292 results (0,16139 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Notifier UT232R-200 USB to RS232 UploadDownload Lead - Windows 10

Notifier Honeywell Contact Interface Module CIM 583341.21

Notifier Honeywell Digital call station UIM multimode FO converter to DCS or UIM 583317.21

Notifier Honeywell ETCS Ethernet Touchscreen Call Station 583527

Notifier Honeywell ETCS Ethernet Touchscreen Call Station 583527

Notifier Honeywell ETCS Ethernet Touchscreen Call Station 583527ETCS adopts 7 touch screen for display and operation which provides a user-friendly interface. 4 bi-colour LEDs are used for status indications which include microphone fault indication system fault indication and connection states of two redundant cables. A red button with cover can be configured for emergency announcement.The gooseneck microphone is replaceable and monitored by ETCS. The loudspeaker can be used for pre-listening audio locally and intercom between the call stations. ETCS is prepared for redundant cable connection to the Ethernet network. It can be powered by PoE devices through the Ethernet cable or with a power adapter. USB stick can be connected to ETCS to make it easy to play external audio files. ETCS provides an external audio input and output which can be used for connecting audio devices such as CD players. If more keys andor LEDs are needed it is possible to add up to three digital key modules DKM plus 583526.ETCS can monitor the microphone and cables permanently. It can also be monitored and configured via the network. It supports multi-language display and the languages can be switched dynamically without resetting the device. It also supports playback the recent call quickly. There are three types of user permissions which can provide different layouts and operations for each user. Up to 27 h. speech or audio can be saved and played locally. Two icons are used to indicate if there is any call been activated or system fault been occurred. Active call list system fault list and recent call list can easily be checked in any page.ETCS supports manual calls or pre-defined calls or schedule calls as home page. For manual calls after selecting the target zones andor groups four different audio sources can be selected which include USB stick audio local storage audio network audio and live announcement. For pre-defined calls when the call is activated it will directly play pre-recorded messages on target zonesgroups which are all configured in advance by configuration tool. The call volume can be adjusted during the calls. For schedule calls after configuring the call parameters and playback time it will directly start at the specified time.Key Features7 touch screen and user friendly interface4 bi-colour LEDs for status indicationA red button with cover for emergency announcementReplaceable electret gooseneck microphone with uni-directional patternLoudspeaker for pre-listening audio locally and intercom between the call stations ETCS and DCS seriesHigh failure safety due to redundant transmission routeNetwork cable via EthernetPowered by PoE devices or external power adapterUSB stick can be connected to play audio filesAdditional audio inputoutput for audio devicesMax 3 key modules DKM plus which has 18 keys and 18 LEDs each can be extendedPermanent monitoring of the microphone and cablesRemote monitoring and configuration via the networkSupport multi-language displayThree types of user permissions for different layouts and operationsSpeech or audio memory up to 27 h.Active call list system fault list and recent call list can easily be checked in any pageSupport manual calls pre-defined calls and schedule calls which can be set as home pageVolume can be adjusted during the calls

GBP 2754.02
1

Notifier NFXI-TDIFF-BK A1R Rate Of Rise amp Fixed Heat Detector - Black

Notifier NFXI-TDIFF-BK A1R Rate Of Rise amp Fixed Heat Detector - Black

Notifier NFXI-TDIFF-BK A1R Rate Of Rise Fixed Heat Detector - BlackThis is the Black Version of the NFXI-TDIFF.The Opal NFXI-TFIX58 NFXI-TFIX78 are fixed temperature analogue addressable sensors employing low mass thermistors and microprocessor technology for fast response and linear temperature sensing. Their linear response allows these sensors to be used to signal temperatures over the range of 58C Class A1S to 78C Class BS.The Opal NFXI-TDIFF uses the same thermistor and microprocessor technology to provide an alarm when the rate of rise in temperature exceeds 10Cminute typical or if the temperature exceeds a threshold of 58C Response Class A1R. Notifiers Opal protocol allows it to be software configured to be either a fixed 58C a fixed 78C unit or a 58C with rate of rise device.For backwards compatibility and approval continuity three separate versions continue to be available as separate part numbers. The sensing elements of all three heat sensors are panel controllable through the Opal Protocol so the sensitivity thresholds of each element can be changed by the panel offering the ability to customise the device for the changing use of the area it is protecting. The detectors have built in short circuit isolation and two integral tri-colour LEDs that provide 360 local visual indication of the device status. The LEDs are programmable with static or blinking red amber and green status indications available.Key FeaturesBuilt in short circuit isolationNew advanced Opal protocol allows mapping of the loop for precise fault location using isolatorsTri colour LED offering red green and amber coloursRotary decade address switchesPure white colour to complement modern buildings100 mechanical and electrical backwards compatibilityBase designed to ease installation and wiring

