99 results (0,13612 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Hyfire HFW-CEM-02 Wireless to Conventional Interface Module

Hyfire HF-ESP-CP4-1 1 to 4 Loops Argus Addressable Panel

Hyfire HF-ESP-CP2-1 1 to 2 Loops Argus Addressable Panel

Hyfire TAU-DD-01 Taurus Connect Dongle

Hyfire HFC-SBW-23-03 Conventional Sounder Beacon - White EN54-23

Hyfire HFC-SBR-23-03 Conventional Red Sounder Beacon EN54-23

Hyfire HFC-WSR-03 Conventional Red Wall Sounder

Hyfire HFI-OM-RM-01 Mini Mount Single Relay Output Module

Hyfire HFI-CZM-01 Conventional Zone Interface Module

Hyfire HFI-CZM-01 Conventional Zone Interface Module

Hyfire HFI-CZM-01 Conventional Zone Interface ModuleThe VMCZ conventional zone module allows the connection of conventional detectors to a Vega intelligent loop. The module has an onboard relay output driven by the fire alarm control panel. The VCMZ module is designed to provide different current limits.The HFI-CZM-01 conventional zone module is a device permitting to interface an analogue-intelligent addressable loop to a conventional detection zone. The analogue panel sees this device and all the conventional sub-system as a single addressed device on the loop. Conventional zone conditions as normal open and short circuit and alarm are detected by this module and notified to the analogue control panel by the module itself nevertheless this device is not capable of detecting the removal of a sensor from the conventional line. The conventional zone module can be powered in different ways either directly by the analogue detection loop or by an external power supply source. The conventional zone module is capable of monitoring its power supply whether from the analogue loop or external and measure the actual current that is flowing to the conventional zone line giving the analogue control panel full control over the conventional sub-system and its status.Key FeaturesCan be powered either externally or from the loopShort circuit isolator built inAuto addressing capabilityAddressable via HFI-DPT-05 programmer5 year product warrantyAdjustable reset time allowing for greater loop lengthEnd of line options to allow for multiple application from one device

GBP 87.01
1

Hyfire HFI-OM-SM-01 Mini Mount Single Supervised Output Module

Hyfire HFI-IM-SM-01 Mini Mount Single Supervised Input Module

Hyfire HFI-CP-03C Intelligent Resettable Call Point

Hyfire Red Weatherproof Call Point Housing with No Sounder

Hyfire HF-WCPH-C-01 Clear Weatherproof Call Point Housing with No Sounder

Hyfire HFI-IO-SM-01 Mini Mount Single Input Single Supervised Output

Hyfire HFI-IO-SM-01 Mini Mount Single Input Single Supervised Output

Hyfire HFI-IO-SM-01 Mini Mount Single Input Single Supervised OutputThe module is a single input and single supervised output mini module. The module contains built in loop isolator which provides short circuit protection for the detection loop.The Hyfire module range provides an ideal solution to the monitoring and control requirements of most fire detection and alarm systems ranging from small and simple to large and complex. By utilising the Hyfire fully digital communication protocol reliable and fast operation is achieved even when employing the impressive 240 device loop capacity. A choice of mechanical configurations provides easy integration of the units into a variety of field locations. The HFI-IO-SM-01 is contained in a compact housing which can be easily mounted inside third party equipment and provides the capability to remotely monitor a single circuit and control a single ancillary circuit using external power. Both input and output circuits are monitored for fault conditions. Bi-colour LEDs provide local indication of device status.Key FeaturesEmploys the highly reliable Hyfire digital protocol3rd party approval to EN54-17 and EN54-18Integrated short circuit isolators to protect and maintain operationLoop powered with very low current consumptionRobust proven design offering operation over a wide temperature rangeProvides both a fully monitored input and output circuitFast fit plug-in cable connectionsAlternate mechanical variants available to satisfy different applicationsSmaller mechanical package size enables the module to be installed inside other enclosuresBi-colour status LED5 year product warranty

GBP 61.14
1

Hyfire HF-WCPH-RS-01 Weatherproof Call Point Housing With Internal Sounder Red Back Box

Hyfire HF-WCPH-CS-01 Weatherproof Call Point Housing With Internal Sounder Clear Back Box

Hyfire HFI-IO-RM-01 Mini Mount Single Input Single Relay Output

Hyfire HFI-IO-RM-01 Mini Mount Single Input Single Relay Output

Hyfire HFI-IO-RM-01 Mini Mount Single Input Single Relay OutputSingle input and single relay output mini module. VMMIC120 contains built in loop isolator which provides short circuit protection for the detection loop.The Hyfire module range provides an ideal solution to the monitoring and control requirements of most fire detection and alarm systems ranging from small and simple to large and complex. By utilising the Hyfire fully digital communication protocol reliable and fast operation is achieved even when employing the impressive 240 device loop capacity. A choice of mechanical configurations provides easy integration of the units into a variety of field locations. The HFIIO- RM-01 is contained in a compact housing which can be easily mounted inside third party equipment and provides the capability to both remotely monitor a single circuit and control a single ancillary circuit using a set of volt-free changeover relay contacts. The input circuit is monitored for fault condition. Bi-colour LEDs provide local indication of device status.Key FeaturesEmploys the highly reliable Hyfire digital protocol3rd party approval to EN54-17 and EN54-18Integrated short circuit isolators to protect and maintain operationLoop powered with very low current consumptionRobust proven design offering operation over a wide temperature rangeCan both monitor an input circuit and switch dual volt-free changeover relay contactsFast fit plug-in cable connectionsSmaller mechanical package size enables the module to be installed inside other enclosuresBi-colour status LED5 year product warranty

GBP 61.14
1

Hyfire HFW-W2W-01 Wireless Translator Module Loop Powered

Hyfire HFI-SIM-01 Addressable Sounder Interface Module

Hyfire TAU-BS-01-BL Taurus Sounder Base Black

Hyfire TAU-BS-01 Hyfire Taurus Sounder Base