293 results (0,17660 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Vesda VHX-0300 PC Link HLI Peer To Peer Complete with Leads Open Protocol

Vesda VHX-1300 Metal Box HLI Peer to Peer

Vesda VHX-1300 Metal Box HLI Peer to Peer

Vesda VHX-1300 Metal Box HLI Peer to PeerThe VESDA Wall-Mounted Open Protocol High Level Interface HLI links your VESDAnet with PC software monitoring tools Building Management Systems BMSs and Fire Alarm Control Panels FACPs otherwise known as host. With a built-in VESDAnet interface you dont need a remote VESDAnet socket module which makes the Wall-mounted HLI a cost-effective solution to your interface requirements. There are two models available depending on whether you require communication between your host and VESDAnet to be master-slave or peer-to-peer.In the peer-to-peer model the host polls the HLI for information about devices on VESDAnet while the HLI sends unsolicited messages to the host. In this way both the HLI and host are responsible for supervising the communications link between them. In the peer-to-peer model the host can request and receive multiple messages from the HLI.A VESDA High Level Interface HLI enables connection between a VESDAnet and configuration and monitoring platforms. Two main models are available1 Sliding Windows HLI which enables communication between a VESDAnet and configuration and monitoring software packages Xtralis VSC and Xtralis VSM42 Open Protocol HLI which integrates a VESDAnet to third-party software packages building management systems BMSs and fire alarm control panels FACPs.These HLIs are available in a plastic portable housing which can be used in multiple sites and a fixed wall-mounted configuration to provide a permanent connection in a convenient location at one site.Key FeaturesDirect access and monitoring of your entire VESDAnet systemSeamless data transferEasily configured using Xtralis configuring and monitoring software packages.Information available using the Open Protocol HLIDetector Type VLC VLS VLP VLF.Alarm status Alert Action Fire1 Fire2.Fault Status System Zone Urgent Power Network Flow Filter.Status Isolated Normalizing AutoLearn Scanning.Display info Alarm thresholds Location name.Display update Smoke level Alarm Fault status.Fault details list of active fault codes.Fault strings ASCII strings to describe each fault code.Detector controls Reset Isolate Silence Test Scan or Normalize2 .Configuration of Day Night alarm thresholds2

GBP 2443.61
1

Vesda Xtralis VLI-885 LaserINDUSTRIAL Detector with Relays VESDAnet and Ethernet

Vesda Xtralis VLI-885 LaserINDUSTRIAL Detector with Relays VESDAnet and Ethernet

Vesda Xtralis VLI-885 LaserINDUSTRIAL Detector with Relays VESDAnet and EthernetThe VESDA VLI by Xtralis is an industry first early warning aspirating smoke detection ASD system designed to protect industrial applications and harsh environments of up to 2000m2 20000 sq. ft..The VLI detector combines a fail-safe Intelligent Filter patent pending with an advanced clean-air barrier for optics protection allowing the use of absolute detection and a long detection chamber life without the need for recalibration.The Intelligent Filtereffectively reduces the level of pollution in the air sample before it enters the detection chamber which dramatically extends the operational life of the detector in harsh and polluted environments.is fully monitored therefore providing consistent sensitivity over the entire operational life of the detector.The VLI detector features a robust IP54-rated enclosure which provides protection against dust ingress and water splash. In the majority of applications this eliminates the need to use expensive external IP enclosures thus simplifying and reducing the cost of installation. The VLI detector is equipped with a powerful aspirator that provides a total pipe length of 360m 1200 ft. It is fully supported by the Xtralis ASPIRE2 VSC and VSM4 software applications which facilitate ease of pipe network design system commissioning and maintenance together with compatibility with existing VESDA installations.The AutoLearn commissioning assistant reduces setup time and ensures optimum alarm and flow thresholds in a range of environments. The VLI detector features a standardised industry BACnet over Ethernet communication protocol for remote monitoring and programming and connection to building management systems BMS and automation devices. This translates to direct cost savings on integration and monitoring. The VLI detector is inherently less prone to nuisance alarms due to the intelligent filter lint trap sub-sampling probe and secondary filter. Coupled with its modular design VLI offers a lower total cost of ownership over the life of the product.Key FeaturesSuitable for Class 1 Division 2 applications - Groups ABC DUp to 2000m2 20000 sq. ft. coverageUp to 4 inlet pipesTotal pipe length up to 360m 1200 ftFive 5 high intensity status LEDs for greater visibilityRobust absolute smoke detectionIntelligent Filter patent pendingLint Trap to capture fibrous particulatesSub-sampling Probe inertial separatorSecondary FilterClean air barrier for optics protectionReferencingAutoLearn Smoke and FlowClean Air ZeroAir-path monitoringFive 5 relays Fire Fault and 3 configurableRelays configurable as latching or nonlatchingExpandable GPI and relaysUltrasonic flow sensingXtralis VSC Xtralis VSM4 and ASPIRE2 software supportIP54 EnclosureEasy mounting through steel support bracketModular field replaceable parts for ease of servicingBACnet over EthernetLocal USB configuration portEasy cable termination accessImperial and metric pipe portsRubberized finish to external housing

