82 results (0,13968 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Vesda Xtralis VRT-T00 VLI Remote Mount Display without Relays

Vesda VRT-V00 Remote Mount Display for VLF cw Remote Termination Card amp 7 Relays

Vesda VRT-W00 Remote Mount Display for VLF cw Remote Termination Card amp No Relays

Vesda VRT-700 Remote Mount Display for VLS with Remote Termination Card No Relays

Vesda VRT-700 Remote Mount Display for VLS with Remote Termination Card No Relays

Vesda VRT-700 Remote Mount Display for VLS with Remote Termination Card No RelaysThe VRT-700 is a Remote Display Module with Remote Termination Card which has been designed for use with the LaserSCANNER range.Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display a 2 digit numeric display an audible sounder clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.The Display Module can be mounted into a detector unit a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations. There are various versions of the display module depending on the type of detector and the relay configuration required. The LaserSCANNER display has a fourth mode for the Numerical Display which shows the First Alarm SectorFAS this being the number of the sector pipe that has detected smoke. For the LaserCOMPACT the Fire 2 LED is omitted. Smoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 120 of the Fire 1 smoke threshold level. To the left of the bar graph are the Fire 1 Action and Alert smoke threshold indicators. At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to triggering the next level of alarm.High intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition. Similarly any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information. The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified rectified and the system reset.Four large tactile push button keys enable users to reset isolate or silence the detector and control the mode of the display module. The buttons can be disabled to prevent operation of its functions. A lamp test routine is initiated by pressing the Mode key for two seconds. A Manual Scan can be initiated on the LaserSCANNER by holding the Silence button for 2 seconds.Key FeaturesProvides Immediate Status Reporting for a Single VESDA Zone.Allows Zone Control of Assigned VESDA Detector.High Intensity Alarm LEDs.Remote Relay Option.20-Segment Vertical Bar Graph Display.Alarm Threshold Indicators.Built-In Sounder for Audible Warning.Comprehensive Fault Reporting.Multi-mode Numeric Display defaults to smoke obscuration.Recessed Mounting Option.

GBP 899.88
1

Vesda Xtralis VRT-Q00 VESDA Remote Mount Display for VLI with Remote Termination Card 7 Relays

Vesda Xtralis VRT-Q00 VESDA Remote Mount Display for VLI with Remote Termination Card 7 Relays

Vesda Xtralis VRT-Q00 VESDA Remote Mount Display for VLI with Remote Termination Card 7 RelaysDisplay modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display a 2-digit numeric display an audible sounder clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.The Display Module can be mounted into a detector unit a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations.There are various versions of the display module depending on the type of detector and the relay configuration required.Smoke IndicationSmoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 120 of the Fire 1 smoke threshold level.To the left of the bar graph are the Fire 1 Action and Alert smoke threshold indicators. At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to triggering the next level of alarm.Status LightsHigh intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition.Similarly any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information. The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified rectified and the system reset.Numeric DisplayA 2 digit numerical readout has a number of modes that are indicated by up to four LEDs The current smoke level in obscurationm obscurationft Fire 1 threshold in obscurationm obscurationft. This is the sensitivity of the detectorKey Features Provides Immediate Status Reporting for a Single VESDA Zone Allows Zone Control of Assigned VESDA Detector High Intensity Alarm LEDs Remote Relay Option 20-Segment Vertical Bar Graph Display Alarm Threshold Indicators Built-In Sounder for Audible Warning Comprehensive Fault Reporting Multi-mode Numeric Display defaults to smoke obscuration Recessed Mounting Option

GBP 1014.77
1

Vesda VRT-K00 Remote Mount Display for VLC with Remote Termination Card No Relays

Vesda VRT-K00 Remote Mount Display for VLC with Remote Termination Card No Relays

