Vesda VHX-1400 Metal Box HLI Modbus Type 1

Vesda VHX-1410 Metal Box HLI Modbus Type 2

Vesda VHX-1320 Metal Box HLI Access Protocol

Vesda VHX-1320 Metal Box HLI Access Protocol

Vesda VHX-1320 Metal Box HLI Access ProtocolThe VESDA Access High Level Interface HLI integrates VESDAnet networks with host monitoring platforms such as Building Management Systems BMSs and Fire Alarm Control Panels FACPs. The Access HLI acts as a proxy for all VESDA devices on the VESDAnet network providing access to the rich status information available from VESDA detectors as well as the ability to control and configure these devices.The Access HLI is able to report alarms to the host within a few seconds of a detector reaching an alarm condition. Exact performance is dependent on the polling strategy and size of the monitored network. The Access HLI is able to support up to 100 VESDA detectors on a single VESDAnet network.The wall-mounted version is housed in a metal enclosure allowing for permanent mounting on a flat surface. With a built-in VESDAnet interface you dont need a remote VESDAnet socket module making the wall-mounted HLI a cost-effective solution to your interface requirements.Key FeaturesDirect access and monitoring of your entire VESDAnet networkSeamless data transferEasily configured using Xtralis configuring and monitoring software packagesProtocol SupportsVESDA VLP VLS VLC VLF VLI and VFT-15 range of DetectorsAlarm StatusFault StatusSmoke LevelDetailed Fault InformationAlarm ThresholdsDetector Control including Reset Disable Silence Alarm Test and NormaliseOperational Status for processes such as Normalisation and AutoLearnAsynchronous notification of the device state including alarm level detailed faults and current thresholds

GBP 2399.28
1

Vesda VHX-1420 Metal Box HLI Modbus Type 3

Vesda VHX-1420 Metal Box HLI Modbus Type 3

Vesda VHX-1420 Metal Box HLI Modbus Type 3The VESDA Modbus Type 3 High Level Interface HLI integrates VESDAnet network with host monitoring platforms such as Building Management Systems BMSs and Fire Alarm Control Panels FACPs. The Modbus Type 3 HLI acts as a proxy for all VESDA devices on the VESDAnet network providing access to the rich status information that is available from VESDA detectors as well as the ability to control and configure these devices. Alarms are reported to the host within a few seconds of a detector reaching an alarm condition.Exact performance is dependent on the polling strategy and size of the monitored network. The Modbus Type 3 HLI is able to support up to 100 VESDA detectors on a single VESDAnet network. The wall-mounted version is housed in a metal enclosure allowing for permanent mounting on a flat surface. With a built-in VESDAnet interface you dont need a remote VESDAnet socket module making the wall-mounted HLI a cost-effective solution to your interface requirements.Key FeaturesDirect access and monitoring of your entire VESDAnet systemSeamless data transferEasily configured using Xtralis configuring and monitoring software packagesProtocol SupportsVESDA VLP VLS VLC VLF VLI and VFT-15 detectorsVESDA-E VEP VEU and VEA detectorsAlarm StatusFault StatusSmoke LevelDetailed Fault InformationAlarm ThresholdsDetector Control including Reset Disable Silence Alarm Test and NormaliseOperational Status for processes such as Normalisation and AutoLearn