GBP 6726.62
1

Vesda VHX-0310 PC Link HLI Open Protocol Master Slave

Vesda VHX-0310 PC Link HLI Open Protocol Master Slave

Vesda VHX-0310 PC Link HLI Open Protocol Master SlaveA VESDA High Level Interface HLI enables connection between a VESDAnet and configuration and monitoring platforms. Two main models are available1 Sliding Windows HLI which enables communication between a VESDAnet and configuration and monitoring software packages Xtralis VSC and Xtralis VSM4 and2 Open Protocol HLI which integrates a VESDAnet to third-party software packages building management systems BMSs and fire alarm control panels FACPs.These HLIs are available in a plastic portable housing which can be used in multiple sites and a fixed wall-mounted configuration to provide a permanent connection in a convenient location at one site.In the master-slave model the host supervises the communications link between itself and the HLI slave by regularly polling the HLI to determine whether there has been a change in the status of a detector on VESDAnet. In response to polling by the host the HLI generates a single response which is sent back to the host.In this way no unsolicited messages are sent from the HLI to the host. Depending on the polling strategy adopted the Master Slave Open Protocol HLI can report any and all fire alarms within a few seconds of a detector going into alarm. Exact performance is dependent on the polling strategy adopted.Key FeaturesDirect access and monitoring of VESDAnet systemSeamless data transferEasily configured using Xtralis configuring and monitoring software packagesInformation AvailableDetector Type VLC VLS VLP VLF.Alarm status Alert Action Fire1 Fire2.Fault Status System Zone Urgent Power Network Flow Filter.Status Isolated Normalizing AutoLearn Scanning.Display info Alarm thresholds Location name.Display update Smoke level Alarm Fault status.Fault details list of active fault codes.Fault strings ASCII strings to describe each fault code.Detector controls Reset Isolate Silence Test Scan or Normalize2.Configuration of Day Night alarm thresholds2

