13 results (0,12710 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Kentec Sigma Si Extinguishant Hold Off Unit Green Button K91000M10

Kentec KB91000M10 Sigma Si Extinguishant Hold Off Unit Red Button BS7273

Kentec K407 Switched Mode Power Supply Charger - 2.5 Amp PSU

Kentec Switched Mode Power Supply Charger - 5.25 Amp PSU K406

Kentec K1844-40 Sigma A-CP 4 Zone Control Panel 115V Grey

Kentec K1844-40 Sigma A-CP 4 Zone Control Panel 115V Grey

Kentec K1844-40 Sigma A-CP 4 Zone Control Panel 115V GreyThe Sigma A-CP is a range of conventional fire control panels with an optionalbuilt-in communicator.With two four or eight initiating circuits all panels can be extensivelyconfigured via a simple front panel operated programming method.The low standby power requirements and cost effective small batteries allowthe panel to be mounted in a discrete enclosure which is available in red orgrey.A simple programming method using just 3 front panel buttons allows anextensive list of configuration options to be set and reviewed.Single board construction enables easy removal of all electronic parts byremoving just two screws and ample provision of cable entry knockoutssimplify installation.4 Amp notification appliance power and built-in selectable sync protocolsprovide ample power and control for a wide range of standard notificationappliances.The built-in RS485 communications bus provides the facility to connect 4wire annunciators or ancillary relay boards to provide further indication andcontrol options throughout a premises.The optional DACT allows dual line reporting to central stations and providesa 500-event history buffer.Key Features4 Zone CircuitsInitiating circuits individually configurable as Fire Water Flow or SupervisoryTwo 2A notification appliance circuitsSelectable NAC sync protocols6.5A power supplyAlarm verification selectable by zoneResettable aux power output rated at 0.3AAux power configurable to power off on Fire conditionFire trouble and supervisory relaysSingle person walk test functionOptional DACTAdvanced configuration options72 hour standby with 7Ah batteriesCompact enclosureUL864 listed

GBP 431.34
1

Kentec K1844-11 Sigma A-CP 4 Zone Control Panel 240V Red

Kentec K1844-11 Sigma A-CP 4 Zone Control Panel 240V Red

Kentec K1844-11 Sigma A-CP 4 Zone Control Panel 240V RedThe Sigma A-CP is a range of conventional fire control panelswith an optional built-in communicator. With two four or eight initiatingcircuits all panels can be extensively configured via a simple front paneloperated programming method. The low standby power requirements and costeffective small batteries allow the panel to be mounted in a discrete enclosurewhich is available in red or grey. A simple programming method using just 3front panel buttons allows an extensive list of configuration options to be setand reviewed. Single board construction enables easy removal of all electronicparts by removing just two screws and ample provision of cable entry knockoutssimplify installation. 4 Amp notification appliance power and built-inselectable sync protocols provide ample power and control for a wide range ofstandard notification appliances. The built-in RS485 communications busprovides the facility to connect 4 wire annunciators or ancillary relay boardsto provide further indication and control options throughout a premises. Theoptional DACT allows dual line reporting to central stations and provides a500-event history buffer.Key Features4 Zone CircuitsInitiating circuits individually configurable as Fire Water Flow or SupervisoryTwo 2A notification appliance circuitsSelectable NAC sync protocols6.5A power supplyAlarm verification selectable by zoneResettable aux power output rated at 0.3AAux power configurable to power off on Fire conditionFire trouble and supervisory relaysSingle person walk test functionOptional DACTAdvanced configuration options72 hour standby with 7Ah batteriesCompact enclosureUL864 listed

GBP 431.34
1

Kentec K1848-11 Sigma A-CP 8 Zone Control Panel 240V Red

Kentec K1848-11 Sigma A-CP 8 Zone Control Panel 240V Red

Kentec K1848-11 Sigma A-CP 8 Zone Control Panel 240V RedThe Sigma A-CP is a range of conventional fire control panelswith an optional built-in communicator. With two four or eight initiatingcircuits all panels can be extensively configured via a simple front paneloperated programming method. The low standby power requirements and costeffective small batteries allow the panel to be mounted in a discrete enclosurewhich is available in red or grey. A simple programming method using just 3front panel buttons allows an extensive list of configuration options to be setand reviewed. Single board construction enables easy removal of all electronicparts by removing just two screws and ample provision of cable entry knockoutssimplify installation. 4 Amp notification appliance power and built-inselectable sync protocols provide ample power and control for a wide range ofstandard notification appliances. The built-in RS485 communications busprovides the facility to connect 4 wire annunciators or ancillary relay boardsto provide further indication and control options throughout a premises. Theoptional DACT allows dual line reporting to central stations and provides a500-event history buffer.Key Features8 Zone CircuitsInitiating circuits individually configurable as Fire Water Flow or SupervisoryTwo 2A notification appliance circuitsSelectable NAC sync protocols6.5A power supplyAlarm verification selectable by zoneResettable aux power output rated at 0.3AAux power configurable to power off on Fire conditionFire trouble and supervisory relaysSingle person walk test functionOptional DACTAdvanced configuration options72 hour standby with 7Ah batteriesCompact enclosureUL864 listed