GBP 2399.28
1

Vesda VHX-1310 Metal Box HLI Master Slave

Vesda VHX-1310 Metal Box HLI Master Slave

Vesda VHX-1310 Metal Box HLI Master SlaveThe VESDA Wall-Mounted Open Protocol High Level Interface HLI links your VESDAnet1 with PC software monitoring tools Building Management Systems BMSs and Fire Alarm Control Panels FACPs otherwise known as host. With a built-in VESDAnet interface you dont need a remote VESDAnet socket module which makes the Wall-mounted HLI a cost-effective solution to your interface requirements. There are two models available depending on whether you require communication between your host and VESDAnet to be master-slave or peer-to-peer.In the master-slave model the host supervises the communications link between itself and the HLI slave by regularly polling the HLI to determine whether there has been a change in the status of a detector on VESDAnet. In response to polling by the host the HLI generates a single response which is sent back to the host. In this way no unsolicited messages are sent from the HLI to the host. Depending on the polling strategy adopted the Master Slave Open Protocol HLI is able to report any and all fire alarms within a few seconds of a detector going into alarm. Exact performance is dependent on the polling strategy adopted.Key FeaturesDirect access and monitoring of your entire VESDAnet systemSeamless data transferEasily configured using Xtralis configuring and monitoring software packages.Information available using the Open Protocol HLIDetector Type VLC VLS VLP VLF.Alarm status Alert Action Fire1 Fire2.Fault Status System Zone Urgent Power Network Flow Filter.Status Isolated Normalizing AutoLearn Scanning.Display info Alarm thresholds Location name.Display update Smoke level Alarm Fault status.Fault details list of active fault codes.Fault strings ASCII strings to describe each fault code.Detector controls Reset Isolate Silence Test Scan or Normalize2 .Configuration of Day Night alarm thresholds2

GBP 2333.39
1

Vesda VHX-1300 Metal Box HLI Peer to Peer

Vesda VHX-1300 Metal Box HLI Peer to Peer

Vesda VHX-1300 Metal Box HLI Peer to PeerThe VESDA Wall-Mounted Open Protocol High Level Interface HLI links your VESDAnet with PC software monitoring tools Building Management Systems BMSs and Fire Alarm Control Panels FACPs otherwise known as host. With a built-in VESDAnet interface you dont need a remote VESDAnet socket module which makes the Wall-mounted HLI a cost-effective solution to your interface requirements. There are two models available depending on whether you require communication between your host and VESDAnet to be master-slave or peer-to-peer.In the peer-to-peer model the host polls the HLI for information about devices on VESDAnet while the HLI sends unsolicited messages to the host. In this way both the HLI and host are responsible for supervising the communications link between them. In the peer-to-peer model the host can request and receive multiple messages from the HLI.A VESDA High Level Interface HLI enables connection between a VESDAnet and configuration and monitoring platforms. Two main models are available1 Sliding Windows HLI which enables communication between a VESDAnet and configuration and monitoring software packages Xtralis VSC and Xtralis VSM42 Open Protocol HLI which integrates a VESDAnet to third-party software packages building management systems BMSs and fire alarm control panels FACPs.These HLIs are available in a plastic portable housing which can be used in multiple sites and a fixed wall-mounted configuration to provide a permanent connection in a convenient location at one site.Key FeaturesDirect access and monitoring of your entire VESDAnet systemSeamless data transferEasily configured using Xtralis configuring and monitoring software packages.Information available using the Open Protocol HLIDetector Type VLC VLS VLP VLF.Alarm status Alert Action Fire1 Fire2.Fault Status System Zone Urgent Power Network Flow Filter.Status Isolated Normalizing AutoLearn Scanning.Display info Alarm thresholds Location name.Display update Smoke level Alarm Fault status.Fault details list of active fault codes.Fault strings ASCII strings to describe each fault code.Detector controls Reset Isolate Silence Test Scan or Normalize2 .Configuration of Day Night alarm thresholds2

