Duomo CellAir Pub Cellar CO2 Alarm with Remote Display

Carrier GST-IFP8 Intelligent Addressable Control Panel - CIE - 8 Loop - 140 Zone

Vesda VSP-001 VLP amp VLS Programmer Module

SAS NET201 System Control Hub and Power Supply Unit PSU

Nursecall Intercall L748 Corridor LED Display with Illuminated 100mm Characters

Nursecall Intercall L748 Corridor LED Display with Illuminated 100mm Characters

Nursecall Intercall L748 Corridor LED Display with Illuminated 100mm CharactersThe L748 Corridor LED Display is ideal for where calls need to be easily and clearly seen by staff on the move. It may be used in several applications including hospitals doctors surgeries and larger nursing homes. Call information is very clearly displayed on the illuminated 16 character display. The integral alarm is adjustable for day and night volumes the display may be configured to show a standing message or appear off when no calls are active on the system. The unit is compatible with the INTERCALL 700 protocol only and shows the same text as the LCD display units.The unit can either operate as the only type of display on the system or can be used in conjunction with the standard LCD units. Operation of the unit is similar to the standard LCD units with all calls numbered in queue order. Emergency and Attack calls are flashed on the display to show the higher priority while normal assistance and priority calls are stored in memory but not displayed until the higher priority calls are dealt with. There are no user controls on the unit however the display menus controls are available and the unit has a unique display menu structure for configuration. These menus are configured using the two buttons in a similar manor to the standard display.Key FeaturesThe unit can either operate as the only type of display on the system or can be used in conjunction with the standard LCD units

GBP 998.33
1

Notifier ID60 Single Loop Intelligent Fire Alarm Panel 002-456

Notifier ID60 Single Loop Intelligent Fire Alarm Panel 002-456

Notifier ID60 Single Loop Intelligent Fire Alarm Panel 002-456The NOTIFIER ID60 Series Single Loop intelligent fire alarm panel has been developed for both installers and end users with efficiency in mind offering a technically advanced range of facilities and functions while remaining easy to install program and operate. Three models are available in the ID60 series. The compact ID60 the ID61 with internal printer option and a larger separate power supply and the ID62 with internal printer option a larger separate power supply and added space for 72 hours battery back-up.The ID60 series supports NOTIFIERs unique Very Intelligent Early Warning VIEW technology. Combined with the patented AWACS Advance Warning Addressable Combustion Sensing and DIG Dynamic Intelligent Grouping algorithms the ID60 series provides the most cost-effective stable and reliable early warning systems without the need to use costly aspirating detection systems.With A compact enclosure 380mm x 365mm x 110mm and a single PCB with on-board power supply 1.5A the ID60 provides the user with an easy to installmaintain Fire Alarm System.Key FeaturesLPCB approved to EN54 Parts 2 and 4One loop capacity 99 sensors and 99 modules16 fire zones 16 non fire zonesSupports advanced detection such as VIEW HARSH OptiPlex HAZARD64 CBE rules10 Pre-alarm levels per sensor9 Alarm levels per sensorDrift compensationMaintenance alertAutomatic High TestDay Night mode facilityTime programsClass ChangeAutolearn facilityOne man walk test2 x 40 character backlit LCDActive and passive repeatersProgrammable from the panel keypad or PCSupports loop powered sounders relaysTwo on board sounder circuitsTwo on board configurable outputs

GBP 1015.62
1

Advanced LLED3NM3P REMCWP LED-Lite Weatherproof Downlighter Recessed Addressable Non-Maintained

Advanced LLED3NM3P REMCWP LED-Lite Weatherproof Downlighter Recessed Addressable Non-Maintained

Advanced LLED3NM3PREMCWP LED-Lite Weatherproof Downlighter Recessed Addressable Non-MaintainedThe LED-Lite range of recessed luminaires offers a simple method of providing discrete emergency lighting in areas that require a self-contained solution. Available with a symmetrical wide-angle lens or an asymmetrical corridor lens for escape routes or a narrow 20 degree high level beam for highlighting points of emphasis the luminaire simply requires a permanent 230 Volt supply and addressable wiring to provide effective non-maintained emergency lighting with a 3-hour duration. It is available in a maintained version for such applications as night lighting in hospital wards. This version comes complete with a robust remote enclosure which houses all the control components. An alternative LED head is available that uses three 1W LEDs in a dichroic housing complete with a through hole flame-retardant pack to allow installation into solid ceilings such as plaster. The LED-Lite fully supports all features of the LuxIntelligent test system. IP65 weatherproof versions available for outside usage.OperationThe LED-Lite is supplied with integral non-maintained emergency lighting control gear. The self-contained unit offers 3-hour emergency lighting duration from integral nickel-metal hydride batteries. The LED-Lite incorporates a green LED to provide battery charge indication. The luminaires will automatically provide emergency lighting in the event of a loss of local mains supply. The benefits of modern LEDs are well documented.InstallationThe LED-Lite recessed units can be discretely mounted in a 45mm cut-out. When the corridor lens is specified the LED can easily be rotated to align the distribution along the escape route.