GBP 85.99
1

Notifier NFX-TFIX58-IV Fixed Temperature 58 Deg. Heat Detector - Ivory

Notifier NFX-TFIX58-IV Fixed Temperature 58 Deg. Heat Detector - Ivory

Notifier NFX-TFIX58-IV Fixed Temperature 58 Deg. Heat Detector - IvoryThe Opal NFXI-TFIX58 NFXI-TFIX78 are fixed temperature analogue addressable sensors employing low mass thermistors and microprocessor technology for fast response and linear temperature sensing. Their linear response allows these sensors to be used to signal temperatures over the range of 58C Class A1S to 78C Class BS.The Opal NFXI-TDIFF uses the same thermistor and microprocessor technology to provide an alarm when the rate of rise in temperature exceeds 10Cminute typical or if the temperature exceeds a threshold of 58C Response Class A1R. Notifiers Opal protocol allows it to be software configured to be either a fixed 58C a fixed 78C unit or a 58C with rate of rise device.For backwards compatibility and approval continuity three separate versions continue to be available as separate part numbers. The sensing elements of all three heat sensors are panel controllable through the Opal Protocol so the sensitivity thresholds of each element can be changed by the panel offering the ability to customise the device for the changing use of the area it is protecting. The detectors have built in short circuit isolation and two integral tri-colour LEDs that provide 360 local visual indication of the device status. The LEDs are programmable with static or blinking red amber and green status indications available.Key FeaturesBuilt in short circuit isolationNew advanced Opal protocol allows mapping of the loop for precise fault location using isolatorsTri colour LED offering red green and amber coloursRotary decade address switchesPure white colour to complement modern buildings100 mechanical and electrical backwards compatibilityBase designed to ease installation and wiring

GBP 97.34
1

Notifier NFXI-TDIFF A1R Rate Of Rise amp Fixed Heat Detector - White

Notifier NFXI-TDIFF A1R Rate Of Rise amp Fixed Heat Detector - White

Notifier NFXI-TDIFF A1R Rate Of Rise Fixed Heat DetectorThe Opal NFXI-TFIX58 NFXI-TFIX78 are fixed temperature analogue addressable sensors employing low mass thermistors and microprocessor technology for fast response and linear temperature sensing. Their linear response allows these sensors to be used to signal temperatures over the range of 58C Class A1S to 78C Class BS.The Opal NFXI-TDIFF uses the same thermistor and microprocessor technology to provide an alarm when the rate of rise in temperature exceeds 10Cminute typical or if the temperature exceeds a threshold of 58C Response Class A1R. Notifiers Opal protocol allows it to be software configured to be either a fixed 58C a fixed 78C unit or a 58C with rate of rise device. For backwards compatibility and approval continuity three separate versions continue to be available as separate part numbers.The sensing elements of all three heat sensors are panel controllable through the Opal Protocol so the sensitivity thresholds of each element can be changed by the panel offering the ability to customise the device for the changing use of the area it is protecting. The detectors have built in short circuit isolation and two integral tri-colour LEDs that provide 360 local visual indication of the device status. The LEDs are programmable with static or blinking red amber and green status indications available.Key FeaturesBuilt in short circuit isolationNew advanced Opal protocol allows mapping of the loop for precise fault location using isolatorsTri colour LED offering red green and amber coloursRotary decade address switchesPure white colour to complement modern buildings100 mechanical and electrical backwards compatibilityBase designed to ease installation and wiring

