19 results (0,14232 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Kidde Airsense AAECU EN 54-22 Analogue LHD Composite Control Unit Alarmline II EN54

Kidde Airsense EST-VES-4001-L PAVA EST Voice Evacuation System

Kidde Airsense EST-VES-4001-L PAVA EST Voice Evacuation System

Kidde Airsense EST-VES-4001-L PAVA EST Voice Evacuation System 4xAB 8 lines amp 2x320W inc. spare amp. 1xaudio LCD fireman mic charger wo batteriesEST VES is scalable Public Address Voice Alarm unit suitable for multi-purpose architectures. Devices from EST VES series are voice alarm compact control units containing all components within one compact housing which meet all the requirements of EN 54-16 and EN 54-4 certificate of constancy of performance 1438-CPR-XXXX.Whole concept of the system is based on the high quality audio network distribution nodes equipped either with two independent 160 W or 320 W class D amplifiers which distribute 100 V signals to 4 or 8 speaker lines depending on the type. The system also ensures operation of a backup amplifier for the Emergency priority type of signals.EST VES is equipped with integrated backup power supply and EN 54-4 compliant charging unit. EST VES is designed to be a Plug Play device with all elements expected from Voice Evacuation Systems including a built-in fire microphone touchscreen for global control DSP programmable contact inputs and buttons time scheduler charged with battery mounting space and expandable memory size for messages all fitted into IP30 chassis.EST VES belongs to the family of independent EVAC systems which can be networked together and extended by desktop zone microphones or fireman microphones via TCPIP network to provide live announcements and background music inputs. The system has been designed to be wired using CAT5 cables for paging microphones and fibre-optic redundant interlink connections between the systems.EST VES support up to 45 high quality audio signals distributed over 254 devices in the network.Key FeaturesStandalone or TCPIP network architectureAll in one independent wall mount EN 54-4 16 PAVA unitImpedance speaker monitoringRemote managementUp to 254 devices can be connected on the network incl. fireman and zone microphonesAbility to connect standalone EST VES units via fibre optic copper or both cables. Compatibility with RACK mounted modular EST ENT VESDSP audio processing on boardProfessional Sound QualityEvacuation paging message and background music featuresSimple installationUser friendly and intuitive programming software

GBP 3359.02
1

Kidde Airsense EST-VES-4001-LN PAVA EST Voice Evacuation System

Kidde Airsense EST-VES-4001-LN PAVA EST Voice Evacuation System

Kidde Airsense EST-VES-4001-LN PAVA EST Voice Evacuation System4xAB 8 lines amp 2x320W inc. spare amp. 1xaudio LCD fibre network card fireman mic. charger wo batteriesEST VES is scalable Public Address Voice Alarm unit suitable for multi-purpose architectures. Devices from EST VES series are voice alarm compact control units containing all components within one compact housing which meet all the requirements of EN 54-16 and EN 54-4 certificate of constancy of performance 1438-CPR-XXXX.Whole concept of the system is based on the high quality audio network distribution nodes equipped either with two independent 160 W or 320 W class D amplifiers which distribute 100 V signals to 4 or 8 speaker lines depending on the type. The system also ensures operation of a backup amplifier for the Emergency priority type of signals.EST VES is equipped with integrated backup power supply and EN 54-4 compliant charging unit. EST VES is designed to be a Plug Play device with all elements expected from Voice Evacuation Systems including a built-in fire microphone touchscreen for global control DSP programmable contact inputs and buttons time scheduler charger with battery mounting space and expandable memory size for messages all fitted into IP30 chassis.EST VES belongs to the family of independent EVAC systems which can be networked together and extended by desktop zone microphones or fireman microphones via TCPIP network to provide live announcements and background music inputs. The system has been designed to be wired using CAT5 cables for paging microphones and fibre-optic redundant interlink connections between the systems.EST VES support up to 45 high quality audio signals distributed over 254 devices in the network.Key FeaturesStand alone or TCPIP network architectureAll in one independent wall mount EN 54-4 16 PAVA unitImpedance speaker monitoringRemote managementUp to 254 devices can be connected on the network incl. fireman and zone microphonesAbility to connect standalone EST VES units via fibre optic copper or both cables. Compatibility with RACK mounted modular EST ENT VESDSP audio processing on boardProfessional Sound QualityEvacuation paging message and background music featuresSimple installationUser friendly and intuitive programming software