Vesda VRT-K00 Remote Mount Display for VLC with Remote Termination Card No RelaysThe VRT-K00 is a Remote Display Module designed for use with the LaserCOMPACT range.Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display a 2 digit numeric display an audible sounder clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.The Display Module can be mounted into a detector unit a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations. There are various versions of the display module depending on the type of detector and the relay configuration required. The LaserSCANNER display has a fourth mode for the Numerical Display which shows the First Alarm SectorFAS this being the number of the sector pipe that has detected smoke. For the LaserCOMPACT the Fire 2 LED is omitted. Smoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 120 of the Fire 1 smoke threshold level. To the left of the bar graph are the Fire 1 Action and Alert smoke threshold indicators. At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to triggering the next level of alarm.High intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition. Similarly any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information. The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified rectified and the system reset.Four large tactile push button keys enable users to reset isolate or silence the detector and control the mode of the display module. The buttons can be disabled to prevent operation of its functions. A lamp test routine is initiated by pressing the Mode key for two seconds. A Manual Scan can be initiated on the LaserSCANNER by holding the Silence button for 2 seconds.Key FeaturesProvides Immediate Status Reporting for a Single VESDA Zone.Allows Zone Control of Assigned VESDA Detector.High Intensity Alarm LEDs.Remote Relay Option.20-Segment Vertical Bar Graph Display.Alarm Threshold Indicators.Built-In Sounder for Audible Warning.Comprehensive Fault Reporting.Multi-mode Numeric Display defaults to smoke obscuration.Recessed Mounting Option.

GBP 993.19
1

Vesda VRT-600 Remote Mount Display for VLP with Remote Termination Card No Relays

Vesda VRT-600 Remote Mount Display for VLP with Remote Termination Card No Relays

Vesda VRT-600 Remote Mount Display for VLP with Remote Termination Card No RelaysThe VRT-600 is a Remote Mount Display Module designed for use with the LaserPLUS range.Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display a 2 digit numeric display an audible sounder clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.The Display Module can be mounted into a detector unit a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations. There are various versions of the display module depending on the type of detector and the relay configuration required. The LaserSCANNER display has a fourth mode for the Numerical Display which shows the First Alarm SectorFAS this being the number of the sector pipe that has detected smoke. For the LaserCOMPACT the Fire 2 LED is omitted. Smoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 120 of the Fire 1 smoke threshold level. To the left of the bar graph are the Fire 1 Action and Alert smoke threshold indicators. At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to triggering the next level of alarm.High intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition. Similarly any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information. The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified rectified and the system reset.Four large tactile push button keys enable users to reset isolate or silence the detector and control the mode of the display module. The buttons can be disabled to prevent operation of its functions. A lamp test routine is initiated by pressing the Mode key for two seconds. A Manual Scan can be initiated on the LaserSCANNER by holding the Silence button for 2 seconds.Key FeaturesProvides Immediate Status Reporting for a Single VESDA Zone.Allows Zone Control of Assigned VESDA Detector.High Intensity Alarm LEDs.Remote Relay Option.20-Segment Vertical Bar Graph Display.Alarm Threshold Indicators.Built-In Sounder for Audible Warning.Comprehensive Fault Reporting.Multi-mode Numeric Display defaults to smoke obscuration.Recessed Mounting Option.

GBP 896.96
1

Vesda VRT-200 Remote Mount Display for VLP with Remote Termination Card 7 Relays

Vesda VRT-200 Remote Mount Display for VLP with Remote Termination Card 7 Relays

Vesda VRT-200 Remote Mount Display for VLP with Remote Termination Card 7 RelaysThe VRT-200 is a LaserPLUS Display Module with Remote Termination Card 7 Relays.Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display a 2 digit numeric display an audible sounder clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.The Display Module can be mounted into a detector unit a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations. There are various versions of the display module depending on the type of detector and the relay configuration required. The LaserSCANNER display has a fourth mode for the Numerical Display which shows the First Alarm SectorFAS this being the number of the sector pipe that has detected smoke. For the LaserCOMPACT the Fire 2 LED is omitted. Smoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 120 of the Fire 1 smoke threshold level. To the left of the bar graph are the Fire 1 Action and Alert smoke threshold indicators. At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to triggering the next level of alarm.High intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition. Similarly any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information. The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified rectified and the system reset.Four large tactile push button keys enable users to reset isolate or silence the detector and control the mode of the display module. The buttons can be disabled to prevent operation of its functions. A lamp test routine is initiated by pressing the Mode key for two seconds. A Manual Scan can be initiated on the LaserSCANNER by holding the Silence button for 2 seconds.Key Features7 RelaysProvides Immediate Status Reporting for a Single VESDA Zone.Allows Zone Control of Assigned VESDA Detector.High Intensity Alarm LEDs.Remote Relay Option.20-Segment Vertical Bar Graph Display.Alarm Threshold Indicators.Built-In Sounder for Audible Warning.Comprehensive Fault Reporting.Multi-mode Numeric Display defaults to smoke obscuration.Recessed Mounting Option.

