16 results (0,26044 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Kidde Airsense ADLCU-2 AlarmLine II - Dual Zone Digital Location Control Unit

Kidde AD68N-1000 Alarmline 68 Degree Alarm Temperature Digital Sensor Cable Nylon

Kidde AD68N-0500 Alarmline 68 Degree Alarm Temperature Digital Sensor Cable Nylon

Kidde AD68N-0100 Alarmline 68 Degree Alarm Temperature Digital Sensor Cable Nylon

Kidde Airsense ADELCU-2 Alarmline II Digital LHD EN54-28 Dual Zone Location Control Unit

Kidde Airsense ADELCU-2 Alarmline II Digital LHD EN54-28 Dual Zone Location Control Unit

Kidde Airsense ADELCU-2 Alarmline II Digital LHD EN54-28 Dual Zone Location Control UnitThe ADELCU-2 digital location control unit is a dual zone module for monitoring up to two zones of AlarmLine II Digital EN Linear Heat Detection Cable. If an overheat or fire situation triggers either zone of the digital cable the unit automatically calculates and displays the distance along the cable in feet and metres to the alarm point.The two zones can operate independently of each other or in interlock mode. A separate alarm and normally conducting fault output are provided for each zone. The unit is intended to be installed between the AlarmLine II digital EN linear heat detection cable and a conventional or addressable fire alarm control panel. It has power fault and alarm indicators as well as free outputs for fault and alarm corresponding to each zone. It may also be connected to a industrial process control system using the two wire RS-485 Modbus RTU output.Modbus communicationThe unit includes a two wire RS-485 Modbus output which can be enabled to output the status of each zone of the digital location control unit via Modbus RTUASCII protocol. In case of an alarm the location in distance along the cable is also communicated via Modbus.Interconnecting cableThe unit supports the use of a interconnecting cable leader cable in between the control unit and the linear heat detection cable. The interconnecting cable is used in applications where the control unit is not located in the detection zone. The interconnecting cable is then used to connect the control unit in one location with the linear heat detection cable in the protected area. The interconnecting cable is available in 100 m lengths under the product code AAI-0100.Key FeaturesDual Zone - used as Independent or InterlockDesigned for AlarmLine II Digital EN linear heat cableEasy to installIP Rating IP65RoHS compliant CE EN54-282016 certifiedModbus support1km of cable supported per zoneWide supply voltageLow current consumption

GBP 1253.77
1

Kidde AD68P-0500 Alarmline 68 Degree Alarm Temperature Digital Sensor Cable PVC and Poly

Kidde AD68P-0100 Alarmline 68 Degree Alarm Temperature Digital Sensor Cable PVC and Poly

Kidde Alarmline AD68SS-0500 68 Degree Alarm Temperature Digital Sensor Cable PVC and Stainless Steel

Kidde Alarmline AD68SS-0100 68 Degree Alarm Temperature Digital Sensor Cable PVC and Stainless Steel

Kidde Airsense ADE78-0100 Digital Cable 78 Degree C - Low Smoke Zero Halogen - 100m

Kidde Airsense ADE78-0100 Digital Cable 78 Degree C - Low Smoke Zero Halogen - 100m

Kidde Airsense ADE78-0100 Digital Cable 78 Degree C - Low Smoke Zero Halogen - 100mThe Kidde ADE78-0100 is a 100m roll of Digital Linear Heat Detection LHD cable with a 78C fixed temperature activation rating. The ADE range of digital sensor cables provides a very simple fixed temperature heat detection system which can be used in many applications where other forms of detection are not suitable.Alarm locationThe control unit can identify along the length of the sensor cable where an alarm condition has occurred. The alarm location is then indicated on the display of the controller. Both zones are displayed at the same time.OperationThe ADE range of digital LHD cables contains a pair of twisted low resistance tri-metallic conductors sheathed with advanced temperature sensitive polymers. The cable operates by softening the insulation of the conductors the tension of the twisted conductors then causes the two cores to fuse together. The sensor cable is used in combination with the controller and end-of-line EOL unit and can connected to any fire monitoring equipment through any monitored input i.e. conventional detection zone or addressable interface unit to signal an alarm condition.Cable fixings for all applicationsA range of edge A P and T clips allow the cable to be properly installed. The clips provide heat insulation as well as holding the cable at the correct distance from cable trays steel works ceilings and walls.Key FeaturesEN54-282016 approvedLow-Smoke Zero HalogenUp to 1000 mDetection along total cable lengthFlame retardant