GBP 4043.26
1

Kidde Airsense EST-VES-4002-LN PAVA EST Voice Evacuation System

Kidde Airsense EST-VES-4002-LN PAVA EST Voice Evacuation System

Kidde Airsense EST-VES-4002-LN PAVA EST Voice Evacuation System4xAB indep. 8 lines amp. 2x320W inc. spare amp. 2xaudio LCDfiber network card fireman mic. charger wo batteriesEST VES is scalable Public Address Voice Alarm unit suitable for multi-purpose architectures. Devices from EST VES series are voice alarm compact control units containing all components within one compact housing which meet all the requirements of EN 54-16 and EN 54-4 certificate of constancy of performance 1438-CPR-XXXX.Whole concept of the system is based on the high quality audio network distribution nodes equipped either with two independent 160 W or 320 W class D amplifiers which distribute 100 V signals to 4 or 8 speaker lines depending on the type. The system also ensures operation of a backup amplifier for the Emergency priority type of signals.EST VES is equipped with integrated backup power supply and EN 54-4 compliant charging unit. EST VES is designed to be a Plug Play device with all elements expected from Voice Evacuation Systems including a built-in fire microphone touchscreen for global control DSP programmable contact inputs and buttons time scheduler charger with battery mounting space and expandable memory size for messages all fitted into IP30 chassis.EST VES belongs to the family of independent EVAC systems which can be networked together and extended by desktop zone microphones or fireman microphones via TCPIP network to provide live announcements and background music inputs. The system has been designed to be wired using CAT5 cables for paging microphones and fibre-optic redundant interlink connections between the systems.EST VES support up to 45 high quality audio signals distributed over 254 devices in the network.Key FeaturesStand alone or TCPIP network architectureAll in one independent wall mount EN 54-4 16 PAVA unitImpedance speaker monitoringRemote managementUp to 254 devices can be connected on the network incl. fireman and zone microphonesAbility to connect standalone EST VES units via fibre optic copper or both cables. Compatibility with RACK mounted modular EST ENT VESDSP audio processing on boardProfessional Sound QualityEvacuation paging message and background music featuresSimple installationUser friendly and intuitive programming software

GBP 4306.37
1

Kidde Airsense EST-VES-4002-L PAVA EST Voice Evacuation System

Kidde Airsense EST-VES-4002-L PAVA EST Voice Evacuation System

Kidde Airsense EST-VES-4002-L PAVA EST Voice Evacuation System4xAB indep. 8 lines amp. 2x320W inc. spare amp. 2xaudio LCD fireman mic. charger wo batteriesEST VES is scalable Public Address Voice Alarm unit suitable for multi-purpose architectures. Devices from EST VES series are voice alarm compact control units containing all components within one compact housing which meet all the requirements of EN 54-16 and EN 54-4 certificate of constancy of performance 1438-CPR-XXXX.Whole concept of the system is based on the high quality audio network distribution nodes equipped either with two independent 160 W or 320 W class D amplifiers which distribute 100 V signals to 4 or 8 speaker lines depending on the type. The system also ensures operation of a backup amplifier for the Emergency priority type of signals.EST VES is equipped with integrated backup power supply and EN 54-4 compliant charging unit. EST VES is designed to be a Plug Play device with all elements expected from Voice Evacuation Systems including a built-in fire microphone touchscreen for global control DSP programmable contact inputs and buttons time scheduler charger with battery mounting space and expandable memory size for messages all fitted into IP30 chassis.EST VES belongs to the family of independent EVAC systems which can be networked together and extended by desktop zone microphones or fireman microphones via TCPIP network to provide live announcements and background music inputs. The system has been designed to be wired using CAT5 cables for paging microphones and fibre-optic redundant interlink connections between the systems.EST VES support up to 45 high quality audio signals distributed over 254 devices in the network.Key FeaturesStand alone or TCPIP network architectureAll in one independent wall mount EN 54-4 16 PAVA unitImpedance speaker monitoringRemote managementUp to 254 devices can be connected on the network incl. fireman and zone microphonesAbility to connect standalone EST VES units via fibre optic copper or both cables. Compatibility with RACK mounted modular EST ENT VESDSP audio processing on boardProfessional Sound QualityEvacuation paging message and background music featuresSimple installationUser friendly and intuitive programming software