GBP 984.44
1

Vesda VRT-J00 Remote Mount Display for VLC with Remote Termination Card 7 relays

Vesda VRT-J00 Remote Mount Display for VLC with Remote Termination Card 7 relays

Vesda VRT-J00 Remote Mount Display for VLC with Remote Termination Card 7 relaysThe VRT-J00 is a Remote Display Module designed for use with the LaserCOMPACT range.Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display a 2 digit numeric display an audible sounder clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.The Display Module can be mounted into a detector unit a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations. There are various versions of the display module depending on the type of detector and the relay configuration required. The LaserSCANNER display has a fourth mode for the Numerical Display which shows the First Alarm SectorFAS this being the number of the sector pipe that has detected smoke. For the LaserCOMPACT the Fire 2 LED is omitted. Smoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 120 of the Fire 1 smoke threshold level. To the left of the bar graph are the Fire 1 Action and Alert smoke threshold indicators. At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to triggering the next level of alarm.High intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition. Similarly any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information. The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified rectified and the system reset.Four large tactile push button keys enable users to reset isolate or silence the detector and control the mode of the display module. The buttons can be disabled to prevent operation of its functions. A lamp test routine is initiated by pressing the Mode key for two seconds. A Manual Scan can be initiated on the LaserSCANNER by holding the Silence button for 2 seconds.Key FeaturesProvides Immediate Status Reporting for a Single VESDA Zone.Allows Zone Control of Assigned VESDA Detector.High Intensity Alarm LEDs.Remote Relay Option.20-Segment Vertical Bar Graph Display.Alarm Threshold Indicators.Built-In Sounder for Audible Warning.Comprehensive Fault Reporting.Multi-mode Numeric Display defaults to smoke obscuration.Recessed Mounting Option.

GBP 1167.56
1

Vesda VRT-800 Remote Mount Display for VLS with Remote Termination Card with 12 Relays

Vesda VRT-800 Remote Mount Display for VLS with Remote Termination Card with 12 Relays

Vesda VRT-800 Remote Mount Display for VLS with Remote Termination Card with 12 RelaysThe VRT-800 is a Remote Display Module designed for use with the LaserSCANNER range.Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display a 2 digit numeric display an audible sounder clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.The Display Module can be mounted into a detector unit a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations. There are various versions of the display module depending on the type of detector and the relay configuration required. The LaserSCANNER display has a fourth mode for the Numerical Display which shows the First Alarm SectorFAS this being the number of the sector pipe that has detected smoke. For the LaserCOMPACT the Fire 2 LED is omitted. Smoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 120 of the Fire 1 smoke threshold level. To the left of the bar graph are the Fire 1 Action and Alert smoke threshold indicators. At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to triggering the next level of alarm.High intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition. Similarly any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information. The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified rectified and the system reset.Four large tactile push button keys enable users to reset isolate or silence the detector and control the mode of the display module. The buttons can be disabled to prevent operation of its functions. A lamp test routine is initiated by pressing the Mode key for two seconds. A Manual Scan can be initiated on the LaserSCANNER by holding the Silence button for 2 seconds.Key FeaturesProvides Immediate Status Reporting for a Single VESDA Zone.Allows Zone Control of Assigned VESDA Detector.High Intensity Alarm LEDs.Remote Relay Option.20-Segment Vertical Bar Graph Display.Alarm Threshold Indicators.Built-In Sounder for Audible Warning.Comprehensive Fault Reporting.Multi-mode Numeric Display defaults to smoke obscuration.Recessed Mounting Option.