GBP 1292.38
1

Vesda Xtralis M6 Nut - Pack Of 100 PIP-028

Vesda Xtralis KA-1 Steam Trap

Vesda VHX-1410 Metal Box HLI Modbus Type 2

Vesda VHX-1400 Metal Box HLI Modbus Type 1

Vesda WHTUN-10 Socket Union Pack of 10 Equivalent to PIP-003-W

Vesda VHX-0420 PC Link HLI Modbus MK3

Vesda VHX-0420 PC Link HLI Modbus MK3

Vesda VHX-0420 PC Link HLI Modbus MK3The VESDA Modbus Type 3 High Level Interface HLI integrates VESDAnet network with host monitoring platforms such as Building Management Systems BMSs and Fire Alarm Control Panels FACPs. The Modbus Type 3 HLI acts as a proxy for all VESDA devices on the VESDAnet network providing access to the rich status information that is available from VESDA detectors as well as the ability to control and configure these devices.Alarms are reported to the host within a few seconds of a detector reaching an alarm condition. Exact performance is dependent on the polling strategy and size of the monitored network. The Modbus Type 3 HLI is able to support up to 100 VESDA detectors on a single VESDAnet network. A standard unit used to provide a flexible solution where permanent mounting is not required. In this case a VESDAnet socket interface is required to connect the HLI onto the VESDAnet network.A VESDA High Level Interface HLI enables connection between a VESDAnet and configuration and monitoring platforms. Two main models are available1 Sliding Windows HLI which enables communication between a VESDAnet and configuration and monitoring software packages Xtralis VSC and Xtralis VSM4 and2 Open Protocol HLI which integrates a VESDAnet to third-party software packages building management systems BMSs and fire alarm control panels FACPs.These HLIs are available in a plastic portable housing which can be used in multiple sites and a fixed wall-mounted configuration to provide a permanent connection in a convenient location at one site.Key FeaturesDirect access and monitoring of your entire VESDAnet systemSeamless data transferEasily configured using Xtralis configuring and monitoring software packagesProtocol SupportsVESDA VLP VLS VLC VLF VLI and VFT-15 detectorsVESDA-E VEP VEU and VEA detectorsAlarm StatusFault StatusSmoke LevelDetailed Fault InformationAlarm ThresholdsDetector Control including Reset Disable Silence Alarm Test and NormaliseOperational Status for processes such as Normalisation and AutoLearn

GBP 1304.62
1

Vesda Xtralis PIP-003 25mm Socket Union Pack of 10

Vesda VHX-0410 Modbus HLI for Darwish amp Honeywell Only

Vesda VHX-0410 Modbus HLI for Darwish amp Honeywell Only

Vesda VHX-0410 Modbus HLI for Darwish Honeywell OnlyThe VESDA ModBus High Level Interface HLI links your VESDAnet with PC software monitoring tools Building Management Systems BMSs or Fire Alarm Control Panels FACPs otherwise known as host that support the ModBus protocol. There are two models availableModBus HLI Type 1 VHX-0400 which echoes each character received on the RS232 link back to the host together with reply message.ModBus HLI Type 2 VHX-0410 which has the echoing function disabled.Key FeaturesDirect access and monitoring of your VESDAnet system.Seamless data transfer.Easily configured using Xtralis configuring and monitoring software packages.DescriptionOne ModBus HLI is used to interface to a VESDAnet. Modbus HLI supports up to a maximum of 40 VESDA detectors on a VESDAnet.The Modbus HLI supports VESDAnet detector zone numbers between 1 to 200. The Modbus HLI divides up the address range into to 7 logical networks. For example the first 30 addresses are considered in network 1 addresses between 31 to 60 are in network 2 and so on.Smoke and Alarm LevelsThe Smoke Level is reported relative to the Fire Alarm threshold where the full scale is 20. For example if the Fire Alarm threshold is 0.5 obsm a level of 0.1obsm is reported as 4. In other words the Actual Smoke level Reported smoke value Fire1 Threshold 20.FaultsAll VESDAnet faults are mapped on one or more of the Modbus HLI faults which are listed belowHead FaultHead Fault Battery and MainsHead Fault Scanner2 and Flow FaultVESDAnet faults categorised as network faults are mapped onto all zones whereas zone faults are mapped onto that particular zone.