GBP 475.15
1

Advanced LLED3NM3 PREMHOWP LED-Lite High Output Weatherproof Downlighter Recessed Addressable

Advanced LLED3NM3 PREMHOWP LED-Lite High Output Weatherproof Downlighter Recessed Addressable

Advanced LLED3NM3PREMHOWP LED-Lite High Output Weatherproof Downlighter Recessed AddressableThe LED-Lite range of recessed luminaires offers a simple method of providing discrete emergency lighting in areas that require a self-contained solution. Available with a symmetrical wide-angle lens or an asymmetrical corridor lens for escape routes or a narrow 20 degree high level beam for highlighting points of emphasis the luminaire simply requires a permanent 230 Volt supply and addressable wiring to provide effective non-maintained emergency lighting with a 3-hour duration. It is available in a maintained version for such applications as night lighting in hospital wards. This version comes complete with a robust remote enclosure which houses all the control components. An alternative LED head is available that uses three 1W LEDs in a dichroic housing complete with a through hole flame-retardant pack to allow installation into solid ceilings such as plaster. The LED-Lite fully supports all features of the LuxIntelligent test system. IP65 weatherproof versions available for outside usage.OperationThe LED-Lite is supplied with integral non-maintained emergency lighting control gear. The self-contained unit offers 3-hour emergency lighting duration from integral nickel-metal hydride batteries. The LED-Lite incorporates a green LED to provide battery charge indication. The luminaires will automatically provide emergency lighting in the event of a loss of local mains supply. The benefits of modern LEDs are well documented.InstallationThe LED-Lite recessed units can be discretely mounted in a 45mm cut-out. When the corridor lens is specified the LED can easily be rotated to align the distribution along the escape route.

GBP 529.86
1

Advanced LLED3NM3P REMCHOWP LED-Lite High Output Weatherproof Downlighter Recessed Addressable

Advanced LLED3NM3P REMCHOWP LED-Lite High Output Weatherproof Downlighter Recessed Addressable

Advanced LLED3NM3PREMCHOWP LED-Lite High Output Weatherproof Downlighter Recessed AddressableThe LED-Lite range of recessed luminaires offers a simple method of providing discrete emergency lighting in areas that require a self-contained solution. Available with a symmetrical wide-angle lens or an asymmetrical corridor lens for escape routes or a narrow 20 degree high level beam for highlighting points of emphasis the luminaire simply requires a permanent 230 Volt supply and addressable wiring to provide effective non-maintained emergency lighting with a 3-hour duration. It is available in a maintained version for such applications as night lighting in hospital wards. This version comes complete with a robust remote enclosure which houses all the control components. An alternative LED head is available that uses three 1W LEDs in a dichroic housing complete with a through hole flame-retardant pack to allow installation into solid ceilings such as plaster. The LED-Lite fully supports all features of the LuxIntelligent test system. IP65 weatherproof versions available for outside usage.OperationThe LED-Lite is supplied with integral non-maintained emergency lighting control gear. The self-contained unit offers 3-hour emergency lighting duration from integral nickel-metal hydride batteries. The LED-Lite incorporates a green LED to provide battery charge indication. The luminaires will automatically provide emergency lighting in the event of a loss of local mains supply. The benefits of modern LEDs are well documented.InstallationThe LED-Lite recessed units can be discretely mounted in a 45mm cut-out. When the corridor lens is specified the LED can easily be rotated to align the distribution along the escape route.

GBP 529.86
1

Advanced LLED3NM3P REMHLHOWP LED-Lite High Output Weatherproof Downlighter Recessed Addressable

Advanced LLED3NM3P REMHLHOWP LED-Lite High Output Weatherproof Downlighter Recessed Addressable

Advanced LLED3NM3PREMHLHOWP LED-Lite High Output Weatherproof Downlighter Recessed AddressableThe LED-Lite range of recessed luminaires offers a simple method of providing discrete emergency lighting in areas that require a self-contained solution. Available with a symmetrical wide-angle lens or an asymmetrical corridor lens for escape routes or a narrow 20 degree high level beam for highlighting points of emphasis the luminaire simply requires a permanent 230 Volt supply and addressable wiring to provide effective non-maintained emergency lighting with a 3-hour duration. It is available in a maintained version for such applications as night lighting in hospital wards. This version comes complete with a robust remote enclosure which houses all the control components. An alternative LED head is available that uses three 1W LEDs in a dichroic housing complete with a through hole flame-retardant pack to allow installation into solid ceilings such as plaster. The LED-Lite fully supports all features of the LuxIntelligent test system. IP65 weatherproof versions available for outside usage.OperationThe LED-Lite is supplied with integral non-maintained emergency lighting control gear. The self-contained unit offers 3-hour emergency lighting duration from integral nickel-metal hydride batteries. The LED-Lite incorporates a green LED to provide battery charge indication. The luminaires will automatically provide emergency lighting in the event of a loss of local mains supply. The benefits of modern LEDs are well documented.InstallationThe LED-Lite recessed units can be discretely mounted in a 45mm cut-out. When the corridor lens is specified the LED can easily be rotated to align the distribution along the escape route.