GBP 528.19
1

Kidde Airsense ADE88-0500 Digital Cable 88 Degree C - Low Smoke Zero Halogen - 500m - LSZH Coated Out

Kidde Airsense ADE88-0500 Digital Cable 88 Degree C - Low Smoke Zero Halogen - 500m - LSZH Coated Out

Kidde Airsense ADE88-0100 Digital Cable 88 Degree C - Low Smoke Zero Halogen - 500m - LSZH Coated OutThe Kidde ADE88-0500 is a 500m roll of Digital Linear Heat Detection LHD cable with a 88C fixed temperature activation rating. The ADE range of digital sensor cables provides a very simple fixed temperature heat detection system which can be used in many applications where other forms of detection are not suitable.Alarm locationThe control unit can identify along the length of the sensor cable where an alarm condition has occurred. The alarm location is then indicated on the display of the controller. Both zone are displayed at the same time.OperationThe ADE range of digital LHD cables contains a pair of twisted low resistance tri-metallic conductors sheathed with advanced temperature sensitive polymers. The cable operates by softening the insulation of the conductors the tension of the twisted conductors then causes the two cores to fuse together. The sensor cable is used in combination with the controller and end-of-line EOL unit and can connected to any fire monitoring equipment through any monitored input i.e. conventional detection zone or addressable interface unit to signal an alarm condition.Cable fixings for all applicationsA range of edge A P and T clips allow the cable to be properly installed. The clips provide heat insulation as well as holding the cable at the correct distance from cable trays steel works ceilings and walls.Key FeaturesEN54-282016 approvedLow-Smoke Zero HalogenDetection along total cable lengthFlame retardant

GBP 2640.92
1

Kidde Airsense ADE88-0100 Digital Cable 88 Degree C - Low Smoke Zero Halogen - 100m - LSZH Coated Out

Kidde Airsense ADE88-0100 Digital Cable 88 Degree C - Low Smoke Zero Halogen - 100m - LSZH Coated Out

Kidde Airsense ADE88-0100 Digital Cable 88 Degree C - Low Smoke Zero Halogen - 100m - LSZH Coated OutThe Kidde ADE88-0100 is a 100m roll of Digital Linear Heat Detection LHD cable with a 88C fixed temperature activation rating. The ADE range of digital sensor cables provides a very simple fixed temperature heat detection system which can be used in many applications where other forms of detection are not suitable.Alarm locationThe control unit can identify along the length of the sensor cable where an alarm condition has occurred. The alarm location is then indicated on the display of the controller. Both zone are displayed at the same time.OperationThe ADE range of digital LHD cables contains a pair of twisted low resistance tri-metallic conductors sheathed with advanced temperature sensitive polymers. The cable operates by softening the insulation of the conductors the tension of the twisted conductors then causes the two cores to fuse together. The sensor cable is used in combination with the controller and end-of-line EOL unit and can connected to any fire monitoring equipment through any monitored input i.e. conventional detection zone or addressable interface unit to signal an alarm condition.Cable fixings for all applicationsA range of edge A P and T clips allow the cable to be properly installed. The clips provide heat insulation as well as holding the cable at the correct distance from cable trays steel works ceilings and walls.Key FeaturesEN54-282016 approvedLow-Smoke Zero HalogenDetection along total cable lengthFlame retardant

GBP 528.19
1

Kidde Airsense ADE78-0500 Digital Cable 78 Degree C - Low Smoke Zero Halogen - 500m - LSZH Coated Out

Kidde Airsense ADE78-0500 Digital Cable 78 Degree C - Low Smoke Zero Halogen - 500m - LSZH Coated Out