GBP 1328.53
1

Vesda VHX-1310 Metal Box HLI Master Slave

Vesda VHX-1310 Metal Box HLI Master Slave

Vesda VHX-1310 Metal Box HLI Master SlaveThe VESDA Wall-Mounted Open Protocol High Level Interface HLI links your VESDAnet1 with PC software monitoring tools Building Management Systems BMSs and Fire Alarm Control Panels FACPs otherwise known as host. With a built-in VESDAnet interface you dont need a remote VESDAnet socket module which makes the Wall-mounted HLI a cost-effective solution to your interface requirements. There are two models available depending on whether you require communication between your host and VESDAnet to be master-slave or peer-to-peer.In the master-slave model the host supervises the communications link between itself and the HLI slave by regularly polling the HLI to determine whether there has been a change in the status of a detector on VESDAnet. In response to polling by the host the HLI generates a single response which is sent back to the host. In this way no unsolicited messages are sent from the HLI to the host. Depending on the polling strategy adopted the Master Slave Open Protocol HLI is able to report any and all fire alarms within a few seconds of a detector going into alarm. Exact performance is dependent on the polling strategy adopted.Key FeaturesDirect access and monitoring of your entire VESDAnet systemSeamless data transferEasily configured using Xtralis configuring and monitoring software packages.Information available using the Open Protocol HLIDetector Type VLC VLS VLP VLF.Alarm status Alert Action Fire1 Fire2.Fault Status System Zone Urgent Power Network Flow Filter.Status Isolated Normalizing AutoLearn Scanning.Display info Alarm thresholds Location name.Display update Smoke level Alarm Fault status.Fault details list of active fault codes.Fault strings ASCII strings to describe each fault code.Detector controls Reset Isolate Silence Test Scan or Normalize2 .Configuration of Day Night alarm thresholds2

GBP 2333.39
1

Vesda Xtralis PIP-012 250ml Solvent Cement

Vesda Xtralis PIP-012 250ml Solvent Cement

Vesda Xtralis 250ml Solvent CementSolvent cement welding is a simple and quick means of constructing high integrity leak free joints. Care must be used to ensure that the correct solvent cement is used and that joining instructions are followed properly.This specially formulated solvent cement is used with ABS pipe and fittings to join the surfaces together. The solvent cement melts the two surfaces to form a chemical weld when applied correctly between the fittings.Key FeaturesSolvent cement for ABSContains 250mlProduct InformationSeparate COSHH statement availableIntended usage Jointing of pipeworkPacking 0.25 litre cans Acorn FireConstituents ABS resin dispersed in MethylEthyl KetoneShelf life 12 months minimumPhysical Product DataBoiling Point 80CVapour pressure 100mm Mercury at 25CVapour density 1.18 at 20C 2.4 at boilingpointSpecific gravity 0.86Solubility in Water MiscibleAppearance Grey opaque fluid Strong odourBefore Applying Solvent CementBe aware at all times of good safety practicesSolvent cements are flammableEliminate all ignition sourcesDo not smoke during use and do not expose to other sources of heat or flame in working or storage areasAvoid breathing vaporsUse only with adequate ventilationExplosion proof mechanical ventilation or local exhaust is recommended to maintain vapor concentrations below recommended exposure limitsIn confined areas a NIOSH approved organic vapor cartridge respirator with full-face piece is recommendedCement should be stored in the shade at temperatures between 40F and 110F Acorn FireContainers should be kept tightly closed when not in use and covered as much as possible during useAvoid contact with eyes.Splash proof chemical goggles are recommendedAvoid frequent contact with skinWearing PVA coated gloves and an impervious apron are recommendedSolvent cements have a limited shelf life and must be used prior to the expiration dateRefer to printed warnings on cement can and Material Safety Datasheets for additional informationWARNINGSolvent cement and cleanersARE HAZARDOUSFLAMMABLE MATERIALS. Do not joint nearnaked names and avoid smoking in the working area.Do not use cements or cleaners in confined spaces.Concentrated vapours may cause dizziness.Please Note The PIP-012 is equivalent to the REDCEM.