GBP 529.86
1

Advanced LLED3NM3 PREMHO LED-Lite High Output Downlighter Recessed Non-Maintained Addressable

Advanced LLED3NM3 PREMHO LED-Lite High Output Downlighter Recessed Non-Maintained Addressable

Advanced LLED3NM3 PREMHO LED-Lite High Output Downlighter Recessed Non-Maintained AddressableThe LED-Lite range of recessed luminaires offers a simple method of providing discrete emergency lighting in areas that require a self-contained solution. Available with a symmetrical wide-angle lens or an asymmetrical corridor lens for escape routes or a narrow 20 degree high level beam for highlighting points of emphasis the luminaire simply requires a permanent 230 Volt supply and addressable wiring to provide effective non-maintained emergency lighting with a 3-hour duration. It is available in a maintained version for such applications as night lighting in hospital wards. This version comes complete with a robust remote enclosure which houses all the control components. An alternative LED head is available that uses three 1W LEDs in a dichroic housing complete with a through hole flame-retardant pack to allow installation into solid ceilings such as plaster. The LED-Lite fully supports all features of the LuxIntelligent test system. IP65 weatherproof versions available for outside usage.OperationThe LED-Lite is supplied with integral non-maintained emergency lighting control gear. The self-contained unit offers 3-hour emergency lighting duration from integral nickel-metal hydride batteries. The LED-Lite incorporates a green LED to provide battery charge indication. The luminaires will automatically provide emergency lighting in the event of a loss of local mains supply. The benefits of modern LEDs are well documented.InstallationThe LED-Lite recessed units can be discretely mounted in a 45mm cut-out. When the corridor lens is specified the LED can easily be rotated to align the distribution along the escape route.

GBP 497.72
1

Advanced LLED3NM3 PHLREMHO LED-Lite High Output Downlighter Recessed Non-Maintained Addressable

Advanced LLED3NM3 PHLREMHO LED-Lite High Output Downlighter Recessed Non-Maintained Addressable

Advanced LLED3NM3PHLREMHO LED-Lite High Output Downlighter Recessed Non-Maintained AddressableThe LED-Lite range of recessed luminaires offers a simple method of providing discrete emergency lighting in areas that require a self-contained solution. Available with a symmetrical wide-angle lens or an asymmetrical corridor lens for escape routes or a narrow 20 degree high level beam for highlighting points of emphasis the luminaire simply requires a permanent 230 Volt supply and addressable wiring to provide effective non-maintained emergency lighting with a 3-hour duration. It is available in a maintained version for such applications as night lighting in hospital wards. This version comes complete with a robust remote enclosure which houses all the control components. An alternative LED head is available that uses three 1W LEDs in a dichroic housing complete with a through hole flame-retardant pack to allow installation into solid ceilings such as plaster. The LED-Lite fully supports all features of the LuxIntelligent test system. IP65 weatherproof versions available for outside usage.OperationThe LED-Lite is supplied with integral non-maintained emergency lighting control gear. The self-contained unit offers 3-hour emergency lighting duration from integral nickel-metal hydride batteries. The LED-Lite incorporates a green LED to provide battery charge indication. The luminaires will automatically provide emergency lighting in the event of a loss of local mains supply. The benefits of modern LEDs are well documented.InstallationThe LED-Lite recessed units can be discretely mounted in a 45mm cut-out. When the corridor lens is specified the LED can easily be rotated to align the distribution along the escape route.

