434 results (0,15043 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Apollo Discovery Marine Standard Mounting Base 45681-210MAR

Fire Action Notice In Event Of Fire Break Glass - Vinyl 150mm x 200mm FAN1V

Fire Action Notice In Event Of Fire Break Glass - Rigid 150mm x 200mm FAN1R

Apollo XP95 Intelligent Mounting Base 45681-210APO

Apollo XP95 Intelligent Mounting Base 45681-210APO

Apollo XP95 Mounting Base - 45681-210APOAll detectors in the Discovery range fit the IntelligentMounting Base. The Mounting Base is a low insertion force base with stainless steel contacts for the detector terminals. XPERT cards are supplied with all bases.Universal address cards known as XPERT cards are supplied with all bases. Consult the coding guide in the installation instructions to determine which pips are to be removed from the card to give the correct address.Lay the card on a flat surface pips down insert a screwdriver into the slot on the reverse of the pip to be removed and give a firm twist. When the card is coded insert it into the slot in the side of the appropriate base making sure that the card locks itself into place. As a detector is inserted into the base the remaining pips operate the address buttons on the detector and the detector electronics reads the address.OperatingAn earth connection is not required for either safety or correct operation of detectors. The ground earth terminal is isolated and is provided for tidy termination of grounded conductors or cable screens and to maintain earth continuity where necessary. All terminals are marked according to their function.Bases have a wide interior diameter for ease of access to cables and terminals and there are two slots for fixing screws. The slots enable two fixing screws to be located at a spacing of 51mm to 69mm. Detectors fit into bases one way only without snagging and require clockwise rotation without push force to be plugged in.Key Features XPERT AddressingOne way fit of detectorLocking feature to prevent unauthorised detector removal

GBP 2.50
1

Kidde N-MC-RE Intelligent Manual Call Point Resettable Element

Apollo XP95 EN54 Glass Replacement 26729-154

Apollo Blank XPert Card for XPander Wireless Range - White 29600-413

Fireclass 516.800.931FC Address Flag Labels Loop A White

Fireclass 516.800.934FC Address Flag Labels Loop D Green

Fireclass 516.800.932FC Address Flag Labels Loop B Yellow

Fireclass 516.800.933FC Address Flag Labels Loop C Purple

Apollo Backplate 45681-233APO

Ziton ZP755-COV-R Cover for Base Sounder

Apollo XP95 Discovery Isolator Base 45681-211APO

Apollo Blank XPert Card for XPander Wireless Range -Red 29600-399

Apollo Blank XPert Card for XPander Wireless Range -Red 29600-399

Apollo Blank XPert Card for XPander Wireless Range RedSpare singular blank XPERT card in red for the XPander range. XPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop.XPander incorporates entirely new designs with respect to the wireless communication system. A Radio Interface is connected to the loop. It communicates with the control panel using the Apollo addressable two-wire power and communications system. The interface communicates with the detection and alarm signalling devices by means of radio waves. The detectors are multistate in that they report normal pre-alarm fire or fault states to the radio base which transmits the information to the interface. The detectors incorporate drift compensation and report any compensation limit occurring. The radio bases and signalling devices are addressable and use a pre-set analogue value to report via the XP95 or Discovery protocol. Apart from normal and fire the bases can send pre-set analogue values to indicate low battery detector contaminated detector tamper and low signal strength fault conditions.Brand Featuresmodern styling loop-powered interface operating on 868MHz wireless addresses seen by control panel as normal addresses radio base with wireless circuitry and battery compartment chamber designed to inhibit dirt penetration and thus reduce false alarms automatic drift compensation with DirtAlert warning algorithms for transient alarm rejection FasTest reduces time taken to test detectors remote test facility 3-5 years battery lifeProduct InformationAddress card supplied with all bases. Using a coding guide pips are removed to set the address of the inserted device.Key FeaturesSimplifies and speeds up installation and commissioningAddress remains the same no matter how often detectors are replacedUses patented proven technologyFlexibility to create any address

GBP 0.24
1

STI STI-CI Reset Integral Cover - Hinged Clear