Kidde Airsense ADE78-0500 Digital Cable 78 Degree C - Low Smoke Zero Halogen - 500m - LSZH Coated OutThe ADE78-0500 is a 500m roll of Digital Linear Heat Detection LHD cable with a 78C fixed temperature activation rating. The ADE range of digital sensor cables provides a very simple fixed temperature heat detection system which can be used in many applications where other forms of detection are not suitable.Alarm locationThe control unit can identify along the length of the sensor cable where an alarm condition has occurred. The alarm location is then indicated on the display of the controller. Both zone are displayed at the same time.OperationThe ADE range of digital LHD cables contains a pair of twisted low resistance tri-metallic conductors sheathed with advanced temperature sensitive polymers. The cable operates by softening the insulation of the conductors the tension of the twisted conductors then causes the two cores to fuse together. The sensor cable is used in combination with the controller and end-of-line EOL unit and can connected to any fire monitoring equipment through any monitored input i.e. conventional detection zone or addressable interface unit to signal an alarm condition.Cable fixings for all applicationsA range of edge A P and T clips allow the cable to be properly installed. The clips provide heat insulation as well as holding the cable at the correct distance from cable trays steel works ceilings and walls.Key FeaturesEN54-282016 approvedLow-Smoke Zero HalogenUp to 1000 mDetection along total cable lengthFlame retardant

GBP 2640.92
1

Kidde Airsense EST-CU-11LT Control Unit 11 control slots

Kidde Airsense EST-CU-11LT Control Unit 11 control slots

Kidde Airsense EST-CU-11LT Control Unit 11 control slotsESTCU-11LT Control Unit CU is a matrix mixer of input signals which routes to 4 x 100 V internal audio buses a 45-channel digital system buses or directly to audio outputs in a unit. EST-CU-11LT is designed to work for small PA VE systems or as an extension unit in more complex systems. It means that the CU can function independently as the central unit of a small system or be part of a large complex system for which it represents another level of either territorial extension operation in a remote structure or functional extension operation of further fire zones and loudspeaker lines in such a structure.The modular design of the CU and its flexibility enables optimization of equipment and cost efficiency regardless of size number of structures their location and connectivity.In the event of losing connectivity with a networked master unit ESTCU-11LT is able to perform fire alarm scenarios independently thanks to the configuration recorded locally. While attached to the main communication ring of the system EST-CU-11LT can control amplifiers and power supply managers as well as receive alarm and digital signals and send them to other system devices.EST-CU-11LT Control Unit distributes audio signals to individual zones and ensures that individual zones function properly. It also controls the condition of loudspeaker lines and amplifiers.If a fault is detected it sends the signal to the system and automatically switches to a backup amplifier. The CU is equipped with an EST-cAudIO-412 card offering 4 symmetrical line audio inputs and 12 symmetrical outputs to lead audio signals out to external devices or amplifiers of the EST ENT VES system.Key FeaturesCompliance with EN54-16Network-based system allowing configuration diagnostics andmanagement via EthernetManaging up to 254 devices on the network11 slots available for any configuration of loudspeaker control cards andcontrol input output cardsBuilt-in audio card with 4 inputs and 12 audio outputsUp to 12 messages played simultaneously in different zonesUp to 32 GB SD flash memory designated for playback and recordingmessages 48 kHz 16 bit1x POE portSupport of up to 12 secured amplifiersBuilt-in 2 control inputs and outputs2x 1 GB ports available for system extensionIntegrated DSP with implemented 3 band parametric EQ on all inputs oncontrol units 8 band parametric EQ delay lines audio limiter andfeedback eliminator on each of the audio outputsComprehensive solution based on RS485 functionality enablingseamless integration of the EST ENT VES system with 3rd partysystems thanks to implementation of standard and proprietarycommunication interfaces