GBP 497.72
1

Notifier ID61 Single Loop Intelligent Fire Alarm Panel 002-463

Notifier ID61 Single Loop Intelligent Fire Alarm Panel 002-463

Notifier ID61 Single Loop Intelligent Fire Alarm Panel 002-463The NOTIFIER ID60 Series Single Loop intelligent fire alarm panel has been developed for both installers and end users with efficiency in mind offering a technically advanced range of facilities and functions while remaining easy to install program and operate. Three models are available in the ID60 series. The compact ID60 the ID61 with internal printer option and a larger separate power supply and the ID62 with internal printer option a larger separate power supply and added space for 72 hours battery back-up.The ID60 series supports NOTIFIERs unique Very Intelligent Early Warning VIEW technology. Combined with the patented AWACS Advance Warning Addressable Combustion Sensing and DIG Dynamic Intelligent Grouping algorithms the ID60 series provides the most cost-effective stable and reliable early warning systems without the need to use costly aspirating detection systems.The ID61 is housed in a slightly larger enclosure 500mm x 400mm x 110mm than the ID60 to accommodate for an internal mounted printer. A larger separate power supply 3A is fitted in the ID61 to cater for the more power hungry applications.Key FeaturesLPCB approved to EN54 Parts 2 and 4One loop capacity 99 sensors and 99 modules16 fire zones 16 non fire zonesSupports advanced detection such as VIEW HARSH OptiPlex HAZARD64 CBE rules10 Pre-alarm levels per sensor9 Alarm levels per sensorDrift compensationMaintenance alertAutomatic High TestDay Night mode facilityTime programsClass ChangeAutolearn facilityOne man walk test2 x 40 character backlit LCDActive and passive repeatersProgrammable from the panel keypad or PCSupports loop powered sounders relaysTwo on board sounder circuitsTwo on board configurable outputs

GBP 1808.16
1

Advanced LLED3NM3P REMHLWP LED-Lite Weatherproof Downlighter Recessed Addressable Non-Maintained

Advanced LLED3NM3P REMHLWP LED-Lite Weatherproof Downlighter Recessed Addressable Non-Maintained

Advanced LLED3NM3PREMHLWP LED-Lite Weatherproof Downlighter Recessed Addressable Non-MaintainedThe LED-Lite range of recessed luminaires offers a simple method of providing discrete emergency lighting in areas that require a self-contained solution. Available with a symmetrical wide-angle lens or an asymmetrical corridor lens for escape routes or a narrow 20 degree high level beam for highlighting points of emphasis the luminaire simply requires a permanent 230 Volt supply and addressable wiring to provide effective non-maintained emergency lighting with a 3-hour duration. It is available in a maintained version for such applications as night lighting in hospital wards. This version comes complete with a robust remote enclosure which houses all the control components. An alternative LED head is available that uses three 1W LEDs in a dichroic housing complete with a through hole flame-retardant pack to allow installation into solid ceilings such as plaster. The LED-Lite fully supports all features of the LuxIntelligent test system. IP65 weatherproof versions available for outside usage.OperationThe LED-Lite is supplied with integral non-maintained emergency lighting control gear. The self-contained unit offers 3-hour emergency lighting duration from integral nickel-metal hydride batteries. The LED-Lite incorporates a green LED to provide battery charge indication. The luminaires will automatically provide emergency lighting in the event of a loss of local mains supply. The benefits of modern LEDs are well documented.InstallationThe LED-Lite recessed units can be discretely mounted in a 45mm cut-out. When the corridor lens is specified the LED can easily be rotated to align the distribution along the escape route.

GBP 475.15
1

Advanced LLED3NM3P REMWP LED-Lite Weatherproof Downlighter Recessed Surface Mount Addressable Non-Maintained

Advanced LLED3NM3P REMWP LED-Lite Weatherproof Downlighter Recessed Surface Mount Addressable Non-Maintained

Advanced LLED3NM3PREMWP LED-Lite Weatherproof Downlighter Recessed Surface Mount Addressable Non-MaintainedThe LED-Lite range of recessed luminaires offers a simple method of providing discrete emergency lighting in areas that require a self-contained solution. Available with a symmetrical wide-angle lens or an asymmetrical corridor lens for escape routes or a narrow 20 degree high level beam for highlighting points of emphasis the luminaire simply requires a permanent 230 Volt supply and addressable wiring to provide effective non-maintained emergency lighting with a 3-hour duration. It is available in a maintained version for such applications as night lighting in hospital wards. This version comes complete with a robust remote enclosure which houses all the control components. An alternative LED head is available that uses three 1W LEDs in a dichroic housing complete with a through hole flame-retardant pack to allow installation into solid ceilings such as plaster. The LED-Lite fully supports all features of the LuxIntelligent test system. IP65 weatherproof versions available for outside usage.OperationThe LED-Lite is supplied with integral non-maintained emergency lighting control gear. The self-contained unit offers 3-hour emergency lighting duration from integral nickel-metal hydride batteries. The LED-Lite incorporates a green LED to provide battery charge indication. The luminaires will automatically provide emergency lighting in the event of a loss of local mains supply. The benefits of modern LEDs are well documented.InstallationThe LED-Lite recessed units can be discretely mounted in a 45mm cut-out. When the corridor lens is specified the LED can easily be rotated to align the distribution along the escape route.