GBP 55.16
1

Notifier Fixed Temperature 78 Deg. Heat Detector - NFX-TFIX78-IV - Ivory

Notifier Fixed Temperature 78 Deg. Heat Detector - NFX-TFIX78-IV - Ivory

Notifier Fixed Temperature 78 Deg. Heat Detector - NFX-TFIX78-IV - IvoryThe Opal NFXI-TFIX58 NFXI-TFIX78 are fixed temperature analogue addressable sensors employing low mass thermistors and microprocessor technology for fast response and linear temperature sensing. Their linear response allows these sensors to be used to signal temperatures over the range of 58C Class A1S to 78C Class BS.The Opal NFXI-TDIFF uses the same thermistor and microprocessor technology to provide an alarm when the rate of rise in temperature exceeds 10Cminute typical or if the temperature exceeds a threshold of 58C Response Class A1R. Notifiers Opal protocol allows it to be software configured to be either a fixed 58C a fixed 78C unit or a 58C with rate of rise device. For backwards compatibility and approval continuity three separate versions continue to be available as separate part numbers.The sensing elements of all three heat sensors are panel controllable through the Opal Protocol so the sensitivity thresholds of each element can be changed by the panel offering the ability to customise the device for the changing use of the area it is protecting. The detectors have built in short circuit isolation and two integral tri-colour LEDs that provide 360 local visual indication of the device status. The LEDs are programmable with static or blinking red amber and green status indications available.Key Features Built in short circuit isolationNew advanced Opal protocol allows mapping of the loop for precise fault location using isolatorsTri colour LED offering red green and amber coloursRotary decade address switchesPure white colour to complement modern buildings100 mechanical and electrical backwards compatibilityBase designed to ease installation and wiring

GBP 97.34
1

Notifier Fixed Temperature 58 Deg. Heat Detector NFXI-TFIX58 - White

Notifier Fixed Temperature 58 Deg. Heat Detector NFXI-TFIX58 - White

Notifier Fixed Temperature 58 Deg. Heat DetectorThe Opal NFXI-TFIX58 NFXI-TFIX78 are fixed temperature analogue addressable sensors employing low mass thermistors and microprocessor technology for fast response and linear temperature sensing. Their linear response allows these sensors to be used to signal temperatures over the range of 58C Class A1S to 78C Class BS.The Opal NFXI-TDIFF uses the same thermistor and microprocessor technology to provide an alarm when the rate of rise in temperature exceeds 10Cminute typical or if the temperature exceeds a threshold of 58C Response Class A1R. Notifiers Opal protocol allows it to be software configured to be either a fixed 58C a fixed 78C unit or a 58C with rate of rise device. For backwards compatibility and approval continuity three separate versions continue to be available as separate part numbers.The sensing elements of all three heat sensors are panel controllable through the Opal Protocol so the sensitivity thresholds of each element can be changed by the panel offering the ability to customise the device for the changing use of the area it is protecting. The detectors have built in short circuit isolation and two integral tri-colour LEDs that provide 360 local visual indication of the device status. The LEDs are programmable with static or blinking red amber and green status indications available.Key Features Built in short circuit isolationNew advanced Opal protocol allows mapping of the loop for precise fault location using isolatorsTri colour LED offering red green and amber coloursRotary decade address switchesPure white colour to complement modern buildings100 mechanical and electrical backwards compatibilityBase designed to ease installation and wiring