GBP 14.63
1

Vesda VIC-010 VESDAnet Card for VLF-250 amp VLF-500

Vesda Xtralis OSID Emitter Wired 24Vdc OSE-SPW

Vesda Xtralis OSID Emitter Wired 24Vdc OSE-SPW

Xtralis OSID Emitter Wired 24Vdc OSE-SPWThe OSE-SPW is used as a preferred solution when 24 Vdc is close by.The company that revolutionized very early warning smoke detection with VESDA has reinvented smoke detection for open spaces with Open-area Smoke Imaging Detection OSID. OSID by Xtralis provides reliable cost-effective smoke detection for open spaces where fire detection presents unique challenges and where very early warning is not always the priority.In its simplest configuration OSID by Xtralis uses one imager a camera-like device with a wide field of view and a wired or battery-powered emitter roughly aligned on the opposite wall within the protected area. The emitter sends both infrared and ultraviolet coded light signals to the imager. If the light reception is altered due to the presence of genuine smoke particles the imager will go into alarm. The novel use of dual light frequencies in an open-path device enables OSID to discriminate between real smoke and other objects including insects steam condensation and dust thus drastically reducing false alarms.Key FeaturesOSIDs uncompromising performance is based on the patented use of digital imaging dual-frequency beams and smart algorithms deliveringPatented dual wavelength UV IR particle detectionCMOS Imager with wide viewing anglesSimple installation commissioning and maintenanceHigh tolerance to vibration and structural movementHightolerance to dust fogging steam reflections and object intrusionHigh resistance to reflected sunlightOn-board log memorySoftware tool for diagnostic purposesAesthetically discreet and 3D coverageLong range up to 150 m. 492 ft. with minimal free space 15 cm.5.85ApplicationsOSID is ideal for use in a wide range of industries and applications. These include atriums domes and large rooms inAirportsTrain stationsShopping centresStadiumsEducational facilitiesHotels convention centres and office buildingscomplexesEntertainment venuesWarehouses and production floors

GBP 326.59
1

Vesda Xtralis OSI-90 Open-area Smoke Imaging Detector - 80 Coverage

Vesda Xtralis OSI-90 Open-area Smoke Imaging Detector - 80 Coverage

Vesda Xtralis OSI-90 Open-area Smoke Imaging Detector - 80 CoverageThe OSI-90 covers a distance of 30 - 150m with the OSE-SPW. This configuration is for a 1 on 1 system and is not suitable to work with high powered emitters.The company that revolutionized very early warning smoke detection with VESDA has reinvented smoke detection for open spaces with Open-area Smoke Imaging Detection OSID. OSID by Xtralis provides reliable cost-effective smoke detection for open spaces where fire detection presents unique challenges and where very early warning is not always the priority.In its simplest configuration OSID by Xtralis uses one imager a camera-like device with a wide field of view and a wired or battery-powered emitter roughly aligned on the opposite wall within the protected area. The emitter sends both infrared and ultraviolet coded light signals to the imager. If the light reception is altered due to the presence of genuine smoke particles the imager will go into alarm. The novel use of dual light frequencies in an open-path device enables OSID to discriminate between real smoke and other objects including insects steam condensation and dust thus drastically reducing false alarms.Key FeaturesOSIDs uncompromising performance is based on the patented use of digital imaging dual-frequency beams and smart algorithms deliveringPatented dual wavelength UV IR particle detectionCMOS Imager with wide viewing anglesSimple installation commissioning and maintenanceHigh tolerance to vibration and structural movementHightolerance to dust fogging steam reflections and object intrusionHigh resistance to reflected sunlightOn-board log memorySoftware tool for diagnostic purposesAesthetically discreet and 3D coverageLong range up to 150 m. 492 ft. with minimal free space 15 cm.5.85ApplicationsOSID is ideal for use in a wide range of industries and applications. These include atriums domes and large rooms inAirportsTrain stationsShopping centresStadiumsEducational facilitiesHotels convention centres and office buildingscomplexesEntertainment venuesWarehouses and production floorsThe OSI-90 Imager is used in multi emitter applications or in shorter distance applications. The appropriate number of OSE-SP-01 OSE-SPW or OSE-HPW Emitters must be paired with the Imager to a maximum of seven.