GBP 475.15
1

Advanced LLED3NM3 PCREMHO LED-Lite High Output Downlighter Recessed Non-Maintained Addressable

Advanced LLED3NM3 PCREMHO LED-Lite High Output Downlighter Recessed Non-Maintained Addressable

Advanced LLED3NM3 PCREMHO LED-Lite High Output Downlighter Recessed Non-Maintained AddressableThe LED-Lite range of recessed luminaires offers a simple method of providing discrete emergency lighting in areas that require a self-contained solution. Available with a symmetrical wide-angle lens or an asymmetrical corridor lens for escape routes or a narrow 20 degree high level beam for highlighting points of emphasis the luminaire simply requires a permanent 230 Volt supply and addressable wiring to provide effective non-maintained emergency lighting with a 3-hour duration. It is available in a maintained version for such applications as night lighting in hospital wards. This version comes complete with a robust remote enclosure which houses all the control components. An alternative LED head is available that uses three 1W LEDs in a dichroic housing complete with a through hole flame-retardant pack to allow installation into solid ceilings such as plaster. The LED-Lite fully supports all features of the LuxIntelligent test system. IP65 weatherproof versions available for outside usage.OperationThe LED-Lite is supplied with integral non-maintained emergency lighting control gear. The self-contained unit offers 3-hour emergency lighting duration from integral nickel-metal hydride batteries. The LED-Lite incorporates a green LED to provide battery charge indication. The luminaires will automatically provide emergency lighting in the event of a loss of local mains supply. The benefits of modern LEDs are well documented.InstallationThe LED-Lite recessed units can be discretely mounted in a 45mm cut-out. When the corridor lens is specified the LED can easily be rotated to align the distribution along the escape route.

GBP 497.72
1

Vesda VHX-0310 PC Link HLI Open Protocol Master Slave

Vesda VHX-0310 PC Link HLI Open Protocol Master Slave

Vesda VHX-0310 PC Link HLI Open Protocol Master SlaveA VESDA High Level Interface HLI enables connection between a VESDAnet and configuration and monitoring platforms. Two main models are available1 Sliding Windows HLI which enables communication between a VESDAnet and configuration and monitoring software packages Xtralis VSC and Xtralis VSM4 and2 Open Protocol HLI which integrates a VESDAnet to third-party software packages building management systems BMSs and fire alarm control panels FACPs.These HLIs are available in a plastic portable housing which can be used in multiple sites and a fixed wall-mounted configuration to provide a permanent connection in a convenient location at one site.In the master-slave model the host supervises the communications link between itself and the HLI slave by regularly polling the HLI to determine whether there has been a change in the status of a detector on VESDAnet. In response to polling by the host the HLI generates a single response which is sent back to the host.In this way no unsolicited messages are sent from the HLI to the host. Depending on the polling strategy adopted the Master Slave Open Protocol HLI can report any and all fire alarms within a few seconds of a detector going into alarm. Exact performance is dependent on the polling strategy adopted.Key FeaturesDirect access and monitoring of VESDAnet systemSeamless data transferEasily configured using Xtralis configuring and monitoring software packagesInformation AvailableDetector Type VLC VLS VLP VLF.Alarm status Alert Action Fire1 Fire2.Fault Status System Zone Urgent Power Network Flow Filter.Status Isolated Normalizing AutoLearn Scanning.Display info Alarm thresholds Location name.Display update Smoke level Alarm Fault status.Fault details list of active fault codes.Fault strings ASCII strings to describe each fault code.Detector controls Reset Isolate Silence Test Scan or Normalize2.Configuration of Day Night alarm thresholds2

GBP 1292.38
1

Baldwin Boxall VIGIL2 EVAS Router with 4 Inputs and 4 Audio Outputs BVRD2M4

Baldwin Boxall VIGIL2 EVAS Router with 4 Inputs and 4 Audio Outputs BVRD2M4

Baldwin Boxall VIGIL2 EVAS Router with 4 Inputs and 4 Audio Outputs BVRD2M4The BVRD2M4 is a four-zone voice alarm router with the same great features as the BVRD2M designed for smaller installations and networked decentralised systems.Key FeaturesDSP control.Possible to monitor up to four dual AB circuits.Four electronically balanced inputs. Input one is configurable with all call processor bypass and is normally used for the fire microphone in voice alarm systems. All inputs have both independent priority and level settings allowing for dual mode emergency and normal page.Up to fifteen priority levels are available. If two concurrent routes are set at the same priority they will be treated on a first come first served basis. Priorities are changeable.Three band parametric plus bass and treble equalisation on all inputs with limitercompressor enhancing the intelligibility of the system.Four audio electronically balanced 0dBM outputs with ten band parametric equalisation and audio delay of up to one second.Fully monitored surveillance at either 30Hz or 20kHz faults are recorded in the history log.Built-in real-time clock enables detailed logging and reporting including detected faults. Indicates time date month and year. Also used for night time volume reduction timed message trigger and to control external inputs. The history log can be accessed via the USB2 port on the front panel.Six flash stored 57 second messages with independent level surveillance and timing. Settings and messages are changeable password protected via the USB2 port.Nine selectable chimes pre-announcement tones of up to eight seconds in length.Up to 126 EVAS routers can be networked using fibre or copper to produce a truly sophisticated VA network.Message synchronisation even on a decentralised system.Ambient noise sensing using optional ambient noise sensing microphones.Amplifier changeover for up to three zones using optional relay board product code BVRD2M4ACO.Two RS485 ports for networking microphones etc.Zone grouping and barring on BVRD voice alarm controller.

