23 results (0,15406 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Kidde 1-23911-K075 FireBeta XT Status Indicator with Key Switch amp Manual Release

Kidde 1-23911-K073 FireBeta XT Status Indicator With Key Switch

Kidde 1-23911-K073 FireBeta XT Status Indicator With Key Switch

Kidde 1-23911-K073 FireBeta XT Status Indicator With Key SwitchThe Kidde 1-23911-K073 FireBeta XT Status Indicator with Key Switch is an accessory to the EN approved FireBeta XTXT extinguishing control panels. They provide detailed status information via 6 high bright LEDs on the status of the extinguishant release control. A LED display shows a countdown of the time remaining in seconds until the extinguishant is released. Status units are normally mounted at various access points into the risk area for notification for safety purposes.For systems where local control of the AutomaticManual mode are required the Kidde 1-23911-K073 FireBeta XT Status Indicator with Key Switch units are supplied with this control fitted. It allows the extinguishing system operation to be locally changed from automatic to manual mode on the status unit.Output FunctionsThe following area statuses are signalledManual onlyAutoManualHold activatedDisabledImminentReleasedInput FunctionsTwo supervised inputs are provided on every status unit.AutoManual control An input is provided on the status unit to monitor a door interlock system. This provides additional safety for unmanned areas. Door monitoring interlocks may be fitted to all access points into the risk area which when connected to the status unit automatically changes the operating mode for the extinguishing area between automatic and manual status as the door is locked or unlocked.Extinguishing Hold control By connecting a dedicated hold button to this input activating this button allows the extinguishant release countdown to be stopped while the hold button is active.InstallationEvery status unit is provided in a rugged steel enclosure for surface mounting. Up to 7 status units may be connected to the FireBeta XTXT control panel via a fully monitored RS485 communication link of up to 1200 m.Key FeaturesManual only Automatic Manual mode select key switchFour wire connection data and powerRobust high quality surface mount enclosureUp to 7 units per panelRemote automanual door interlock and extinguishing hold supervised inputsEasy access to terminals for easy installationInternal fault diagnosis indicatorsInternal buzzer

GBP 180.37
1

Kidde Airsense EST-M01 Microphone 1 Button

Kidde Airsense EST-XAUDIO-48-RS Function Card 4 IN 8 OUT Audio RS485

Kidde 1-23911-K090 FireBeta XT 4 Zone 1 Area Control Panel

Kidde 1-23911-K090 FireBeta XT 4 Zone 1 Area Control Panel

Kidde 1-23911-K090 FireBeta XT 4 Zone 1 Area Control PanelKidde 1-23911-K090 FireBeta XT extinguishing control panels are designed and manufactured to the highest standards in a quality controlled environment. With its EN12094-1 approvals it offers outstanding value and performance for small to medium sized fixed firefighting installations. The Kidde 1-23911-K090 FireBeta XT is supplied in an enclosure that matches the design and color of the status unit range.The 4 detection zone circuits allow extinguishing agent release to be configured to activate from any combination of detection zones. This allows among others any 2 zones from the combination of 3 to activate release making it ideal for applications protecting ceiling room and floor voids.The extensive configuration options of the FireBeta XT allow the functionality of the system to be extensively modified to suit the application while still complying with EN12094-1 EN54-2 and EN54-4. A large LED display on the panel fascia enables easy configuration and control. It additionally displays the time remaining until extinguishing agent release for added user safety.The control panel status can be displayed on up to 7 remote status indicators. This allows the agent release status to be displayed at for e.g. multiple entrances to a protected area adding additional user safety. The communication between the panel and its status indicators is fully monitored.The internal electronics are mounted on a single easily removable steel plate making the FireBeta XT robust and easy to install.Key FeaturesWalk test modeTwo first stage sounder outputsOne second stage sounder outputFirst stage relay contactSecond stage relay contactAuxiliary 24V DC outputMonitored manual release inputMonitored extinguishant outputMonitored Released pressure switch inputMode select keyswitch on front panel optionalManual release on front panel optional

GBP 1983.86
1

NC-DBO Conventional Beam Detector - Reflective

NC-DBO Conventional Beam Detector - Reflective

NC-DBO Conventional Beam Detector - ReflectiveThe NC-DBO is a reflective infrared beam smoke detector for use in conventional fire detection systems. Being microprocessor based the detector offers extensive algorithms for analysis and decision making. Taking ambient operating conditions into consideration system adjustments such as drift compensation and alarm and fault analysis are automatic. The sensitivity of the detector is adjustable to suit various application conditions.InstallationThe number of reflectors in a system varies depending on the required operating distance detection range of the detector. Optical reflectors from 1 to 4 provide an effective range of the detector between 5 and 100m. Four reflectors are supplied with the beam. The detection range of the beam can be selected from 4 levels with the hand held programmer NC-D-PT. For very short range detection 10 m a non reflective mask NRM9105 is recommended to attenuate the reflector.Key FeaturesWide operating voltage rangeLarge protection areaCombination of transmitter receiver in one housingallows for easy installation and optical alignmentIntelligent microprocessor based decision making on fire andfault statusesEasy alignment and commissioning with onboard laser andsignal level indicationSelf-diagnostics for monitoring reporting internalfailuresAutomatic drift compensation compensates for changingenvironmental conditions dust and dirt accumulation building movement andchanging internal component specifications due to ageingOnboard NO fire and NC fault dry contact outputs for easysupervisionFour selectable sensitivity levels for wideapplication coverage

