2.148 results (0,14011 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Vox Ignis ViLX-TMS3-AB Adaptor Board To Connect The ViLX-ACR To The ViLX-TMS3

C-Tec CL1 Mini-Counter Hearing Loop Amplifier Only

C-Tec AMDP Desktop Microphone with Push to Talk

C-Tec NC951 Conventional Accessible Toilet Alarm Kit to BS8300

C-Tec NC951 Conventional Accessible Toilet Alarm Kit to BS8300

C-Tec NC951 Conventional Accessible Toilet Alarm Kit to BS8300The Kit includes everything required for BS8300 clause compliant emergency assistance alarm. Attractively designed and easy to install the NC951 allows a distressed person to raise an alarm in the event of an emergency.To operate the user pulls the cord of a ceiling pull cord to activate a light and sounder outside the WC and on the systems call controller. A new Call Accept facility allows staff to send an intermittent call acknowledgement signal to the WC to confirm help is on the way.The NC951 can be wired in to 4 core stranded security cable but can also be used as a single zone emergency assistance alarm in areas such as changing rooms solariums interview rooms reception areas and more.Kit Contains1 x NC943B 12V 140mA Call Controller cw standby battery and relay1 x NC807C Ceiling Pull Cord1 x NC806CS Overdoor Light cw Sounder1 x NC809DBBT Accessible Toilet Reset Point cw Sounder1 x Accessible WC StickerKey FeaturesThe UKs market-leading Disabled Persons Toilet Alarm kit now with a combined ceiling and wall mountable pull cord unitIncludes everything required for a BS8300 compliant emergency assistance alarmEasy to install simple to useAllows a distressed person to raise an alarm in an emergency. To operate the user pulls the cord of the ceilingwall pull to activate a light and sounder outside the WC and on the systems Call ControllerThe systems Call Accept function allows staff to send an intermittent call acknowledgment signal to the WC to confirm help is on the wayIncludes an NC943B 12V 140mA Call Controller cw standby battery relay NC807C CeilingWall Pull NC806CS Overdoor Light cw Sounder NC809DBBT Accessible Toilet Reset Point cw Sounder NC949 Accessible WC StickerCan be wired in 4 core stranded security cableCan also be used as a single zone assistance alarm in changing rooms solariums interview rooms reception areas more

GBP 116.27
1

C-Tec ML1K ML1 Hearing Loop System

Handheld IR Single Laser Thermometer 72-823 -32 Celsius to 650 Celsius

Handheld IR Single Laser Thermometer 72-823 -32 Celsius to 650 Celsius

Handheld IR Single Laser Thermometer72-823-32 Celsius to 650 CelsiusInfrared thermometers measure the surface temperature of an opaque object. The Thermometers optics sense infrared energy is collected and focused onto a detector. The Thermometers electronics then translate the information into a displayed temperature reading which appears on the display. The laser is used for aiming purposes only.The Thermometer turns on when you press the trigger. The Thermometer turns off when no activity is detected for 8 seconds. To measure temperature aim the Thermometer at the target pull and hold the trigger. Release the trigger to hold a temperature reading. Be sure to consider distance-to-spot size ratio and filed of view. The laser is used for aiming only. To find a hot or cold spot aim the Thermometer outside the target area. Then slowly scan across the area with an up and down motion until you located the hot or cold spot.Key FeaturesSimply point the unit and squeeze the trigger to provide fast accurate surface temperature measurement. Attached laser pointer provides immediate verification of aim. In addition to accuracy specifications this unit delivers an incredible 20-1 Distance to Spot RatioCF measurementBacklit four digit displayTemperature data holdMAXMINDIFAVG temperature displaySleep modeAccuracy 2Operating Temperature Max 650COperating Temperature Min -32CSVHC No SVHC 17-Dec-2014Temperature Measuring Range -32C to 650CWavelength Max 670nmResponse Time 95 - 250ms

