1.625 results (0,14003 seconds)

Brand

Merchant

Price (EUR)

Reset filter

Products
From
Shops

Zeta SCM-ACM Conventional Sounder Circuit Module - 2 Circuits

Cooper EOLM-3 End of Line Module Bi-Wire Circuits Box of 8

Advanced QuickZone XL 8 Zone Control Panel with 2 Additional Sounder Circuits and Switched Relay

Advanced QuickZone XL 8 Zone Control Panel with 2 Additional Sounder Circuits and Switched Relay

Advanced QuickZone XL 8 Zone Control Panel with 2 Additional Sounder Circuits and Switched Relay -QZXL-8HSQuickZone XL is up to 12 zone Conventional Twin Wire sav-wire control panel with integral power supply space for standby batteries. The panel continues the attributes of quality and reliability that is easy to install maintain and is simple to operate for the end user. Up to 12 fire zone circuits are provided plus two monitored sounder circuits. Fire and fault VFCO relays Fire Fault switched negative outputs class change and an alert input are also included.The fire zone outputs can be set as Twin Wire by DIL switch selection. The DIL switches are also used to allow Zone interface setting and Access to Level 3 mode. In Level 1 the panel will indicate if there are any faults Supply Fire System General repeater. As well as this the panel is capable of indicating zones in Fire Fault and disablements and delay status. Auxiliary Output and Sounder status will be shown including if the panel is in test mode.Controls enabled in Level 2 include Resound Silence and Reset. Disable and Test modes can also be established at this level as well as muting the internal buzzer and testing the functionality of all the LED indicators. In access Level 3 it is possible to select sounder resound options for zones EN54 requirement select Type A dependency per view and edit dependency functions as well as restore factory settings. The buzzer volume can also be set and the event log viewed. Two Additional monitored sounder outputs programmable switched negative outputs and one programmable relay available with high specification expansion card.Key Features4 to 12 ZonesTwin Wire selection by DIL switchFully approved to EN54-2 4Three year warranty as standardIntegral 3 Amp switch mode PSUClass Change Alert programmable inputsProgrammable relays and outputsTest Mode with or without soundersAlarm load of 2.4A shared across all sounder outputsModular expansion zone cards available2 Additional sounder circuits with high spec expansion cardFully functional repeater panelsCan support up to 8 repeater panelsKey-switch or code entry for activation of controlsSpace for up to 7.0Ah batteriesTwo monitored sounder circuits fitted as standardIntegral detector removal monitoring

GBP 636.84
1

Advanced QZXL-12HS QuickZone 12 Zone Control Panel with 2x Sounder Circuits and Switched Relay

Advanced QZXL-12HS QuickZone 12 Zone Control Panel with 2x Sounder Circuits and Switched Relay

Advanced QZXL-12HS QuickZone 12 Zone Control Panel with 2x Sounder Circuits and Switched RelayQuickZone XL is up to 12 zone Conventional Twin Wire sav-wire control panel with integral power supply space for standby batteries. The panel continues the attributes of quality and reliability that is easy to install maintain and is simple to operate for the end user. Up to 12 fire zone circuits are provided plus two monitored sounder circuits. Fire and fault VFCO relays Fire Fault switched negative outputs class change and an alert input are also included.The fire zone outputs can be set as Twin Wire by DIL switch selection. The DIL switches are also used to allow Zone interface setting and Access to Level 3 mode. In Level 1 the panel will indicate if there are any faults Supply Fire System General repeater. As well as this the panel is capable of indicating zones in Fire Fault and disablements and delay status. Auxiliary Output and Sounder status will be shown including if the panel is in test mode.Controls enabled in Level 2 include Resound Silence and Reset. Disable and Test modes can also be established at this level as well as muting the internal buzzer and testing the functionality of all the LED indicators. In access Level 3 it is possible to select sounder resound options for zones EN54 requirement select Type A dependency per view and edit dependency functions as well as restore factory settings. The buzzer volume can also be set and the event log viewed. Two Additional monitored sounder outputs programmable switched negative outputs and one programmable relay available with high specification expansion card.Key Features4 to 12 ZonesTwin Wire selection by DIL switchFully approved to EN54-2 4Three year warranty as standardIntegral 3 Amp switch mode PSUClass Change Alert programmable inputsProgrammable relays and outputsTest Mode with or without soundersAlarm load of 2.4A shared across all sounder outputsModular expansion zone cards available2 Additional sounder circuits with high spec expansion cardFully functional repeater panelsCan support up to 8 repeater panelsKey-switch or code entry for activation of controlsSpace for up to 7.0Ah batteriesTwo monitored sounder circuits fitted as standardIntegral detector removal monitoring