GBP 466.76
1

Kentec K1844-10 Sigma A-CP 4 Zone Control Panel 115V Red

Kentec K1844-10 Sigma A-CP 4 Zone Control Panel 115V Red

Kentec K1844-10 Sigma A-CP 4 Zone Control Panel 115V RedThe Sigma A-CP is a range of conventional fire control panelswith an optional built-in communicator. With two four or eight initiatingcircuits all panels can be extensively configured via a simple front paneloperated programming method. The low standby power requirements and costeffective small batteries allow the panel to be mounted in a discrete enclosurewhich is available in red or grey. A simple programming method using just 3front panel buttons allows an extensive list of configuration options to be setand reviewed. Single board construction enables easy removal of all electronicparts by removing just two screws and ample provision of cable entry knockoutssimplify installation. 4 Amp notification appliance power and built-inselectable sync protocols provide ample power and control for a wide range ofstandard notification appliances. The built-in RS485 communications busprovides the facility to connect 4 wire annunciators or ancillary relay boardsto provide further indication and control options throughout a premises. Theoptional DACT allows dual line reporting to central stations and provides a500-event history buffer.Key Features4 Zone CircuitsInitiating circuits individually configurable as Fire Water Flow or SupervisoryTwo 2A notification appliance circuitsSelectable NAC sync protocols6.5A power supplyAlarm verification selectable by zoneResettable aux power output rated at 0.3AAux power configurable to power off on Fire conditionFire trouble and supervisory relaysSingle person walk test functionOptional DACTAdvanced configuration options72 hour standby with 7Ah batteriesCompact enclosureUL864 listed

GBP 431.34
1

Kentec K1848-41 Sigma A-CP 8 Zone Control Panel 240V Grey

Kentec K1848-41 Sigma A-CP 8 Zone Control Panel 240V Grey

Kentec K1848-41 Sigma A-CP 8 Zone Control Panel 240V GreyThe Sigma A-CP is a range of conventional fire control panelswith an optional built-in communicator. With two four or eight initiatingcircuits all panels can be extensively configured via a simple front paneloperated programming method. The low standby power requirements and costeffective small batteries allow the panel to be mounted in a discrete enclosurewhich is available in red or grey. A simple programming method using just 3front panel buttons allows an extensive list of configuration options to be setand reviewed. Single board construction enables easy removal of all electronicparts by removing just two screws and ample provision of cable entry knockoutssimplify installation. 4 Amp notification appliance power and built-inselectable sync protocols provide ample power and control for a wide range ofstandard notification appliances. The built-in RS485 communications busprovides the facility to connect 4 wire annunciators or ancillary relay boardsto provide further indication and control options throughout a premises. Theoptional DACT allows dual line reporting to central stations and provides a500-event history buffer.Key Features8 Zone CircuitsInitiating circuits individually configurable as Fire Water Flow or SupervisoryTwo 2A notification appliance circuitsSelectable NAC sync protocols6.5A power supplyAlarm verification selectable by zoneResettable aux power output rated at 0.3AAux power configurable to power off on Fire conditionFire trouble and supervisory relaysSingle person walk test functionOptional DACTAdvanced configuration options72 hour standby with 7Ah batteriesCompact enclosureUL864 listed

GBP 466.76
1

Kentec K1844-41 Sigma A-CP 4 Zone Control Panel 240V Grey

Kentec K1844-41 Sigma A-CP 4 Zone Control Panel 240V Grey

Kentec K1844-41 Sigma A-CP 4 Zone Control Panel 240V GreyThe Sigma A-CP is a range of conventional fire control panelswith an optional built-in communicator. With two four or eight initiatingcircuits all panels can be extensively configured via a simple front paneloperated programming method. The low standby power requirements and costeffective small batteries allow the panel to be mounted in a discrete enclosurewhich is available in red or grey. A simple programming method using just 3front panel buttons allows an extensive list of configuration options to be setand reviewed. Single board construction enables easy removal of all electronicparts by removing just two screws and ample provision of cable entry knockoutssimplify installation. 4 Amp notification appliance power and built-inselectable sync protocols provide ample power and control for a wide range ofstandard notification appliances. The built-in RS485 communications busprovides the facility to connect 4 wire annunciators or ancillary relay boardsto provide further indication and control options throughout a premises. Theoptional DACT allows dual line reporting to central stations and provides a500-event history buffer.Key Features4 Zone CircuitsInitiating circuits individually configurable as Fire Water Flow or SupervisoryTwo 2A notification appliance circuitsSelectable NAC sync protocols6.5A power supplyAlarm verification selectable by zoneResettable aux power output rated at 0.3AAux power configurable to power off on Fire conditionFire trouble and supervisory relaysSingle person walk test functionOptional DACTAdvanced configuration options72 hour standby with 7Ah batteriesCompact enclosureUL864 listed