GBP 1813.49
1

Vesda VHX-1310 Metal Box HLI Master Slave

Vesda VHX-1310 Metal Box HLI Master Slave

Vesda VHX-1310 Metal Box HLI Master SlaveThe VESDA Wall-Mounted Open Protocol High Level Interface HLI links your VESDAnet1 with PC software monitoring tools Building Management Systems BMSs and Fire Alarm Control Panels FACPs otherwise known as host. With a built-in VESDAnet interface you dont need a remote VESDAnet socket module which makes the Wall-mounted HLI a cost-effective solution to your interface requirements. There are two models available depending on whether you require communication between your host and VESDAnet to be master-slave or peer-to-peer.In the master-slave model the host supervises the communications link between itself and the HLI slave by regularly polling the HLI to determine whether there has been a change in the status of a detector on VESDAnet. In response to polling by the host the HLI generates a single response which is sent back to the host. In this way no unsolicited messages are sent from the HLI to the host. Depending on the polling strategy adopted the Master Slave Open Protocol HLI is able to report any and all fire alarms within a few seconds of a detector going into alarm. Exact performance is dependent on the polling strategy adopted.Key FeaturesDirect access and monitoring of your entire VESDAnet systemSeamless data transferEasily configured using Xtralis configuring and monitoring software packages.Information available using the Open Protocol HLIDetector Type VLC VLS VLP VLF.Alarm status Alert Action Fire1 Fire2.Fault Status System Zone Urgent Power Network Flow Filter.Status Isolated Normalizing AutoLearn Scanning.Display info Alarm thresholds Location name.Display update Smoke level Alarm Fault status.Fault details list of active fault codes.Fault strings ASCII strings to describe each fault code.Detector controls Reset Isolate Silence Test Scan or Normalize2 .Configuration of Day Night alarm thresholds2

GBP 2333.39
1

Notifier ID62 Single Loop Intelligent Fire Alarm Panel 002-461

Notifier ID62 Single Loop Intelligent Fire Alarm Panel 002-461

Notifier ID62 Single Loop Intelligent Fire Alarm Panel 002-461The NOTIFIER ID60 Series Single Loop intelligent fire alarm panel has been developed for both installers and end users with efficiency in mind offering a technically advanced range of facilities and functions while remaining easy to install program and operate. Three models are available in the ID60 series. The compact ID60 the ID61 with internal printer option and a larger separate power supply and the ID62 with internal printer option a larger separate power supply and added space for 72 hours battery back-up.The ID60 series supports NOTIFIERs unique Very Intelligent Early Warning VIEW technology. Combined with the patented AWACS Advance Warning Addressable Combustion Sensing and DIG Dynamic Intelligent Grouping algorithms the ID60 series provides the most cost-effective stable and reliable early warning systems without the need to use costly aspirating detection systems.The ID62 is housed in a large enclosure 500mm x 620mm x 208mm to accommodate for an internal mounted printer and space for up to 42AH batteries for 72 hours battery backup. A larger separate power supply 3A is fitted in the ID62 to cater for the more power hungry applications and to provide enough power to support72 hours of battery 42AH backup should the mains AC power fail. Two front covers are provided on the ID62. One is fitted at the top part of the enclosure and one is fitted at the bottom part of the enclosure thereby allowing for easy installation and maintenance of the panel printer and batteries.Key FeaturesLPCB approved to EN54 Parts 2 and 4One loop capacity 99 sensors and 99 modules16 fire zones 16 non fire zonesSupports advanced detection such as VIEW HARSH OptiPlex HAZARD64 CBE rules10 Pre-alarm levels per sensor9 Alarm levels per sensorDrift compensationMaintenance alertAutomatic High TestDay Night mode facilityTime programsClass ChangeAutolearn facilityOne man walk test2 x 40 character backlit LCDActive and passive repeatersProgrammable from the panel keypad or PCSupports loop powered sounders relaysTwo on board sounder circuitsTwo on board configurable outputs

