91 results (0,16666 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Notifier DSS-PC-I02 Loop-Powered EN54-23 Open Category Detector Base Sounder Strobe - Red Flash cw Isolator

Notifier WST-PC-I02 Addressable Wall VAD Clear Lens with Red Flash

Notifier W5A-RP02SG-N026-01 IP67 Waterproof Addressable Call Point With Isolator

Notifier W5A-RP02SG-N026-01 IP67 Waterproof Addressable Call Point With Isolator

Notifier M700WCP-RISG IP67 Waterproof Addressable Call Point With Isolator W5A-RP02SG-N026-01Designed to provide a manual alarm interface to NOTIFIERs fire alarm control panel. Installation efficiency flexibility and compliance with the latest standards are at the heart of the call point range.The unique plug and play concept is designed specifically to reduce installation time by using a terminal block which can be wired during the initial installation cabling with a link P102 to provide continuity for testing. During the commissioning phase the links are removed and the terminal block is simply inserted into the connector at the back of the unit. No re-termination is required. Both break glass supplied and resettable operating elements PS230 can be used in the standard unit.Operation of the re-settable element as well as being indicated by the units LED is also indicated by a yellow strip on the element which becomes visible when activated. With the addition of a hinged transparent cover PS200 the element may be protected against accidental operation and may be further protected by using a cover seal PS056 which requires breaking in order to operate the unit.Key FeaturesUnique Plug Play installation conceptRe-settable operating element optionAnalogue addressable communicationsSemi-Flush or surface mountingFully compliant with EN54 Part 11Backward compatibilityEnhanced aestheticsIntegral LEDIntegral loop isolation option

GBP 257.96
1

Notifier ECO1003A ECO Photoelectric Smoke Detector

Notifier ECO1003A ECO Photoelectric Smoke Detector

Notifier ECO1003A ECO Photoelectric Smoke DetectorThe ECO1003 A photoelectric smoke detector belongs to System Sensors ECO1000 range of detectors. ECO1000 is a range of conventional detectors which have been produced using the latest in manufacturing technology and supplied with an array of advanced features making them better by design.The ECO1003 A photoelectric smoke detector uses a state of the art optical chamber combined with an application specific integrated circuit ASIC to provide quick and accurate detection of fires. A combination of the unique chamber design and other technically advanced features will significantly extend the service intervals before cleaning of the detector becomes necessary.A laser-based hand held Remote Test Unit can be used in conjunction with the range of ECO1000 detectors for alarm test purposes. The unit transmits a coded message preventing spurious alarms being generated by other laser-based devices. With a range of several metres the hand held test unit provides a fast and simple way of remotely alarm testing the range of ECO1000 detectors and removes the need for any direct physical access to the detector by the useThe ECO1003 A detector has an integral LED which illuminates to provide a local alarm signal. This latches on and remains illuminated until the detector is reset by a momentary power interruption. An optional remote LED annunciator may be used to repeat any alarm signal.A variety of detector bases can be used with the ECO1003 A detector providing application flexibility and compatibility with a wide range of Fire Alarm Control Panels. All bases are fitted with a shorting spring to permit circuit testing prior to fitting the detector and have a tamper resistant feature which when activated prevents removal of the detector without the use of a tool. All System Sensor products are covered by our extended 3-year warranty.Key FeaturesLow profile designLow current drawAutomatic drift compensationOperates on 12 and 24VDC SystemsRemote alarm test featureEasy MaintenanceApproved to EN54 72000Approved to MED 9698ECExtended warranty

GBP 23.45
1

Notifier SD-851TE Conventional Multi Detector

Notifier Honeywell 6 Watt Flush Mounted Wall Loudspeaker 582425

Notifier HOP-402-100 Charger Module 1 Supplied

Notifier NRX-WSF-RR Wall-Mounted Addressable Wireless Sounder Beacon - REDRED

Notifier NRX-WSF-RR Wall-Mounted Addressable Wireless Sounder Beacon - REDRED

Notifier NRX-WSF-RR Wall-Mounted Addressable Wireless Sounder Beacon - REDREDThe Agile Wireless Fire Detection and Alarm System is a platform of wireless fire devices suitable for all applications where wired fire devices cannot be installed for economic or aesthetic reasons. The look and feel of our wired fire devices combined with cutting edge wireless mesh network technology delivers superior performance when compared to traditional wireless star network technologies.MeshThe Agile wireless platform is powered by robust mesh network technology providing up to two communication paths to each wireless device. This makes the network highly reliable protecting against broken communication links. Mesh network technology enables flexible and economic installations in a wide variety of building footprints.IntegrationThe Agile Wireless Fire Detection System is an extension of the product range. It features the same class leading device design detection performance false alarm immunity and system functionality. Wireless devices can be seamlessly integrated into existing systems giving the fire system the flexibility to be easily extended.SoftwareAll operations for the design configuration and diagnostics of the Agile Wireless Fire Detection System be facilitated by the AgileIQ PC based software tool. It enables the PC to exchange information with the wireless devices without any hardwired connection by means of a wireless USB dongle. The management software will run under Windows operating systems ranging from Windows XP to Windows 10.