GBP 2443.61
1

Vesda VLF-250 LaserFOCUS-250 Detector with Display

Vesda VLF-250 LaserFOCUS-250 Detector with Display

Vesda VLF-250 LaserFOCUS-250 Detector with DisplayThe VESDA VLF-250 detector is a very early warning smoke detector designed to protect small business-critical environments of less than 250 m2 2690 sq. ft..The detector works by continually drawing air into sampling holes in a pipe network. The air is filtered and passed into a detection chamber where light scattering technology detects the presence of very small amounts of smoke.Detector status information is communicated on the detector display and via relays or optional interface cards.Out-of-the-box OperationThe VLF can be installed and commissioned out-of-the-box without the need for a special interface or software programming tools.In operation the unique Smoke DialTM display provides the user with an instant understanding of a smoke event even from a distance. Should a fault occur the user simply opens the field service door and activates the Instant Fault Finder feature to determine the specific fault condition. This information can then be passed onto their fire service company ensuring that service technicians arrive onsite fully prepared.Ultrasonic Flow SensingThe patent-pending Ultrasonic Flow Sensing used in the VLF provides a direct reading of the sampling pipe flow rate. The system is immune to air temperature and pressure changes and is unaffected by contamination. The VLF is the first air sampling smoke detector to use ultrasonic flow sensing.Key FeaturesOut-of-the-Box Installation and CommissioningUltrasonic Airflow SensingLaser-Based Absolute Smoke DetectionPre-engineered pipe network designsProgrammable Alarm ThresholdsClean air barrier optics protectionInstant Recognition DisplayInstant Fault FinderAutoLearn SmokeAutoLearn FlowField Service Access DoorMultiple Event Logging in separate logsEvent log up to 18000 eventsOfflineonline configuration capabilityUp to 250 m2 2690 sq. ft. coverage

GBP 1253.88
1

Vesda VLF-500 LaserFOCUS-500 Detector with Display

Vesda VLF-500 LaserFOCUS-500 Detector with Display

Vesda VLF-500 LaserFOCUS-500 Detector with DisplayThe VESDA LaserFOCUS detector is a very early warning smoke detector designed to protect small business-critical environments of less than 500 m2 5000 sq. ft.The detector works by continually drawing air into sample holes in a pipe network. The air is filtered and passed into a detection chamber where light scattering technology detects the presence of very small amounts of smoke.Detector status information is communicated on the detector display and via relays or optional interface cards.Out-of-the-box OperationThe VESDA LaserFOCUS can be installed and commissioned out-of-the-box without the need for a special interface or software programming tools.In operation the unique Smoke Dial display provides the user with an instant understanding of a smoke event even from a distance. Should a fault occur the user simply opens the field service door and activates the Instant Fault Finder feature to determine the specific fault condition. This information can then be passed onto their fire service company ensuring that service technicians arrive onsite fully prepared.Ultrasonic Flow SensingThe patent-pending Ultrasonic Flow Sensing used in the LaserFOCUS provides a direct reading of the sampling pipe flow rate. The system is immune to air temperature and pressure changes and is unaffected by contamination. VESDA is the first air sampling smoke detector to use ultrasonic flow sensing.Key FeaturesOut-of-the-Box Installation and CommissioningUltrasonic Airflow SensingLaser-Based Absolute Smoke DetectionPre-engineered pipe network designsProgrammable Alarm ThresholdsDual Stage Air FiltrationInstant Recognition DisplayInstant Fault FinderAutoLearn SmokeAutoLearn FlowField Service Access DoorMultiple Event Logging in separate logsEvent log up to 18000 eventsOfflineonline configuration capabilityUp to 500 m2 5000 sq. ft. coverage

GBP 1667.36
1

Vesda Xtralis VIC-030 Multi-Functional Control Card amp Monitored Output for VLF-250 amp VLF-50

Vesda Xtralis VIC-030 Multi-Functional Control Card amp Monitored Output for VLF-250 amp VLF-50