GBP 58.40
1

Notifier Fixed Temperature 78 Deg. Heat Detector NFXI-TFIX78 - White

Notifier Fixed Temperature 78 Deg. Heat Detector NFXI-TFIX78 - White

Notifier Fixed Temperature 78 Deg. Heat DetectorThe Opal NFXI-TFIX58 NFXI-TFIX78 are fixed temperature analogue addressable sensors employing low mass thermistors and microprocessor technology for fast response and linear temperature sensing. Their linear response allows these sensors to be used to signal temperatures over the range of 58C Class A1S to 78C Class BS.The Opal NFXI-TDIFF uses the same thermistor and microprocessor technology to provide an alarm when the rate of rise in temperature exceeds 10Cminute typical or if the temperature exceeds a threshold of 58C Response Class A1R. Notifiers Opal protocol allows it to be software configured to be either a fixed 58C a fixed 78C unit or a 58C with rate of rise device. For backwards compatibility and approval continuity three separate versions continue to be available as separate part numbers.The sensing elements of all three heat sensors are panel controllable through the Opal Protocol so the sensitivity thresholds of each element can be changed by the panel offering the ability to customise the device for the changing use of the area it is protecting. The detectors have built in short circuit isolation and two integral tri-colour LEDs that provide 360 local visual indication of the device status. The LEDs are programmable with static or blinking red amber and green status indications available.Key FeaturesBuilt in short circuit isolationNew advanced Opal protocol allows mapping of the loop for precise fault location using isolatorsTri colour LED offering red green and amber coloursRotary decade address switchesPure white colour to complement modern buildings100 mechanical and electrical backwards compatibilityBase designed to ease installation and wiring

GBP 58.40
1

Notifier NFX-TDIFF-IV A1R Rate Of Rise amp Fixed Heat Detector - Ivory

Notifier NFX-TDIFF-IV A1R Rate Of Rise amp Fixed Heat Detector - Ivory

Notifier NFX-TDIFF-IV A1R Rate Of Rise Fixed Heat Detector - IvoryThe Opal NFXI-TFIX58 NFXI-TFIX78 are fixed temperature analogue addressable sensors employing low mass thermistors and microprocessor technology for fast response and linear temperature sensing. Their linear response allows these sensors to be used to signal temperatures over the range of 58C Class A1S to 78C Class BS.The Opal NFXI-TDIFF uses the same thermistor and microprocessor technology to provide an alarm when the rate of rise in temperature exceeds 10Cminute typical or if the temperature exceeds a threshold of 58C Response Class A1R. Notifiers Opal protocol allows it to be software configured to be either a fixed 58C a fixed 78C unit or a 58C with rate of rise device. For backwards compatibility and approval continuity three separate versions continue to be available as separate part numbers.The sensing elements of all three heat sensors are panel controllable through the Opal Protocol so the sensitivity thresholds of each element can be changed by the panel offering the ability to customise the device for the changing use of the area it is protecting. The detectors have built in short circuit isolation and two integral tri-colour LEDs that provide 360 local visual indication of the device status. The LEDs are programmable with static or blinking red amber and green status indications available.Key Features Built in short circuit isolationNew advanced Opal protocol allows mapping of the loop for precise fault location using isolatorsTri colour LED offering red green and amber coloursRotary decade address switchesPure white colour to complement modern buildings100 mechanical and electrical backwards compatibilityBase designed to ease installation and wiring

GBP 94.10
1

Notifier NFX-MM1M Addressable Mini Monitor input module

Notifier Honeywell DCS Plus Digital Call Station 583520

Notifier Honeywell DCS Plus Digital Call Station 583520

Notifier Honeywell DCS Plus Digital Call Station 583520The digital call station DCS plus allow the selection of loudspeaker circuits the transmission of voice announcements as well as various gongs and alarms. The digital call station is connectable via a standard CAT5 cable to the VARIODYN D1 control devices DOM and Comprio. All control signals up to four simultaneous audio signals and the power supply are transmitted. This connection can be done by single or redundant cabling up to 300 m away.It can be increased to 20 Kilometers by using fiber-optic cabling. The digital call station DCS plus can be expanded with up to six digital keyboard modules DKM plus whereby the total number of available keys and LEDs increases to 120 per communication station. The function of the microphone and the cable connection is permanently monitored. The DCS plus provides an additional external audio input and output which can be used to connect audio devices such as CD players. A 3 m long CAT5 cable to connect the digital call station to a wall jack is included.Key FeaturesHigh failure safety due to redundant transmission routeCost-effective CAT5 cablingElectret gooseneck microphone with cardioid patternExchangeable gooseneck microphone with protection by using a specific tool to lockunlockPermanent monitoring of the microphone and cableMechanical protection against cable disconnectionBuild-in loudspeaker for monitoring and for intercom operation between other paging stationsIndependent additional audio inputoutput e.g. for audio player12 freely configurable keys with independent programmable LEDs