GBP 335.83
1

Notifier NRX-WSF-WR Wall-Mounted Addressable Wireless Sounder Beacon - WHITERED

Notifier NRX-WSF-WR Wall-Mounted Addressable Wireless Sounder Beacon - WHITERED

Notifier NRX-WSF-WR Wall-Mounted Addressable Wireless Sounder Beacon - WHITEREDThe Agile Wireless Fire Detection and Alarm System is a platform of wireless fire devices suitable for all applications where wired fire devices cannot be installed for economic or aesthetic reasons. The look and feel of our wired fire devices combined with cutting edge wireless mesh network technology delivers superior performance when compared to traditional wireless star network technologies.MeshThe Agile wireless platform is powered by robust mesh network technology providing up to two communication paths to each wireless device. This makes the network highly reliable protecting against broken communication links. Mesh network technology enables flexible and economic installations in a wide variety of building footprints.IntegrationThe Agile Wireless Fire Detection System is an extension of the product range. It features the same class leading device design detection performance false alarm immunity and system functionality. Wireless devices can be seamlessly integrated into existing systems giving the fire system the flexibility to be easily extended.SoftwareAll operations for the design configuration and diagnostics of the Agile Wireless Fire Detection System be facilitated by the AgileIQ PC based software tool. It enables the PC to exchange information with the wireless devices without any hardwired connection by means of a wireless USB dongle. The management software will run under Windows operating systems ranging from Windows XP to Windows 10.

GBP 335.83
1

Notifier Honeywell 6 Watt Ceiling Speaker For Shallow Ceiling Voids 582407.SAFE

Notifier Honeywell DCS Plus Digital Call Station 583520

Notifier Honeywell DCS Plus Digital Call Station 583520

Notifier Honeywell DCS Plus Digital Call Station 583520The digital call station DCS plus allow the selection of loudspeaker circuits the transmission of voice announcements as well as various gongs and alarms. The digital call station is connectable via a standard CAT5 cable to the VARIODYN D1 control devices DOM and Comprio. All control signals up to four simultaneous audio signals and the power supply are transmitted. This connection can be done by single or redundant cabling up to 300 m away.It can be increased to 20 Kilometers by using fiber-optic cabling. The digital call station DCS plus can be expanded with up to six digital keyboard modules DKM plus whereby the total number of available keys and LEDs increases to 120 per communication station. The function of the microphone and the cable connection is permanently monitored. The DCS plus provides an additional external audio input and output which can be used to connect audio devices such as CD players. A 3 m long CAT5 cable to connect the digital call station to a wall jack is included.Key FeaturesHigh failure safety due to redundant transmission routeCost-effective CAT5 cablingElectret gooseneck microphone with cardioid patternExchangeable gooseneck microphone with protection by using a specific tool to lockunlockPermanent monitoring of the microphone and cableMechanical protection against cable disconnectionBuild-in loudspeaker for monitoring and for intercom operation between other paging stationsIndependent additional audio inputoutput e.g. for audio player12 freely configurable keys with independent programmable LEDs