GBP 799.87
1

Zeta SCM-ZMM Conventional Zone Monitor - 6 Circuits

Zeta SCM-ZMM Conventional Zone Monitor - 6 Circuits

Zeta SCM-ZMM Conventional Zone Monitor - 6 CircuitsThe SCM-ZMM is a six zone monitor module that is designed to be DIN mounted inside of a Smart Connect Multiloop control panel. Its powered and interfaced to the panel via a RJ45 connection.The module has six conventional zones which can be typically used for conventional devices andor for special detectors that are not available in addressable form such as UV detectors aspiration and beam detectors etc.The module monitors and transmits the status normal open short or alarm of a zone with the detectors to a control panel. Each zone input can be programmed to either give an Alarm signal or a technical alarm signal when active. The SCM-ZMM is a six zone monitor module that is designed to be DIN mounted inside of a Smart Connect Multiloop control panel. Its powered and interfaced to the panel via a RJ45 connection.The module has six conventional zones which can be typically used for conventional devices andor for special detectors that are not available in addressable form such as UV detectors aspiration and beam detectors etc. The module monitors and transmits the status normal open short or alarm of a zone with the detectors to a control panel. Each zone input can be programmed to either give an Alarm signal or a technical alarm signal when active.Key FeaturesDesigned to EN54 Part 26 x Conventional ZonesEach zone is monitored for open short circuitExtensive front unit status indicationsQuick and easy to install by plugging the RJ45 cable into the module and control panel cable supplied with unitEach zone input can be configured as either Alarm or Technical Alarm

GBP 182.12
1

EOLM-1 JSB End Of Line Module Conventional Circuits

Fireclass 517.001.301FC MTL7728 Zener Safety Barrier for Conventional Detection Circuits

Fireclass 517.001.301FC MTL7728 Zener Safety Barrier for Conventional Detection Circuits

Fireclass 517.001.301FC MTL7728 Zener Safety Barrier for Conventional Detection CircuitsThe MTL7728 is an intrinsically safe zone-powered Zener-diode barrier for use in conventional fire detection systems for protection within hazardous areas.Each Zone contains two stages of pulse-tested Zener or forward- connected diodes and an infallible terminating resistor. In the event of an electrical fault in the safe area the diodes limit the voltage that can reach the hazardous area and the resistor limits the current. A fuse protects the diodes and the two stages of voltage limitation ensure continued safety if either stage should fail. No active output-current limiting circuits are employed.Model MTL7728 is certified ia for all zones and IIC for all explosive atmospheres.The MTL7700 Series intrinsically safe shunt-diode safety barriers are innovative devices designed to provide exceptionally high packing densities straightforward installation and simplified connection commissioning and maintenance facilities. The MTL7700 Series include secondary replaceable fuses. These are useful where there is the possibility of faults occurring during commissioning which would otherwise blow the barriers internal safety fuses.One secondary replaceable fuse for each barrier channel is provided and is lower in value than the safety related fuse. Fuses are packaged in small mouldings which can be latched in a disconnect position to break the safe and hazardous areas during commissioning maintenance and fault finding thus avoiding the need for additional disconnect terminals.Key FeaturesRemovable colour-coded terminalsBussed power feed to other modulesRelay and solid state switch modulesDual channel variants - 6.3mm per channelProximity detector inputsCompatible terminal numbering and safety descriptionsDimensions 105 x 90 x 12.6mmNumber of Channels 1Supply Voltage 28 V dcSafety Voltage Maximum 26 V dcSafety Current Resistance 300ohmSafety Current Maximum 93mASignal Type AnalogueMinimum Operating Temperature -20CMaximum Operating Temperature 65CHazardous Area Certification ATEXOperating Temperature Range Maximum of 65 C

GBP 77.08
1

FireClass FC410CIM Contact Input Module

Advanced MxPro 5 MXP-536 P-BUS 8 Way Conventional Zone Card

Apollo Intelligent Open Area Red Sounder Sonos - 55000-001APO

Apollo Intelligent Red Open-Area Sounder Beacon - 55000-005APO

Advanced MxPro 5 MXP-536F 8-Way Programmable Zone Monitor Card Fitted

Apollo SA5501-320APO Open-Area VID White Body White Flash

Apollo SA5501-321APO Open-Area VID White Body Red Flash