Vesda Xtralis VIC-030 Multi-Functional Control Card Monitored Output for VLF-250 VLF-50The VESDA VLF MCC Multi-function Control Card is an interface card for the range of Xtralis VESDA VLF smoke detectors. An MCC expands the range of input and output communications a VLF detector can perform.Why use a VLF MCCInstalling a VLF MCC into a VLF detector provides a cost-effective solution for customers who need enhanced connectivity fault detection and monitoring and annunciation of alarms and faults. The principal benefits includeImproved FACP connectivity The VLF is fitted with two 2 alarm relays in its standard form. With an extra two 2 relays the Multi-function Control Card allows reporting of all four 4 alarm levels on dry relay outputs.Enhanced annunciation An MPO Monitored 24 V Powered Output is available on the VIC-030 version of the card. The MPO provides power to devices such as sirens or strobes and monitors the line integrity.Enhanced control and fault detection With a VLF MCC installed a VLF has two 2 General Purpose Inputs GPIs allowing for example one GPI to report on loss of mains power and the other GPI to be used as a reset input. The VIC-030 version of the card has a self-configuring GPI depending on the jumper selection for MPORelay3.If MPO is selected activation of the GPI will disable the MPO.If Relay3 is selected the GPI will be set to External Fault e.g. for mains power supply monitoring.Key FeaturesProvides two 2 additional relaysProvides an extra General-Purpose Input GPI with line monitoringQuick and simple to installOut-of-the-box operation with minimal configuration required for extra featuresDiagnostic LEDs give visual indication of the cards statusFully compatible with Xtralis VESDA VLF smoke detector

GBP 397.16
1

Vesda Xtralis VIC-020 Multi-Fuctional Control Card VLF for VLF-250 amp VLF-500

Vesda Xtralis VIC-020 Multi-Fuctional Control Card VLF for VLF-250 amp VLF-500

Vesda Xtralis VIC-020 Multi-Functional Control Card VLF for VLF-250 VLF-500The VESDA VLF MCC Multi-function Control Card is an interface card for the range of Xtralis VESDA VLF smoke detectors. An MCC expands the range of input and output communications a VLF detector can perform.Why use a VLF MCCInstalling a VLF MCC into a VLF detector provides a cost-effective solution for customers who need enhanced connectivity fault detection and monitoring and annunciation of alarms and faults. The principal benefits includeImproved FACP connectivityThe VLF is fitted with two 2 alarm relays in its standard form. With an extra two 2 relays the Multi-function Control Card allows reporting of all four 4 alarm levels on dry relay outputs.Enhanced annunciationAn MPO Monitored 24 V Powered Output is available on the VIC-030 version of the card. The MPO provides power to devices such as sirens or strobes and monitors the line integrity.Enhanced control and fault detectionWith a VLF MCC installed a VLF has two 2 General Purpose Inputs GPIs allowing for example one GPI to report on loss of mains power and the other GPI to be used as a reset input. The VIC-030 version of the card has a self-configuring GPI depending on the jumper selection for MPORelay3.If MPO is selected activation of the GPI will disable the MPO.If Relay3 is selected the GPI will be set to External Fault e.g. for mains power supply monitoring.Key FeaturesProvides two 2 additional relaysProvides an extra General-Purpose Input GPI with line monitoringQuick and simple to installOut-of-the-box operation with minimal configuration required for extra featuresDiagnostic LEDs give visual indication of the cards statusFully compatible with Xtralis VESDA VLF smoke detector

GBP 246.11
1

Vesda Xtralis 059-007 Conical Sampling Point Kit

Vesda VRT-V00 Remote Mount Display for VLF cw Remote Termination Card amp 7 Relays

Vesda VRT-W00 Remote Mount Display for VLF cw Remote Termination Card amp No Relays