GBP 426.44
1

NC-DPO-W Conventional Point Detector - Optical White

Kidde Airsense EST-M04 Microphone 4 Buttons

Kidde Airsense EST-xCtrLine-2 Function Card 8 IN Audio

Kidde Airsense EST-XCTRLINE-4 Function Card 4 IN 8 OUT Audio RS485

Kidde Airsense ADELCU-EOL Spare End-of-Line Unit

Kidde 1-23911-K116 FireBeta A-XT Extinguishing Control Panel

Kidde 1-23911-K116 FireBeta A-XT Extinguishing Control Panel

Kidde 1-23911-K116 FireBeta A-XT Extinguishing Control PanelThe Kidde 1-23911-K116 FireBeta A-XT Extinguishing Control Panel is a ULFM listed extinguishing control panel designed and manufactured to the highest standards in a quality controlled environment. With UL and FM approvals it offers outstanding value and performance for small to medium sized fixed firefighting installations. FireBeta A-XT is supplied in a red enclosure.The 3 initiation circuits allow extinguishant release to be configured to activate from any combination of detection zone inputs. This allows among others any 2 zones from the combination of 3 to activate release making it ideal for applications protecting ceiling room and floor voids.The extensive configuration options of the FireBeta A-XT allow the functionality of the system to be extensively modified. A large LED display on the panel fascia enables easy configuration and control. It additionally displays the time remaining until extinguishing agent release for added user safety.Key FeaturesUL864 and FM listedThree initiation circuits as standardAny single zone or any combinations of zones can be configured to releaseConfigurable first stage NAC delaysConfigurable detection delaysZero time delay upon manual release optionCompatible with I.S. barriersNon-latching zone input option to receive signals from other systems such as aspirating equipmentConfigurable releasing delays up to 60 seconds in 5 second stepsConfigurable releasing duration up to 5 minutes in 5 second stepsCountdown timer shows time remaining to releaseSupports up to seven four wire status indicatorsBuilt in extract fan control

GBP 536.48
1

Kidde AD68N-0500 Alarmline 68 Degree Alarm Temperature Digital Sensor Cable Nylon

Kidde Alarmline AD68SS-0500 68 Degree Alarm Temperature Digital Sensor Cable PVC and Stainless Steel

Kidde AD68P-0500 Alarmline 68 Degree Alarm Temperature Digital Sensor Cable PVC and Poly

Kidde AD68N-1000 Alarmline 68 Degree Alarm Temperature Digital Sensor Cable Nylon

Kidde Airsense APIC Card Hochiki Protocol 9-30438

Kidde 1-23911-K087 FireBeta XT Extinguishing Control Panel 4 Zone 1 Area

Kidde Alarmline AD68SS-0100 68 Degree Alarm Temperature Digital Sensor Cable PVC and Stainless Steel

Kidde AD68N-0100 Alarmline 68 Degree Alarm Temperature Digital Sensor Cable Nylon

Kidde AD68P-0100 Alarmline 68 Degree Alarm Temperature Digital Sensor Cable PVC and Poly

Kidde Airsense EST-DMS Zone Microphone

GBP 866.45
1

Kidde Airsense EST-DFMS Fireman Microphone

Kidde Airsense EST-DFMS Fireman Microphone

Kidde Airsense EST-DFMS Fireman MicrophoneA EST ENT VES fireman microphone is a monitored external device working with Control Units in a redundant communication ring. It can thereby perform a superior function of a system control unit too.A fireman microphone can be used to activate alarm messages as well as general public announcements to choose individual zones and to broadcast live voice messages. It is equipped with programmable function keys which can be used to assign functions as required. Up to 5 EST-EKB-20M keyboard extensions with additional function keys can be attached to a fireman microphone.A CPU switch enables immediate and direct broadcasting of announcements to all zones without any involvement of the control system even during a failure of the central processor. The microphone is able to automatically detect a key failure and an audio path from the microphone capsule inclusive to the Control Unit. A fireman microphone is also equipped with an intercom function and is able to communicate with other microphones in the system.Key FeaturesMonitored microphone and connection of the microphone module to the systemA dedicated evacuation key 3 fully-programmable keys with a possibility of connecting up to five 20-key extensionsBuilt-in 2 contact inputs and 2 relay outputsPOE or external feeder-based power supplyBlack-box function recording all announcements played during an alarmBuilt-in SFP modules and CAT5e for simplicity of implementation of the loop topologyRS485 for communication with external systemsIntercom function between all fireman and zone microphones

GBP 1256.28
1