GBP 98.10
1

Elmdene STX2402-MOD 24V d.c. PSU 27.6V - Selectable 2 Amp To Load 0.3A Battery Charging or 1.8 Amp To Load 0.7A Battery Charging

Elmdene STX2402-MOD 24V d.c. PSU 27.6V - Selectable 2 Amp To Load 0.3A Battery Charging or 1.8 Amp To Load 0.7A Battery Charging

Elmdene STX2402-MOD 24V d.c. PSU 27.6V - Selectable 2 Amp To Load 0.3A Battery Charging or 1.8 Amp To Load 0.7A Battery ChargingThe STX2402-MOD is a PSU for Fire Systems.The new STX range of switch mode power supplies has been specifically designed for EN54 compliant fire systems.The units include intelligent battery charging using Elmdenes efficient EcoCharge technology possess mains battery monitoring with independent volt free outputs and also feature battery deep discharge protection in the event of a prolonged mains failure.The inclusion of LED indicators provides quick diagnostics of the status of the power supply while a variety of enclosures offer the installer a choice of standby battery backup options.Key Features0.7A Battery Charging1.8 Amp To Load0.3A Battery ChargingSelectable 2 Amp To LoadHigh efficiency Switch Mode operationIntelligent Battery chargingMains Battery monitoring with independent volt free fault outputsDeep discharge protectionUser and Engineer diagnostic LED status indication27.6V dc outputCost effective switch mode technologyEnergy efficientMore efficient in operationSaves power reducing power billsLonger life in the fieldLess prone to failureDeep Discharge ProtectionRemote fault signallingFull rated current to load plus additional current for battery chargingLED indicationVolt-free fault output - EPSVolt-free fault output - PSU faultMains transient protection3 Year warrantyPlease note The image is for illustrative purposes only. Pleasecontact usfor further information.

GBP 111.65
1

Aritech ACL800FL-CONV-W ACL800 Converter - RS485 to TCPIP - Fitted In DIN-RAIL Housing

Aritech ACL800FL-CONV-W ACL800 Converter - RS485 to TCPIP - Fitted In DIN-RAIL Housing

Aritech ACL800FL-CONV-W ACL800 Converter - RS485 to TCPIP - Fitted In DIN-RAIL HousingThe ACL800FL-CONV-W is highly integrated serial to Ethernet Converter that enables you to connect any Carrier biometric reader over a local LAN network or over the Internet to your computer. Configuration of the IP address Dynamic DNS TCPUDP ports can be done from browser or from the ACL800 BioManager software. The software is capable to automatically search IP addresses of the converters as well as the serial numbers of the biometric readers. The device is already pre-set for use with the Biometric Readers.The ACL800 Series consists of all the required elements to establish a range with a state-of-the-art design. This new range consisting of readers stand-alone keypad readers and Request-To-Exit touch sensitive push buttons provides all you need for a coherent look-and feel attractive project. The product line has now expanded new biometric readers.The readers are compatible with the TruPortal 125 KHz credential range and other industry standards like MIFARE Classic - Plus Ultralight and - DESFire EV1. These technologies use the CSN Card Serial Number or UID Unique Identifier as credential identifier. The wiegand output 32 or 56 bit is automatic according to the card type and ensures uniqueness of the MIFARE CSN with 4 and 7 Byte UID. The Proximity card type can be selected through DIP switches in HID only HID and EM HID and Casi Casi only or EM only and Wiegand outputs automatically according to the card type.The ACL800 reader range is compatible with the TruPortal learn-in reader TP-RDR-LRN for learning-in credentials in access control panels like TruPortal. This compatibility is provided for both the 125 KHz and the 13.56 MHz credentials while using the full wiegand format length in the management software also with other third-party packages. There are different mounting possibilities either flush mounted within the electrical wall sockets or surface mounted with a stylish small modern-looking molded design.Key FeaturesIndoorDIN rail mount or wall mountNetwork interface and a RS485 interfaceFitted in a DIN rail housingDedicated IP orand MAC addressVisual LED signalization for TCPUDP packetsDHCP clientDDNS supportFinds portals by ACL800 BioManager