Vesda 020-052 19quot Enclosure for Sub-Rack 2 Rows

GBP 2037.12
1

Xtralis FLX-010 FAAST FLEX Single Pipe ASD Unit

Xtralis FLX-010 FAAST FLEX Single Pipe ASD Unit

Xtralis FLX-010 FAAST FLEX Single Pipe ASD UnitXtralis FAAST FLEX offers a highly flexible and cost-effective ASD solution for a wide range of applications such as small to medium warehouses cold storage elevator shafts ceiling and underfloor voids transformer and electrical rooms rest rooms and the like. FAAST FLEX provides consistent detection with minimum nuisance alarms to reduce operational costs enabled by improved detection chamber design.FAAST FLEX allows a high degree of flexibility through pre-engineered pipe network designs and true out-of-the-box operation with a built-in user-friendly configuration and control mechanism. It can be configured and commissioned using a 10-line dip-switch arrangement without the need for a special tool.Through its Bluetooth interface and associated smartphone applications FAAST FLEX offers extended configuration options and rapid diagnostics.FAAST FLEX is easy to install with reduced effort and time 1-man installation with an installation template different orientations direct wall-mounting and ample room for wiring. Through its modular design and field replaceable components FAAST FLEX allows convenient in-field service and maintenance thus minimizing downtime and reducing ongoing maintenance costs.How It WorksAir is drawn into the FAAST FLEX through a network of air sampling pipes by speed adjustable aspirator. Each pipe inlet has an airflow sensor that monitors airflow changes in the pipe. Inside the FAAST FLEX a sample of air is filtered and passed into the detection chamber and analysed for the presence of very small amounts of smoke. Air is exhausted from the FAAST FLEX and may be vented back into the protected zone.Key FeaturesReliable smoke detection for consistent performance and minimum nuisance alarmsSingle Dual channel variants with area coverage up to 1600m 17200 sq.ft for single channel and 2000m 21527 sq.ft for dual channelDouble knock capability Dual Channel for coincident detectionPipe length up to 270m 886 ft for single channel and 420m 1378 ft for dual channel allowing extended coverage and convenient detector mountingClass A B C performance allowing - 1 channel 5 15 32 holes respectively - 2 channels 8 28 56 holes respectivelyAn ultrasonic flow sensing element per chamber for accurate and reliable flow detectionA metallic mesh filter per chamber for optics protection and improved detector longevityAction Alarm and Fault relays per channel for connection to FACP and BMS systemsSimplified and intuitive LEDs user interface for immediate status indicationPre-engineered pipe networks for hassle-free and expedient design and installationTwo configuration modes - Out-of-box with built in user-friendly configuration and control mechanism for speedy commissioning - Extended for enhanced user experienceModular design with in-field replaceable chamber filter and aspirator for ease of service and maintenanceInstallation template different mounting orientations upright inverted and ample wiring room to save time and effortQuiet operation 30db with adjustable fan speed to suit various environmentsSuitable for cold storage environments with -40 C -40F operating temperatureBluetooth interface with mobile device App for extended configuration options and rapid diagnosticsGeneral Purpose Input GPI for remote Reset Disable External FaultPassword protected access for secured detector operation diagnostics and maintenanceIP40 rating for protection against ingress of foreign bodiesOnboard event log up to 2100 events for user actions and smoke trends