GBP 1928.22
1

Notifier ID3002 2 Loop Intelligent Fire Alarm Control Panel

Notifier ID3002 2 Loop Intelligent Fire Alarm Control Panel

Notifier ID3002 2 Loop Intelligent Fire Alarm Control PanelThe Notifier ID3000 family of fire alarm control panels deliver the power and flexibility to meet the even the most demanding of requirements. From 2 to 8 loops in a single ID3000 panel to over 500 loops on a network an ID3000 system offers unrivalled stability versatility and capacity. When it comes to giving you the earliest possible warning of a potential fire threat the ID3000 supports Notifiers comprehensive range of detectors advanced fire detection sensors and loop devices delivering you the most complete and versatile fire alarm system in the market place.The ID3000 can be programmed to adapt to the different uses of the areas where smoke detectors are installed. A total of 9 different sensitivity levels can be assigned to individual smoke sensors thereby allowing the system designer to closely match the sensors response to the environment in which the device is located. This even allows smoke detection to be turned off leaving heat detection active.Key Features2-8 Analogue Addressable Loops each of up to 198 devices255 Fire zones per panelFully approved peer to peer network of up to 63 panels maintains 3 second call point response time over the networkFlexible timer functions system sensitivity and functionality can be tailored for the time of day or day of weekSophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems.Convenience features for commissioning and maintenance engineers such as auto-learn of loops walk test and double address detection.CPD approved by LPCB BRE VdS

GBP 2933.30
1

Notifier PRN-ID Printer Kit for ID61 ID62 ID2000 ID3000 020-644-009

Notifier W5A-RP02SG-N026-01 IP67 Waterproof Addressable Call Point With Isolator

Notifier W5A-RP02SG-N026-01 IP67 Waterproof Addressable Call Point With Isolator

Notifier M700WCP-RISG IP67 Waterproof Addressable Call Point With Isolator W5A-RP02SG-N026-01Designed to provide a manual alarm interface to NOTIFIERs fire alarm control panel. Installation efficiency flexibility and compliance with the latest standards are at the heart of the call point range.The unique plug and play concept is designed specifically to reduce installation time by using a terminal block which can be wired during the initial installation cabling with a link P102 to provide continuity for testing. During the commissioning phase the links are removed and the terminal block is simply inserted into the connector at the back of the unit. No re-termination is required. Both break glass supplied and resettable operating elements PS230 can be used in the standard unit.Operation of the re-settable element as well as being indicated by the units LED is also indicated by a yellow strip on the element which becomes visible when activated. With the addition of a hinged transparent cover PS200 the element may be protected against accidental operation and may be further protected by using a cover seal PS056 which requires breaking in order to operate the unit.Key FeaturesUnique Plug Play installation conceptRe-settable operating element optionAnalogue addressable communicationsSemi-Flush or surface mountingFully compliant with EN54 Part 11Backward compatibilityEnhanced aestheticsIntegral LEDIntegral loop isolation option

GBP 257.96
1

Notifier NRX-WSF-RR Wall-Mounted Addressable Wireless Sounder Beacon - REDRED

Notifier NRX-WSF-RR Wall-Mounted Addressable Wireless Sounder Beacon - REDRED

Notifier NRX-WSF-RR Wall-Mounted Addressable Wireless Sounder Beacon - REDREDThe Agile Wireless Fire Detection and Alarm System is a platform of wireless fire devices suitable for all applications where wired fire devices cannot be installed for economic or aesthetic reasons. The look and feel of our wired fire devices combined with cutting edge wireless mesh network technology delivers superior performance when compared to traditional wireless star network technologies.MeshThe Agile wireless platform is powered by robust mesh network technology providing up to two communication paths to each wireless device. This makes the network highly reliable protecting against broken communication links. Mesh network technology enables flexible and economic installations in a wide variety of building footprints.IntegrationThe Agile Wireless Fire Detection System is an extension of the product range. It features the same class leading device design detection performance false alarm immunity and system functionality. Wireless devices can be seamlessly integrated into existing systems giving the fire system the flexibility to be easily extended.SoftwareAll operations for the design configuration and diagnostics of the Agile Wireless Fire Detection System be facilitated by the AgileIQ PC based software tool. It enables the PC to exchange information with the wireless devices without any hardwired connection by means of a wireless USB dongle. The management software will run under Windows operating systems ranging from Windows XP to Windows 10.