GBP 691.74
1

Vesda Xtralis OSE-SP-01 OSID-DE Emitter Alkaline Battery

Vesda Xtralis OSE-SP-01 OSID-DE Emitter Alkaline Battery

Vesda Xtralis OSE-SP-01 OSID-DE Emitter Alkaline BatteryEach emitter up to 7 generates 2 light beams in the UV and IR frequencies. These bundles are also encoded through a unique code recognized by the receiver. This approach allows the receiver to ignore any UV and IR light beams that come from sources other than emitters the typical interference problems generated by sunlight are thus overcome.Battery powered emitters last for 3 years.Emitter Size 208 mm x 136 mm x 96 mm. Certificate 3052011 EU - CPR.Open-area Smoke Imaging Detection OSID by Xtralis is a new innovation in projected beam smoke detection technology. By using advanced dual wavelength projected beams and optical imaging technology for early warning smoke detection OSID provides a cost-effective reliable and easy-to-install solution that overcomes typical beam detection issues such as false alarm incidents and alignment difficulties.In its simplest configuration OSID by Xtralis uses one imager a camera-like device with a wide field of view and a wired or battery-powered emitter roughly aligned on the opposite wall within the protected area. The emitter sends both infrared and ultraviolet coded light signals to the imager. If the light reception is altered due to the presence of genuine smoke particles the imager will go into alarm. The novel use of dual light frequencies in an open-path device enables OSID to discriminate between real smoke and other objects including insects steam condensation and dust thus drastically reducing false alarms.Key FeaturesPatented dual wavelength UV IR particle detectionCMOS imager with wide viewing anglesSimple installation commissioning and maintenanceHigh tolerance to vibration and structural movementHigh resistance to dust fogging steam reflections and object intrusionHigh resistance to reflected sunlightOn-board log memorySoftware tool for diagnostic purposesAesthetically discreet and 3D coverageLong range up to 150 m 492 ft. with minimal free space dia. 15 cm 5.85 inchApplicationsOSID is ideal for use in a wide range of industries and applications. These include atriums domes and large rooms inAirportsTrain stationsShopping centresStadiumsEducational facilitiesHotels convention centres and office buildingscomplexesEntertainment venuesWarehouses and production floors

GBP 326.59
1

Vesda-E VES VES-A00-P Aspirating Smoke Detector with LEDs

Vesda-E VES VES-A00-P Aspirating Smoke Detector with LEDs

Vesda-E VES VES-A00-P Aspirating Smoke Detector with LEDsThe VESDA-E VES can identify and monitor smoke density by individual sampling pipe sector which allows a single zone to be divided into four separate sectors for example distinguishing between separate aisles within a data room. Sector addressability enables the user to respond to a potential fire event quickly by reducing the search area. The VESDA-E VES has four programable alarm thresholds Alert Action Fire 1 and Fire 2 per pipe that allows flexible field application. After the detector identifies the first sector to reach the Alert threshold it continues to sample from all sectors to report real time status per sector via the intuitive touch screen display. Built on the Flair detection technology and years of application experience the VESDA-E VES detector delivers very early warning with the best in class dust rejection throughout its lifetime.The VESDA-E is the most advanced reliable and flexible ASD system ever produced.Key FeaturesSector addressability for up to four sectors or zonesAdaptive scan thresholdFlair detection technology delivers reliable very early warning in a wide range of environments with minimal nuisance alarmsMulti stage filtration and optical protection with clean air barriers ensures lifetime detection performanceFour configurable alarm levels per sector and a wide sensitivity range deliver optimum protection for the widest range of applicationsIntuitive LCD display provides instant status information for immediate responseFlow fault thresholds per port accommodate varying airflow conditionsSmart on-board filter retains dust count and remaining filter life for predictable maintenanceExtensive event log 20000 events for event analysis and system diagnosticsAuto Learn smoke and flow for reliable and rapid commissioningBackward compatible with VLS and VESDAnetEthernet for connectivity with Xtralis software for configuration secondary monitoring and maintenanceSecondary monitoring and maintenance via WiFiUSB for PC configuration and firmware upgrade using a memory stickTwo programmable GPIs 1 monitored for flexible remote controlField replaceable sub-assemblies enable faster service and maximum uptime

