their fire alarm system.All inputs and outputs are fully programmable and there are options to have delays to the outputs. The programming features of the Excel- EN also include 3 different modes to help reduce false alarms. Local fire authorities are demanding this type of functionality to reduce unwanted callouts from alarm receiving centres as standard all Excel-EN panels provide two monitored sounder circuits Fire Fault VFCO relays and Fire Fault switched negative outputs class change and an alert input. Excel-EN panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Key Features2 - 12 zones3 modes to manage false alarmsIndividually selectable Twin Wire zonesApproved to EN54-2 43 year warrantyClass change alert programmable inputsProgrammable relays outputsModular expansion zone cards including additional sounder circuitsOne man walk testKey-switch or code entry for activation of controlsFully functional repeater panelsTwo monitored sounder circuits fitted as standard.

GBP 294.74
1

Haes Eclipse 2 Zone Conventional Twin Wire Control Panel ECL-2

Haes Eclipse 2 Zone Conventional Twin Wire Control Panel ECL-2

Haes Eclipse 2 Zone Conventional Twin Wire Control Panel ECL-2Quality reliability ease of use and feature rich are attributes that are consistent across the entire range of Haes fire alarm control panels. As the entry level panel from Haes the Eclipse encompasses all of these attributes to provide a panel that meets a variety of needs. For the fire alarm engineer the Eclipse has been designed to minimise labour costs. There is ample room for wiring changing batteries and clear indication. Activation is via key switch or access code which means you should always be able to work on the panel and the one man walk tests will help reduce the cost of maintaining the fire alarm system.Simplicity was one of the most important aspects when considering the end user of a fire alarm panel. The colour coded buttons and the 3 step silence functionality gives non-technical people the confidence to correctly manage their fire alarm system. The Eclipse is the only entry level panel on the market that will reduce false alarms. The Eclipse can be programmed so that it requires a secondary confirmation before sending the panel into alarm. Fire and Rescue services are looking to this type of functionality to allow them to respond to Alarm Receiving Centres.Two or four fire zone circuits are provided plus two monitored sounder circuits. Fire Fault VFCO relays Fire Fault switched negative outputs class change and an alert input are also included. The fire zone outputs can be set as Twin Wire by DIL switch selection. In Twin Wire configuration special detector bases and call points must be used. Eclipse panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Key Features2 or 4 zoneFalse alarm management modeTwin Wire selection by DIL switchApproved to EN54-2 4Smart design easy to install commission serviceClass change inputs pulsing inputsFire fault relays2 monitored sounder circuitsOne man walk testKey-switch or code entry for activation of controlsNon latching zone for interfacingFault diagnostics mode

GBP 194.92
1

Haes 6 Zone Excel-EN Conventional Twin Wire Control Panel with Networking XLEN-6

Haes 6 Zone Excel-EN Conventional Twin Wire Control Panel with Networking XLEN-6

Haes 6 Zone Excel-EN Conventional Twin Wire Control Panel with Networking XLEN-6Quality reliability ease of use and feature rich are attributes that are consistent across the entire range of Haes fire alarm control panels. The Haes Excel-EN encompasses all of these attributes to provide the fire alarm engineers panel of choice. The Excel-EN combines the benefits of addressable panels with the simplicity of conventional panels for the fire alarm engineer the Excel-EN has been designed to minimise labour costs by providing ample room for tasks such as wiring and changing batteries.Activation is via key switch or access code which means you should always be able to work on the panel and the one man walk tests will help reduce the cost of maintaining the fire alarm system. Simplicity is one of the most important aspects when considering the end user of a fire alarm panel. The colour coded buttons and the 3 step silence functionality gives non-technical people the confidence to correctly manage their fire alarm system.All inputs and outputs are fully programmable and there are options to have delays to the outputs. The programming features of the Excel- EN also include 3 different modes to help reduce false alarms. Local fire authorities are demanding this type of functionality to reduce unwanted callouts from alarm receiving centres as standard all Excel-EN panels provide two monitored sounder circuits Fire Fault VFCO relays and Fire Fault switched negative outputs class change and an alert input. Excel-EN panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Key Features2 - 12 zones3 modes to manage false alarmsIndividually selectable Twin Wire zonesApproved to EN54-2 43 year warrantyClass change alert programmable inputsProgrammable relays outputsModular expansion zone cards including additional sounder circuitsOne man walk testKey-switch or code entry for activation of controlsFully functional repeater panelsTwo monitored sounder circuits fitted as standard.