GBP 1872.25
1

Vesda VHX-1300 Metal Box HLI Peer to Peer

Vesda VHX-1300 Metal Box HLI Peer to Peer

Vesda VHX-1300 Metal Box HLI Peer to PeerThe VESDA Wall-Mounted Open Protocol High Level Interface HLI links your VESDAnet with PC software monitoring tools Building Management Systems BMSs and Fire Alarm Control Panels FACPs otherwise known as host. With a built-in VESDAnet interface you dont need a remote VESDAnet socket module which makes the Wall-mounted HLI a cost-effective solution to your interface requirements. There are two models available depending on whether you require communication between your host and VESDAnet to be master-slave or peer-to-peer.In the peer-to-peer model the host polls the HLI for information about devices on VESDAnet while the HLI sends unsolicited messages to the host. In this way both the HLI and host are responsible for supervising the communications link between them. In the peer-to-peer model the host can request and receive multiple messages from the HLI.A VESDA High Level Interface HLI enables connection between a VESDAnet and configuration and monitoring platforms. Two main models are available1 Sliding Windows HLI which enables communication between a VESDAnet and configuration and monitoring software packages Xtralis VSC and Xtralis VSM42 Open Protocol HLI which integrates a VESDAnet to third-party software packages building management systems BMSs and fire alarm control panels FACPs.These HLIs are available in a plastic portable housing which can be used in multiple sites and a fixed wall-mounted configuration to provide a permanent connection in a convenient location at one site.Key FeaturesDirect access and monitoring of your entire VESDAnet systemSeamless data transferEasily configured using Xtralis configuring and monitoring software packages.Information available using the Open Protocol HLIDetector Type VLC VLS VLP VLF.Alarm status Alert Action Fire1 Fire2.Fault Status System Zone Urgent Power Network Flow Filter.Status Isolated Normalizing AutoLearn Scanning.Display info Alarm thresholds Location name.Display update Smoke level Alarm Fault status.Fault details list of active fault codes.Fault strings ASCII strings to describe each fault code.Detector controls Reset Isolate Silence Test Scan or Normalize2 .Configuration of Day Night alarm thresholds2

GBP 2443.61
1

Ziton 71401N 2 Loop Analogue Control Panel 230V

Ziton 71401N 2 Loop Analogue Control Panel 230V

Ziton 71401N 2 Loop Analogue Control Panel 230VRecognise real fires soonerAdvanced panel design combined with high sensitivity smoke and fire sensing enables the ZP3 control panel not only to identify and disregard conditions that would result in false or unwanted alarms but to recognise real fires sooner. The ZP3 is available in 2 and 4 loop configurations accommodating up to 508 sensing addresses. For sites requiring more loops panels may be networked together to form systems capable of controlling more than 30.000 devices from as much as 64 control panels.Unique device addressesUp to 127 line devices detectors call points sounders or interface units may be connected to each of the ZP3 loops. All loop devices incorporate switch settings enabling them to be assigned a unique address the location of which is pinpointed and polled by the panel every two seconds. Variations in the detectors environment caused by increases of temperature or products of combustion are reported to the panel where they are processed and compared to known fire data prior to any alarm output being activated.Software flexibilityConstant communication between control panel and detector enables the ZP3 to provide a wide range of user facilities including pre alarm constant sensitivity adjustment service and near service listings for all detector types. Software flexibility enables facilities such as alarm organisation evacuation procedures and complex cause and effect requirements to be easily programmed into any system. All customer and site data is held in non-volatile flash memory ensuring both ease of initial system data input and subsequent on site amendments and modifications should they be required.Optional facilitiesAn onboard printer module together with a series of facility boards can be added to the standard panel to extend any panel up to 768 programmable inputs and outputs.Remote diagnosticsDesigned to provide the user with full facilities for both fault diagnosis and system configuration off site the remote diagnostics hardware and software package makes information available to service personnel prior to visiting site for remedial action or maintenance activity.Key FeaturesCPR Certified to EN542 and 4Advanced sensing techniquesExtensive networking abilityLoop powered sounders supportEase of operationService and near service facilitySophisticated alarm verificationAutomatic self-testDay night controlRadio loop interface supportAutomatic contamination adjustment for each detectorIntelligent loop isolationSelf-test sounder supportPassword protectionEvent log

GBP 1597.32
1

Vesda VRT-100 Remote Mount Programmer

Vesda VRT-100 Remote Mount Programmer

Vesda VRT-100 Remote Mount ProgrammerThe Programmer Module allows direct access to all VESDAnet devices on an VESDA smoke detection system. It allows configuration and status reporting of detectors displays and interfaces and is required when installing commissioning and maintaining a VESDA network. By incorporating a user friendly menu navigation through the comprehensive features of VESDAnet is convenient and simple.The programmer module is available as a hand-held device with included DB15 serial cable or can be mounted into a VESDA VLP or VESDA VLS detector a remote mounting box or a 19 inch sub rack. The two rows of large push buttons enable the user to log ON and navigate through the menu trees to the various command and parameter setting functions. The top row of keys are called Soft Keys and are assigned programming options appropriate to the screen being viewed.Some of the parameters that can be accessed via the programmer include device status reporting zone number and name allocation flow normalisation alarm threshold setting day night weekend initiation of AutoLearn wiring order relay testing and event log review. Up to 14 assigned Users or Administrators with an individual 4 digit Personal Identification Number PIN and one Distributor can log onto a VESDAnet system under one of three levels of access which are password protectedUser USR is only able to view parameters check status alarms and reset the system.Administrator ADM has access to most commands and programming parameters.Distributor DST is the topmost level and has unlimited access to all commands and parameters in the system.Lost PIN numbers can be overcome by obtaining a once only pass number from your Xtralis VESDA dealer.The programmer automatically logs OFF when not in use for more than 10 minutes. The user is prompted with a beeping sound at 1 minute and at 15 seconds before log OFF. Any key may be pressed to cancel the automatic log OFF process.Key FeaturesUser friendly menu systemSupports multiple languagesSingle point access to entire VESDAnet systemAlarm and fault simulationShows wiring orderLocates communications failuresPassword securityHand held or remote mountingAutomatic Logoff when inactiveBacklit LCD screen