GBP 1158.24
1

Vesda VRT-100 Remote Mount Programmer

Vesda VRT-100 Remote Mount Programmer

Vesda VRT-100 Remote Mount ProgrammerThe Programmer Module allows direct access to all VESDAnet devices on an VESDA smoke detection system. It allows configuration and status reporting of detectors displays and interfaces and is required when installing commissioning and maintaining a VESDA network. By incorporating a user friendly menu navigation through the comprehensive features of VESDAnet is convenient and simple.The programmer module is available as a hand-held device with included DB15 serial cable or can be mounted into a VESDA VLP or VESDA VLS detector a remote mounting box or a 19 inch sub rack. The two rows of large push buttons enable the user to log ON and navigate through the menu trees to the various command and parameter setting functions. The top row of keys are called Soft Keys and are assigned programming options appropriate to the screen being viewed.Some of the parameters that can be accessed via the programmer include device status reporting zone number and name allocation flow normalisation alarm threshold setting day night weekend initiation of AutoLearn wiring order relay testing and event log review. Up to 14 assigned Users or Administrators with an individual 4 digit Personal Identification Number PIN and one Distributor can log onto a VESDAnet system under one of three levels of access which are password protectedUser USR is only able to view parameters check status alarms and reset the system.Administrator ADM has access to most commands and programming parameters.Distributor DST is the topmost level and has unlimited access to all commands and parameters in the system.Lost PIN numbers can be overcome by obtaining a once only pass number from your Xtralis VESDA dealer.The programmer automatically logs OFF when not in use for more than 10 minutes. The user is prompted with a beeping sound at 1 minute and at 15 seconds before log OFF. Any key may be pressed to cancel the automatic log OFF process.Key FeaturesUser friendly menu systemSupports multiple languagesSingle point access to entire VESDAnet systemAlarm and fault simulationShows wiring orderLocates communications failuresPassword securityHand held or remote mountingAutomatic Logoff when inactiveBacklit LCD screen

GBP 955.28
1

Vesda VRT-400 LaserSCANNER Display With Remote Termination Card 7 Relays

Vesda VRT-400 LaserSCANNER Display With Remote Termination Card 7 Relays

Vesda VRT-400 LaserSCANNER Display With Remote Termination Card 7 RelaysThe VRT-400 is a LaserSCANNER Display Module with Remote Termination Card.Display modules provide real-time indication of the status of a VESDA detector. They have a 20-segment vertical bar graph display a 2 digit numeric display an audible sounder clear alarm and fault indicators. They also have 4 push button keys to control the detector and the mode of the display.The Display Module can be mounted into a detector unit a remote mounting box or a 19in sub rack. Several displays can be configured to display information from a single detector in multiple locations. There are various versions of the display module depending on the type of detector and the relay configuration required. The LaserSCANNER display has a fourth mode for the Numerical Display which shows the First Alarm SectorFAS this being the number of the sector pipe that has detected smoke. For the LaserCOMPACT the Fire 2 LED is omitted. Smoke levels are continuously shown on a bar graph display where each illuminated segment indicates the current level of detected smoke.The top segment of the bar graph indicates the Fire 1 smoke threshold level and each segment below that level represents 120 of the Fire 1 smoke threshold level. To the left of the bar graph are the Fire 1 Action and Alert smoke threshold indicators. At a glance these provide a visual representation of the programmable alarm thresholds showing how close the smoke level is to triggering the next level of alarm.High intensity flashing LEDs provide a clear indication of the fire condition and are accompanied by an audible warning appropriate to the alarm condition. Similarly any fault condition is indicated by a series of LEDs and an audible tone providing a comprehensive range of status information. The audible warning is easily silenced by pressing the Silence button at which point any flashing LEDs are illuminated until the cause of the event is identified rectified and the system reset.Four large tactile push button keys enable users to reset isolate or silence the detector and control the mode of the display module. The buttons can be disabled to prevent operation of its functions. A lamp test routine is initiated by pressing the Mode key for two seconds. A Manual Scan can be initiated on the LaserSCANNER by holding the Silence button for 2 seconds.Key Features7 RelaysProvides Immediate Status Reporting for a Single VESDA Zone.Allows Zone Control of Assigned VESDA Detector.High Intensity Alarm LEDs.Remote Relay Option.20-Segment Vertical Bar Graph Display.Alarm Threshold Indicators.Built-In Sounder for Audible Warning.Comprehensive Fault Reporting.Multi-mode Numeric Display defaults to smoke obscuration.Recessed Mounting Option.

GBP 1120.91
1

Vesda Sensepoint XCL XCL-VEA-CO-RA Carbon Monoxide CO 0-300PPM 4-20mA Relays