GBP 966.89
1

Xtralis FLX-020 FAAST FLEX Dual Pipe ASD Unit

Xtralis FLX-020 FAAST FLEX Dual Pipe ASD Unit

Xtralis FLX-020 FAAST FLEXDualPipe ASD UnitXtralis FAAST FLEX offers a highly flexible and cost-effective ASD solution for a wide range of applications such as small to medium warehouses cold storage elevator shafts ceiling and underfloor voids transformer and electrical rooms rest rooms and the like. FAAST FLEX provides consistent detection with minimum nuisance alarms to reduce operational costs enabled by improved detection chamber design.FAAST FLEX allows a high degree of flexibility through pre-engineered pipe network designs and true out-of-the-box operation with a built-in user-friendly configuration and control mechanism. It can be configured and commissioned using a 10-line dip-switch arrangement without the need for a special tool.Through its Bluetooth interface and associated smartphone applications FAAST FLEX offers extended configuration options and rapid diagnostics.FAAST FLEX is easy to install with reduced effort and time 1-man installation with an installation template different orientations direct wall-mounting and ample room for wiring. Through its modular design and field replaceable components FAAST FLEX allows convenient in-field service and maintenance thus minimizing downtime and reducing ongoing maintenance costs.How It WorksAir is drawn into the FAAST FLEX through a network of air sampling pipes by speed adjustable aspirator. Each pipe inlet has an airflow sensor that monitors airflow changes in the pipe. Inside the FAAST FLEX a sample of air is filtered and passed into the detection chamber and analysed for the presence of very small amounts of smoke. Air is exhausted from the FAAST FLEX and may be vented back into the protected zone.Key FeaturesReliable smoke detection for consistent performance and minimum nuisance alarmsSingle Dual channel variants with area coverage up to 1600m 17200 sq.ft for single channel and 2000m 21527 sq.ft for dual channelDouble knock capability Dual Channel for coincident detectionPipe length up to 270m 886 ft for single channel and 420m 1378 ft for dual channel allowing extended coverage and convenient detector mountingClass A B C performance allowing - 1 channel 5 15 32 holes respectively - 2 channels 8 28 56 holes respectivelyAn ultrasonic flow sensing element per chamber for accurate and reliable flow detectionA metallic mesh filter per chamber for optics protection and improved detector longevityAction Alarm and Fault relays per channel for connection to FACP and BMS systemsSimplified and intuitive LEDs user interface for immediate status indicationPre-engineered pipe networks for hassle-free and expedient design and installationTwo configuration modes - Out-of-box with built in user-friendly configuration and control mechanism for speedy commissioning - Extended for enhanced user experienceModular design with in-field replaceable chamber filter and aspirator for ease of service and maintenanceInstallation template different mounting orientations upright inverted and ample wiring room to save time and effortQuiet operation 30db with adjustable fan speed to suit various environmentsSuitable for cold storage environments with -40 C -40F operating temperatureBluetooth interface with mobile device App for extended configuration options and rapid diagnosticsGeneral Purpose Input GPI for remote Reset Disable External FaultPassword protected access for secured detector operation diagnostics and maintenanceIP40 rating for protection against ingress of foreign bodiesOnboard event log up to 2100 events for user actions and smoke trends

GBP 1237.62
1

Vesda VRT-100 Remote Mount Programmer

Vesda VRT-100 Remote Mount Programmer

Vesda VRT-100 Remote Mount ProgrammerThe Programmer Module allows direct access to all VESDAnet devices on an VESDA smoke detection system. It allows configuration and status reporting of detectors displays and interfaces and is required when installing commissioning and maintaining a VESDA network. By incorporating a user friendly menu navigation through the comprehensive features of VESDAnet is convenient and simple.The programmer module is available as a hand-held device with included DB15 serial cable or can be mounted into a VESDA VLP or VESDA VLS detector a remote mounting box or a 19 inch sub rack. The two rows of large push buttons enable the user to log ON and navigate through the menu trees to the various command and parameter setting functions. The top row of keys are called Soft Keys and are assigned programming options appropriate to the screen being viewed.Some of the parameters that can be accessed via the programmer include device status reporting zone number and name allocation flow normalisation alarm threshold setting day night weekend initiation of AutoLearn wiring order relay testing and event log review. Up to 14 assigned Users or Administrators with an individual 4 digit Personal Identification Number PIN and one Distributor can log onto a VESDAnet system under one of three levels of access which are password protectedUser USR is only able to view parameters check status alarms and reset the system.Administrator ADM has access to most commands and programming parameters.Distributor DST is the topmost level and has unlimited access to all commands and parameters in the system.Lost PIN numbers can be overcome by obtaining a once only pass number from your Xtralis VESDA dealer.The programmer automatically logs OFF when not in use for more than 10 minutes. The user is prompted with a beeping sound at 1 minute and at 15 seconds before log OFF. Any key may be pressed to cancel the automatic log OFF process.Key FeaturesUser friendly menu systemSupports multiple languagesSingle point access to entire VESDAnet systemAlarm and fault simulationShows wiring orderLocates communications failuresPassword securityHand held or remote mountingAutomatic Logoff when inactiveBacklit LCD screen

GBP 955.28