GBP 370.74
1

Haes 4 Zone Excel-EN Conventional Twin Wire Control Panel with Networking XLEN-4

Haes 4 Zone Excel-EN Conventional Twin Wire Control Panel with Networking XLEN-4

Haes 4 Zone Excel-EN Conventional Twin Wire Control Panel with Networking XLEN-4Quality reliability ease of use and feature rich are attributes that are consistent across the entire range of Haes fire alarm control panels. The Haes Excel-EN encompasses all of these attributes to provide the fire alarm engineers panel of choice. The Excel-EN combines the benefits of addressable panels with the simplicity of conventional panels for the fire alarm engineer the Excel-EN has been designed to minimise labour costs by providing ample room for tasks such as wiring and changing batteries.Activation is via key switch or access code which means you should always be able to work on the panel and the one man walk tests will help reduce the cost of maintaining the fire alarm system. Simplicity is one of the most important aspects when considering the end user of a fire alarm panel. The colour coded buttons and the 3 step silence functionality gives non-technical people the confidence to correctly manage their fire alarm system.All inputs and outputs are fully programmable and there are options to have delays to the outputs. The programming features of the Excel- EN also include 3 different modes to help reduce false alarms. Local fire authorities are demanding this type of functionality to reduce unwanted callouts from alarm receiving centres as standard all Excel-EN panels provide two monitored sounder circuits Fire Fault VFCO relays and Fire Fault switched negative outputs class change and an alert input. Excel-EN panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Key Features2 - 12 zones3 modes to manage false alarmsIndividually selectable Twin Wire zonesApproved to EN54-2 43 year warrantyClass change alert programmable inputsProgrammable relays outputsModular expansion zone cards including additional sounder circuitsOne man walk testKey-switch or code entry for activation of controlsFully functional repeater panelsTwo monitored sounder circuits fitted as standard.

GBP 317.90
1

Haes 2-12 Zone Fully Functional or Passive Repeater Panel XLEN-R-12

Haes 2-12 Zone Fully Functional or Passive Repeater Panel XLEN-R-12

Haes 2-12 Zone Fully Functional or Passive Repeater Panel XLEN-R-12The Excel-EN repeater panels have the same easy to use controls and indications as the main control panel but mounted in a smaller cabinet. The repeaters are fully functional with Silence Resound and Reset controls as well as Disable and Test Mode functions. It is also possible to disable the controls for each or all repeater panels to make them passive indication only. Excel-EN panels can support up to 8 repeater panels.Repeater panels are designed to be wired in a fault tolerant fail safe loop configuration from comms A to B and back to the main panel again. This enables repeater panels to still work if there is a break in the cables. If replacing an older system where the existing cabling cannot be configured in a loop as above it is possible to re-programme the panel back to legacy radial circuit comms monitoring. This then allows any topology of comms cabling to be utilised.The main circuit board has 2 switch ve inputs which can be used to sound or pulse the alarms. These inputs can also be re-programmed for use as PSU fault inputs. The internal comms PCB has 6 switch ve programmable outputs.Key Features12 zonal fire fault indications3 year warranty as standardSimple colour coded buttons for controlsIntegral 1 amp switch mode PSUClass change alert inputsProgrammable outputsTest mode disablement functionsFully functional or passiveSpace for up to 3.2Ah batteriesKey-switch or code entry for activation of controls

GBP 370.74
1

Haes 12 Zone Excel-EN Conventional Twin Wire Control Panel with Standard amp High Spec Zone Card XLEN-12

Haes 12 Zone Excel-EN Conventional Twin Wire Control Panel with Standard amp High Spec Zone Card XLEN-12

Haes 12 Zone Excel-EN Conventional Twin Wire Control Panel with Standard High Spec Zone Card XLEN-12Quality reliability ease of use and feature rich are attributes that are consistent across the entire range of Haes fire alarm control panels. The Haes Excel-EN encompasses all of these attributes to provide the fire alarm engineers panel of choice. The Excel-EN combines the benefits of addressable panels with the simplicity of conventional panels for the fire alarm engineer the Excel-EN has been designed to minimise labour costs by providing ample room for tasks such as wiring and changing batteries. Activation is via key switch or access code which means you should always be able to work on the panel and the one man walk tests will help reduce the cost of maintaining the fire alarm system. Simplicity is one of the most important aspects when considering the end user of a fire alarm panel. The colour coded buttons and the 3 step silence functionality gives non-technical people the confidence to correctly manage their fire alarm system.All inputs and outputs are fully programmable and there are options to have delays to the outputs. The programming features of the Excel- EN also include 3 different modes to help reduce false alarms. Local fire authorities are demanding this type of functionality to reduce unwanted callouts from alarm receiving centres as standard all Excel-EN panels provide two monitored sounder circuits Fire Fault VFCO relays and Fire Fault switched negative outputs class change and an alert input. Excel-EN panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Key Features2 - 12 zones3 modes to manage false alarmsIndividually selectable Twin Wire zonesApproved to EN54-2 43 year warrantyClass change alert programmable inputsProgrammable relays outputsModular expansion zone cards including additional sounder circuitsOne man walk testKey-switch or code entry for activation of controlsFully functional repeater panelsTwo monitored sounder circuits fitted as standard.Please Note As well as 4x monitored conventional twin wire zones the high spec zone card also offers 2x switched -ve outputs 1x aux relay output 2x monitored sounder circuits.