GBP 955.28
1

Vesda VHH-100 Hand Held Programmer Complete with Lead

Vesda VHH-100 Hand Held Programmer Complete with Lead

Vesda VHH-100 Hand Held Programmer Complete with LeadThe Programmer Module allows direct access to all VESDAnet devices on an VESDA smoke detection system. It allows configuration and status reporting of detectors displays and interfaces and is required when installing commissioning and maintaining a VESDA network. By incorporating a user friendly menu navigation through the comprehensive features of VESDAnet is convenient and simple.The programmer module is available as a hand-held device with included DB15 serial cable or can be mounted into a VESDA VLP or VESDA VLS detector a remote mounting box or a 19 inch sub rack.The two rows of large push buttons enable the user to log ON and navigate through the menu trees to the various command and parameter setting functions. The top row of keys are called Soft Keys and are assigned programming options appropriate to the screen being viewed.Some of the parameters that can be accessed via the programmer include device status reporting zone number and name allocation flow normalisation alarm threshold setting day night weekend initiation of AutoLearn wiring order relay testing and event log review.Up to 14 assigned Users or Administrators with an individual 4 digit Personal Identification Number PIN and one Distributor can log onto a VESDAnet system under one of three levels of access which are password protectedUser USR is only able to view parameters check status alarms and reset the system.Administrator ADM has access to most commands and programming parameters.Distributor DST is the topmost level and has unlimited access to all commands and parameters in the system.Lost PIN numbers can be overcome by obtaining a once only pass number from your Xtralis VESDA dealer.The programmer automatically logs OFF when not in use for more than 10 minutes. The user is prompted with a beeping sound at 1 minute and at 15 seconds before log OFF. Any key may be pressed to cancel the automatic log OFF process.Key FeaturesUser friendly menu systemSupports multiple languagesSingle point access to entire VESDAnet systemAlarm and fault simulationShows wiring orderLocates communications failuresPassword securityHand held or remote mountingAutomatic Logoff when inactiveBacklit LCD screen

GBP 919.70
1

Ziton 71501N 4-loop analogue control panel 230V

Ziton 71501N 4-loop analogue control panel 230V

Ziton 71501N 4-loop analogue control panel 230VRecognise real fires soonerAdvanced panel design combined with high sensitivity smoke and fire sensing enables the ZP3 control panel not only to identify and disregard conditions that would result in false or unwanted alarms but to recognise real fires sooner. The ZP3 is available in 2 and 4 loop configurations accommodating up to 508 sensing addresses. For sites requiring more loops panels may be networked together to form systems capable of controlling more than 30 000 devices from as much as 64 control panels.Unique device addressesUp to 127 line devices detectors call points sounders or interface units may be connected to each of the ZP3 loops. All loop devices incorporate switch settings enabling them to be assigned a unique address the location of which is pinpointed and polled by the panel every two seconds. Variations in the detectors environment caused by increases of temperature or products of combustion are reported to the panel where they are processed and compared to known fire data prior to any alarm output being activated.Software flexibilityConstant communication between control panel and detector enables the ZP3 to provide a wide range of user facilities including pre alarm constant sensitivity adjustment service and near service listings for all detector types. Software flexibility enables facilities such as alarm organisation evacuation procedures and complex cause and effect requirements to be easily programmed into any system. All customer and site data is held in non volatile flash memory ensuring both ease of initial system data input and subsequent on site amendments and modifications should they be required.Optional facilitiesAn onboard printer module together with a series of facility boards can be added to the standard panel to extend any panel up to 768 programmable inputs and outputs.Remote diagnosticsDesigned to provide the user with full facilities for both fault diagnosis and system configuration off site the remote diagnostics hardware and software package makes information available to service personnel prior to visiting site for remedial action or maintenance activity.Key FeaturesCPR Certified to EN542 and 4Advanced sensing techniquesExtensive networking abilityLoop powered sounders supportEase of operationService and near service facilitySophisticated alarm verificationAutomatic self testDay night controlRadio loop interface supportAutomatic contamination adjustment for each detectorIntelligent loop isolationSelf test sounder supportPassword protectionEvent log

GBP 2525.29