GBP 431.34
1

Kentec K1848-10 Sigma A-CP 8 Zone Control Panel 115V Red

Kentec K1848-10 Sigma A-CP 8 Zone Control Panel 115V Red

Kentec K1848-10 Sigma A-CP 8 Zone Control Panel 115V RedThe Sigma A-CP is a range of conventional fire control panelswith an optional built-in communicator. With two four or eight initiatingcircuits all panels can be extensively configured via a simple front paneloperated programming method. The low standby power requirements and costeffective small batteries allow the panel to be mounted in a discrete enclosurewhich is available in red or grey. A simple programming method using just 3front panel buttons allows an extensive list of configuration options to be setand reviewed. Single board construction enables easy removal of all electronicparts by removing just two screws and ample provision of cable entry knockoutssimplify installation. 4 Amp notification appliance power and built-inselectable sync protocols provide ample power and control for a wide range ofstandard notification appliances. The built-in RS485 communications busprovides the facility to connect 4 wire annunciators or ancillary relay boardsto provide further indication and control options throughout a premises. Theoptional DACT allows dual line reporting to central stations and provides a500-event history buffer.Key Features8 Zone CircuitsInitiating circuits individually configurable as Fire Water Flow or SupervisoryTwo 2A notification appliance circuitsSelectable NAC sync protocols6.5A power supplyAlarm verification selectable by zoneResettable aux power output rated at 0.3AAux power configurable to power off on Fire conditionFire trouble and supervisory relaysSingle person walk test functionOptional DACTAdvanced configuration options72 hour standby with 7Ah batteriesCompact enclosureUL864 listed

GBP 466.76
1

Kentec K1848-40 Sigma A-CP 8 Zone Control Panel 115V Grey

Kentec K1848-40 Sigma A-CP 8 Zone Control Panel 115V Grey

Kentec K1848-40 Sigma A-CP 8 Zone Control Panel 115V GreyThe Sigma A-CP is a range of conventional fire control panelswith an optional built-in communicator. With two four or eight initiatingcircuits all panels can be extensively configured via a simple front paneloperated programming method. The low standby power requirements and costeffective small batteries allow the panel to be mounted in a discrete enclosurewhich is available in red or grey. A simple programming method using just 3front panel buttons allows an extensive list of configuration options to be setand reviewed. Single board construction enables easy removal of all electronicparts by removing just two screws and ample provision of cable entry knockoutssimplify installation. 4 Amp notification appliance power and built-inselectable sync protocols provide ample power and control for a wide range ofstandard notification appliances. The built-in RS485 communications busprovides the facility to connect 4 wire annunciators or ancillary relay boardsto provide further indication and control options throughout a premises. Theoptional DACT allows dual line reporting to central stations and provides a500-event history buffer.Key Features8 Zone CircuitsInitiating circuits individually configurable as Fire Water Flow or SupervisoryTwo 2A notification appliance circuitsSelectable NAC sync protocols6.5A power supplyAlarm verification selectable by zoneResettable aux power output rated at 0.3AAux power configurable to power off on Fire conditionFire trouble and supervisory relaysSingle person walk test functionOptional DACTAdvanced configuration options72 hour standby with 7Ah batteriesCompact enclosureUL864 listed

GBP 466.76
1

Kentec Sigma A-CP Conventional Control Panel ULFM Approved K1842-11

Kentec Sigma A-CP Conventional Control Panel ULFM Approved K1842-11

Kentec Sigma A-CP Conventional Control Panel ULFM ApprovedThe Sigma A-CP range of conventional fire control panels with optional built in communicator are available with 2 4 or 8 initiating circuits which may be extensively configured via a simple front panel operated programming method. The low standby power requirements and cost effective small batteries allow the panel to be mounted in a small discrete enclosure which is available in standard red or optionally in an attractive grey colour.A simple programming method using just 3 front panel buttons allows an extensive list of configuration options to be set and reviewed. Single board construction which allows easy removal of all electronic parts by removing just 2 screws and ample provision of cable entry knockouts simplify installation. 4 Amp notification appliances power and built in selectable sync protocols provide ample power and control for a wide range of standard notification appliances.The built in RS485 communications bus provides the facility to connect 4 wire annunciators or ancillary relay boards to provide further indication and control options throughout a premises. The optional DACT allows dual line reporting to central stations and provides a 500 event history buffer.Key FeaturesUL864 approvedTwo four or eight initiating circuitsInitiating circuits individually configurable asFire Water flow or SupervisoryTwo 2A notification appliance circuitsSelectable NAC sync protocolsTwo 2.0A notification appliance circuits6.5A power supplyAlarm verification selectable by zoneResettable Aux power output rated at 0.3AAux power configurable to power off onFire conditionFire Trouble and Supervisory relaysSingle person walk test functionOptional DACTMany advanced configuration options72 hour standby with 7Ah batteriesCompact enclosureFire Drill capability

GBP 377.57
1