GBP 109.38
1

Vesda Xtralis 25mm to 38 BSP Female Air Line Adaptor PIP-022 Pack of 10

Elmdene STX2405-MOD 24V d.c. PSU 27.6V - 5 Amp To Load 0.8A Battery Charging

Elmdene STX2405-MOD 24V d.c. PSU 27.6V - 5 Amp To Load 0.8A Battery Charging

Elmdene STX2405-MOD 24V d.c. PSU 27.6V - 5 Amp To Load 0.8A Battery ChargingThe STX2405-MOD is a PSU for Fire Systems.The new STX range of switch mode power supplies has been specifically designed for EN54 compliant fire systems.The units include intelligent battery charging using Elmdenes efficient EcoCharge technology possess mains battery monitoring with independent volt free outputs and also feature battery deep discharge protection in the event of a prolonged mains failure.The inclusion of LED indicators provides quick diagnostics of the status of the power supply while a variety of enclosures offer the installer a choice of standby battery backup options.Key Features0.8A Battery Charging5 Amp To Load24V d.c. PSU 27.6VHigh efficiency Switch Mode operationIntelligent Battery chargingMains Battery monitoring with independent volt free fault outputsDeep discharge protectionUser and Engineer diagnostic LED status indication27.6V dc outputCost effective switch mode technologyEnergy efficientMore efficient in operationSaves power reducing power billsLonger life in the fieldLess prone to failureDeep Discharge ProtectionRemote fault signallingFull rated current to load plus additional current for battery chargingLED indicationVolt-free fault output - EPSVolt-free fault output - PSU faultMains transient protection3 Year warrantyPlease note The image is for illustrative purposes only. Pleasecontact usfor further information.

GBP 136.48
1

Elmdene STX2401-MOD 24V d.c. PSU 27.6V 1.2 Amp To Load 0.3A Battery Charging

Elmdene STX2401-MOD 24V d.c. PSU 27.6V 1.2 Amp To Load 0.3A Battery Charging

Elmdene STX2401-MOD 24V d.c. PSU 27.6V 1.2 Amp To Load 0.3A Battery ChargingThe STX2401-MOD is a PSU for Fire Systems.The new STX range of switch mode power supplies has been specifically designed for EN54 compliant fire systems.The units include intelligent battery charging using Elmdenes efficient EcoCharge technology possess mains battery monitoring with independent volt free outputs and also feature battery deep discharge protection in the event of a prolonged mains failure.The inclusion of LED indicators provides quick diagnostics of the status of the power supply while a variety of enclosures offer the installer a choice of standby battery backup options.Key Features0.3A Battery Charging1.2 Amp To LoadHigh efficiency Switch Mode operationIntelligent Battery chargingMains Battery monitoring with independent volt free fault outputsDeep discharge protectionUser and Engineer diagnostic LED status indication27.6V dc outputCost effective switch mode technologyEnergy efficientMore efficient in operationSaves power reducing power billsLonger life in the fieldLess prone to failureDeep Discharge ProtectionRemote fault signallingFull rated current to load plus additional current for battery chargingLED indicationVolt-free fault output - EPSVolt-free fault output - PSU faultMains transient protection3 Year warrantyPlease note The image is for illustrative purposes only. Pleasecontact usfor further information.

GBP 89.46
1

Kentec K16100M2 Battery Box to Match Sigma CPXT amp Syncro AS Styling Max 7 AH Battery Surface

Kentec K16100M3 Battery Box to Match Sigma CPXT amp Syncro AS Styling Max 17 AH Battery Surface

Cooper Fulleon 680001FULL-0022X Symphoni Voice Plus Sounder Beacon - Red Lens - Red Flash - Red Housing - Set to Tone 7