GBP 4964.20
1

Vesda-E VES VES-A10-P Aspirating Smoke Detector with 3.5 Display

Vesda-E VES VES-A10-P Aspirating Smoke Detector with 3.5 Display

Vesda-E VES VES-A10-P Aspirating Smoke Detector with 3.5 DisplayThe VESDA-E VES can identify and monitor smoke density by individual sampling pipe sector which allows a single zone to be divided into four separate sectors for example distinguishing between separate aisles within a data room. Sector addressability enables the user to respond to a potential fire event quickly by reducing the search area. The VESDA-E VES has four programable alarm thresholds Alert Action Fire 1 and Fire 2 per pipe that allows flexible field application. After the detector identifies the first sector to reach the Alert threshold it continues to sample from all sectors to report real time status per sector via the intuitive touch screen display. Built on the Flair detection technology and years of application experience the VESDA-E VES detector delivers very early warning with the best in class dust rejection throughout its lifetime.The VESDA-E is the most advanced reliable and flexible ASD system ever produced.Key FeaturesSector addressability for up to four sectors or zonesAdaptive scan thresholdFlair detection technology delivers reliable very early warning in a wide range of environments with minimal nuisance alarmsMulti stage filtration and optical protection with clean air barriers ensures lifetime detection performanceFour configurable alarm levels per sector and a wide sensitivity range deliver optimum protection for the widest range of applicationsIntuitive LCD display provides instant status information for immediate responseFlow fault thresholds per port accommodate varying airflow conditionsSmart on-board filter retains dust count and remaining filter life for predictable maintenanceExtensive event log 20000 events for event analysis and system diagnosticsAuto Learn smoke and flow for reliable and rapid commissioningBackward compatible with VLS and VESDAnetEthernet for connectivity with Xtralis software for configuration secondary monitoring and maintenanceSecondary monitoring and maintenance via WiFiUSB for PC configuration and firmware upgrade using a memory stickTwo programmable GPIs 1 monitored for flexible remote controlField replaceable sub-assemblies enable faster service and maximum uptime

GBP 5292.54
1

Vesda Xtralis VKT-855 VESDA-E VES Demonstration Kit

Vesda Xtralis VKT-855 VESDA-E VES Demonstration Kit

Vesda Xtralis VKT-855 VESDA-E VES Demonstration KitThe VESDA-E VES is similar to the flagship VESDA-E VEP aspirating smoke detector but also includes a valve mechanism in the inlet manifold and software to control the airflow from the four Sectors pipes. This configuration enables a single zone to be divided into four separate sectors for example distinguishing between separate aisles within a data room.The VES enables the user to locate the source of smoke by identifying the first sector to reach the Alert level. The detector then continues to sample from all sectors to monitor fire growth and will report separate alarm levels for each sector.The VES provides four individually configurable alarm levels Alert Action Fire 1 and Fire 2 for each sector allowing optimum protection in a wide range of applications. Built on the Flair detection technology and years of application experience VES detectors achieve consistent performance over their lifetime via absolute calibration. In addition the VES delivers a range of revolutionary features that provide user value.How it WorksThe VES draws air from all sectors in use. If the smoke level reaches the Adaptive Scan Threshold the VES quickly scans each sector to identify which sector is carrying smoke. The first sector to reach the Alert level is designated as the First Alarm Sector FAS and this sector is signalled to the user. If two or more sectors reach the Alert level then the sector with the highest smoke concentration is designated as the First Alarm Sector FAS. Once Fast Scan is completed and the FAS identified the VES continues to closely monitor all four sectors to track fire growth and maintain full protection of the area.Key FeaturesSector addressability for up to four sectorsAdaptive scan thresholdFlair detection technology delivers reliable very early warning in a wide range of environments with minimal nuisance alarmsMulti stage filtration and optical protection with clean air barriers ensures lifetime detection performanceFour configurable alarm levels per sector and a wide sensitivity range deliver optimum protection for the widest range of applicationsIntuitive LCD display provides instant status information for immediate responseFlow fault thresholds per port accommodate varying airflow conditionsSmart on-board filter retains dust count and remaining filter life for predictable maintenanceExtensive event log 20000 events for event analysis and system diagnosticsAutoLearn smoke and flow for reliable and rapid commissioningBackward compatible with VLS and VESDAnetEthernet for connectivity with Xtralis software for configuration secondary monitoring and maintenanceSecondary monitoring and maintenance via WiFiUSB for PC configuration and firmware upgrade using a memory stickTwo programmable GPIs 1 monitored for flexible remote controlField replaceable sub-assemblies enable faster service and maximum uptime

