24 results (0,15021 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Vesda Xtralis VSP-870 ASD Restrictor In-Line Flow Assembly

Zeta ZAI-MIMARK1 Input Only Module

Notifier NFX-MM1M Addressable Mini Monitor input module

Apollo SA4700-300APO Intelligent DIN-Rail Switch Monitor

C-Tec QT604 Quantec Monitoring Point with Button Reset

Nittan UG-3 Duct Probe Unit with Built-in Base Terminals

Zeta ZAI-MI Input Only Module

Apollo Marine DIN-Rail Switch Monitor Plus 55000-772MAR

Apollo SA6700-100APO Intelligent Twin Switch Monitor

Zeta ZAIO230STD Mains Switching IO Unit

Global Fire Equipment GFE-MIO Mains Switching IO Module CW Isolator

Zeta ZAIO230MARK1 InputOutput Module Mains Voltage Rated

Apollo Orbis I.S. A1R Heat Detector with Flashing LED ORB-HT-51146-APO

Apollo Orbis I.S. A1R Heat Detector with Flashing LED ORB-HT-51146-APO

Apollo Orbis I.S. A1R Heat Detector with Flashing LED ORB-HT-51146-APOThe Orbis IS Heat Detector monitors temperature by using a single thermistor network which provides a voltage output proportional to the external air temperature. The Orbis IS range incorporates seven heat detector classes to suit a wide range of operating conditions.OperationOrbis I.S. heat detectors have an open-web casing which allows air to flow freely across a thermistor which measures the air temperature every 2 seconds. A microprocessor stores the temperature and compares them with per-set values to determine whether a fixed upper limit - the alarm limit - has been reached. In the case of rate-of-rise detectors the microprocessor uses algorithms to determine how fast the temperature is increasing.Static heat detectors respond only when a fixed temperature has been reached. Rate-of-rise detectors have a fixed upper limit but they also measure the rate of increase in temperature. A fire might thus be detected at an earlier stage then with a static detector so that a rate-of-rise detector is to be preferred to a static heat detector unless sharp increases of heat are part of the normal environment in the area protected by the heat detector.Key FeaturesCan be used for applications where smoke detectors are unsuitableIdeal for environments that are dirty or smoky under normal conditionsReduced incidences of false alarmsIncreased reliability of detection

GBP 77.36
1

Global Fire Equipment GFE-IO-2 Addressable 2-Channel IO Module CW Isolator

GBP 65.52
1

Global Fire Equipment GFE-IO-1 Addressable 1-Channel IO Module CW Isolator

GBP 48.43
1

Global Fire Equipment GFE-IO-3 Addressable 3-Channel IO Module CW Isolator

GBP 82.61
1

Zeta ZIOU230 Interface Module Loop Powered 5.0A Rating

Zeta ZIOU230 Interface Module Loop Powered 5.0A Rating

Zeta ZIOU230 Interface Module Loop Powered 5.0A RatingThe Mains IO Modules are fully monitored loop powered devices which permit the interfacing of third-party equipment with the Fire Alarm Control panel using normally open dry contact connections.The connection to the input is monitored for fault open or short circuit and Alarm conditions.The interface is used to monitor the contacts of an external system which must be interfaced to the Fire Alarm System for example a Flow Switch in a sprinkler system to indicate if the sprinklers have been activated or extinguishant level monitoring in Gas Extinguishing systems etc.Module is provided with a loop short-circuit isolator and with a voltage free single pole change over mains rated output.The output relay is always powered directly from the detection loop. It is not required to use an external 24V DC power supply. Relay operation is confirmed by an on-board red LED. An 8 way D.I.L switch is provided to configure the modules address.This value can be set in the range 1 to 125. The following programmable functions are available Input Activation Mode Delayed Input Alarm Activation Output Delayed Activation.The Simplicity CO 8 range is designed to detect monitor CO concentrations in places such as warehouses car parks tunnels and enclosed buildings where forklifts cars and delivery trucks can produce deadly amounts of carbon monoxide in high traffic areas Carbon Monoxide can accumulate in these areas and can be a serious safety and health concern.Key FeaturesFast Activation ResponseLoop PoweredFive Status LEDs providedLow Power ConsumptionModule features an integral short-circuit loop isolatorSingle mains rated relay contact

GBP 78.77
1

Apollo XPander A1R Heat Detector XPA-HT-11170-APO

Apollo XPander A1R Heat Detector XPA-HT-11170-APO

Apollo XPander A1R Heat Detector XPA-HT-11170-APOThere are two heat detectors in the XPander range designed to suit a wide variety of operating conditions. A Static Heat Detector CS which responds only when a fixed temperature has been reached and a Rate-of-Rise Detector A1R which has a fixed upper limit but in addition measures the rate of increase in temperature.OperationHeat detectors have an open-web casing which allows air to flow freely across a thermistor which measures the air temperature every 2 seconds. A microprocessor stores the temperatures and compares them with pre-set values to determine whether a fixed upper limitthe alarm levelhas been reached. In the case of rate-of-rise detectors the microprocessor uses algorithms to determine how fast the temperature is increasing. Static heat detectors respond only when a fixed temperature has been reached. Rate-of-rise detectors have a fixed upper limit but they also measure the rate of increase in temperature. A fire might thus be detected at an earlier stage than with a static detector so that a rate-of-rise detector is to be preferred to a static heat detector unless sharp increases in temperature are part of the normal environment in the area protected by the heat detector.Key FeaturesWireless Can be used in applications where smoke detectors are unsuitableIdeal for environments that are dirty or smoky under normal conditionsCS detectors are ideal for use in environments with rapid temperature fluctuations such as boiler rooms Bi-directional monitored radio platformFive-year battery life using standard AA alkaline batteries

GBP 69.42
1

Zeta ZAIO230 Mains IO 1 Channel InputOutput Module - Fyreye MKII Protocol

Zeta ZAIO230 Mains IO 1 Channel InputOutput Module - Fyreye MKII Protocol

Zeta ZAIO230 Mains IO 1 Channel InputOutput Module - Fyreye MKII Protocol -8A 230V ACThe Mains IO Modules are fully monitored loop powered devices which permit the interfacing of third-party equipment with the Fire Alarm Control panel using normally open dry contact connections.The connection to the input is monitored for fault open or short circuit and Alarm conditions.The interface is used to monitor the contacts of an external system which must be interfaced to the Fire Alarm System for example a Flow Switch in a sprinkler system to indicate if the sprinklers have been activated or extinguishant level monitoring in Gas Extinguishing systems etc.Module is provided with a loop short-circuit isolator and with a voltage free single pole change over mains rated output. The output relay is always powered directly from the detection loop. It is not required to use an external 24V DC power supply. Relay operation is confirmed by an on-board red LED.An 8-way D.I.L switch is provided to configure the modules address. This value can be set in the range 1 to 125.The following programmable functions are available Input Activation Mode Delayed Input Alarm Activation Output Delayed Activation.The Simplicity CO 8 range is designed to detect monitor CO concentrations in places such as warehouses car parks tunnels and enclosed buildings where forklifts cars and delivery trucks can produce deadly amounts of carbon monoxide in high traffic areas Carbon Monoxide can accumulate in these areas and can be a serious safety and health concern.Key FeaturesFast Activation ResponseLoop PoweredFive Status LEDs providedLow Power ConsumptionModule features an integral short-circuit loop isolatorSingle mains rated relay contact

GBP 57.38
1