GBP 1823.00
1

Kidde Airsense EST-CU-11LCD Control Unit with LCD 11 control slots

Kidde Airsense EST-CU-11LCD Control Unit with LCD 11 control slots

Kidde Airsense EST-CU-11LCD Control Unit with LCD 11 control slotsESTCU-11LT Control Unit CU is a matrix mixer of input signals which routes to 4 100 V internal audio buses a 45-channel digital system buses or directly to audio outputs in a unit.EST-CU-11LT is designed to work for small PA VE systems or as an extension unit in more complex systems.It means that the CU can function independently as the central unit of a small system or be part of a large complex system for which it represents another level of either territorial extension operation in a remote structure or functional extension operation of further fire zones and loudspeaker lines in such a structure.The modular design of the CU and its flexibility enables optimization of equipment and cost efficiency regardless of size number of structures their location and connectivity. In the event of losing connectivity with a networked master unit ESTCU-11LT is able to perform fire alarm scenarios independently thanks to the configuration recorded locally. While attached to the main communication ring of the system EST-CU-11LT can control amplifiers and power supply managers as well as receive alarm and digital signals and send them to other system devices.EST-CU-11LT Control Unit distributes audio signals to individual zones and ensures that individual zones function properly. It also controls the condition of loudspeaker lines and amplifiers. If a fault is detected it sends the signal to the system and automatically switches to a backup amplifier.The CU is equipped with an EST-cAudIO-412 card offering 4 symmetrical line audio inputs and 12 symmetrical outputs to lead audio signals out to external devices or amplifiers of the EST ENT VES system. Furthermore EST-CU-11LT can be equipped with an LCD touch screen with a control module which allows easy access to management functions and monitoring of the whole system such extended configuration is included in EST-CU-11LCD Control Unit.Key FeaturesCompliance with EN54-16Network-based system allowing configuration diagnostics andmanagement via EthernetManaging up to 254 devices on the network11 slots available for any configuration of loudspeaker control cards andcontrol input output cardsBuilt-in audio card with 4 inputs and 12 audio outputsUp to 12 messages played simultaneously in different zonesUp to 32 GB SD flash memory designated for playback and recordingmessages 48 kHz 16 bit1x POE portSupport of up to 12 secured amplifiersBuilt-in 2 control inputs and outputs2x 1 GB ports available for system extensionIntegrated DSP with implemented 3 band parametric EQ on all inputs oncontrol units 8 band parametric EQ delay lines audio limiter andfeedback eliminator on each of the audio outputsComprehensive solution based on RS485 functionality enablingseamless integration of the EST ENT VES system with 3rd partysystems thanks to implementation of standard and proprietarycommunication interfaces

GBP 2213.64
1

Kidde Airsense EST-CU-8LCD Control Unit - 8 Control Slots 4 Function Slots

Kidde Airsense EST-CU-8LCD Control Unit - 8 Control Slots 4 Function Slots

Kidde Airsense EST-CU-8LCD Control Unit - 8 Control Slots 4 Function SlotsESTCU-8LCD Control Unit CU is a matrix mixer of input signals which routes to 4 x 100 V internal audio buses a 45-channel digital system buses or directly to audio outputs in a unit.In basic factory configuration EST-CU-8LCD is a stand-alone system which enables only connections with DFMS and zone microphones.For networking with other CU optional xNet card is needed.The CU is equipped with 1x EST-xCtrLine-4 card in slot 1 1x ESTAudIO-48-RS card in slot A and 1x EST-LogIN-8f card in slot B. Slot C and D can extend control unit audio dsp abilities up to 24 audio outputs 12 audio inputs. Slots from 2 to 7 are free for any cards assignment EST-xCtrLine-24 and EST-xLogINOUT.Furthermore EST-CU-8LCD is equipped with an LCD touch screen with a control module which allows easy access to management functions and monitoring of the whole system.Key Features Network-based system allowing configuration diagnostics and management via EthernetManaging up to 254 devices on the network7 slots available for any configuration of loudspeaker control cards control input and output cardsAdditional 2 slots designated for audio inputoutput cards and control input output cardsUp to 8 messages played simultaneously in different zonesUp to 32GB SD flash memory designated for playback and recording messages 48 kHz 16 bitSupport of up to 12 secured amplifiersOptional equipment EST-xNET-1GbWANRS for optical fibre redundant connectionIntegrated DSP with implemented 3 band parametric EQ on all inputs on control units 8 band parametric EQ delay lines audio limiter and feedback eliminator on each of the audio outputsComprehensive solution based on RS485 functionality enabling seamless integration of the EST ENT VES system with 3rd party systems thanks to implementation of standard and proprietary communication interfaces

GBP 1953.20
1