GBP 3402.77
1

Kidde Airsense ADELCU-2 Alarmline II Digital LHD EN54-28 Dual Zone Location Control Unit

Kidde Airsense ADELCU-2 Alarmline II Digital LHD EN54-28 Dual Zone Location Control Unit

Kidde Airsense ADELCU-2 Alarmline II Digital LHD EN54-28 Dual Zone Location Control UnitThe ADELCU-2 digital location control unit is a dual zone module for monitoring up to two zones of AlarmLine II Digital EN Linear Heat Detection Cable. If an overheat or fire situation triggers either zone of the digital cable the unit automatically calculates and displays the distance along the cable in feet and metres to the alarm point.The two zones can operate independently of each other or in interlock mode. A separate alarm and normally conducting fault output are provided for each zone. The unit is intended to be installed between the AlarmLine II digital EN linear heat detection cable and a conventional or addressable fire alarm control panel. It has power fault and alarm indicators as well as free outputs for fault and alarm corresponding to each zone. It may also be connected to a industrial process control system using the two wire RS-485 Modbus RTU output.Modbus communicationThe unit includes a two wire RS-485 Modbus output which can be enabled to output the status of each zone of the digital location control unit via Modbus RTUASCII protocol. In case of an alarm the location in distance along the cable is also communicated via Modbus.Interconnecting cableThe unit supports the use of a interconnecting cable leader cable in between the control unit and the linear heat detection cable. The interconnecting cable is used in applications where the control unit is not located in the detection zone. The interconnecting cable is then used to connect the control unit in one location with the linear heat detection cable in the protected area. The interconnecting cable is available in 100 m lengths under the product code AAI-0100.Key FeaturesDual Zone - used as Independent or InterlockDesigned for AlarmLine II Digital EN linear heat cableEasy to installIP Rating IP65RoHS compliant CE EN54-282016 certifiedModbus support1km of cable supported per zoneWide supply voltageLow current consumption

GBP 1253.77
1

Kidde 2X-AT-F2-P Addressable Fire Panel Touch Screen With UI - 2 Loop Big PSU

Kidde 2X-AT-F2-S Addressable Fire Panel Touch Screen With UI - 2 Loop Small CAB

Kidde Airsense EST-PSM48 Power Supply Manager

Kidde 2X-AT-F2 Addressable Fire Panel Touch Screen With UI - 2 Loop

Kidde 2X-AT-F2-FB-P Addressable Fire Panel Touch Screen With UI FB Control - 2 Loop Big PSU

Kidde 2X-AT-F2-FB-S Addressable Fire Panel Touch Screen With UI FB Control - 2 Loop Small CAB

Kidde Airsense EST-PS48800 Power Supply

Kidde Airsense EST-PS48800 Power Supply

Kidde Airsense EST-PS48800 Power SupplyEST-PSM48 Power Supply Manager is designed for distribution of DC Power Supply from Power Supply Units PSU and a back-up battery. The unit controls battery charging and distributes power supply to all Voice Evacuation System VES equipment at max 60 A. When the system uses battery back-up the power supplied is 3.2 kW 48 V.The unit complies with the EN 54-4 VES standards and also EN 12101-10 Smoke and Heat Control System standards. As a main source of energy distribution the manager uses external modules 800 W EST-PS48800 for 48 V.As a source of stand-by power supply it uses the battery bank of the capacity of up to 200 Ah.EST-PSM48 cooperates with the 4 x 12 V VRLA battery bank. It maintains the bank in charged condition ensures temperature compensation of charging parameters and monitors serial resistance of the battery and its wiring as specified in Exhibit No. A2 to the EN54-4 Standard.EST-PSM48 co-operates with up to 4 modules of EST-PS4880 Power Supply Units. The manager ensures safe connection for the purpose of parallel operations and monitors the output parameters of each power supply unit.EST-PS48800 is designed for assembling in a dedicated EST-PF4 Power Supply Unit Frame. The elements of the system are designed for assembling in a Rack 19 IP30-type.Key FeaturesPower consumption 885 W max. 3.85 AAC power supply 230 VAC 10 -15 5060Hz 3.85 A Wire with IEC 60320 C13 3x075 mm2 coupling supplied with the unitCertification EN54-4Standards EN12101-10