GBP 335.83
1

Notifier NRX-WSF-WR Wall-Mounted Addressable Wireless Sounder Beacon - WHITERED

Notifier NRX-WSF-WR Wall-Mounted Addressable Wireless Sounder Beacon - WHITERED

Notifier NRX-WSF-WR Wall-Mounted Addressable Wireless Sounder Beacon - WHITEREDThe Agile Wireless Fire Detection and Alarm System is a platform of wireless fire devices suitable for all applications where wired fire devices cannot be installed for economic or aesthetic reasons. The look and feel of our wired fire devices combined with cutting edge wireless mesh network technology delivers superior performance when compared to traditional wireless star network technologies.MeshThe Agile wireless platform is powered by robust mesh network technology providing up to two communication paths to each wireless device. This makes the network highly reliable protecting against broken communication links. Mesh network technology enables flexible and economic installations in a wide variety of building footprints.IntegrationThe Agile Wireless Fire Detection System is an extension of the product range. It features the same class leading device design detection performance false alarm immunity and system functionality. Wireless devices can be seamlessly integrated into existing systems giving the fire system the flexibility to be easily extended.SoftwareAll operations for the design configuration and diagnostics of the Agile Wireless Fire Detection System be facilitated by the AgileIQ PC based software tool. It enables the PC to exchange information with the wireless devices without any hardwired connection by means of a wireless USB dongle. The management software will run under Windows operating systems ranging from Windows XP to Windows 10.

GBP 335.83
1

Notifier Honeywell Power Amplifier 4 x 250w 100 Class D 580243

Notifier Honeywell Power Amplifier 4 x 250w 100 Class D 580243

Notifier Honeywell Power Amplifier 4 x 250w 100 Class D 580243Four-channel amplifier with integrated battery recharging system for the emergency power supply to the VARIODYN D1 Comprio. The 4XD250B features 4 independent amplifier channels each with 250 W in class D direct drive technology. Due to the fact that all amplifier channels are completely independent from each other it is possible to use one channel for back up.This could be for the other 3 channels or alternatively for other amplifier channels of other amplifiers with the same or lower output power only 4XDxxxB and 4XDxxxW models. The amplifier can be used in combination with the VARIODYN D1 Comprio as well as with a DOM. It is also possible to use the amplifier also with a separate PSU the internal PSU must be switched of then. In this case the internal battery charger must be disabled.Key FeaturesEN 54-4 and EN 54-16 certifiedCompliant with EN 60849 and EN 50849Class D technology efficiency 80 4 independent amplifier channelsOne of four amplifier channels can be used as general back up channelTwo Height Unit 2 HUIdeal for use with the VARIODYN D1 ComprioSelf-monitoring and self-test by microcontrollerProtected against overload short circuit and overheatingSmooth and fast step-down in 1dB steps in the event of overdrive or over load24 V DC PSU for back up mains powerIntegrated battery charger according to EN 54-4 for charging batteries up to a capacity of 65 Ah 2 x 12 V 105 Ah for emergency power supply of the amplifier and one Comprio or DOMTemperature controlled variable speed fans