GBP 1928.22
1

Notifier Analogue Addressable Optical Smoke Detector - White NFXI-OPT

Notifier NFXI-OPT-BK Analogue Addressable Optical Smoke Detector - Black

Notifier Local Silence Button Kit NF-SIL-BKIT

Notifier Local Silence Button Kit NF-SIL-BKIT

Notifier Local Silence Button Kit NF-SIL-BKITThe NOTIFIER Local Silence Button in conjunction with the advanced programmingprovided by the Pearl control panel enables the use of a full BS5839 Part 1 system inapplications such as assisted living retirement homes student accommodation highrise residential buildings. Often the risk of false alarm in such buildings has led to thesesorts of installation being provided with individual systems for the flats linked to alandlord system for the shared area.The use of the NOTIFIER local silence button and Type-B dependency programmingnow enables full BS 5839 Part 1 systems to be installed in all areas.Type B DependencyType B dependency allows a zone to be defined for each individual flat that acts as ifit were a separate system. On receipt of an unconfirmed fire signal from a flat onlythe local alarm within the flat is given. If the alarm is confirmed by a second signal thesystem proceeds to the relevant evacuation stage general alarm or part of stagedevacuation. Alternatively if the confirmation signal is not given the system may resetautomatically without attendance by facility management staff.Local Silence ButtonThe local silence button is a multi-position switch that allows not only sounder test andsilencing but also disablement of smoke detection and the indication of disablement. Aswith other features it is flexible in configuration so that the facilities may be tailored tosuit each site.NOTIFIER NF-SIL-BKIT LOCAL SILENCE BUTTON KIT FEATURESBest detection throughout. AllowsOpal multi criteria detectors to reducefalse alarms.Fully configurable. Allowing theinstaller to design delay periods andresponse times on all parts of thesystem in order to ensure it meetsyour building requirements.Flexible and simple to install. TheLocal Silence Button is available in a kitincluding wiring loom and loop moduleSupporting compliance. BS5839 Part6 requires the alarm in each dwellingto be tested on a regular basis. Thisactivity is logged on the Pearl systemallowing landlords to check theresidents are performing this taskensuring fire safety and compliance.Local Silence of an AlarmThe user is able to silence the local sounder or sounder beacons within their premisesby pressing the Fire Alarm Silence button when a detector has activated within theirpremises. When the site is in a full evacuation mode this feature is disabled and thelocal sounder or sounder beacons cannot be silenced by the user.Local DisablementIf the user believes that they may generate an unwanted alarm from a smoke detectorwithin their premises they can press and hold the Fire Alarm Silence button for 5seconds. The yellow LED illuminates which will then disable the detection in that zoneonly for a configurable period of between 5-15 minutes in accordance with BS5839 Part 6.At the end of the configured period the zone will automatically re-enable all detectionwill be active and the LED will be extinguished.Local TestA test feature is available which allows the user to operate the sounder or sounderbeacons within the local zone by pressing and holding down the Fire Alarm Testbutton once released the sounder or sounder beacons will silence.ConnectionThe button is connected to the Pearl loop via a Notifier 21 dual input single outputinterface unit and a 5-core cable.

GBP 287.16
1

Notifier HOP-134-412 Notifier INSPIRE E15 Panel With 12-Module Slots

Notifier HOP-131-206 Notifier INSPIRE E10 Panel With 6-Module Slots

Notifier ABT-TNL100-1 Tunnel Horn Loudspeaker - 100 W with 76 horizontal x 90 Vertical Display

Notifier ABT-TNL100-1 Tunnel Horn Loudspeaker - 100 W with 76 horizontal x 90 Vertical Display

Notifier ABT-TNL100-1 Tunnel Horn Loudspeaker - 100 W with 76 horizontal x 90 Vertical DisplayIn case of an emergency the Voice Evacuation System needs to guide people in the tunnel to safety so the audio transmission should be as clear as possible. In general due to high levels of reverberation and noise a tunnel is not an ideal environment for Voice Evacuation System and therefore speech intelligibility becomes a critical parameter for any voice alarm application. To establish a sufficient level of speech intelligibility a highly directional speakers system is required. By reducing the energy emitted to other surfaces reflective sound energy can be minimized which results in a better direct to reverberant ratio. This will improve the maximum feasible speech intelligibility. To minimize disturbing echo effects resulting in a loss of speech intelligibility each horn speaker is driven by an individual signal channel in a 100 V installation which is equipped with audio DSP including EQ and delay. Our product S4T Safety For Tunnel offers the most effective solution which seamlessly combines a dedicated Voice Evacuation System with tailored Tunnel Loudspeakers.Key FeaturesSpecially designed for tunnel applicationsHighly directional asymmetric hornExcellent speech intelligibilityStainless steel constructionWaterproof housing IP66High power output 10050 WCompliance with BS5839-8 standard Thermal protection

GBP 4521.70
1

Notifier ABT-TNL100 Tunnel Horn Loudspeaker - 100 W with 25 horizontal x 35 Vertical Display

Notifier ABT-TNL100 Tunnel Horn Loudspeaker - 100 W with 25 horizontal x 35 Vertical Display

Notifier ABT-TNL100 Tunnel Horn Loudspeaker - 100 W with 25 horizontal x 35 Vertical DisplayIn case of an emergency the Voice Evacuation System needs to guide people in the tunnel to safety so the audio transmission should be as clear as possible. In general due to high levels of reverberation and noise a tunnel is not an ideal environment for Voice Evacuation System and therefore speech intelligibility becomes a critical parameter for any voice alarm application. To establish a sufficient level of speech intelligibility a highly directional speakers system is required. By reducing the energy emitted to other surfaces reflective sound energy can be minimized which results in a better direct to reverberant ratio. This will improve the maximum feasible speech intelligibility. To minimize disturbing echo effects resulting in a loss of speech intelligibility each horn speaker is driven by an individual signal channel in a 100 V installation which is equipped with audio DSP including EQ and delay. Our product S4T Safety For Tunnel offers the most effective solution which seamlessly combines a dedicated Voice Evacuation System with tailored Tunnel Loudspeakers.Key FeaturesSpecially designed for tunnel applicationsHighly directional asymmetric hornExcellent speech intelligibilityStainless steel constructionWaterproof housing IP66High power output 10050 WCompliance with BS5839-8 standard Thermal protection