GBP 697.18
1

Kidde Airsense EST-PA1650B Power Amplifier D-Class 1x650 Watt

Kidde Airsense EST-PA1650B Power Amplifier D-Class 1x650 Watt

Kidde Airsense EST-PA1650B Power Amplifier D-Class 1x650 WattThe Amplifiers are designed for perfect integration into the EST solutions. Thanks to their flexibility they can also be used for any other Public Address and Voice Evacuation applications. These amplifiers have been developed to meet the specific requirements of the EN 54-16 standard for safety installations.The EST-PAXXXXB is a family of 2U rack mountable 8-channel ESTPA8080B ESTPA-8160B 4 channel EST-PA4160B 2 channel high power EST-PA2650B and 1 channel EST-PA1650B class-D transformer isolated power amplifiers for 50 V and 100 V distributed loudspeaker systems. Amplifier EST-PA8080B can deliver up to 8 x 80 W for EST-PA8160B and EST-PA2650B delivering power increases respectively to the 8 x 160 W and 2 x 650 W. In a bridged mode amplifier channels are combined and can deliver 4 x 160 W for ESTPA8080B 4 x 320 W for EST-PA8160B and 1 x 1300 W for ESTPA2650B. These amplifiers have 48 VDC input which allows to connect with battery backup system for maximum availability and durability in a voice evacuation system.The EST-PAXXXXB amplifiers are powered from external power supply module EST-PS48800 working in a block. The current from block is distributed to individual amplifiers through the power manager EST-PSM48 device includes a battery charger and is in compliance with EN 54-4.Key FeaturesFront panel indicators include Supply Active Fault100 50 Volt available via terminal blocks at the rearEST-PAXXXXB combines with the EST-PSM48 Power Supply Manager charger and back-up supply

GBP 1102.58
1

Kidde Airsense EST-PA2650B Power Amplifier D-Class 2x650 Watt

Kidde Airsense EST-PA2650B Power Amplifier D-Class 2x650 Watt

Kidde Airsense EST-PA2650B Power Amplifier D-Class 2x650 WattThe Amplifiers are designed for perfect integration into the EST solutions. Thanks to their flexibility they can also be used for any other Public Address and Voice Evacuation applications. These amplifiers have been developed to meet the specific requirements of the EN 54-16 standard for safety installations.The EST-PAXXXXB is a family of 2U rack mountable 8-channel ESTPA8080B ESTPA-8160B 4 channel EST-PA4160B 2 channel high power EST-PA2650B and 1 channel EST-PA1650B class-D transformer isolated power amplifiers for 50 V and 100 V distributed loudspeaker systems. Amplifier EST-PA8080B can deliver up to 8 x 80 W for EST-PA8160B and EST-PA2650B delivering power increases respectively to the 8 x 160 W and 2 x 650 W. In a bridged mode amplifier channels are combined and can deliver 4 x 160 W for ESTPA8080B 4 x 320 W for EST-PA8160B and 1 x 1300 W for ESTPA2650B. These amplifiers have 48 VDC input which allows to connect with battery backup system for maximum availability and durability in a voice evacuation system.The EST-PAXXXXB amplifiers are powered from external power supply module EST-PS48800 working in a block. The current from block is distributed to individual amplifiers through the power manager EST-PSM48 device includes a battery charger and is in compliance with EN 54-4.Key FeaturesFront panel indicators include Supply Active Fault100 50 Volt available via terminal blocks at the rearOutput channels can be linked into 1 x 1300 W by daisy-chaining 50 V tapping input on parallelEST-PAXXXXB combines with the EST-PSM48 Power Supply Manager charger and back-up supply