GBP 5451.26
1

Notifier Local Silence Button Kit NF-SIL-BKIT

Notifier Local Silence Button Kit NF-SIL-BKIT

Notifier Local Silence Button Kit NF-SIL-BKITThe NOTIFIER Local Silence Button in conjunction with the advanced programmingprovided by the Pearl control panel enables the use of a full BS5839 Part 1 system inapplications such as assisted living retirement homes student accommodation highrise residential buildings. Often the risk of false alarm in such buildings has led to thesesorts of installation being provided with individual systems for the flats linked to alandlord system for the shared area.The use of the NOTIFIER local silence button and Type-B dependency programmingnow enables full BS 5839 Part 1 systems to be installed in all areas.Type B DependencyType B dependency allows a zone to be defined for each individual flat that acts as ifit were a separate system. On receipt of an unconfirmed fire signal from a flat onlythe local alarm within the flat is given. If the alarm is confirmed by a second signal thesystem proceeds to the relevant evacuation stage general alarm or part of stagedevacuation. Alternatively if the confirmation signal is not given the system may resetautomatically without attendance by facility management staff.Local Silence ButtonThe local silence button is a multi-position switch that allows not only sounder test andsilencing but also disablement of smoke detection and the indication of disablement. Aswith other features it is flexible in configuration so that the facilities may be tailored tosuit each site.NOTIFIER NF-SIL-BKIT LOCAL SILENCE BUTTON KIT FEATURESBest detection throughout. AllowsOpal multi criteria detectors to reducefalse alarms.Fully configurable. Allowing theinstaller to design delay periods andresponse times on all parts of thesystem in order to ensure it meetsyour building requirements.Flexible and simple to install. TheLocal Silence Button is available in a kitincluding wiring loom and loop moduleSupporting compliance. BS5839 Part6 requires the alarm in each dwellingto be tested on a regular basis. Thisactivity is logged on the Pearl systemallowing landlords to check theresidents are performing this taskensuring fire safety and compliance.Local Silence of an AlarmThe user is able to silence the local sounder or sounder beacons within their premisesby pressing the Fire Alarm Silence button when a detector has activated within theirpremises. When the site is in a full evacuation mode this feature is disabled and thelocal sounder or sounder beacons cannot be silenced by the user.Local DisablementIf the user believes that they may generate an unwanted alarm from a smoke detectorwithin their premises they can press and hold the Fire Alarm Silence button for 5seconds. The yellow LED illuminates which will then disable the detection in that zoneonly for a configurable period of between 5-15 minutes in accordance with BS5839 Part 6.At the end of the configured period the zone will automatically re-enable all detectionwill be active and the LED will be extinguished.Local TestA test feature is available which allows the user to operate the sounder or sounderbeacons within the local zone by pressing and holding down the Fire Alarm Testbutton once released the sounder or sounder beacons will silence.ConnectionThe button is connected to the Pearl loop via a Notifier 21 dual input single outputinterface unit and a 5-core cable.

GBP 287.16
1

Notifier ID3000 4 Loop Addressable Control Panel with 4.5A Power Supply 020-727

Notifier ID3000 4 Loop Addressable Control Panel with 4.5A Power Supply 020-727

Notifier ID3000 4 Loop Addressable Control Panel with 4.5A Power Supply 020-727The Notifier ID3000 family of fire alarm control panels deliver the power and flexibility to meet the even the most demanding of requirements. From 2 to 8 loops in a single ID3000 panel to over 500 loops on a network an ID3000 system offers unrivalled stability versatility and capacity. When it comes to giving you the earliest possible warning of a potential fire threat the ID3000 supports Notifiers comprehensive range of detectors advanced fire detection sensors and loop devices delivering you the most complete and versatile fire alarm system in the market place.The ID3000 can be programmed to adapt to the different uses of the areas where smoke detectors are installed. A total of 9 different sensitivity levels can be assigned to individual smoke sensors thereby allowing the system designer to closely match the sensors response to the environment in which the device is located. This even allows smoke detection to be turned off leaving heat detection active.Key Features2-8 Analogue Addressable Loops each of up to 198 devices255 Fire zones per panelFully approved peer to peer network of up to 63 panels maintains 3 second call point response time over the networkFlexible timer functions system sensitivity and functionality can be tailored for the time of day or day of weekSophisticated cause and effect programming including support for non-fire signals and over-ride capability for smoke control systems.Convenience features for commissioning and maintenance engineers such as auto-learn of loops walk test and double address detection.CPD approved by LPCB BRE VdSKit Includes1 x 020-538 - Basic Equipment kit 2-8 Loops1 x 020-579 - 7A PSU 4.5A or 7A User selectable1 x 020-543- Dual transmittion path board kit1 x 020-588 - Dual loop board kit1 x 020-474-009 - Extended deep back-box kit Space for up to 38Ah batteries. H620mm W500mm D220mm.1 x 020-480-009 - Main cover kit1 x 020-485-009 - Extension cover blanking kit1 x 020-481-009 - Extension cover kit

GBP 4722.00
1