GBP 6136.43
1

Vesda Xtralis OSI-10 Open-area Smoke Imaging Detector - 7 Coverage

Vesda Xtralis OSI-10 Open-area Smoke Imaging Detector - 7 Coverage

Vesda Xtralis OSI-10 Open-area Smoke Imaging Detector - 7 CoverageThe OSI-10 covers a distance of 30 - 150m with the OSE-SPW. This configuration is for a 1 on 1 system and is not suitable to work with high powered emitters.The company that revolutionized very early warning smoke detection with VESDA has reinvented smoke detection for open spaces with Open-area Smoke Imaging Detection OSID. OSID by Xtralis provides reliable cost-effective smoke detection for open spaces where fire detection presents unique challenges and where very early warning is not always the priority.In its simplest configuration OSID by Xtralis uses one imager a camera-like device with a wide field of view and a wired or battery-powered emitter roughly aligned on the opposite wall within the protected area. The emitter sends both infrared and ultraviolet coded light signals to the imager. If the light reception is altered due to the presence of genuine smoke particles the imager will go into alarm. The novel use of dual light frequencies in an open-path device enables OSID to discriminate between real smoke and other objects including insects steam condensation and dust thus drastically reducing false alarms.3D Volumetric CoverageA significant benefit of OSID is its ability to provide volumetric coverage. As many as seven emitters can be placed within the field of view of a single imager each placed at different heights. The OSID imagers large viewing angles both horizontal and vertical enable three-dimensional area coverage for design flexibility and additional deployment savings. Unlike other volumetric technologies OSID delivers absolute calibration for consistent detection performance regardless of lighting conditions smoke colour airflows or other environmental conditions.Key FeaturesOSIDs uncompromising performance is based on the patented use of digital imaging dual-frequency beams and smart algorithms deliveringPatented dual wavelength UV IR particle detectionCMOS Imager with wide viewing anglesSimple installation commissioning and maintenanceHigh tolerance to vibration and structural movementHightolerance to dust fogging steam reflections and object intrusionHigh resistance to reflected sunlightOn-board log memorySoftware tool for diagnostic purposesAesthetically discreet and 3D coverageLong range up to 150 m. 492 ft. with minimal free space 15 cm.5.85ApplicationsOSID is ideal for use in a wide range of industries and applications. These include atriums domes and large rooms inAirportsTrain stationsShopping centresStadiumsEducational facilitiesHotels convention centres and office buildingscomplexesEntertainment venuesWarehouses and production floorsThe OSI-10 Imager must be paired with either the OSE-SP-01 or OSE-SPW Standard Power Emitter. The OSI-10 can only support one emitter.

GBP 671.33
1

Xtralis OSID-EHE OSID Emitter Environmental Housing