GBP 1420.36
1

Kidde Airsense EST-PA4160B Power Amplifier D-Class 4x160 Watt

Kidde Airsense EST-PA4160B Power Amplifier D-Class 4x160 Watt

Kidde Airsense EST-PA4160B Power Amplifier D-Class 4x160 WattThe Amplifiers are designed for perfect integration into the EST solutions. Thanks to their flexibility they can also be used for any other Public Address and Voice Evacuation applications. These amplifiers have been developed to meet the specific requirements of the EN 54-16 standard for safety installations.The EST-PAXXXXB is a family of 2U rack mountable 8-channel ESTPA8080B ESTPA-8160B 4 channel EST-PA4160B 2 channel high power EST-PA2650B and 1 channel EST-PA1650B class-D transformer isolated power amplifiers for 50 V and 100 V distributed loudspeaker systems. Amplifier EST-PA8080B can deliver up to 8 x 80 W for EST-PA8160B and EST-PA2650B delivering power increases respectively to the 8 x 160 W and 2 x 650 W. In a bridged mode amplifier channels are combined and can deliver 4 x 160 W for ESTPA8080B 4 x 320 W for EST-PA8160B and 1 x 1300 W for ESTPA2650B. These amplifiers have 48 VDC input which allows to connect with battery backup system for maximum availability and durability in a voice evacuation system.The EST-PAXXXXB amplifiers are powered from external power supply module EST-PS48800 working in a block. The current from block is distributed to individual amplifiers through the power manager EST-PSM48 device includes a battery charger and is in compliance with EN 54-4.Key FeaturesFront panel indicators include Supply Active Fault100 50 Volt available via terminal blocks at the rearOutput channels can be linked into 2 x 320 W by daisy-chaining 50 V tapping input on parallelEST-PAXXXXB combines with the EST-PSM48 Power Supply Manager charger and back-up supply

GBP 1764.64
1

Kidde Airsense EST-PA8080B Power Amplifier D-Class 8x80 Watt

Kidde Airsense EST-PA8080B Power Amplifier D-Class 8x80 Watt

Kidde Airsense EST-PA8080B Power Amplifier D-Class 8x80 WattThe Amplifiers are designed for perfect integration into the EST solutions. Thanks to their flexibility they can also be used for any other Public Address and Voice Evacuation applications. These amplifiers have been developed to meet the specific requirements of the EN 54-16 standard for safety installations.The EST-PAXXXXB is a family of 2U rack mountable 8-channel ESTPA8080B ESTPA-8160B 4 channel EST-PA4160B 2 channel high power EST-PA2650B and 1 channel EST-PA1650B class-D transformer isolated power amplifiers for 50 V and 100 V distributed loudspeaker systems. Amplifier EST-PA8080B can deliver up to 8 x 80 W for EST-PA8160B and EST-PA2650B delivering power increases respectively to the 8 x 160 W and 2 x 650 W. In a bridged mode amplifier channels are combined and can deliver 4 x 160 W for ESTPA8080B 4 x 320 W for EST-PA8160B and 1 x 1300 W for ESTPA2650B. These amplifiers have 48 VDC input which allows to connect with battery backup system for maximum availability and durability in a voice evacuation system.The EST-PAXXXXB amplifiers are powered from external power supply module EST-PS48800 working in a block. The current from block is distributed to individual amplifiers through the power manager EST-PSM48 device includes a battery charger and is in compliance with EN 54-4.Key FeaturesFront panel indicators include Supply Active Fault100 50 Volt available via terminal blocks at the rearOutput channels can be linked into 4 x 160 W by daisy-chaining 50 V tapping input on parallelEST-PAXXXXB combines with the EST-PSM48 Power Supply Manager charger and back-up supply