GBP 514.54
1

Haes 8 Zone Excel-EN Conventional Twin Wire Control Panel with High Spec Zone Card XLEN-8

Haes 8 Zone Excel-EN Conventional Twin Wire Control Panel with High Spec Zone Card XLEN-8

Haes 8 Zone Excel-EN Conventional Twin Wire Control Panel with High Spec Zone Card XLEN-8Quality reliability ease of use and feature rich are attributes that are consistent across the entire range of Haes fire alarm control panels. The Haes Excel-EN encompasses all of these attributes to provide the fire alarm engineers panel of choice. The Excel-EN combines the benefits of addressable panels with the simplicity of conventional panels for the fire alarm engineer the Excel-EN has been designed to minimise labour costs by providing ample room for tasks such as wiring and changing batteries.Activation is via key switch or access code which means you should always be able to work on the panel and the one man walk tests will help reduce the cost of maintaining the fire alarm system. Simplicity is one of the most important aspects when considering the end user of a fire alarm panel. The colour coded buttons and the 3 step silence functionality gives non-technical people the confidence to correctly manage their fire alarm system.All inputs and outputs are fully programmable and there are options to have delays to the outputs. The programming features of the Excel- EN also include 3 different modes to help reduce false alarms. Local fire authorities are demanding this type of functionality to reduce unwanted callouts from alarm receiving centres as standard all Excel-EN panels provide two monitored sounder circuits Fire Fault VFCO relays and Fire Fault switched negative outputs class change and an alert input. Excel-EN panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Key Features2 - 12 zones3 modes to manage false alarmsIndividually selectable Twin Wire zonesApproved to EN54-2 43 year warrantyClass change alert programmable inputsProgrammable relays outputsModular expansion zone cards including additional sounder circuitsOne man walk testKey-switch or code entry for activation of controlsFully functional repeater panelsTwo monitored sounder circuits fitted as standard.Please Note As well as 4x monitored conventional twin wire zones the high spec zone card also offers 2x switched -ve outputs 1x aux relay output 2x monitored sounder circuits.

GBP 370.74
1

Haes AlarmSense Plus 8 Zone Control Panel ASP-8

Haes AlarmSense Plus 8 Zone Control Panel ASP-8

Haes AlarmSense Plus 8 Zone Control Panel ASP-8Quality reliability ease of use and feature rich are attributes that are consistent across the entire range of Haes fire alarm control panels. The Haes AlarmSense PLUS encompasses all of these attributes to provide the fire alarm engineers panel of choice. For the fire alarm engineer the AlarmSense PLUS has been designed to minimise labour costs by providing ample room for tasks such as wiring and changing batteries. Activation is via key switch or access code which means you should always be able to work on the panel and the one man walk tests will help reduce the cost of maintaining the fire alarm system.Simplicity is one of the most important aspects when considering the end user of a fire alarm panel. The colour coded buttons and the 3 step silence functionality gives non-technical people the confidence to correctly manage their fire alarm system. All inputs and outputs are fully programmable and there are options to have delays and coincidence attributes to the outputs.As standard all AlarmSense PLUS panels provide two additional conventional monitored sounder circuits Fire Fault VFCO relays Fire Fault switched negative outputs class change and an alert input. Haes AlarmSense PLUS panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Key Features2 - 12 AlarmSense zonesApproved to EN54-2 4False alarm reduction with non priority signallingLocal general alarm switchingClass change pulsing programmable inputsIdeal for HMOsProgrammable relays outputsModular expansion zone cardsOne man walk testsKey-switch or code entry for activation of controlsFully functional repeater panels