GBP 7985.12
1

Notifier M701E-240 Output Control Module Protocol 240VAC Relay Contact Rating

Notifier PRL-LED-EN Pearl Fixed 2 Loop Intelligent Fire Alarm Control Panel with 64 LEDs

Notifier PRL-LED-EN Pearl Fixed 2 Loop Intelligent Fire Alarm Control Panel with 64 LEDs

Notifier PRL-LED-EN Pearl Fixed 2 Loop Intelligent Fire Alarm Control Panel with 64 LEDsThe Pearl fire alarm control panel from Notifier by Honeywell is a robust and easy to use networkable 1 or 2 loop panel. It exploits Notifiers class leading Opal digital protocol to maximise the speed and efficiency of fire detection and alarm. The large display with its intuitive interface and menu driven features allows quick and easy operation of the system.Coupled with more power and devices on the loop than other panels in its class the simple design will allow for trouble-free first fix installation. Compatible with the ID2net network used by the ID3000 the Pearl panel is supported by an integrated tools suite to enhance and simplify the system management.Extended capacityThe Pearl supports up to 636 loop devices 159 detectors plus 159 modules per loopLonger loops but fewer of them will give the opportunity to save on installation time cost and wiringHighly resilient Opal system able to pinpoint a loop fault whilst maintaining full system operationPowerful networking capability - Up to 16 Pearl panels controlling over 10000 devices can be networked via the superfast ID2net prioritising a fire signal to communicate across a network in under three secondsEase of useIntuitive on-site management - backlit buttons for fast error free situation management and large display giving complete information at a glanceSimpler diagnostics and maintenance - panel control of detector LEDs enabling confirmation of detector statusText programming via MS Excel spread sheetUser permissions set per individual passwordFlexibilityUnique first fix bracket with adaptations for 19 rack or flush mounting.Fast system set up and commissioning via the panel loop Autolearn and advanced PC tools suiteComprehensive Cause Effect programming capabilityPanel sounder and beacon synchronisationSystem extensions and adaptations can be made quickly without compromising fire cover and without extensive re-cablingSeparate text change without risk to Cause Effect or system configuration.Ability to run BS5839 part 6 system for HMO

GBP 2044.22
1

Notifier PRL-LED-EN-1 Pearl Fixed 1 Loop Intelligent Fire Alarm Control Panel with 64 LEDs

Notifier PRL-LED-EN-1 Pearl Fixed 1 Loop Intelligent Fire Alarm Control Panel with 64 LEDs

Notifier PRL-LED-EN-1 Pearl Fixed 1 Loop Intelligent Fire Alarm Control Panel with 64 LEDsThe Pearl fire alarm control panel from Notifier by Honeywell is a robust and easy to use networkable 1 or 2 loop panel. It exploits Notifiers class leading Opal digital protocol to maximise the speed and efficiency of fire detection and alarm. The large display with its intuitive interface and menu driven features allows quick and easy operation of the system.Coupled with more power and devices on the loop than other panels in its class the simple design will allow for trouble-free first fix installation. Compatible with the ID2net network used by the ID3000 the Pearl panel is supported by an integrated tools suite to enhance and simplify the system management.Extended capacityThe Pearl supports up to 636 loop devices 159 detectors plus 159 modules per loopLonger loops but fewer of them will give the opportunity to save on installation time cost and wiringHighly resilient Opal system able to pinpoint a loop fault whilst maintaining full system operationPowerful networking capability - Up to 16 Pearl panels controlling over 10000 devices can be networked via the superfast ID2net prioritising a fire signal to communicate across a network in under three secondsEase of useIntuitive on-site management - backlit buttons for fast error free situation management and large display giving complete information at a glanceSimpler diagnostics and maintenance - panel control of detector LEDs enabling confirmation of detector statusText programming via MS Excel spread sheetUser permissions set per individual passwordFlexibilityUnique first fix bracket with adaptations for 19 rack or flush mounting.Fast system set up and commissioning via the panel loop Autolearn and advanced PC tools suiteComprehensive Cause Effect programming capabilityPanel sounder and beacon synchronisationSystem extensions and adaptations can be made quickly without compromising fire cover and without extensive re-cablingSeparate text change without risk to Cause Effect or system configuration.Ability to run BS5839 part 6 system for HMO

GBP 1619.16
1

Notifier Honeywell 582461 IC Audio DL-54 K 20-165T-EN 20 Watt Spherical Speaker

Notifier NFXI-MM10 Ten-way Input Module with Loop Isolation