GBP 1833.41
1

Kidde Airsense EST-PA8160B Power Amplifier D-Class 8x160 Watt

Kidde Airsense EST-PA8160B Power Amplifier D-Class 8x160 Watt

Kidde Airsense EST-PA8160B Power Amplifier D-Class 8x160 WattThe Amplifiers are designed for perfect integration into the EST solutions. Thanks to their flexibility they can also be used for any other Public Address and Voice Evacuation applications. These amplifiers have been developed to meet the specific requirements of the EN 54-16 standard for safety installations.The EST-PAXXXXB is a family of 2U rack mountable 8-channel ESTPA8080B ESTPA-8160B 4 channel EST-PA4160B 2 channel high power EST-PA2650B and 1 channel EST-PA1650B class-D transformer isolated power amplifiers for 50 V and 100 V distributed loudspeaker systems. Amplifier EST-PA8080B can deliver up to 8 x 80 W for EST-PA8160B and EST-PA2650B delivering power increases respectively to the 8 x 160 W and 2 x 650 W. In a bridged mode amplifier channels are combined and can deliver 4 x 160 W for ESTPA8080B 4 x 320 W for EST-PA8160B and 1 x 1300 W for ESTPA2650B. These amplifiers have 48 VDC input which allows to connect with battery backup system for maximum availability and durability in a voice evacuation system.The EST-PAXXXXB amplifiers are powered from external power supply module EST-PS48800 working in a block. The current from block is distributed to individual amplifiers through the power manager EST-PSM48 device includes a battery charger and is in compliance with EN 54-4.Key FeaturesFront panel indicators include Supply Active Fault100 50 Volt available via terminal blocks at the rearOutput channels can be linked into 4 x 320 W by daisy-chaining 50 V tapping input on parallelEST-PAXXXXB combines with the EST-PSM48 Power Supply Manager charger and back-up supply

GBP 2459.23
1

Kidde 2X-AF1-FB-S Addressable Fire Panel With Fire Brigade Controls and UI - 1 Loop - Small Cabinet

Kidde 2X-AF1-FB-S Addressable Fire Panel With Fire Brigade Controls and UI - 1 Loop - Small Cabinet

Kidde 2X-AF1-FB-S Addressable Fire Panel With Fire Brigade Controls and UI - 1 Loop - Small CabinetThe new 2X-A series life safety control systems bring the speed and functionality of high-end intelligent processing to small to mid-sized addressable applications. Based on 2X series learned experience and with complete backwards compatibility the new 2X-A features an attractive contemporary design that fits with any decor. With improved robustness manufactured in metal special plastics and easy electronics removal it allows painting in any colour. The main controls are easily located using an improved and robust jog dial.With high power loop addressable detection a full line of easily configured option cards and modules as well as USB and Ethernet connectivity these quick-to configure systems offer versatility that benefits building owners and life safety system installers alike.The PanelThe fire panels supplied in local language with user interface with fire brigade and fire protection controls with 1 loop that supports up to 128 devices in 512 zones have standard 2 supervised sounderfire-routing outputs which can be used as freely programmable outputs as well. In addition 2 conventional relay outputs and 2 supervised outputs working in pair and dedicated to common fire and fault conditions as well as 2 user configurable inputs for monitoring and control are available.Key FeaturesUp to 128 devices 512 zones and 300 output groupsUp to 24 LED Zone indicators for Fire and Fault with space for a 4 digit numberAuto configuration setup wizards and default regional setup modesEthernet port with TCPIP for remote diagnostics maintenance and programmingEN54 compliant graphical LCD with icons and up to 256 zonesImproved Jog Dial with 4 soft buttons for simple and intuitive user controlAesthetic pleasing design with robust painted steel doorEasy removable door and chassis for quick and clean installationAll pluggable connectorsAuxiliary 24 VDC supply output with reset support3 USB ports with memory stick support and RS232 for printer supportCommunication via UltraSync cloud using EN 54-21 UC240 UltraSync communicatorIntegration in management software ATS8600 allowing integration with security systems and CMS3 operator level menu structure 20 usernames and passwordsEmail notification for events directly from the panel 4 user accountsHistory log memory for 9999 eventsBackwards compatible supporting site retrofitupgrades expansions replacementCompatible with the new loop powered soundersbeacons and base sounders and the 2000 series detectors with replaceable optical chamber

GBP 683.63
1