GBP 372.60
1

Haes AlarmSense Plus 4 Zone Control Panel ASP-4

Haes AlarmSense Plus 4 Zone Control Panel ASP-4

Haes AlarmSense Plus 4 Zone Control Panel ASP-4Quality reliability ease of use and feature rich are attributes that are consistent across the entire range of Haes fire alarm control panels. The Haes AlarmSense PLUS encompasses all of these attributes to provide the fire alarm engineers panel of choice. For the fire alarm engineer the AlarmSense PLUS has been designed to minimise labour costs by providing ample room for tasks such as wiring and changing batteries. Activation is via key switch or access code which means you should always be able to work on the panel and the one man walk tests will help reduce the cost of maintaining the fire alarm system.Simplicity is one of the most important aspects when considering the end user of a fire alarm panel. The colour coded buttons and the 3 step silence functionality gives non-technical people the confidence to correctly manage their fire alarm system. All inputs and outputs are fully programmable and there are options to have delays and coincidence attributes to the outputs.As standard all AlarmSense PLUS panels provide two additional conventional monitored sounder circuits Fire Fault VFCO relays Fire Fault switched negative outputs class change and an alert input. Haes AlarmSense PLUS panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Key Features2 - 12 AlarmSense zonesApproved to EN54-2 4False alarm reduction with non priority signallingLocal general alarm switchingClass change pulsing programmable inputsIdeal for HMOsProgrammable relays outputsModular expansion zone cardsOne man walk testsKey-switch or code entry for activation of controlsFully functional repeater panels

GBP 343.44
1

Haes AlarmSense Plus 12 Zone Control Panel ASP-12

Haes AlarmSense Plus 12 Zone Control Panel ASP-12

Haes AlarmSense Plus 12 Zone Control Panel ASP-12Quality reliability ease of use and feature rich are attributes that are consistent across the entire range of Haes fire alarm control panels. The Haes AlarmSense PLUS encompasses all of these attributes to provide the fire alarm engineers panel of choice. For the fire alarm engineer the AlarmSense PLUS has been designed to minimise labour costs by providing ample room for tasks such as wiring and changing batteries. Activation is via key switch or access code which means you should always be able to work on the panel and the one man walk tests will help reduce the cost of maintaining the fire alarm system.Simplicity is one of the most important aspects when considering the end user of a fire alarm panel. The colour coded buttons and the 3 step silence functionality gives non-technical people the confidence to correctly manage their fire alarm system. All inputs and outputs are fully programmable and there are options to have delays and coincidence attributes to the outputs.As standard all AlarmSense PLUS panels provide two additional conventional monitored sounder circuits Fire Fault VFCO relays Fire Fault switched negative outputs class change and an alert input. Haes AlarmSense PLUS panels are approved to European standards EN54-2 4 Fire Detection and Alarm Systems Control Indicating Equipment.Key Features2 - 12 AlarmSense zonesApproved to EN54-2 4False alarm reduction with non priority signallingLocal general alarm switchingClass change pulsing programmable inputsIdeal for HMOsProgrammable relays outputsModular expansion zone cardsOne man walk testsKey-switch or code entry for activation of controlsFully functional repeater panels

GBP 494.10
1

Haes LCD Fully Functional Remote Display Unit XL-RDU

Haes LCD Fully Functional Remote Display Unit XL-RDU

Haes LCD Fully Functional Remote Display Unit XL-RDUThe XL-RDU 32 way LCD remote display repeater panels have the same easy to use controls and indications as the main control panels with the addition of a 4 line x 40 character backlit LCD display. The remote display units are fully functional with Silence Resound and Reset controls as well as Disable and Test Mode functions. It is also possible to disable the controls for each or all repeater panels to make them passive indication only. Up to 8 repeater panels can be supported on a system.The display text is fully editable for system panel and zone names plus up to 40 characters for installationservice company details. Other local options include setting the real time clock editing the user access code and lowering or muting the internal buzzer. All programming can be done using the on board controls and user menu or via the PC config software supplied. The main circuit board has 2 switch ve outputs which provide fire and fault signals. Inputs are available for use as PSU fault inputs. An input for a remote key-switch is also provided.Controls are enabled via a 4 digit code entry. The user code can be changed in the programming settings. An eight button keypad is used to control the system and allow access to the function options. The remote display unit is housed in a robust sheet steel enclosure suitable for wall mounting. Cable entry is via 20mm knockouts located at the top and rear of the cabinet. A nominal 28v dc supply is required to power the remote display units which can be obtained from the control panel or remote power supply unit.Key Features4 x 40 character backlit LCD displaySimple colour coded buttons for controlsProgrammable display textRemote key switch inputFull system controlTest mode disablement functionsFully functional or passiveUp to 8 units supported on a systemPC programming software

GBP 499.37
1